메뉴 건너뛰기




Volumn 12, Issue 6, 2012, Pages 1914-1918

Glass-based continuous-flow PCR chip with a portable control system for DNA amplification

Author keywords

DNA amplification; microelectromechanical systems (MEMS); Ni thermometer; NiCr heater; polymerase chain reaction (PCR) chip; temperature control system

Indexed keywords

AMPLIFICATION FACTORS; CONTINUOUS-FLOW; DNA AMPLIFICATION; DNA SAMPLES; FLOWTHROUGH; INJECTION RATES; MICROFLUIDIC CHANNEL; NICR HEATER; PCR CHIPS; SILICON SUBSTRATES; THREE TEMPERATURE;

EID: 84860511316     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2011.2182047     Document Type: Article
Times cited : (9)

References (14)
  • 1
    • 0034777562 scopus 로고    scopus 로고
    • High-throughput PCR in silicon based microchamber array
    • DOI 10.1016/S0956-5663(01)00248-2, PII S0956566301002482
    • H. Nagai, Y. Murakami, K. Yokoyama, and E. Tamiya, "High-throughput PCR in silicon based microchamber array," Biosensors Bioelectron., vol. 16, nos. 9-12, pp. 1015-1019, Dec. 2001. (Pubitemid 33000229)
    • (2001) Biosensors and Bioelectronics , vol.16 , Issue.9-12 , pp. 1015-1019
    • Nagai, H.1    Murakami, Y.2    Yokoyama, K.3    Tamiya, E.4
  • 2
    • 0025326285 scopus 로고
    • Minimizing the time required for DNA amplification by efficient heat transfer to small samples
    • DOI 10.1016/0003-2697(90)90090-V
    • C. T. Wittwer, G. C. Fillmore, and D. J. Garling, "Minimizing the time required for DNA amplification by efficient heat-transfer to small samples," Anal. Biochem., vol. 186, no. 2, pp. 328-331, May 1990. (Pubitemid 20153515)
    • (1990) Analytical Biochemistry , vol.186 , Issue.2 , pp. 328-331
    • Wittwer, C.T.1    Fillmore, G.C.2    Garling, D.J.3
  • 3
    • 0033743165 scopus 로고    scopus 로고
    • Monolithic integrated microfluidic DNA amplification and capillary electrophoresis analysis system
    • May
    • E. T. Lagally, P. C. Simpson, and R. A. Mathies, "Monolithic integrated microfluidic DNA amplification and capillary electrophoresis analysis system," Sensors Actuat. B, vol. 63, no. 3, pp. 138-146, May 2000.
    • (2000) Sensors Actuat. B , vol.63 , Issue.3 , pp. 138-146
    • Lagally, E.T.1    Simpson, P.C.2    Mathies, R.A.3
  • 5
    • 22544479775 scopus 로고    scopus 로고
    • A novel miniaturized PCR multi-reactor array fabricated using flip-chip bonding techniques
    • DOI 10.1088/0960-1317/15/8/014, PII S0960131705936395
    • Z. Q. Zou, X. Chen, Q. H. Jin, M. S. Yang, and J. L. Zhao, "A novel miniaturized PCR multi-reactor array fabricated using flip-chip bonding techniques," J. Micromech. Microeng., vol. 15, no. 8, pp. 1476-1481, Aug. 2005. (Pubitemid 41009744)
    • (2005) Journal of Micromechanics and Microengineering , vol.15 , Issue.8 , pp. 1476-1481
    • Zou, Z.-Q.1    Chen, X.2    Jin, Q.-H.3    Yang, M.-S.4    Zhao, J.-L.5
  • 6
    • 0037095347 scopus 로고    scopus 로고
    • A heater-integrated transparent microchannel chip for continuous-flow PCR
    • DOI 10.1016/S0925-4005(02)00016-3, PII S0925400502000163
    • K. Sun, A. Yamaguchi, Y. Ishida, S. Matsuo, and H. Misawa, "A heaterintegrated transparent microchannel chip for continuous-flow PCR," Sensors Actuat. B, vol. 84, nos. 2-3, pp. 283-289, May 2002. (Pubitemid 34704180)
    • (2002) Sensors and Actuators, B: Chemical , vol.84 , Issue.2-3 , pp. 283-289
    • Sun, K.1    Yamaguchi, A.2    Ishida, Y.3    Matsuo, S.4    Misawa, H.5
  • 7
    • 2542506166 scopus 로고    scopus 로고
    • Microfabricated flow-through PCR device for underwater microbiological study
    • T. Fukuba, T. Naganuma, and T. Fujii, "Microfabricated flow-through PCR device for underwater microbiological study," in Proc. Int. Symp. Underwater Technol., 2002, pp. 101105.
    • (2002) Proc. Int. Symp. Underwater Technol , pp. 101105
    • Fukuba, T.1    Naganuma, T.2    Fujii, T.3
  • 8
    • 0037439263 scopus 로고    scopus 로고
    • Microfabricated device for DNA and RNA amplification by continuous-flow polymerase chain reaction and reverse transcription-polymerase chain reaction with cycle number selection
    • DOI 10.1021/ac0260239
    • P. J. Obeid, T. K. Christopoulos, H. J. Crabtree, and C. J. Backhouse, "Microfabricated device for DNA and RNA amplification by continuousflow polymerase chain reaction and reverse transcription-polymerase chain reaction with cycle number selection," Anal. Biochem., vol. 75, no. 2, pp. 288-295, Jan. 2003. (Pubitemid 36119775)
    • (2003) Analytical Chemistry , vol.75 , Issue.2 , pp. 288-295
    • Obeid, P.J.1    Christopoulos, T.K.2    Crabtree, H.J.3    Backhouse, C.J.4
  • 9
    • 72849112298 scopus 로고    scopus 로고
    • PCR amplification and genetic analysis in a microwell cell culturing chip
    • Dec
    • S. Lindstrom, M. Hammond, H. Brismar, H. Andersson-Svahn, and A. Ahmadian, "PCR amplification and genetic analysis in a microwell cell culturing chip," Lab Chip, vol. 9, no. 24, pp. 3465-3471, Dec. 2009.
    • (2009) Lab Chip , vol.9 , Issue.24 , pp. 3465-3471
    • Lindstrom, S.1    Hammond, M.2    Brismar, H.3    Andersson-Svahn, H.4    Ahmadian, A.5
  • 10
    • 67349280902 scopus 로고    scopus 로고
    • Multiplex real-time PCR for detection, identification and quantification of 'Candidatus Liberibacter solanacearum' in potato plants with zebra chip
    • Jul
    • W. Li, J. A. Abad, R. D. French-Monar, J. Rascoe, A. Wen, N. C. Gudmestad, G. A. Secor, I.-M. Lee, Y. Duan, and L. Levy, "Multiplex real-time PCR for detection, identification and quantification of 'Candidatus Liberibacter solanacearum' in potato plants with zebra chip," J. Microbiol. Methods, vol. 78, no. 1, pp. 59-65, Jul. 2009.
    • (2009) J. Microbiol. Methods , vol.78 , Issue.1 , pp. 59-65
    • Li, W.1    Abad, J.A.2    French-Monar, R.D.3    Rascoe, J.4    Wen, A.5    Gudmestad, N.C.6    Secor, G.A.7    Lee, I.-M.8    Duan, Y.9    Levy, L.10
  • 11
    • 77950545496 scopus 로고    scopus 로고
    • Microheater based on magnetic nanoparticle embedded PDMS
    • Apr
    • J. A. Kim, S. H. Lee, H. Park, J. H. Kim, and T. H. Park, "Microheater based on magnetic nanoparticle embedded PDMS," Nanotechnology, vol. 21, no. 16, p. 165102, Apr. 2010.
    • (2010) Nanotechnology , vol.21 , Issue.16 , pp. 165102
    • Kim, J.A.1    Lee, S.H.2    Park, H.3    Kim, J.H.4    Park, T.H.5
  • 12
    • 0037400556 scopus 로고    scopus 로고
    • Biocompatibility and biofouling of MEMS drug delivery devices
    • DOI 10.1016/S0142-9612(02)00565-3
    • G. Voskerician, M. S. Shive, R. S. Shawgo, H. von Recum, J. M. Anderson, M. J. Cima, and R. Langer, "Biocompatibility and biofouling of MEMS drug delivery devices," Biomaterials, vol. 24, no. 11, pp. 1959-1967, May 2003. (Pubitemid 36297040)
    • (2003) Biomaterials , vol.24 , Issue.11 , pp. 1959-1967
    • Voskerician, G.1    Shive, M.S.2    Shawgo, R.S.3    Von Recum, H.4    Anderson, J.M.5    Cima, M.J.6    Langer, R.7
  • 13
    • 43949140187 scopus 로고    scopus 로고
    • Study on metal membrane temperature sensor and microheater for PCR chip
    • PII S0218625X08011184
    • W. P. Yan, N. Xue, X. H. Shi, J. S. Liu, and J. H. Guo, "Study on metal membrane temperature sensor and microheater for PCR chip," Surf. Rev. Lett., vol. 15, no. 1, pp. 183-187, Feb. 2008. (Pubitemid 351700667)
    • (2008) Surface Review and Letters , vol.15 , Issue.1-2 , pp. 183-187
    • Yan, W.1    Xue, N.2    Shi, X.3    Liu, J.4    Guo, J.5
  • 14


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.