메뉴 건너뛰기




Volumn 2, Issue , 2011, Pages 623-627

Energy efficient data centers using evaporative cooling and air side economizers

Author keywords

[No Author keywords available]

Indexed keywords

AIR INLET TEMPERATURE; AIR SIDES; AIR STREAMS; AIR TEMPERATURE; CHILLER PLANTS; COMPUTER EQUIPMENTS; COMPUTER ROOM AIR CONDITIONING; COOLING LOOPS; DATA CENTER COOLING; DATA CENTERS; ENERGY EFFICIENT; ENERGY USE; EVAPORATIVE COOLING; HOT CLIMATE; OUTDOOR AIR; OUTDOOR-AIR TEMPERATURE; PARTICULATE FILTRATION; PSYCHOMETRIC CHARTS; SUBSTANTIAL ENERGY; WATER EVAPORATION;

EID: 84860334096     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1115/IPACK2011-52210     Document Type: Conference Paper
Times cited : (6)

References (12)
  • 1
    • 84860316464 scopus 로고    scopus 로고
    • Release date full report: June 2008, Next release date full report: February 2009
    • Report by the US energy Information, Report #:DOE/EIA-0383(2008), Release date full report: June 2008, Next release date full report: February 2009
    • (2008) Report by the US Energy Information, Report #:DOE/EIA-0383
  • 2
    • 84885314104 scopus 로고    scopus 로고
    • U.S. Environmental Protection Agency ENERGY STAR Program August 2
    • Report to Congress on Server and Data Center Energy Efficiency Public Law 109-431 U.S. Environmental Protection Agency ENERGY STAR Program August 2, 2007 http://www.energystar.gov/ia/partners/prod-development/downloads/EPA- Datacenter-Report-Congress-Final1.pdf
    • (2007) Report to Congress on Server and Data Center Energy Efficiency Public Law 109-431
  • 3
    • 77955184435 scopus 로고    scopus 로고
    • Reducing energy usage in data centers through control of room air conditioning units
    • Las Vegas, USA
    • M. Iyengar, R. Schmidt, and J. Caricari, 2010, "Reducing Energy Usage in Data Centers through Control of Room Air Conditioning units", Proceedings of the IEEE ITherm conf., Las Vegas, USA.
    • (2010) Proceedings of the IEEE ITherm Conf.
    • Iyengar, M.1    Schmidt, R.2    Caricari, J.3
  • 4
    • 40449106252 scopus 로고    scopus 로고
    • In the data center, power and cooling costs more than the IT equipment it supports
    • February
    • C. Belady, 2007, "In the Data Center, Power and Cooling Costs More than the IT Equipment It Supports," ElectronicsCooling, Vol. 13, No 1, February.
    • (2007) ElectronicsCooling , vol.13 , Issue.1
    • Belady, C.1
  • 6
    • 77955072447 scopus 로고    scopus 로고
    • Thermodynamics of information technology data centers
    • Paper 9
    • R. Schmidt and M. Iyengar, 2009, "Thermodynamics of Information Technology Data Centers", IBM J. Res. & Dev. Vol. 53, No. 3, Paper 9.
    • (2009) IBM J. Res. & Dev. , vol.53 , Issue.3
    • Schmidt, R.1    Iyengar, M.2
  • 7
    • 84860327178 scopus 로고    scopus 로고
    • Munters Corporation Presentation at NY
    • Don Delman, Munters Corporation, 2010 Presentation at IBM in Poughkeepsie, NY.
    • (2010) IBM in Poughkeepsie
    • Delman, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.