메뉴 건너뛰기




Volumn 6, Issue , 2009, Pages 1-107

The datacenter as a computer: An introduction to the design of warehouse-scale machines

Author keywords

Cloud computing; Cluster computing; Computer organization and design; Data centers; Distributed systems; Energy efficiency; Fault tolerant computing; Internet services

Indexed keywords

CLOUD COMPUTING; COMPUTER ORGANIZATION AND DESIGN; DATA CENTERS; DISTRIBUTED SYSTEMS; FAULT-TOLERANT COMPUTING; INTERNET SERVICES;

EID: 67649170859     PISSN: 19353235     EISSN: 19353243     Source Type: Book Series    
DOI: 10.2200/S00193ED1V01Y200905CAC006     Document Type: Article
Times cited : (397)

References (90)
  • 2
    • 70450082834 scopus 로고    scopus 로고
    • Reducing datacenter costs with an air economizer
    • August
    • D. Atwood and J. G. Miner, "Reducing datacenter costs with an air economizer," IT@Intel Brief, August 2008.
    • (2008) IT@Intel Brief
    • Atwood, D.1    Miner, J.G.2
  • 3
    • 67649185552 scopus 로고    scopus 로고
    • L. N. Bairavasundaram, G. R. Goodson, S. Pasupathy, and J. Schindler, An analysis of latent sector errors in disk drives, in Proceedings of the 2007 ACM SIGMETRICS international Conference on Measurement and Modeling of Computer Systems, San Diego, CA, June 12-16, 2007. SIGMETRICS '07. doi:10.1145/1254882.1254917
    • L. N. Bairavasundaram, G. R. Goodson, S. Pasupathy, and J. Schindler, "An analysis of latent sector errors in disk drives," in Proceedings of the 2007 ACM SIGMETRICS international Conference on Measurement and Modeling of Computer Systems, San Diego, CA, June 12-16, 2007. SIGMETRICS '07. doi:10.1145/1254882.1254917
  • 4
    • 70449462461 scopus 로고    scopus 로고
    • P. Barham, B. Dragovic, K. Fraser, S. Hand, T. Harris, A. Ho, R. Neugebauer, I. Pratt, and A. Warfeld, Xen and the art of virtualization, in Proceedings of the Nineteenth ACM Symposium on Operating Systems Principles, Bolton Landing, NY, October 19-22, 2003. SOSP '03. doi:10.1145/945445.945462
    • P. Barham, B. Dragovic, K. Fraser, S. Hand, T. Harris, A. Ho, R. Neugebauer, I. Pratt, and A. Warfeld, "Xen and the art of virtualization," in Proceedings of the Nineteenth ACM Symposium on Operating Systems Principles, Bolton Landing, NY, October 19-22, 2003. SOSP '03. doi:10.1145/945445.945462
  • 5
    • 0037619265 scopus 로고    scopus 로고
    • Web search for a planet: The architecture of the Google cluster
    • April, doi:10.1109/MM.2003.1196112
    • L. Barroso, J. Dean, and U. Hölzle, "Web search for a planet: the architecture of the Google cluster," IEEE Micro, April 2003. doi:10.1109/MM.2003.1196112
    • (2003) IEEE Micro
    • Barroso, L.1    Dean, J.2    Hölzle, U.3
  • 6
    • 47249127725 scopus 로고    scopus 로고
    • The case for energy-proportional computing
    • Dec
    • L. A. Barroso and U. Hölzle, "The case for energy-proportional computing," IEEE Computer, vol. 40, no. 12 (Dec. 2007).
    • (2007) IEEE Computer , vol.40 , Issue.12
    • Barroso, L.A.1    Hölzle, U.2
  • 10
    • 0035390859 scopus 로고    scopus 로고
    • Lessons from giant - scale services
    • July/Aug, doi:10.1109/4236.939450
    • E. A. Brewer, "Lessons from giant - scale services," IEEE Internet Computing, vol. 5, no. 4 ( July/Aug. 2001), pp. 46-55. doi:10.1109/4236.939450
    • (2001) IEEE Internet Computing , vol.5 , Issue.4 , pp. 46-55
    • Brewer, E.A.1
  • 11
    • 0346634163 scopus 로고    scopus 로고
    • E. V. Carrera, E. Pinheiro, and R. Bianchini, Conserving disk energy in network servers, in Proceedings of the 17th Annual International Conference on Supercomputing, San Francisco, CA, June 23-26, 2003. ICS '03. doi:10.1145/782814.782829
    • E. V. Carrera, E. Pinheiro, and R. Bianchini, "Conserving disk energy in network servers," in Proceedings of the 17th Annual International Conference on Supercomputing, San Francisco, CA, June 23-26, 2003. ICS '03. doi:10.1145/782814.782829
  • 15
    • 70450256454 scopus 로고    scopus 로고
    • Energy aware server provisioning and load dispatching for connection-intensive Internet services,
    • MSR-TR-2007-130, 2007
    • G. Chen, W. He, J. Liu, S. Nath, L. Rigas, L. Xiao, and F. Zhao, "Energy aware server provisioning and load dispatching for connection-intensive Internet services," Microsoft Research Technical Report MSR-TR-2007-130, 2007.
    • Microsoft Research Technical Report
    • Chen, G.1    He, W.2    Liu, J.3    Nath, S.4    Rigas, L.5    Xiao, L.6    Zhao, F.7
  • 16
    • 33947704798 scopus 로고    scopus 로고
    • Managing server energy and operational costs in hosting centers
    • Banff, Alberta, Canada, June, doi:10.1145/1064212.1064253
    • Y. Chen, A. Das, W. Qin, A. Sivasubramaniam, Q. Wang, and N. Gautam, "Managing server energy and operational costs in hosting centers," in Proceedings of the ACM SIG-METRICS '05, Banff, Alberta, Canada, June 2005. doi:10.1145/1064212.1064253
    • (2005) Proceedings of the ACM SIG-METRICS '05
    • Chen, Y.1    Das, A.2    Qin, W.3    Sivasubramaniam, A.4    Wang, Q.5    Gautam, N.6
  • 18
    • 19444374983 scopus 로고    scopus 로고
    • Improved muscular effciency displayed as tour de France champion matures
    • Mar, doi:10.1152/japplphysiol.00216
    • E. F. Coyle, "Improved muscular effciency displayed as tour de France champion matures," Journal of Applied Physiology, Mar. 2005. doi:10.1152/japplphysiol.00216.2005
    • (2005) Journal of Applied Physiology
    • Coyle, E.F.1
  • 19
    • 37549003336 scopus 로고    scopus 로고
    • MapReduce: Simplifed data processing on large clusters
    • J. Dean and S. Ghemawat, "MapReduce: simplifed data processing on large clusters," Communications of the ACM, vol. 51, no. 1 (2008), pp. 107-113.
    • (2008) Communications of the ACM , vol.51 , Issue.1 , pp. 107-113
    • Dean, J.1    Ghemawat, S.2
  • 21
  • 22
    • 67649197646 scopus 로고    scopus 로고
    • T. J. Dell, A white paper on the benefts of chipkill-correct ECC for PC server main memory, IBM Microelectronics Division, Rev 11/19/1997.
    • T. J. Dell, "A white paper on the benefts of chipkill-correct ECC for PC server main memory," IBM Microelectronics Division, Rev 11/19/1997.
  • 23
    • 67649233369 scopus 로고    scopus 로고
    • Current trends/challenges in datacenter thermal management-a facilities perspective
    • San Diego, CA, June 1
    • D. Dyer, "Current trends/challenges in datacenter thermal management-a facilities perspective," presentation at ITHERM, San Diego, CA, June 1, 2006.
    • (2006) presentation at ITHERM
    • Dyer, D.1
  • 25
    • 67649233366 scopus 로고    scopus 로고
    • Dupont Fabros Technology Inc. SEC Filing (S-11) 333-145294, August 9
    • Dupont Fabros Technology Inc. SEC Filing (S-11) 333-145294, August 9, 2007.
    • (2007)
  • 26
    • 57049182063 scopus 로고    scopus 로고
    • Report to Congress on server and datacenter energy effciency
    • U.S. Environmental Protection Agency, August 2
    • U.S. Environmental Protection Agency, "Report to Congress on server and datacenter energy effciency," Public Law 109-431, August 2, 2007.
    • (2007) Public Law , vol.109-431
  • 27
    • 35348835964 scopus 로고    scopus 로고
    • X. Fan, W. Weber, and L. A. Barroso, Power provisioning for a warehouse-sized computer, in Proceedings of the 34th Annual International Symposium on Computer Architecture, San Diego, CA, June 09-13, 2007. ISCA '07. doi:10.1145/1250662.1250665
    • X. Fan, W. Weber, and L. A. Barroso, "Power provisioning for a warehouse-sized computer," in Proceedings of the 34th Annual International Symposium on Computer Architecture, San Diego, CA, June 09-13, 2007. ISCA '07. doi:10.1145/1250662.1250665
  • 33
    • 67649233347 scopus 로고    scopus 로고
    • Google Inc, April 2009. Available at
    • Google Inc., "Effcient Data Center Summit, April 2009". Available at http://www.google .com/corporate/green/datacenters/summit.html.
    • Effcient Data Center Summit
  • 34
    • 67649211054 scopus 로고    scopus 로고
    • Google Inc., Effcient Data Center, Part 1. Available at http://www.youtube.com/ watch?v=Ho1GEyftpmQ , starting at 0:5930.
    • Google Inc., "Effcient Data Center, Part 1". Available at http://www.youtube.com/ watch?v=Ho1GEyftpmQ , starting at 0:5930.
  • 35
    • 67649210557 scopus 로고    scopus 로고
    • A census of tandem system availability between 1985 and 1990,
    • 90.1, January 1990
    • J. Gray, "A census of tandem system availability between 1985 and 1990," Tandem Technical Report 90.1, January 1990.
    • Tandem Technical Report
    • Gray, J.1
  • 36
    • 84885290434 scopus 로고    scopus 로고
    • Available at
    • The Green 500. Available at http://www.green500.org.
    • The Green 500
  • 40
    • 67649205474 scopus 로고    scopus 로고
    • SNIA Green Storage Initiative. Available at
    • SNIA Green Storage Initiative. Available at http://www.snia.org/forums/ green/.
  • 42
    • 67649199289 scopus 로고    scopus 로고
    • The Hadoop Project. Available at
    • The Hadoop Project. Available at http://hadoop.apache.org
  • 43
    • 84896814982 scopus 로고    scopus 로고
    • On designing and deploying internet-scale services
    • J. Hamilton, "On designing and deploying internet-scale services," in Proceedings of USE-NIX LISA, 2007.
    • (2007) Proceedings of USE-NIX LISA
    • Hamilton, J.1
  • 44
    • 84858671115 scopus 로고    scopus 로고
    • Cooperative expendable micro-slice servers (CEMS): Low cost, low power servers for internet-scale services
    • Asilomar, CA, January 4-7
    • J. Hamilton, "Cooperative expendable micro-slice servers (CEMS): low cost, low power servers for internet-scale services," in Proceedings of the 4th Biennial Conference on Innovative Data Systems Research (CIDR), Asilomar, CA, January 4-7, 2009.
    • (2009) Proceedings of the 4th Biennial Conference on Innovative Data Systems Research (CIDR)
    • Hamilton, J.1
  • 46
    • 67649211060 scopus 로고    scopus 로고
    • Available at
    • HP Power Calculator. Available at http://www.hp.com/confgurator/ powercalcs.asp.
    • Power Calculator, H.P.1
  • 48
    • 71749096263 scopus 로고    scopus 로고
    • Autopilot: Automatic datacenter management
    • Apr, DOI: http:///10.1145/1243418.1243426
    • M. Isard, "Autopilot: automatic datacenter management". SIGOPS Operating Systems Review, vol. 41, no. 2 (Apr. 2007), pp. 60-67. DOI: http://doi.acm.org/10.1145/1243418.1243426.
    • (2007) SIGOPS Operating Systems Review , vol.41 , Issue.2 , pp. 60-67
    • Isard, M.1
  • 49
    • 0033344278 scopus 로고    scopus 로고
    • M. Kalyanakrishnam, Z. Kalbarczyk, and R. Iyer, Failure data analysis of a LAN of Windows NT based computers, Reliable Distributed Systems, IEEE Symposium on, 0, no. 0, pp. 178, 18th IEEE Symposium on Reliable Distributed Systems, 1999. doi:10.1109/ RELDIS.1999.805094
    • M. Kalyanakrishnam, Z. Kalbarczyk, and R. Iyer, "Failure data analysis of a LAN of Windows NT based computers," Reliable Distributed Systems, IEEE Symposium on, vol. 0, no. 0, pp. 178, 18th IEEE Symposium on Reliable Distributed Systems, 1999. doi:10.1109/ RELDIS.1999.805094
  • 50
    • 52749085695 scopus 로고    scopus 로고
    • K. Lim, P. Ranganathan, J. Chang, C. Patel, T. Mudge, and S. Reinhardt, Understanding and designing new server architectures for emerging warehouse-computing environments, Computer Architecture, International Symposium on, 0, no. 0, pp. 315-326, 2008 International Symposium on Computer Architecture, 2008. doi:10.1145/1394608.1382148
    • K. Lim, P. Ranganathan, J. Chang, C. Patel, T. Mudge, and S. Reinhardt, "Understanding and designing new server architectures for emerging warehouse-computing environments," Computer Architecture, International Symposium on, vol. 0, no. 0, pp. 315-326, 2008 International Symposium on Computer Architecture, 2008. doi:10.1145/1394608.1382148
  • 51
    • 34347366227 scopus 로고    scopus 로고
    • Metrics to characterize datacenter & IT equipment energy use
    • Richardson, TX, September
    • C. Malone and C. Belady, "Metrics to characterize datacenter & IT equipment energy use," in Proceedings of the Digital Power Forum, Richardson, TX, September 2006.
    • (2006) Proceedings of the Digital Power Forum
    • Malone, C.1    Belady, C.2
  • 61
    • 67649207929 scopus 로고    scopus 로고
    • M. K. Patterson and D. Fenwick, The state of datacenter cooling, Intel Corporation White Paper. Available at http://download. intel.com/technology/eep/data-center-effciency/state-of-date-center-cool ing.pdf.
    • M. K. Patterson and D. Fenwick, "The state of datacenter cooling," Intel Corporation White Paper. Available at http://download. intel.com/technology/eep/data-center-effciency/state-of-date-center-cooling.pdf.
  • 64
    • 67649210559 scopus 로고    scopus 로고
    • amp;E, High performance datacenters. Available at http://hightech.lbl.gov/documents/ DATA-CENTERS/06-DataCenters-PGE.pdf.
    • PG&E, "High performance datacenters". Available at http://hightech.lbl.gov/documents/ DATA-CENTERS/06-DataCenters-PGE.pdf.
  • 65
    • 67649185550 scopus 로고    scopus 로고
    • W. Pitt Turner IV, J. H. Seader, and K. G. Brill, Tier classifcations defne site infrastructure performance, Uptime Institute White Paper.
    • W. Pitt Turner IV, J. H. Seader, and K. G. Brill, "Tier classifcations defne site infrastructure performance," Uptime Institute White Paper.
  • 66
    • 67649214235 scopus 로고    scopus 로고
    • W. Pitt Turner IV and J. H. Seader, Dollars per kW plus dollars per square foot are a better datacenter cost model than dollars per square foot alone, Uptime Institute White Paper, 2006.
    • W. Pitt Turner IV and J. H. Seader, "Dollars per kW plus dollars per square foot are a better datacenter cost model than dollars per square foot alone," Uptime Institute White Paper, 2006.
  • 68
    • 67649236451 scopus 로고    scopus 로고
    • Dupont Fabros Technology, Inc
    • November 5
    • Reuters, "Dupont Fabros Technology, Inc. reports third quarter results," November 5, 2008.
    • (2008) reports third quarter results
    • Reuters1
  • 71
    • 27744585747 scopus 로고    scopus 로고
    • Robert Frances Group, July 2002. Available at
    • Robert Frances Group, "Total cost of ownership for Linux in the enterprise," July 2002. Available at http://www-03.ibm.com/linux/RFG- LinuxTCO-vFINAL-Jul2002.pdf.
    • Total cost of ownership for Linux in the enterprise
  • 72
    • 67649236449 scopus 로고    scopus 로고
    • SAVVIS press release, June 29, 2007. Available at
    • SAVVIS press release, "SAVVIS sells assets related to two datacenters for $200 million," June 29, 2007. Available at http://www.savvis.net/corp/News/Press+Releases/Archive/SAVVIS+ Sells+Assets+Related+to+Two+Data+Centers+for+200+Million.htm.
    • SAVVIS sells assets related to two datacenters for $200 million
  • 73
    • 36148941068 scopus 로고    scopus 로고
    • Understanding failures in petascale computers
    • Journal of Physics:, doi:10.1088/1742-6596/78/1/012022
    • B. Schroeder and G. A. Gibson, "Understanding failures in petascale computers," Journal of Physics: Conference Series 78 (2007). doi:10.1088/1742-6596/78/1/012022
    • (2007) Conference Series , vol.78
    • Schroeder, B.1    Gibson, G.A.2
  • 77
    • 67649211058 scopus 로고    scopus 로고
    • SPEC Power. Available at http://www.spec.org/power-ssj2008/.
    • SPEC Power. Available at http://www.spec.org/power-ssj2008/.
  • 78
    • 64349107705 scopus 로고    scopus 로고
    • Models and metrics to enable energy-effciency optimizations
    • Dec
    • S. Rivoire, M. A. Shah, P. Ranganathan, C. Kozyrakis, and Justin Meza, "Models and metrics to enable energy-effciency optimizations," Computer, vol. 40, no. 12 (Dec. 2007), pp. 39-48.
    • (2007) Computer , vol.40 , Issue.12 , pp. 39-48
    • Rivoire, S.1    Shah, M.A.2    Ranganathan, P.3    Kozyrakis, C.4    Meza, J.5
  • 79
    • 52649144419 scopus 로고    scopus 로고
    • S. Sankar, S. Gurumurthi, and M. R. Stan, Intra-disk parallelism: an idea whose time has come, in Proceedings of the ACM International Symposium on Computer Architecture, June 2008, pp. 303-314.
    • S. Sankar, S. Gurumurthi, and M. R. Stan, "Intra-disk parallelism: an idea whose time has come," in Proceedings of the ACM International Symposium on Computer Architecture, June 2008, pp. 303-314.
  • 80
    • 67649220924 scopus 로고    scopus 로고
    • Techarp.com, Intel desktop CPU guide. Available at http://www.techarp.com/showarticle. aspx?artno=337&pgno=6.
    • Techarp.com, "Intel desktop CPU guide". Available at http://www.techarp.com/showarticle. aspx?artno=337&pgno=6.
  • 81
    • 67649210562 scopus 로고    scopus 로고
    • Terrazon Semiconductor, Soft errors in electronic memory - a white paper. Available at http://www.tezzaron.com/about/papers/soft-errors-1-1- secure.pdf.
    • Terrazon Semiconductor, "Soft errors in electronic memory - a white paper". Available at http://www.tezzaron.com/about/papers/soft-errors-1-1- secure.pdf.
  • 83
    • 67649170700 scopus 로고    scopus 로고
    • Transaction Processing Performance Council. Available at
    • Transaction Processing Performance Council. Available at http://www.tpc.org.
  • 85
    • 67649211056 scopus 로고    scopus 로고
    • TPC-C Executive summary for the Superdome-Itanium2, February
    • TPC-C Executive summary for the Superdome-Itanium2, February 2007.
    • (2007)
  • 86
    • 67649197644 scopus 로고    scopus 로고
    • TPC-C Executive summary for the ProLiant ML350G5, September
    • TPC-C Executive summary for the ProLiant ML350G5, September 2007.
    • (2007)
  • 88
    • 78651556127 scopus 로고    scopus 로고
    • Eventually consistent
    • October, Available at
    • W. Vogels, "Eventually consistent," ACM Queue, October 2008. Available at http://queue .acm.org/detail.cfm?id=1466448.
    • (2008) ACM Queue
    • Vogels, W.1
  • 89
    • 84978369624 scopus 로고    scopus 로고
    • B. Chandra, M. Dahlin, L. Gao, A.-A. Khoja, A .Nayate, A. Razzaq, and A. Sewani, Resource management for scalable disconnected access to Web services, Proceedings of the 10th International Conference on World Wide Web, Hong Kong, Hong Kong, May 1-5, 2001, pp. 245-256.
    • B. Chandra, M. Dahlin, L. Gao, A.-A. Khoja, A .Nayate, A. Razzaq, and A. Sewani, "Resource management for scalable disconnected access to Web services," Proceedings of the 10th International Conference on World Wide Web, Hong Kong, Hong Kong, May 1-5, 2001, pp. 245-256.
  • 90
    • 67649197643 scopus 로고    scopus 로고
    • Microsoft's Top 10 Business Practices for Environmentally Sustainable Data Center. Available at
    • "Microsoft's Top 10 Business Practices for Environmentally Sustainable Data Center." Available at http://www.microsoft.com/ environment/our-commitment/articles/datacenter-bp.aspx.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.