Volumn , Issue , 2012, Pages 33-36

Smart instruments: Wireless technology invades the operating room

Author keywords

biosensors; computer assisted surgery; in vivo; remote patient monitoring; Smart instruments; smart surgical tools; wireless diagnostics

Indexed keywords

BODY AREA NETWORK; COMPUTER ASSISTED SURGERY; DIAGNOSING CAPABILITY; DIAGNOSTIC MONITORING; HEALTHCARE TECHNOLOGY; IN-VIVO; INDOOR POSITIONING; LOW POWER; MEDICAL INDUSTRIES; MEDICAL INSTRUMENTS; REMOTE LOCATION; RESEARCH TRENDS; SMALL FORM FACTORS; SMART INSTRUMENTS; SURGICAL TOOLS; WIRELESS SENSING; WIRELESS SENSORS NETWORKS; WIRELESS SYSTEMS; WIRELESS TECHNOLOGIES;

EID: 84860572436     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BioWireless.2012.6172743     Document Type: Conference Paper
Times cited : (15)

References (13)
  • 1
    • 0036911363 scopus 로고    scopus 로고
    • Shoe-integrated sensor system for wireless gait analysis and real-time feedback
    • Oct.
    • S. Morris, J. Paradiso, "Shoe-integrated sensor system for wireless gait analysis and real-time feedback," Proc. of the 2nd Joint IEEE EMBS and BMES Conf., Oct. 2002, pp. 2468-2469.
    • (2002) Proc. of the 2nd Joint IEEE EMBS and BMES Conf. , pp. 2468-2469
    • Morris, S.1    Paradiso, J.2
  • 2
    • 73849116738 scopus 로고    scopus 로고
    • Micro-cantilever array pressure measurement system for biomedical instrumentation
    • Feb.
    • W. Qu, S. Islam, M. Mahfouz, G. To, and S. Mofasta, "Micro- cantilever array pressure measurement system for biomedical instrumentation, " IEEE Sensors Journal , vol. 10, no.2, 321-330, Feb. 2010.
    • (2010) IEEE Sensors Journal , vol.10 , Issue.2 , pp. 321-330
    • Qu, W.1    Islam, S.2    Mahfouz, M.3    To, G.4    Mofasta, S.5
  • 3
    • 79953093010 scopus 로고    scopus 로고
    • A multi-tag access scheme for indoor UWB localization systems used in medical environments
    • Phoenix, AZ, Jan.
    • M. Kuhn, M. Mahfouz, J. Turnmire, Y. Wang, and A. Fathy, "A multi-tag access scheme for indoor UWB localization systems used in medical environments," Proc. of IEEE Topical Conf. on BioWireleSS, Phoenix, AZ, Jan. 2011, pp. 75-78.
    • (2011) Proc. of IEEE Topical Conf. on BioWireleSS , pp. 75-78
    • Kuhn, M.1    Mahfouz, M.2    Turnmire, J.3    Wang, Y.4    Fathy, A.5
  • 4
    • 33847316886 scopus 로고    scopus 로고
    • An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column
    • DOI 10.1016/j.medengphy.2006.06.012, PII S1350453306001421
    • A. Rohlmann, U. Gabel , F. Graichen, A. Bender, and G. Bergmann, "An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column," Med. Eng. & Phy., 29 (5), 580-585, Aug. 2006. (Pubitemid 46330872)
    • (2007) Medical Engineering and Physics , vol.29 , Issue.5 , pp. 580-585
    • Rohlmann, A.1    Gabel, U.2    Graichen, F.3    Bender, A.4    Bergmann, G.5
  • 5
    • 79951888717 scopus 로고    scopus 로고
    • A high efficiency inductive power link and backward telemetry for biomedical applications
    • Nov.
    • Q. Ma, M. Haider, and S. Islam, "A high efficiency inductive power link and backward telemetry for biomedical applications," IEEE sensors 2010, pp. 89-93, Nov. 2010.
    • (2010) IEEE Sensors 2010 , pp. 89-93
    • Ma, Q.1    Haider, M.2    Islam, S.3
  • 6
    • 39549107342 scopus 로고    scopus 로고
    • Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission
    • DOI 10.1109/TBCAS.2007.913130
    • U.-M. Jow, and M. Ghovanloo, "Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission," IEEE Trans. Bio. Circuits and Systems, Vol. 1, No. 3, pp. 193-202, Sep. 2007. (Pubitemid 351279738)
    • (2007) IEEE Transactions on Biomedical Circuits and Systems , vol.1 , Issue.3 , pp. 193-202
    • Jow, U.-M.1    Ghovanloo, M.2
  • 7
    • 75049084902 scopus 로고    scopus 로고
    • Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
    • Oct.
    • U.-M. Jow, and M. Ghovanloo, "Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments," IEEE Trans. Bio. Circuits and Systems, Vol. 3, No. 5, pp. 339-347, Oct. 2009.
    • (2009) IEEE Trans. Bio. Circuits and Systems , vol.3 , Issue.5 , pp. 339-347
    • Jow, U.-M.1    Ghovanloo, M.2
  • 9
    • 33846669123 scopus 로고    scopus 로고
    • Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants
    • DOI 10.1109/TBME.2006.886857, 9
    • F. Graichen, R. Arnold, A. Rohlmann, and G. Bergmann, "Implantable 9-channel telemetry system for in-vivo load measurements with orthopedic implants," IEEE Trans Biomed Eng. Vol. 54, No. 2 pp. 253-261, Feb 2007. (Pubitemid 46188168)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.2 , pp. 253-261
    • Graichen, F.1    Arnold, R.2    Rohlmann, A.3    Bergmann, G.4
  • 10
    • 0030043486 scopus 로고    scopus 로고
    • Patient monitoring system for load measurement with spinal fixation devices
    • DOI 10.1016/1350-4533(95)00030-5
    • F. Graichen, G. Bergmann, and A. Rohlmann, "Patient monitoring system for load measurement with spinal fixation devices," Med. Eng & Phy. Vol. 18, no 2 pp. 167-174, Mar. 1996. (Pubitemid 26058389)
    • (1996) Medical Engineering and Physics , vol.18 , Issue.2 , pp. 167-174
    • Graichen, F.1    Bergmann, G.2    Rohlmann, A.3
  • 11
    • 0033213747 scopus 로고    scopus 로고
    • Hip endoprosthesis for in vivo measurement of joint force and temperature
    • DOI 10.1016/S0021-9290(99)00110-4, PII S0021929099001104
    • F. Graichen, G. Bergmann, and A. Rohlmann, "Hip endoprosthesis for in vivo measurement of joint force and temperature," J. Biomech., Vol. 32, no. 10, pp. 1113-1117, Oct. 1999. (Pubitemid 29356051)
    • (1999) Journal of Biomechanics , vol.32 , Issue.10 , pp. 1113-1117
    • Graichen, F.1    Bergmann, G.2    Rohlmann, A.3
  • 12
    • 10444238549 scopus 로고    scopus 로고
    • An implantable telemetry device to measure intra-articular tibial forces
    • DOI 10.1016/j.jbiomech.2004.02.011, PII S0021929004000892
    • D. D'Lima, C. Townsend, S. Arms, B. Morris, and C. Colwell, "An implantable telemetry device to measure intra-articular tibial forces ", J. Biomech., Vol. 38, no. 2, 299-304, Feb. 2005. (Pubitemid 39642951)
    • (2005) Journal of Biomechanics , vol.38 , Issue.2 , pp. 299-304
    • D'Lima, D.D.1    Townsend, C.P.2    Arms, S.W.3    Morris, B.A.4    Colwell Jr., C.W.5
  • 13
    • 33847316886 scopus 로고    scopus 로고
    • An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column
    • DOI 10.1016/j.medengphy.2006.06.012, PII S1350453306001421
    • A. Rohlmann, U. Gabel, F. Graichen, A. Bender, G. Bergmann, "An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column," Med. Eng. & Phy., Vol. 29, no. 5, pp. 580-585, Jun. 2007. (Pubitemid 46330872)
    • (2007) Medical Engineering and Physics , vol.29 , Issue.5 , pp. 580-585
    • Rohlmann, A.1    Gabel, U.2    Graichen, F.3    Bender, A.4    Bergmann, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.