Volumn 59, Issue 5, 2012, Pages 1199-1204

Deep tissue photoacoustic imaging using a miniaturized 2-D capacitive micromachined ultrasonic transducer array

Author keywords

Capacitive micromachined ultrasound transducer (CMUT) array; deep tissue imaging; optoacoustic; photoacoustic

Indexed keywords

A-CENTER; CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCER; CAPACITIVE MICROMACHINED ULTRASOUND TRANSDUCER; DEEP TISSUE IMAGING; DEPTH SENSITIVITY; EXPERIMENTAL CONDITIONS; FRONT-END AMPLIFIER; INDOCYANINE GREEN DYE; OPTOACOUSTIC; PHOTO-ACOUSTIC IMAGING; PHOTOACOUSTIC; SPATIAL RESOLUTION; TOMOGRAPHIC IMAGES; VOLUMETRIC IMAGES;

EID: 84860375827     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2012.2183593     Document Type: Article
Times cited : (79)

References (21)
  • 1
    • 69949158591 scopus 로고    scopus 로고
    • Multiscale photoacoustic microscopy and computed tomography
    • L. V.Wang, "Multiscale photoacoustic microscopy and computed tomography," Nat. Photon., vol. 3, pp. 503-509, 2009.
    • (2009) Nat. Photon. , vol.3 , pp. 503-509
    • Wang, L.V.1
  • 4
    • 75749085451 scopus 로고    scopus 로고
    • Development of a catheter for combined intravascular ultrasound and photoacoustic imaging
    • 014901 1- 014901:7
    • A.B.Karpiouk, B.Wang, and S.Y. Emelianov, "Development of a catheter for combined intravascular ultrasound and photoacoustic imaging," Rev. Sci. Instrum., vol. 81, pp. 014901:1-014901:7, 2010.
    • (2010) Rev. Sci. Instrum. , vol.81
    • Karpiouk, A.B.1    Wang, B.2    Emelianov, S.Y.3
  • 6
    • 77955513383 scopus 로고    scopus 로고
    • Photoacoustic imaging of the breast using the twente photoacoustic mammoscope: Present status and future perspectives
    • Jul./Aug.
    • D. Piras, X. Wenfeng, W. Steenbergen, T.G. van Leeuwen, and S. G. Manohar, "Photoacoustic imaging of the breast using the twente photoacoustic mammoscope: Present status and future perspectives," IEEE J. Sel. Topics Quant. Elect., vol. 16, no. 4, pp. 730-739, Jul./Aug. 2010.
    • (2010) IEEE J. Sel. Topics Quant. Elect. , vol.16 , Issue.4 , pp. 730-739
    • Piras, D.1    Wenfeng, X.2    Steenbergen, W.3    Van Leeuwen, T.G.4    Manohar, S.G.5
  • 7
    • 63649150845 scopus 로고    scopus 로고
    • In vivo highresolution 3D photoacoustic imaging of superficial vascular anatomy
    • E. Z. Zhang, J. G. Laufer, R. B. Pedley, and P. C. Beard, "In vivo highresolution 3D photoacoustic imaging of superficial vascular anatomy," Phy. Med. Biol., vol. 54, pp. 1035-1046, 2009.
    • (2009) Phy. Med. Biol. , vol.54 , pp. 1035-1046
    • Zhang, E.Z.1    Laufer, J.G.2    Pedley, R.B.3    Beard, P.C.4
  • 10
    • 79951628480 scopus 로고    scopus 로고
    • Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system
    • C. Kim, T.N. Erpelding, L. Jankovic, M. D. Pashley, and L. V. Wang, "Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system," Biomed. Opt. Exp., vol. 1, pp. 278-284, 2010.
    • (2010) Biomed. Opt. Exp. , vol.1 , pp. 278-284
    • Kim, C.1    Erpelding, T.N.2    Jankovic, L.3    Pashley, M.D.4    Wang, L.V.5
  • 11
    • 14844331422 scopus 로고    scopus 로고
    • Deeply penetrating photoacoustic tomography in biological tissues enhanced with an optical contrast agent
    • DOI 10.1364/OL.30.000507
    • G. Ku and L.V. Wang, "Deeply penetrating photoacoustic tomography in biological tissues enhanced with an optical contrast agent," Opt. Lett., vol. 30, pp. 507-509, 2005. (Pubitemid 40339495)
    • (2005) Optics Letters , vol.30 , Issue.5 , pp. 507-509
    • Ku, G.1    Wang, L.V.2
  • 14
    • 0032162663 scopus 로고    scopus 로고
    • The microfabrication of capacitive ultrasonic transducers
    • PII S105771579806346X
    • X. Jin, I. Ladabaum, and B.T. Khuri-Yakub, "The microfabrication of capacitive ultrasonic transducers," J. Microelectromech. Syst, vol. 7, pp. 295-302, 1998. (Pubitemid 128611226)
    • (1998) Journal of Microelectromechanical Systems , vol.7 , Issue.3 , pp. 295-302
    • Jin, X.1    Ladabaum, I.2    Khuri-Yakub, B.T.3
  • 16
    • 0033888678 scopus 로고    scopus 로고
    • Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: A comparison with PVDF needle and membrane hydrophones
    • DOI 10.1109/58.818769
    • P. C. Beard, A. M. Hurrell, and T. N. Mills, "Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: A comparison with PVDF needle and membrane hydrophones," IEEE Trans. Ultrason., Ferroelectr. Freq. Cont., vol. 47, no. 1, pp. 256-264, Jan. 2000. (Pubitemid 30553560)
    • (2000) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control , vol.47 , Issue.1 , pp. 256-264
    • Beard, P.C.1    Hurrell, A.M.2    Mills, T.N.3
  • 20
    • 9144245647 scopus 로고    scopus 로고
    • Optoacoustic imaging with synthetic aperture focusing and coherence weighting
    • C.-K. Liao, M.-L. Li, and P.-C. Li, "Optoacoustic imaging with synthetic aperture focusing and coherence weighting," Opt. Lett, vol. 29, pp. 2506- 2508, 2004.
    • (2004) Opt. Lett. , vol.29 , pp. 2506-2508
    • Liao, C.-K.1    Li, M.-L.2    Li, P.-C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.