메뉴 건너뛰기




Volumn 80, Issue 4, 2011, Pages 1228-1237

Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm

Author keywords

Anisotropic analytical algorithm; Commissioning; Flattening filter free; TrueBeam

Indexed keywords

ANALYTICAL ALGORITHMS; BEAM MODELING; COMMISSIONING; DATA SETS; DEPTH DOSE; EXCHANGE EFFECTS; FIELD SIZE; FLATTENING FILTER FREE; MEAN ENERGY; MEASURED DATA; PHOTON BEAMS; PHYSICAL CONDITIONS; SCATTER FACTOR; SHALLOW DEPTHS; SURFACE DOSE; TRUEBEAM;

EID: 79959344605     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2010.09.050     Document Type: Article
Times cited : (126)

References (24)
  • 1
    • 33744801983 scopus 로고    scopus 로고
    • A flattening filter free photon treatment concept evaluation with Monte Carlo
    • DOI 10.1118/1.2198327
    • U. Titt, O.N. Vassiliev, F. Ponisch, L. Dong, H. Liu, and R. Mohan A flattening filter free photon treatment concept evaluation with Monte Carlo Med Phys 33 2006 1595 1602 (Pubitemid 43830248)
    • (2006) Medical Physics , vol.33 , Issue.6 , pp. 1595-1602
    • Titt, U.1    Vassiliev, O.N.2    Ponisch, F.3    Dong, L.4    Liu, H.5    Mohan, R.6
  • 2
    • 33645281627 scopus 로고    scopus 로고
    • Monte Carlo study of photon fields from a flattening filter free clinical accelerator
    • O.N. Vassiliev, U. Titt, S.F. Kry, F. Ponisch, R. Mohan, and M.T. Gillin Monte Carlo study of photon fields from a flattening filter free clinical accelerator Med Phys 33 2006 820 827
    • (2006) Med Phys , vol.33 , pp. 820-827
    • Vassiliev, O.N.1    Titt, U.2    Kry, S.F.3    Ponisch, F.4    Mohan, R.5    Gillin, M.T.6
  • 3
    • 33645283656 scopus 로고    scopus 로고
    • Dosimetric properties of photon beams from a flattening filter free clinical accelerator
    • O.N. Vassiliev, U. Titt, F. Ponisch, S.F. Kry, R. Mohan, and M.T. Gillin Dosimetric properties of photon beams from a flattening filter free clinical accelerator Phys Med Biol 51 2006 1907 1917
    • (2006) Phys Med Biol , vol.51 , pp. 1907-1917
    • Vassiliev, O.N.1    Titt, U.2    Ponisch, F.3    Kry, S.F.4    Mohan, R.5    Gillin, M.T.6
  • 5
    • 42449146199 scopus 로고    scopus 로고
    • The characterization of unflattened photon beams from a 6 MV linear accelerator
    • DOI 10.1088/0031-9155/53/7/009, PII S0031915508667275
    • J. Cashmore The characterization of unflattened photon beams from a 6 MV linear accelerator Phys Med Biol 53 2008 1933 1946 (Pubitemid 351570900)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.7 , pp. 1933-1946
    • Cashmore, J.1
  • 6
    • 34447253847 scopus 로고    scopus 로고
    • Consequences of removing the flattening filter from linear accelerators in generating high dose rate photon beams for clinical applications: A Monte Carlo study verified by measurement
    • DOI 10.1016/j.nimb.2007.03.020, PII S0168583X07005824
    • E.I. Parsai, D. Pearson, and T. Kvale Consequences of removing the flattening filter from LINACs in generating high dose rate photon beams for clinical applications: A Monte Carlo study verified by measurement Nucl Instrum Methods Phys Res B 2007;Aug 755 759 (Pubitemid 47042941)
    • (2007) Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms , vol.261 , Issue.SPEC. ISS. 1-2 , pp. 755-759
    • Ishmael Parsai, E.1    Pearson, D.2    Kvale, T.3
  • 8
    • 0345733892 scopus 로고    scopus 로고
    • Clinical helical tomotherapy commissioning dosimetry
    • DOI 10.1118/1.1625444
    • J. Balog, G. Olivera, and J. Kapatoes Clinical helical tomotherapy commissioning dosimetry Med Phys 30 2003 3097 3106 (Pubitemid 37553750)
    • (2003) Medical Physics , vol.30 , Issue.12 , pp. 3097-3106
    • Balog, J.1    Olivera, G.2    Kapatoes, J.3
  • 9
    • 22844450224 scopus 로고    scopus 로고
    • A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations
    • DOI 10.1088/0031-9155/50/8/010
    • W. Ulmer, J. Pyyry, and W.A. Kaissl 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations Phys Med Biol 50 8 2005 1767 1790 (Pubitemid 41223648)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.8 , pp. 1767-1790
    • Ulmer, W.1    Pyyry, J.2    Kaissl, W.3
  • 11
    • 33644694219 scopus 로고    scopus 로고
    • Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: Fundamental characterization in water
    • DOI 10.1088/0031-9155/51/6/004, PII S0031915506060829
    • A. Fogliata, G. Nicolini, E. Vanetti, A. Clivio, and L. Cozzi Dosimetric evaluation of anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water Phys Med Biol 51 6 2006 1421 1438 (Pubitemid 43332345)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.6 , pp. 1421-1438
    • Fogliata, A.1    Nicolini, G.2    Vanetti, E.3    Clivio, A.4    Cozzi, L.5
  • 13
    • 33845220491 scopus 로고    scopus 로고
    • Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning
    • DOI 10.1016/j.radonc.2006.10.020, PII S0167814006005664
    • C.M. Bragg, and J. Conway Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning Radiother Oncol 81 3 2006 315 323 (Pubitemid 44856009)
    • (2006) Radiotherapy and Oncology , vol.81 , Issue.3 , pp. 315-323
    • Bragg, C.M.1    Conway, J.2
  • 14
    • 34249941855 scopus 로고    scopus 로고
    • Experimental validation of the Eclipse AAA algorithm
    • K. Breitman, S. Rathee, and C. Newcomb Experimental validation of the Eclipse AAA algorithm J Appl Clin Med Phys 8 2 2007 76 92
    • (2007) J Appl Clin Med Phys , vol.8 , Issue.2 , pp. 76-92
    • Breitman, K.1    Rathee, S.2    Newcomb, C.3
  • 15
  • 17
    • 33645009141 scopus 로고    scopus 로고
    • Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams
    • I. Griessbach, M. Lapp, J. Bohsung, G. Gademann, and D. Harder Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams Med Phys 32 2005 3750 3754
    • (2005) Med Phys , vol.32 , pp. 3750-3754
    • Griessbach, I.1    Lapp, M.2    Bohsung, J.3    Gademann, G.4    Harder, D.5
  • 18
    • 33744811445 scopus 로고    scopus 로고
    • Properties of unflattened photon beams shaped by a multileaf collimator
    • DOI 10.1118/1.2201149
    • F. Pönisch, U. Titt, O.N. Vassiliev, S.F. Kry, and R. Mohan Properties of unflattened photon beams shaped by a multileaf collimator Med Phys 33 2006 1738 1746 (Pubitemid 43830262)
    • (2006) Medical Physics , vol.33 , Issue.6 , pp. 1738-1746
    • Ponisch, F.1    Titt, U.2    Vassiliev, O.N.3    Kry, S.F.4    Mohan, R.5
  • 19
    • 34547401488 scopus 로고    scopus 로고
    • Strahlenphysikalische Einflussgrößen bei der Dosimetrie mit verschiedenen Detektortypen
    • DOI 10.1016/j.zemedi.2007.03.001, PII S0939388907000360
    • M. Schwedas, M. Scheithauer, T. Wiezorek, and T.G. Wendt Strahlenphysikalische Einflussgrössen bei der Dosimetrie mit verschiedenen Detektortypen Z Med Phys 17 3 2007 172 179 (Pubitemid 47176401)
    • (2007) Zeitschrift fur Medizinische Physik , vol.17 , Issue.3 , pp. 172-179
    • Schwedas, M.1    Scheithauer, M.2    Wiezorek, T.3    Wendt, T.G.4
  • 20
    • 0036804332 scopus 로고    scopus 로고
    • Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: Experience from five radiotherapy departments
    • DOI 10.1016/S0167-8140(02)00174-3, PII S0167814002001743
    • A. Van Esch, J. Bohsung, and P. Sorvari Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: experience from five radiotherapy departments Radiother Oncol 65 1 2002 53 70 (Pubitemid 35284466)
    • (2002) Radiotherapy and Oncology , vol.65 , Issue.1 , pp. 53-70
    • Van Esch, A.1    Bohsung, J.2    Sorvari, P.3    Tenhunen, M.4    Paiusco, M.5    Iori, M.6    Engstrom, P.7    Nystrom, H.8    Huyskens, D.P.9
  • 21
    • 52949111474 scopus 로고    scopus 로고
    • Dosimetric characteristics of Novalis Tx system with high definition multileaf collimator
    • Z. Chang, Z. Wang, and Q.J. Wu Dosimetric characteristics of Novalis Tx system with high definition multileaf collimator Med Phys 35 2008 4460 4463
    • (2008) Med Phys , vol.35 , pp. 4460-4463
    • Chang, Z.1    Wang, Z.2    Wu, Q.J.3
  • 22
    • 34347384633 scopus 로고    scopus 로고
    • Quantitative evaluation of a beam-matching procedure using one-dimensional gamma analysis
    • DOI 10.1118/1.2745239
    • J. Hrbacek, T. Depuydt, A. Nulens, A. Swinnen, and F. Van Den Heuvel Quantitative evaluation of a beam-matching procedure using one-dimensional gamma analysis Med Phys 34 2007 2917 2927 (Pubitemid 47019813)
    • (2007) Medical Physics , vol.34 , Issue.7 , pp. 2917-2927
    • Hrbacek, J.1    Depuydt, T.2    Nulens, A.3    Swinnen, A.4    Van Den Heuvel, F.5
  • 23
    • 73649083321 scopus 로고    scopus 로고
    • Photon beam quality variations of a flattening filter free linear accelerator
    • D. Georg, G. Kragl, S. Wetterstedt, P. McCavana, B. McClean, and T. Knoos Photon beam quality variations of a flattening filter free linear accelerator Med Phys 37 2010 49 53
    • (2010) Med Phys , vol.37 , pp. 49-53
    • Georg, D.1    Kragl, G.2    Wetterstedt, S.3    McCavana, P.4    McClean, B.5    Knoos, T.6
  • 24
    • 77950559016 scopus 로고    scopus 로고
    • Out-of-field photon dose following removal of the flattening filter from a medical accelerator
    • S.F. Kry, O.N. Vassiliev, and R. Mohan Out-of-field photon dose following removal of the flattening filter from a medical accelerator Phys Med Biol 55 2010 2155 2166
    • (2010) Phys Med Biol , vol.55 , pp. 2155-2166
    • Kry, S.F.1    Vassiliev, O.N.2    Mohan, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.