-
1
-
-
46149117041
-
Response to high-energy photons of PTW31014 PinPoint ion chamber with a central aluminum electrode
-
DOI 10.1118/1.2940190
-
Agostinelli S, Garelli S, Piergentili M and Foppiano F 2008 Response to high-energy photons of PTW31014 PinPoint ion chamber with a central aluminum electrode Med. Phys. 35 3293301 (Pubitemid 351904533)
-
(2008)
Medical Physics
, vol.35
, Issue.7
, pp. 3293-3301
-
-
Agostinelli, S.1
Garelli, S.2
Piergentili, M.3
Foppiano, F.4
-
2
-
-
0032874911
-
AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
-
DOI 10.1118/1.598691
-
Almond P R et al 1999 AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams Med. Phys. 26 184770 (Pubitemid 29442268)
-
(1999)
Medical Physics
, vol.26
, Issue.9
, pp. 1847-1870
-
-
Almond, P.R.1
Biggs, P.J.2
Coursey, B.M.3
Hanson, W.F.4
Huq, M.S.5
Nath, R.6
Rogers, D.W.O.7
-
3
-
-
0004116648
-
-
ed F H Attix and W C Roesch (New York: Academic) chap 9
-
Boag J W 1966 Ionization chambers Radiation Dosimetry vol II ed F H Attix and W C Roesch (New York: Academic) chap 9
-
(1966)
Ionization Chambers Radiation Dosimetry
, vol.2
-
-
Boag, J.W.1
-
4
-
-
0018832381
-
Current collection and ionic recombination in small cylindrical ionization chambers exposed to pulsed radiation
-
Boag J W and Currant J 1980 Current collection and ionic recombination in small cylindrical ionization chambers exposed to pulsed radiation Br. J. Radiol. 53 4718 (Pubitemid 10149588)
-
(1980)
British Journal of Radiology
, vol.53
, Issue.629
, pp. 471-478
-
-
Boag, J.W.1
Currant, J.2
-
5
-
-
33947717382
-
S for some specific plane-parallel and cylindrical ionization chambers in pulsed photon and electron beams
-
DOI 10.1088/0031-9155/52/2/N01, PII S0031915507289237, N01
-
Bruggmoser G, Saum R, Schmachtenberg A, Schmid F and Schüle E 2007 Determination of the recombination correction factor ks for specific plane-parallel and cylindrical ionization chambers in pulsed photon and electron beams Phys. Med. Biol. 52 N3550 (Pubitemid 46646469)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.2
-
-
Bruggmoser, G.1
Saum, R.2
Schmachtenberg, A.3
Schmid, F.4
Schule, E.5
-
6
-
-
0025361288
-
Saturation correction for the NE 2560/1 dosemeter in photon dosimetry
-
Burns J E and Rosser K E 1990 Saturation correction for the NE 2560/1 dosemeter in photon dosimetry Phys. Med. Biol. 35 68793 (Pubitemid 20130936)
-
(1990)
Physics in Medicine and Biology
, vol.35
, Issue.5
, pp. 687-693
-
-
Burns, J.E.1
Rosser, K.E.2
-
7
-
-
42449146199
-
The characterization of unflattened photon beams from a 6 MV linear accelerator
-
DOI 10.1088/0031-9155/53/7/009, PII S0031915508667275
-
Cashmore J 2008 The characterization of unflattened photon beams from a 6 MV linear accelerator Phys. Med. Biol. 53 193346 (Pubitemid 351570900)
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.7
, pp. 1933-1946
-
-
Cashmore, J.1
-
8
-
-
2642710922
-
Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams
-
DOI 10.1088/0031-9155/43/1/002, PII S0031915598852640
-
Dasu A, Löfroth P-O and Wickman G 1998 Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams Phys. Med. Biol. 43 2136 (Pubitemid 28103708)
-
(1998)
Physics in Medicine and Biology
, vol.43
, Issue.1
, pp. 21-36
-
-
Dasu, A.1
Lofroth, P.-O.2
Wickman, G.3
-
9
-
-
0034036230
-
Saturation current and collection efficiency for ionization chambers in pulsed beams
-
DOI 10.1118/1.598992
-
DeBlois F, Zankowski C and Podgorsak E B 2000 Saturation current and collection efficiency for ionization chambers in pulsed beams Med. Phys. 27 114655 (Pubitemid 30350028)
-
(2000)
Medical Physics
, vol.27
, Issue.5
, pp. 1146-1155
-
-
DeBlois, F.1
Zankowski, C.2
Podgorsak, E.B.3
-
10
-
-
0027175721
-
Measurement of saturation correction factors of thimble-type ionization chambers in pulsed photon beams
-
Derikum K and Roos M 1993 Measurements of saturation correction factors of thimble-type ionization chambers in pulsed photon beams Phys. Med. Biol. 38 75563 (Pubitemid 23188337)
-
(1993)
Physics in Medicine and Biology
, vol.38
, Issue.6
, pp. 755-763
-
-
Derikum, K.1
Roos, M.2
-
11
-
-
0027458353
-
Ion recombination corrections for plane-parallel and thimble chambers in electron and photon radiation
-
Havercroft J M and Klevenhagen S C 1993 Ion recombination corrections for plane-parallel and thimble chambers in electron and photon radiation Phys. Med. Biol. 38 2538 (Pubitemid 23029387)
-
(1993)
Physics in Medicine and Biology
, vol.38
, Issue.1
, pp. 25-38
-
-
Havercroft, J.M.1
Klevenhagen, S.C.2
-
12
-
-
79959344605
-
Commissioning of photon beams of flattening filter free linear accelerator and their accuracy of modelling by anisotropic analytical algorithm
-
10.1016/j.ijrobp.2010.09.050 0360-3016
-
Hrbacek J, Lang S and Klöck S 2011 Commissioning of photon beams of flattening filter free linear accelerator and their accuracy of modelling by anisotropic analytical algorithm Int. J. Radiat. Oncol. Biol. Phys. 80 122837
-
(2011)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.80
, Issue.4
, pp. 1228-1237
-
-
Hrbacek, J.1
Lang, S.2
Klöck, S.3
-
13
-
-
0031034634
-
General collection efficiency for liquid isooctane and tetramethylsilane used as sensitive media in a parallel-plate ionization chamber
-
DOI 10.1088/0031-9155/42/1/009, PII S0031915597725880
-
Johansson B and Wickman G 1997 General collection efficiency for liquid isooctane and tetramethylsilane used as sensitive media in a parallel-plate ionization chamber Phys. Med. Biol. 42 13345 (Pubitemid 27055958)
-
(1997)
Physics in Medicine and Biology
, vol.42
, Issue.1
, pp. 133-145
-
-
Johansson, B.1
Wickman, G.2
-
14
-
-
0030806146
-
General collection efficiency for liquid isooctane and tetramethylsilane in pulsed radiation
-
DOI 10.1088/0031-9155/42/10/006, PII S003191559780276X
-
Johansson B, Wickman G and Bahar-Gogani J 1997 General collection efficiency for liquid isooctane and tetramethylsilane in pulsed radiation Phys. Med. Biol. 42 192938 (Pubitemid 27448993)
-
(1997)
Physics in Medicine and Biology
, vol.42
, Issue.10
, pp. 1929-1938
-
-
Johansson, B.1
Wickman, G.2
Bahar-Gogani, J.3
-
15
-
-
70349315242
-
Dosimetric characteristics of 6 and 10 MV unflattened photon beams
-
0360-3016
-
Kragel G et al 2009 Dosimetric characteristics of 6 and 10 MV unflattened photon beams Int. J. Radiat. Oncol. Biol. Phys. 93 1416
-
(2009)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.93
, pp. 141-146
-
-
Kragel, G.1
-
16
-
-
36749120653
-
Effect of an external electric field on the yield of free ions: Part I. General results from the Onsager theory
-
10.1063/1.1680904 0021-9606
-
Mozumder A 1974 Effect of an external electric field on the yield of free ions: part I. General results from the Onsager theory J. Chem. Phys. 60 43004
-
(1974)
J. Chem. Phys.
, vol.60
, Issue.11
, pp. 4300-4304
-
-
Mozumder, A.1
-
17
-
-
2942517828
-
Free ion yield observed in liquid isooctane irradiated by γ rays. Comparison with the Onsager theory
-
DOI 10.1088/0031-9155/49/10/006, PII S0031915504716802
-
60 gamma rays. Comparison with the Onsager theory Phys. Med. Biol. 49 190514 (Pubitemid 38735483)
-
(2004)
Physics in Medicine and Biology
, vol.49
, Issue.10
, pp. 1905-1914
-
-
Pardo, J.1
Franco, L.2
Gomez, F.3
Iglesias, A.4
Lobato, R.5
Mosquera, J.6
Pazos, A.7
Pena, J.8
Pombar, M.9
Rodriguez, A.10
Sendon, J.11
-
18
-
-
70149094151
-
Determining charge collection efficiency in parallel-plate ionization chambers
-
10.1088/0031-9155/54/12/005 0031-9155
-
Pardo-Montero J and Gomez F 2009 Determining charge collection efficiency in parallel-plate ionization chambers Phys. Med. Biol. 54 367789
-
(2009)
Phys. Med. Biol.
, vol.54
, Issue.12
, pp. 3677-3689
-
-
Pardo-Montero, J.1
Gomez, F.2
-
19
-
-
80052601211
-
Feasibility and early clinical assessment of flattening filter free (FFF) based stereotactic body radiotherapy (SBRT) treatments
-
10.1186/1748-717X-6-113 1748-717X
-
Scorsetti M et al 2011 Feasibility and early clinical assessment of flattening filter free (FFF) based stereotactic body radiotherapy (SBRT) treatments Radiat. Oncol. 12 113
-
(2011)
Radiat. Oncol.
, vol.6
, Issue.1
, pp. 113
-
-
Scorsetti, M.1
-
20
-
-
34249072857
-
Development of a guarded liquid ionization chamber for clinical dosimetry
-
DOI 10.1088/0031-9155/52/11/011, PII S0031915507390180, 011
-
Stewart K J, Elliott A and Seuntjens J P 2007 Development of a guarded liquid ionization chamber for clinical dosimetry Phys. Med. Biol. 52 3089104 (Pubitemid 46795249)
-
(2007)
Physics in Medicine and Biology
, vol.52
, Issue.11
, pp. 3089-3104
-
-
Stewart, K.J.1
Elliott, A.2
Seuntjens, J.P.3
-
21
-
-
78049426900
-
A two-dose-rate method for general recombination correction for liquid ionization chambers in pulsed beams
-
10.1088/0031-9155/55/15/004 0031-9155
-
Tölli H,, Sjögren R and Wendelsten M 2010 A two-dose-rate method for general recombination correction for liquid ionization chambers in pulsed beams Phys. Med. Biol. 55 424760
-
(2010)
Phys. Med. Biol.
, vol.55
, Issue.15
, pp. 4247-4260
-
-
Tölli, H.1
Sjögren, R.2
Wendelsten, M.3
-
22
-
-
33645283656
-
Dosimetric properties of photon beams from a flattening filter free clinical accelerator
-
10.1088/0031-9155/51/7/019 0031-9155
-
Vassiliev O N, Titt U, Ponisch F, Kry S F, Mohan R and Gillin M T 2006 Dosimetric properties of photon beams from a flattening filter free clinical accelerator Phys. Med Biol. 51 190717
-
(2006)
Phys. Med Biol.
, vol.51
, Issue.7
, pp. 1907-1917
-
-
Vassiliev, O.N.1
Titt, U.2
Ponisch, F.3
Kry, S.F.4
Mohan, R.5
Gillin, M.T.6
-
23
-
-
0026782737
-
The use of liquids in ionization chambers for high precision radiotherapy dosimetry
-
10.1088/0031-9155/37/9/005 0031-9155
-
Wickman G and Nyström H 1992 The use of liquids in ionization chambers for high precision radiotherapy dosimetry Phys. Med. Biol. 37 1789812
-
(1992)
Phys. Med. Biol.
, vol.37
, Issue.9
, pp. 1789-1812
-
-
Wickman, G.1
Nyström, H.2
|