Reducing energy usage in data centers through control of room air conditioning units

Author keywords

Cooling; Data center; Energy efficiency; Raised floor; Thermal management

Indexed keywords

AIR TEMPERATURE; AIR TEMPERATURE FIELDS; CFD ANALYSIS; CHILLER PLANTS; COMMERCIAL SOFTWARE; COMPUTER ROOM AIR CONDITIONING; CONDITIONING UNITS; COOLING DATA; COOLING ENERGY; DATA CENTER; DATA CENTER COOLING; DATA CENTERS; DESIGN CONDITION; ENERGY USAGE; ENERGY USE; EQUIPMENT INFORMATION; INLET AIR TEMPERATURES; MOTOR SPEED; ROOM AIR; SET-POINT; SYSTEMATIC METHODOLOGY; TEST CASE; THERMAL MANAGEMENT; UPPER AND LOWER BOUNDS; VOLUMETRIC AIR FLOW RATE;

EID: 77955184435     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ITHERM.2010.5501418     Document Type: Conference Paper
Times cited : (58)

References (16)
  • 4
    • 77955225259 scopus 로고    scopus 로고
    • Report by the US energy Information Administration, Report #:DOE/EIA-0383
    • "Annual Energy Outlook for 2008 with Projections to 2030", Report by the US energy Information Administration, Report #:DOE/EIA-0383, 2008, http://www.eia.doe.gov/oiaf/archive/aeo08/electricity.html
    • (2008) Annual Energy Outlook for 2008 with Projections to 2030
  • 5
    • 77955197355 scopus 로고    scopus 로고
    • Challenges & Opportunities in Data Center Thermal & Energy Efficiency Management- An Industry" Perspective
    • Tutorial presentation at the
    • th.
    • (2009) th
    • Schmidt, R.1    Iyengar, M.2
  • 6
    • 77953919096 scopus 로고    scopus 로고
    • Best Practices Identified Through Benchmarking Data Centers
    • Presentation at the
    • W. Tschudi, 2006, "Best Practices Identified Through Benchmarking Data Centers," Presentation at the ASHRAE Summer Conference, Quebec City, Canada, June.
    • (2006) ASHRAE Summer Conference, Quebec City, Canada, June
    • Tschudi, W.1
  • 8
    • 33749318004 scopus 로고    scopus 로고
    • Liebert Deluxe System/3® Chilled Water Systems, Emerson Network Power
    • Liebert Deluxe System/3® Chilled Water Systems, Technical Data Manual, Emerson Network Power.
    • Technical Data Manual
  • 10
    • 84885240959 scopus 로고    scopus 로고
    • Software manufactured by Innovative Research Inc., Plymouth, Minnesota, USA
    • TileFlow v4.0, Software manufactured by Innovative Research Inc., Plymouth, Minnesota, USA, http://www.inres.com/Products/TileFlow/tileflow.html,
    • TileFlow V4.0
  • 14
    • 77955194384 scopus 로고    scopus 로고
    • Personal communications with Dave Kelly, Liebert
    • Personal communications with Dave Kelly, Liebert.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.