-
1
-
-
0002365202
-
Adaptive optics for astronomy: Principles, performance, and applications
-
J. M. Beckers, "Adaptive optics for astronomy: Principles, performance, and applications," Annu. Rev. Astrom. Astrophys., vol. 31, pp. 13-62, 1993.
-
(1993)
Annu. Rev. Astrom. Astrophys
, vol.31
, pp. 13-62
-
-
Beckers, J.M.1
-
2
-
-
2742515924
-
Progress in ground-based optical telescopes
-
D. Enard, A. Marechal, and J. Espiard, "Progress in ground-based optical telescopes," Rep. Prog. Pkys., vol. 59, pp. 601-656, 1996.
-
(1996)
Rep. Prog. Pkys
, vol.59
, pp. 601-656
-
-
Enard, D.1
Marechal, A.2
Espiard, J.3
-
4
-
-
0004187494
-
-
F. Roddier, Ed, Cambridge, U.K, Cambridge Univ. Press
-
F. Roddier, Ed., Adaptive Optics in Astronomy. Cambridge, U.K.: Cambridge Univ. Press, 1999.
-
(1999)
Adaptive Optics in Astronomy
-
-
-
5
-
-
28144438243
-
Limits of adaptive optics for high-contrast imaging
-
O. Guyon, "Limits of adaptive optics for high-contrast imaging," Astrophys. J., vol. 629, pp. 592-614, 2005.
-
(2005)
Astrophys. J
, vol.629
, pp. 592-614
-
-
Guyon, O.1
-
6
-
-
0005284268
-
Wavefront sensing
-
F. Roddier, Ed. Cambridge, U.K, Cambridge Univ. Press
-
G. Rousset, "Wavefront sensing," in Adaptive Optics in Astronomy, F. Roddier, Ed. Cambridge, U.K.: Cambridge Univ. Press, 1999.
-
(1999)
Adaptive Optics in Astronomy
-
-
Rousset, G.1
-
7
-
-
0020180312
-
Phase retrieval and diversity in adaptive optics
-
R. A. Gonsalves, "Phase retrieval and diversity in adaptive optics," Opt. Eng., vol. 21, no. 5, pp. 829-832, 1982.
-
(1982)
Opt. Eng
, vol.21
, Issue.5
, pp. 829-832
-
-
Gonsalves, R.A.1
-
8
-
-
84891208678
-
Joint estimation of object and aberrations using phase diversity
-
R. G. Paxman, T. J. Schulz, and J. R. Fienup, "Joint estimation of object and aberrations using phase diversity," J. Opt. Soc. Amer., vol. 7, pp. 1072-1085, 1992.
-
(1992)
J. Opt. Soc. Amer
, vol.7
, pp. 1072-1085
-
-
Paxman, R.G.1
Schulz, T.J.2
Fienup, J.R.3
-
9
-
-
0016104060
-
Real-time correction of atmospherically degraded telescope images through image sharpening
-
R. A. Muller and A. Buffington, "Real-time correction of atmospherically degraded telescope images through image sharpening," J. Opt. Soc. Amer., vol. 64, no. 9, pp. 1200-1210, 1974.
-
(1974)
J. Opt. Soc. Amer
, vol.64
, Issue.9
, pp. 1200-1210
-
-
Muller, R.A.1
Buffington, A.2
-
10
-
-
0033700254
-
Adaptive imaging system using image quality metric based on statistical analysis of speckle fields
-
D. P. Casasent and A. G. Tescher, Eds, Jul
-
D. H. Kim, K. Kolesnikov, A. A. Kostrzewski, G. D. Savant, A. A. Vasiliev, and M. A. Vorontsov, "Adaptive imaging system using image quality metric based on statistical analysis of speckle fields," in Proc. SPIE, D. P. Casasent and A. G. Tescher, Eds., Jul. 2000, vol. 4044, pp. 177-186.
-
(2000)
Proc. SPIE
, vol.4044
, pp. 177-186
-
-
Kim, D.H.1
Kolesnikov, K.2
Kostrzewski, A.A.3
Savant, G.D.4
Vasiliev, A.A.5
Vorontsov, M.A.6
-
11
-
-
0030781870
-
A speckle target adaptive imaging technique in the presence of distributed aberrations
-
Jan
-
G. C. Ng, P. D. Freiburger, W. F. Walker, and G. E. Trahey, "A speckle target adaptive imaging technique in the presence of distributed aberrations," IEEE Trans. Ultrason Ferroelect. Freq. Control, vol. 44, no. 1, pp. 140-151, Jan. 1997.
-
(1997)
IEEE Trans. Ultrason Ferroelect. Freq. Control
, vol.44
, Issue.1
, pp. 140-151
-
-
Ng, G.C.1
Freiburger, P.D.2
Walker, W.F.3
Trahey, G.E.4
-
12
-
-
0033295357
-
Adaptive imaging in the breast
-
Caesars Tahoe, NV
-
R. C. Gauss, G. E. Trahey, and M. S. Soo, "Adaptive imaging in the breast," in Proc. Int. Symp. IEEE Ultrason. Symp., Caesars Tahoe, NV, 1999, pp. 1563-1569.
-
(1999)
Proc. Int. Symp. IEEE Ultrason. Symp
, pp. 1563-1569
-
-
Gauss, R.C.1
Trahey, G.E.2
Soo, M.S.3
-
13
-
-
21644466462
-
High resolution ultrasound beamforming using synthetic and adaptive imaging techniques
-
Washington, DC
-
A. T. Fernandez, J. J. Dahl, K. Gammelmark, D. M. Dumont, and G. E. Trahey, "High resolution ultrasound beamforming using synthetic and adaptive imaging techniques," in 2002 IEEE Int. Symp. Biomed Imag., Washington, DC, 2002, pp. 433-436.
-
(2002)
2002 IEEE Int. Symp. Biomed Imag
, pp. 433-436
-
-
Fernandez, A.T.1
Dahl, J.J.2
Gammelmark, K.3
Dumont, D.M.4
Trahey, G.E.5
-
14
-
-
0037289710
-
Adaptive imaging using the generalized coherence factor
-
Feb
-
P. C. Li and M. L. Li, "Adaptive imaging using the generalized coherence factor," IEEE Trans. Ultrason. Ferroelect. Freq. Control, vol. 50, no. 2, pp. 128-141, Feb. 2003.
-
(2003)
IEEE Trans. Ultrason. Ferroelect. Freq. Control
, vol.50
, Issue.2
, pp. 128-141
-
-
Li, P.C.1
Li, M.L.2
-
15
-
-
2342530481
-
Computed tomography sound velocity reconstruction using incomplete data
-
Mar
-
S. W. Huang and P. C. Li, "Computed tomography sound velocity reconstruction using incomplete data," IEEE Trans. Ultrason. Ferroelect. Freq. Contol, vol. 51, no. 3, pp. 329-342, Mar. 2004.
-
(2004)
IEEE Trans. Ultrason. Ferroelect. Freq. Contol
, vol.51
, Issue.3
, pp. 329-342
-
-
Huang, S.W.1
Li, P.C.2
-
16
-
-
0036356801
-
Advances in ultrasound
-
M. Claudon, F. Tranquart, D. H. Evans, F. Lefèvre, and J. M. Correas, "Advances in ultrasound," Eur. Radiol., vol. 12, pp. 7-18, 2002.
-
(2002)
Eur. Radiol
, vol.12
, pp. 7-18
-
-
Claudon, M.1
Tranquart, F.2
Evans, D.H.3
Lefèvre, F.4
Correas, J.M.5
-
17
-
-
26044476154
-
Adaptive imaging using an optimal receive aperture size
-
Apr
-
M. L. Li, S. W. Huang, K. Ustiner, and P. C. Li, "Adaptive imaging using an optimal receive aperture size," Ultrason. Imag., vol. 27, no. 2, pp. 111-127, Apr. 2005.
-
(2005)
Ultrason. Imag
, vol.27
, Issue.2
, pp. 111-127
-
-
Li, M.L.1
Huang, S.W.2
Ustiner, K.3
Li, P.C.4
-
18
-
-
84941604620
-
Feature-guided acquisition and reconstruction of MR images
-
Proceedings of the International Conference on Information Processing in Medical Imaging, H. H. Barrett and A. F. Gmitro, Eds. New York: Springer, Springer
-
Y. Cao and D. N. Levin, "Feature-guided acquisition and reconstruction of MR images," in Proceedings of the International Conference on Information Processing in Medical Imaging, H. H. Barrett and A. F. Gmitro, Eds. New York: Springer, 1993, vol. 687, Lecture Notes in Computer Science, pp. 278-292, Springer.
-
(1993)
Lecture Notes in Computer Science
, vol.687
, pp. 278-292
-
-
Cao, Y.1
Levin, D.N.2
-
19
-
-
0027992115
-
Dynamically adaptive MRI with encoding by singular value decomposition
-
G. P. Zientara, L. P. Panych, and F. A. Jolesz, "Dynamically adaptive MRI with encoding by singular value decomposition," Magn. Reson. Med., vol. 32, no. 2, pp. 268-274, 1994.
-
(1994)
Magn. Reson. Med
, vol.32
, Issue.2
, pp. 268-274
-
-
Zientara, G.P.1
Panych, L.P.2
Jolesz, F.A.3
-
20
-
-
19544375877
-
Fast Imaging Techniques for Interventional MRI
-
I. Young and F. A. Jolesz, Eds. London, U.K, Martin Dunitz, ch. 2, pp
-
G. P. Zientara, "Fast Imaging Techniques for Interventional MRI," in Interventional MR, I. Young and F. A. Jolesz, Eds. London, U.K.: Martin Dunitz, 1995, ch. 2, pp. 25-52.
-
(1995)
Interventional MR
, pp. 25-52
-
-
Zientara, G.P.1
-
21
-
-
0030765539
-
Using prior knowledge of human anatomy to constrain MR image acquisition and reconstruction: Half k-space and full k-space techniques
-
Y. Cao and D. N. Levin, "Using prior knowledge of human anatomy to constrain MR image acquisition and reconstruction: Half k-space and full k-space techniques," Magn. Reson. Imag., vol. 15, no. 6, pp. 669-677, 1997.
-
(1997)
Magn. Reson. Imag
, vol.15
, Issue.6
, pp. 669-677
-
-
Cao, Y.1
Levin, D.N.2
-
22
-
-
0031951296
-
Applicability and efficiency of near-optimal spatial encoding for dynamically adaptive MRI
-
Feb
-
G. P. Zientara, L. P. Panych, and F. A. Jolesz, "Applicability and efficiency of near-optimal spatial encoding for dynamically adaptive MRI," Magn. Reson. Med., vol. 39, no. 2, pp. 204-213, Feb. 1998.
-
(1998)
Magn. Reson. Med
, vol.39
, Issue.2
, pp. 204-213
-
-
Zientara, G.P.1
Panych, L.P.2
Jolesz, F.A.3
-
23
-
-
0032173363
-
Dynamic tracking in interventional MRI using wavelet-encoded gradient-echo sequences
-
Oct
-
M. Wendt, "Dynamic tracking in interventional MRI using wavelet-encoded gradient-echo sequences," IEEE Trans. Med. Imag., vol. 17, no. 10, pp. 803-809, Oct. 1998.
-
(1998)
IEEE Trans. Med. Imag
, vol.17
, Issue.10
, pp. 803-809
-
-
Wendt, M.1
-
24
-
-
0032753179
-
Real-time adaptive functional MRI
-
S. Yoo, C. R. G. Guttmann, L. Zhao, and L. P. Panych, "Real-time adaptive functional MRI," Neurolmage, vol. 10, pp. 596-606, 1999.
-
(1999)
Neurolmage
, vol.10
, pp. 596-606
-
-
Yoo, S.1
Guttmann, C.R.G.2
Zhao, L.3
Panych, L.P.4
-
25
-
-
44449178584
-
Predictive motion modelling for adaptive imaging
-
N. A. Ablitt, J. X. Gao, J. Keegan, D. N. Firmin, L. Stegger, and G. Z. Yang, "Predictive motion modelling for adaptive imaging," Proc. Int. Soc. Mag. Reson. Med., vol. 11, p. 1570, 2003.
-
(2003)
Proc. Int. Soc. Mag. Reson. Med
, vol.11
, pp. 1570
-
-
Ablitt, N.A.1
Gao, J.X.2
Keegan, J.3
Firmin, D.N.4
Stegger, L.5
Yang, G.Z.6
-
26
-
-
38649128494
-
-
J. A. Griffiths, M. G. Metaxas, G. J. Royle, C. Venanzi, C. Esbrand, P. F. van der Stelt, H. Verheij, G. Li, R. Turchetta, A. Fant, P. Gasiorek, S. Theodoridis, H. Georgiou, D. Cavouras, G. Hall, M. Noy, J. Jones, J. Leaver, D. Machin, S. Greenwood, M. Khaleeq, H. Schulerud, J. Ostby, F. Triantis, A. Asimidis, D. Bolanakis, N. Manthos, R. Longo, A. Bergamaschi, and R. D. Speller, A multi-element detector system for intelligent imaging: I-ImaS, in Conf. Rec. IEEE Med. Imag. Conf., Nov. 2006, pp. 2554-2558.
-
J. A. Griffiths, M. G. Metaxas, G. J. Royle, C. Venanzi, C. Esbrand, P. F. van der Stelt, H. Verheij, G. Li, R. Turchetta, A. Fant, P. Gasiorek, S. Theodoridis, H. Georgiou, D. Cavouras, G. Hall, M. Noy, J. Jones, J. Leaver, D. Machin, S. Greenwood, M. Khaleeq, H. Schulerud, J. Ostby, F. Triantis, A. Asimidis, D. Bolanakis, N. Manthos, R. Longo, A. Bergamaschi, and R. D. Speller, "A multi-element detector system for intelligent imaging: I-ImaS," in Conf. Rec. IEEE Med. Imag. Conf., Nov. 2006, pp. 2554-2558.
-
-
-
-
27
-
-
33847642263
-
I-IMAS: A 1.5D sensor for high-resolution scanning
-
A. Fant, P. Gasiorek, R. Turchetta, B. Avset, A. Bergamaschi, D. Cavouras, I. Evangelou, M. J. French, A. Galbiati, H. Georgiou, G. Hall, G. Iles, J. Jones, R. Longo, N. Manthos, M. G. Metaxas, M. Noy, J. M. Ostby, F. Psomadellis, G. J. Royle, H. Schulerud, R. D. Speller, P. F. van der Stelt, S. Theodoridis, F. Triantis, and C. Venanzi, "I-IMAS: A 1.5D sensor for high-resolution scanning," Nucl. Instrvm. Meth. Res., vol. 1573, pp. 27-29, 2007.
-
(2007)
Nucl. Instrvm. Meth. Res
, vol.1573
, pp. 27-29
-
-
Fant, A.1
Gasiorek, P.2
Turchetta, R.3
Avset, B.4
Bergamaschi, A.5
Cavouras, D.6
Evangelou, I.7
French, M.J.8
Galbiati, A.9
Georgiou, H.10
Hall, G.11
Iles, G.12
Jones, J.13
Longo, R.14
Manthos, N.15
Metaxas, M.G.16
Noy, M.17
Ostby, J.M.18
Psomadellis, F.19
Royle, G.J.20
Schulerud, H.21
Speller, R.D.22
van der Stelt, P.F.23
Theodoridis, S.24
Triantis, F.25
Venanzi, C.26
more..
-
28
-
-
44449137773
-
Design of an adaptive SPECT imager
-
presented at the, Orlando, FL, Mar
-
M. Freed, M. A. Kupinski, L. R. Furenlid, and H. H. Barrett, "Design of an adaptive SPECT imager," presented at the Acad. Molecular Imag. Annu. Conf., Orlando, FL, Mar. 2006.
-
(2006)
Acad. Molecular Imag. Annu. Conf
-
-
Freed, M.1
Kupinski, M.A.2
Furenlid, L.R.3
Barrett, H.H.4
-
29
-
-
34347402333
-
A prototype instrument for adaptive SPECT imaging
-
M. Freed, M. A. Kupinski, L. R. Furenlid, M. K. Whitaker, and H. H. Barrett, "A prototype instrument for adaptive SPECT imaging," Proc. SPIE, vol. 6510, pp. 6510-6530, 2007.
-
(2007)
Proc. SPIE
, vol.6510
, pp. 6510-6530
-
-
Freed, M.1
Kupinski, M.A.2
Furenlid, L.R.3
Whitaker, M.K.4
Barrett, H.H.5
-
30
-
-
42949165863
-
A prototype instrument for single-pinhole small-animal adaptive SPECT imaging
-
M. Freed, M. A. Kupinski, L. R. Furenlid, D. W. Wilson, and H. H. Barrett, "A prototype instrument for single-pinhole small-animal adaptive SPECT imaging," Med. Phys., vol. 35, no. 5, pp. 1912-1925, 2008.
-
(2008)
Med. Phys
, vol.35
, Issue.5
, pp. 1912-1925
-
-
Freed, M.1
Kupinski, M.A.2
Furenlid, L.R.3
Wilson, D.W.4
Barrett, H.H.5
-
31
-
-
0025455491
-
Objective assessment of image quality: Effects of quantum noise and object variability
-
Jul
-
H. H. Barrett, "Objective assessment of image quality: Effects of quantum noise and object variability," J. Opt. Soc. Amer., vol. 7, no. 7, pp. 1266-1278, Jul. 1990.
-
(1990)
J. Opt. Soc. Amer
, vol.7
, Issue.7
, pp. 1266-1278
-
-
Barrett, H.H.1
-
33
-
-
33847681330
-
The multi-module, multi-resolution system - a novel small-animal SPECTsystem
-
J. Y. Hesterman, M. A. Kupinski, L. R. Furenlid, D. W. Wilson, and H. H. Barrett, "The multi-module, multi-resolution system - a novel small-animal SPECTsystem,"Med Phys., vol. 34, pp. 983-987, 2007.
-
(2007)
Med Phys
, vol.34
, pp. 983-987
-
-
Hesterman, J.Y.1
Kupinski, M.A.2
Furenlid, L.R.3
Wilson, D.W.4
Barrett, H.H.5
-
34
-
-
34347387105
-
Hardware assessment using the multi-module, multi-resolution system (M3R). A signal-detection study
-
J. Y. Hesterman, M. A. Kupinski, E. Clarkson, and H. H. Barrett, "Hardware assessment using the multi-module, multi-resolution system (M3R). A signal-detection study," Med. Phys., vol. 34, no. 7, pp. 3034-3044, 2007.
-
(2007)
Med. Phys
, vol.34
, Issue.7
, pp. 3034-3044
-
-
Hesterman, J.Y.1
Kupinski, M.A.2
Clarkson, E.3
Barrett, H.H.4
-
35
-
-
44449159141
-
The multimodule multiresolution SPECT system: A tool for variable-pinhole small-animal imaging,
-
Ph.D. dissertation, Univ. Arizona, Tucson
-
J. Hesterman, "The multimodule multiresolution SPECT system: A tool for variable-pinhole small-animal imaging," Ph.D. dissertation, Univ. Arizona, Tucson, 2007.
-
(2007)
-
-
Hesterman, J.1
-
36
-
-
33845873916
-
Objective assessment of image quality. IV. Application to adaptive optics
-
H. H. Barrett, K. J. Myers, N. Devaney, and C. Dainty, "Objective assessment of image quality. IV. Application to adaptive optics," J. Opt. Soc. Amer., vol. 23, pp. 3080-3105, 2006.
-
(2006)
J. Opt. Soc. Amer
, vol.23
, pp. 3080-3105
-
-
Barrett, H.H.1
Myers, K.J.2
Devaney, N.3
Dainty, C.4
-
37
-
-
27644531019
-
Small animal SPECT and its place in the matrix of molecular imaging technologies
-
S. R. Meikle, P. Kench, M. Kassiou, and R. B. Banati, "Small animal SPECT and its place in the matrix of molecular imaging technologies," Phys. Med. Biol., vol. 50, pp. R45-R61, 2005.
-
(2005)
Phys. Med. Biol
, vol.50
-
-
Meikle, S.R.1
Kench, P.2
Kassiou, M.3
Banati, R.B.4
-
38
-
-
33847656328
-
-
M. A. Kupinski and H. H. Barrett, Eds, New York: Springer
-
M. A. Kupinski and H. H. Barrett, Eds., Small-Animal SPECT Imaging. New York: Springer, 2005.
-
(2005)
Small-Animal SPECT Imaging
-
-
-
39
-
-
0038382217
-
High-resolution. SPECT using multipinhole collimation
-
Jun
-
N. Schramm, G. Ebel, U. Engeland, T. Schurrat, M. Behe, and T. Behr, "High-resolution. SPECT using multipinhole collimation," IEEE Trans. Nucl. Sci., vol. 50, no. 3, pp. 315-320, Jun. 2003.
-
(2003)
IEEE Trans. Nucl. Sci
, vol.50
, Issue.3
, pp. 315-320
-
-
Schramm, N.1
Ebel, G.2
Engeland, U.3
Schurrat, T.4
Behe, M.5
Behr, T.6
-
40
-
-
23844518743
-
U-SPECT-I: A novel system for submillimeter-resolution. tomography with radiolabeled molecules in mice
-
F. J. Beekman, F. van der Have, B. Vastenhouw, A. J. A. van der Linden, P. P. van Rijk, J. P. H. Burbach, and M. P. Smidt, "U-SPECT-I: A novel system for submillimeter-resolution. tomography with radiolabeled molecules in mice," J. Nucl. Med., vol. 46, pp. 1194-1200, 2005.
-
(2005)
J. Nucl. Med
, vol.46
, pp. 1194-1200
-
-
Beekman, F.J.1
van der Have, F.2
Vastenhouw, B.3
van der Linden, A.J.A.4
van Rijk, P.P.5
Burbach, J.P.H.6
Smidt, M.P.7
-
41
-
-
33646448140
-
A multipinhole small animal SPECT system with submillimeter spatial resolution
-
T. Funk, P. Depres, W. C. Barber, K. S. Shah, and B. H. Hasegawa, "A multipinhole small animal SPECT system with submillimeter spatial resolution," Med. Phys., vol. 33, no. 5, pp. 1259-1268, 2006.
-
(2006)
Med. Phys
, vol.33
, Issue.5
, pp. 1259-1268
-
-
Funk, T.1
Depres, P.2
Barber, W.C.3
Shah, K.S.4
Hasegawa, B.H.5
-
42
-
-
23844538758
-
Performance of a triple-detector, multiple-pinhole SPECT system with iodine and indium isotopes
-
Rome, Italy
-
R. Zimmerman, S. Moore, and A. Mahmood, "Performance of a triple-detector, multiple-pinhole SPECT system with iodine and indium isotopes," in IEEE Nucl. Sci. Symp. Conf. Rec. 2004 IEEE, Rome, Italy, 2004, vol. 4, pp. 2427-2429.
-
(2004)
IEEE Nucl. Sci. Symp. Conf. Rec. 2004 IEEE
, vol.4
, pp. 2427-2429
-
-
Zimmerman, R.1
Moore, S.2
Mahmood, A.3
-
43
-
-
31844444997
-
SemiSPECT: A small-animal SPECT imager based on eight CZT detector array
-
Feb
-
H. Kim, L. R. Furenlid, M. J. Crawford, D. W. Wilson, H. B. Barber, T. E. Peterson, W. C. J. Hunter, Z. Liu, J. M. Woolfenden, and H. H. Barrett, "SemiSPECT: A small-animal SPECT imager based on eight CZT detector array," Med. Phys., vol. 33, pp. 465-474, Feb. 2006.
-
(2006)
Med. Phys
, vol.33
, pp. 465-474
-
-
Kim, H.1
Furenlid, L.R.2
Crawford, M.J.3
Wilson, D.W.4
Barber, H.B.5
Peterson, T.E.6
Hunter, W.C.J.7
Liu, Z.8
Woolfenden, J.M.9
Barrett, H.H.10
-
44
-
-
3342967054
-
FastSPECT II: A second-generation high-resolution dynamic SPECT imager
-
Jun
-
L. R. Furenlid, D. W. Wilson, C. Yi-chun, K. Hyunki, P. J. Pietraski, M. J. Crawford, and H. H. Barrett, "FastSPECT II: A second-generation high-resolution dynamic SPECT imager," IEEE Trans. Nucl. Sci., vol. 51, no. 3, pp. 631-635, Jun. 2004.
-
(2004)
IEEE Trans. Nucl. Sci
, vol.51
, Issue.3
, pp. 631-635
-
-
Furenlid, L.R.1
Wilson, D.W.2
Yi-chun, C.3
Hyunki, K.4
Pietraski, P.J.5
Crawford, M.J.6
Barrett, H.H.7
-
45
-
-
35148870145
-
System calibration and image reconstruction for a new small-animal SPECT system,
-
Ph.D. dissertation, Univ. Arizona, Tucson
-
Y. Chen, "System calibration and image reconstruction for a new small-animal SPECT system," Ph.D. dissertation, Univ. Arizona, Tucson, 2006.
-
(2006)
-
-
Chen, Y.1
-
46
-
-
0000764161
-
Hotelling trace criterion as a figure of merit for the optimization of imaging systems
-
W. E. Smith and H. H. Barrett, "Hotelling trace criterion as a figure of merit for the optimization of imaging systems," J. Opt. Soc. Amer., vol. 3, pp. 717-725, 1986.
-
(1986)
J. Opt. Soc. Amer
, vol.3
, pp. 717-725
-
-
Smith, W.E.1
Barrett, H.H.2
-
47
-
-
0023335011
-
Hotelling trace criterion and its correlation with human-observer performance
-
R.D. Fiete, H.H. Barrett, W.E. Smith, and K.J. Myers, "Hotelling trace criterion and its correlation with human-observer performance," J. Opt. Soc. Amer., vol. 4, pp. 945-953, 1987.
-
(1987)
J. Opt. Soc. Amer
, vol.4
, pp. 945-953
-
-
Fiete, R.D.1
Barrett, H.H.2
Smith, W.E.3
Myers, K.J.4
-
48
-
-
0001038967
-
The generalization of student's ratio
-
H. Hotelling, "The generalization of student's ratio," Ann. Math. Stat., vol. 2, pp. 360-378, 1931.
-
(1931)
Ann. Math. Stat
, vol.2
, pp. 360-378
-
-
Hotelling, H.1
-
49
-
-
0037365160
-
Experimental determination of object statistics from noisy images
-
M. A. Kupinski, E. Clarkson, J. Hoppin, L. Chen, and H. H. Barrett, "Experimental determination of object statistics from noisy images," J. Opt. Soc. Amer., vol. 20, pp. 421-429, 2003.
-
(2003)
J. Opt. Soc. Amer
, vol.20
, pp. 421-429
-
-
Kupinski, M.A.1
Clarkson, E.2
Hoppin, J.3
Chen, L.4
Barrett, H.H.5
-
50
-
-
0016058340
-
Quantum noise in fresnel zone plate imaging
-
H. H. Barrett and G. D. DeMeester, "Quantum noise in fresnel zone plate imaging," Appl. Opt., vol. 13, no. 5, pp. 1100-1109, 1974.
-
(1974)
Appl. Opt
, vol.13
, Issue.5
, pp. 1100-1109
-
-
Barrett, H.H.1
DeMeester, G.D.2
-
51
-
-
0015680250
-
Fresnel zone plate imaging of gamma rays: Theory
-
H. H. Barrett and F. A. Horrigan, "Fresnel zone plate imaging of gamma rays: Theory," Appl. Opt., vol. 12, no. 11, pp. 2686-2702, 1973.
-
(1973)
Appl. Opt
, vol.12
, Issue.11
, pp. 2686-2702
-
-
Barrett, H.H.1
Horrigan, F.A.2
-
53
-
-
0025456621
-
Aperture optimization for emission imaging: Effect of a spatially varying back-ground
-
K. J. Myers, J. P. Rolland, H. H. Barrett, and R. F. Wagner, "Aperture optimization for emission imaging: Effect of a spatially varying back-ground," J. Opt. Soc. Am. A., vol. 7, no. 7, pp. 1279-1293, 1990.
-
(1990)
J. Opt. Soc. Am. A
, vol.7
, Issue.7
, pp. 1279-1293
-
-
Myers, K.J.1
Rolland, J.P.2
Barrett, H.H.3
Wagner, R.F.4
-
54
-
-
33947416035
-
Near-optimal signal recovery from random projections: Universal encoding strategies
-
Dec
-
E. J. Candes and T. Tao, "Near-optimal signal recovery from random projections: Universal encoding strategies," IEEE Trans. Inform. Theor., vol. 52, no. 12, pp. 5406-5425, Dec. 2006.
-
(2006)
IEEE Trans. Inform. Theor
, vol.52
, Issue.12
, pp. 5406-5425
-
-
Candes, E.J.1
Tao, T.2
-
55
-
-
0002712203
-
Maximum entropy and the nearly black object
-
D. L. Donoho, I. M. Johnstone, J. C. Hoch, and A. S. Stern, "Maximum entropy and the nearly black object," J. Roy. Stat. Soc., vol. B54, pp. 41-81, 1992.
-
(1992)
J. Roy. Stat. Soc
, vol.B54
, pp. 41-81
-
-
Donoho, D.L.1
Johnstone, I.M.2
Hoch, J.C.3
Stern, A.S.4
-
56
-
-
0032403053
-
Stabilized estimates of hotelling-observer detection performance in patient-structured noise
-
H. H. Barrett, C. Abbey, B. D. Gallas, and M. Eckstein, "Stabilized estimates of hotelling-observer detection performance in patient-structured noise," in Proc. SPIE, Med. Imag. 1998: Image Perception, 1998, vol. 3340, pp. 27-43.
-
(1998)
Proc. SPIE, Med. Imag. 1998: Image Perception
, vol.3340
, pp. 27-43
-
-
Barrett, H.H.1
Abbey, C.2
Gallas, B.D.3
Eckstein, M.4
-
57
-
-
0041761987
-
Validating the use of channels to estimate the ideal linear observer
-
B. D. Gallas and H. H. Barrett, "Validating the use of channels to estimate the ideal linear observer," J. Opt. Soc. Amer., vol. 20, pp. 1725-1739, 2003.
-
(2003)
J. Opt. Soc. Amer
, vol.20
, pp. 1725-1739
-
-
Gallas, B.D.1
Barrett, H.H.2
-
58
-
-
0022756448
-
Generalization of the matrix inversion lemma
-
Jul
-
D. J. Tylavsky and G. R. Sohie, "Generalization of the matrix inversion lemma," Proc. IEEE, vol. 74, no. 7, pp. 1050-1052, Jul. 1986.
-
(1986)
Proc. IEEE
, vol.74
, Issue.7
, pp. 1050-1052
-
-
Tylavsky, D.J.1
Sohie, G.R.2
-
59
-
-
33750386409
-
Calibration of scintillation cameras and pinhole SPECT imaging systems
-
M. Kupinski and H. Barrett, Eds. New York: Springer, ch. 12, pp
-
Y. C. Chen, D. W. Wilson, L. R. Furenlid, and H. H. Barrett, "Calibration of scintillation cameras and pinhole SPECT imaging systems," in Small-Animal SPECT Imag., M. Kupinski and H. Barrett, Eds. New York: Springer, 2005, ch. 12, pp. 195-201.
-
(2005)
Small-Animal SPECT Imag
, pp. 195-201
-
-
Chen, Y.C.1
Wilson, D.W.2
Furenlid, L.R.3
Barrett, H.H.4
-
60
-
-
33751248213
-
Using Fisher information to approximate ideal-observer performance on detection tasks for lumpy-background images
-
F. Shen and E. Clarkson, "Using Fisher information to approximate ideal-observer performance on detection tasks for lumpy-background images," J. Opt. Soc. Amer., vol. 23, pp. 2406-2414, 2006.
-
(2006)
J. Opt. Soc. Amer
, vol.23
, pp. 2406-2414
-
-
Shen, F.1
Clarkson, E.2
-
61
-
-
35148889859
-
Estimation ROC curves and their corresponding ideal observers
-
E. Clarkson, "Estimation ROC curves and their corresponding ideal observers," in Proc. SPIE, 2007, vol. 6515, p. 651504.
-
(2007)
Proc. SPIE
, vol.6515
, pp. 651504
-
-
Clarkson, E.1
|