메뉴 건너뛰기




Volumn 8313, Issue , 2012, Pages

Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain

Author keywords

Channelized Hottelling Observer; correlation between human observer and model observer; Human observer; lesion detection and localization; LROC; model observer; ROC; signal location uncertainty

Indexed keywords

CORRELATION DETECTORS; IMAGE QUALITY; LOCATION; MEDICAL IMAGING;

EID: 84860380348     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.912126     Document Type: Conference Paper
Times cited : (7)

References (30)
  • 1
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • Brenner, D.J. and E.J. Hall, "Computed tomography - an increasing source of radiation exposure," N Engl J Med, 357(22), 2277-84, (2007)
    • (2007) N Engl J Med , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 2
    • 84860376934 scopus 로고    scopus 로고
    • Scan Parameter Optimization
    • Date Accessed: 1/10/2011
    • AAPM CT Summit, "Scan Parameter Optimization. http://www.aapm.org/ meetings/2010CTS/default.asp. Date Accessed: 1/10/2011.
    • AAPM CT Summit
  • 3
    • 77957344632 scopus 로고    scopus 로고
    • Addressing overutilization in medical imaging
    • Hendee, W.R., et al., "Addressing overutilization in medical imaging," Radiology, 257(1), 240-5, (2010)
    • (2010) Radiology , vol.257 , Issue.1 , pp. 240-245
    • Hendee, W.R.1
  • 4
  • 5
    • 73649113284 scopus 로고    scopus 로고
    • Radiation dose reduction in computed tomography: Techniques and future perspective
    • Yu, L., et al., "Radiation dose reduction in computed tomography: techniques and future perspective," Imaging Med., (1) 65-84, (2009)
    • (2009) Imaging Med , Issue.1 , pp. 65-84
    • Yu, L.1
  • 6
    • 0003908115 scopus 로고
    • Medical Imaging - The Assessment of Image Quality
    • International Commission on Radiation Units and Measurements ICRU
    • ICRU Report 54, "Medical Imaging - The Assessment of Image Quality," International Commission on Radiation Units and Measurements (ICRU), (1995)
    • (1995) ICRU Report 54
  • 7
    • 0027425561 scopus 로고
    • Model observers for assessment of image quality
    • Barrett, H.H., et al., "Model observers for assessment of image quality," Proc Natl Acad Sci U S A, 90(21), 9758-65, (1993)
    • (1993) Proc Natl Acad Sci U S A , vol.90 , Issue.21 , pp. 9758-9765
    • Barrett, H.H.1
  • 9
    • 0023502720 scopus 로고
    • Addition of a channel mechanism to the ideal-observer model
    • Myers, K.J. and H.H. Barrett, "Addition of a channel mechanism to the ideal-observer model," J Opt Soc Am A, 4(12), 2447-57, (1987)
    • (1987) J Opt Soc Am A , vol.4 , Issue.12 , pp. 2447-2457
    • Myers, K.J.1    Barrett, H.H.2
  • 12
    • 0034049161 scopus 로고    scopus 로고
    • Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging
    • Gifford, H.C., et al., "Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging," Journal of Nuclear Medicine, 41(3), 514-21, (2000)
    • (2000) Journal of Nuclear Medicine , vol.41 , Issue.3 , pp. 514-521
    • Gifford, H.C.1
  • 13
    • 0037228436 scopus 로고    scopus 로고
    • Performance evaluation of a modular gamma camera using a detectability index
    • Sain, J.D. and H.H. Barrett, "Performance evaluation of a modular gamma camera using a detectability index,"Journal of Nuclear Medicine, 44(1), 58-66, (2003)
    • (2003) Journal of Nuclear Medicine , vol.44 , Issue.1 , pp. 58-66
    • Sain, J.D.1    Barrett, H.H.2
  • 15
    • 0035049369 scopus 로고    scopus 로고
    • Human observer detection experiments with mammograms and power-law noise
    • Burgess, A.E., F.L. Jacobson, and P.F. Judy, "Human observer detection experiments with mammograms and power-law noise," Medical Physics, 28(4), 419-437, (2001)
    • (2001) Medical Physics , vol.28 , Issue.4 , pp. 419-437
    • Burgess, A.E.1    Jacobson, F.L.2    Judy, P.F.3
  • 16
    • 34547403809 scopus 로고    scopus 로고
    • Effect of dose reduction on the detection of mammographic lesions: A mathematical observer model analysis
    • Chawla, A.S., et al., "Effect of dose reduction on the detection of mammographic lesions: A mathematical observer model analysis," Medical Physics, 34(8), 3385-3398, (2007)
    • (2007) Medical Physics , vol.34 , Issue.8 , pp. 3385-3398
    • Chawla, A.S.1
  • 17
    • 77954630021 scopus 로고    scopus 로고
    • An Observer Model for Lesion Detectability in Contrast-Enhanced Digital Mammography
    • Hill, M.L., J.G. Mainprize, and M.J. Yaffe, "An Observer Model for Lesion Detectability in Contrast-Enhanced Digital Mammography " Digital Mammography, 6136(720-727, (2010)
    • (2010) Digital Mammography , vol.6136 , pp. 720-727
    • Hill, M.L.1    Mainprize, J.G.2    Yaffe, M.J.3
  • 18
    • 54949086053 scopus 로고    scopus 로고
    • Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images
    • Richard, S. and J.H. Siewerdsen, "Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images," Med Phys, 35(11), 5043-53, (2008)
    • (2008) Med Phys , vol.35 , Issue.11 , pp. 5043-5053
    • Richard, S.1    Siewerdsen, J.H.2
  • 19
    • 77952363141 scopus 로고    scopus 로고
    • Anatomical background and generalized detectability in tomosynthesis and cone-beam CT
    • Gang, G.J., et al., "Anatomical background and generalized detectability in tomosynthesis and cone-beam CT,"Medical Physics, 37(5), 1948-1965, (2010)
    • (2010) Medical Physics , vol.37 , Issue.5 , pp. 1948-1965
    • Gang, G.J.1
  • 20
    • 77950553921 scopus 로고    scopus 로고
    • Task-based assessment of breast tomosynthesis: Effect of acquisition parameters and quantum noise
    • Reiser, I. and R.M. Nishikawa, "Task-based assessment of breast tomosynthesis: Effect of acquisition parameters and quantum noise," Medical Physics, 37(4), 1591-1600, (2010)
    • (2010) Medical Physics , vol.37 , Issue.4 , pp. 1591-1600
    • Reiser, I.1    Nishikawa, R.M.2
  • 21
    • 77953523692 scopus 로고    scopus 로고
    • Quantitative imaging in breast tomosynthesis and CT: Comparison of detection and estimation task performance
    • Richard, S. and E. Samei, "Quantitative imaging in breast tomosynthesis and CT: Comparison of detection and estimation task performance," Medical Physics, 37(6), 2627-2637, (2010)
    • (2010) Medical Physics , vol.37 , Issue.6 , pp. 2627-2637
    • Richard, S.1    Samei, E.2
  • 22
    • 33750802387 scopus 로고    scopus 로고
    • Using human and model performance to compare MRI reconstructions
    • Tisdall, M.D. and M.S. Atkins, "Using human and model performance to compare MRI reconstructions," Ieee Transactions on Medical Imaging, 25(11), 1510-1517, (2006)
    • (2006) Ieee Transactions on Medical Imaging , vol.25 , Issue.11 , pp. 1510-1517
    • Tisdall, M.D.1    Atkins, M.S.2
  • 23
    • 0019405245 scopus 로고
    • Lesion detection and signal-to-noise ratio in CT images
    • Judy, P.F., R.G. Swensson, and M. Szulc, "Lesion detection and signal-to-noise ratio in CT images," Med Phys, 8(1), 13-23, (1981)
    • (1981) Med Phys , vol.8 , Issue.1 , pp. 13-23
    • Judy, P.F.1    Swensson, R.G.2    Szulc, M.3
  • 24
    • 34547254544 scopus 로고    scopus 로고
    • Application of the noise power spectrum in modern diagnostic MDCT: Part II. Noise power spectra and signal to noise
    • Boedeker, K.L. and M.F. McNitt-Gray, "Application of the noise power spectrum in modern diagnostic MDCT: part II. Noise power spectra and signal to noise," Phys Med Biol, 52(14), 4047-61, (2007)
    • (2007) Phys Med Biol , vol.52 , Issue.14 , pp. 4047-4061
    • Boedeker, K.L.1    McNitt-Gray, M.F.2
  • 25
    • 42649084336 scopus 로고    scopus 로고
    • Image covariance and lesion detectability in direct fan-beam x-ray computed tomography
    • Wunderlich, A. and F. Noo, "Image covariance and lesion detectability in direct fan-beam x-ray computed tomography," Phys Med Biol, 53(10), 2471-93, (2008)
    • (2008) Phys Med Biol , vol.53 , Issue.10 , pp. 2471-2493
    • Wunderlich, A.1    Noo, F.2
  • 26
    • 0002822137 scopus 로고    scopus 로고
    • "Proper" Binormal ROC Curves: Theory and Maximum-Likelihood Estimation
    • Metz, C.E. and X. Pan, ""Proper" Binormal ROC Curves: Theory and Maximum-Likelihood Estimation,"Journal of mathematical psychology, 43(1), 1-33, (1999)
    • (1999) Journal of Mathematical Psychology , vol.43 , Issue.1 , pp. 1-33
    • Metz, C.E.1    Pan, X.2
  • 27
    • 0029822853 scopus 로고    scopus 로고
    • Unified measurement of observer performance in detecting and localizing target objects on images
    • Swensson, R.G., "Unified measurement of observer performance in detecting and localizing target objects on images," Med Phys, 23(10), 1709-25, (1996)
    • (1996) Med Phys , vol.23 , Issue.10 , pp. 1709-1725
    • Swensson, R.G.1
  • 28
    • 0041844093 scopus 로고    scopus 로고
    • Automated computer evaluation and optimization of image compression of x-ray coronary angiograms for signal known exactly detection tasks
    • Eckstein, M., et al., "Automated computer evaluation and optimization of image compression of x-ray coronary angiograms for signal known exactly detection tasks," Optics Express, 11(5), 460-475, (2003)
    • (2003) Optics Express , vol.11 , Issue.5 , pp. 460-475
    • Eckstein, M.1
  • 29
    • 33749640330 scopus 로고    scopus 로고
    • Adaptive detection mechanisms in globally statistically nonstationary-oriented noise
    • Zhang, Y., C.K. Abbey, and M.P. Eckstein, "Adaptive detection mechanisms in globally statistically nonstationary-oriented noise," J Opt Soc Am A Opt Image Sci Vis, 23(7), 1549-58, (2006)
    • (2006) J Opt Soc Am A Opt Image Sci Vis , vol.23 , Issue.7 , pp. 1549-1558
    • Zhang, Y.1    Abbey, C.K.2    Eckstein, M.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.