-
1
-
-
0019845162
-
Use of a Victoreen 500 electrometer to determine ionization chamber collection efficiencies
-
Almond P R 1981 Use of a Victoreen 500 electrometer to determine ionization chamber collection efficiencies Med. Phys. 8 901-4
-
(1981)
Med. Phys.
, vol.8
, Issue.6
, pp. 901-904
-
-
Almond, P.R.1
-
2
-
-
0001400494
-
Ionization measurements at very high intensities: 1. Pulsed radiation beams
-
Boag J W 1950 Ionization measurements at very high intensities: 1. Pulsed radiation beams Br. J. Radiol. 23 601-11
-
(1950)
Br. J. Radiol.
, vol.23
, Issue.274
, pp. 601-611
-
-
Boag, J.W.1
-
3
-
-
0018832381
-
Current collection and ionic recombination in small cylindrical ionization chambers exposed to pulsed radiation
-
Boag J W and Currant J 1980 Current collection and ionic recombination in small cylindrical ionization chambers exposed to pulsed radiation Br. J. Appl. Phys. 53 471-8
-
(1980)
Br. J. Appl. Phys.
, vol.53
, pp. 471-478
-
-
Boag, J.W.1
Currant, J.2
-
4
-
-
0001423824
-
The saturation curve at high ionization intensity
-
Boag J W and Wilson T 1952 The saturation curve at high ionization intensity Br. J. Appl. Phys. 3 222-9
-
(1952)
Br. J. Appl. Phys.
, vol.3
, Issue.7
, pp. 222-229
-
-
Boag, J.W.1
Wilson, T.2
-
5
-
-
2642710922
-
Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams
-
Dau A, Löfroth P O and Wickman G 1998 Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams Phys. Med. Biol. 43 21-36
-
(1998)
Phys. Med. Biol.
, vol.43
, Issue.1
, pp. 21-36
-
-
Dau, A.1
Löfroth, P.O.2
Wickman, G.3
-
6
-
-
0242606138
-
First tests of a liquid ionization chamber to monitor intensity modulated radiation beams
-
Eberle K, Engler J, Hartmann G, Hofmann R and Hörandel J R 2003 First tests of a liquid ionization chamber to monitor intensity modulated radiation beams Phys. Med. Biol. 48 3555-64
-
(2003)
Phys. Med. Biol.
, vol.48
, Issue.21
, pp. 3555-3564
-
-
Eberle, K.1
Engler, J.2
Hartmann, G.3
Hofmann, R.4
Hörandel, J.R.5
-
7
-
-
1842329396
-
Saturation characteristics of parallel-plate ionization chambers
-
Greening J R 1964 Saturation characteristics of parallel-plate ionization chambers Phys. Med. Biol. 9 143-54
-
(1964)
Phys. Med. Biol.
, vol.9
, Issue.2
, pp. 143-154
-
-
Greening, J.R.1
-
8
-
-
0031034634
-
General collection efficiency for liquid isooctane and tetramethylsilane used as sensitive media in a parallel-plate ionization chamber
-
Johansson B and Wickman G 1997 General collection efficiency for liquid isooctane and tetramethylsilane used as sensitive media in a parallel-plate ionization chamber Phys. Med. Biol. 42 133-45
-
(1997)
Phys. Med. Biol.
, vol.42
, Issue.1
, pp. 133-145
-
-
Johansson, B.1
Wickman, G.2
-
9
-
-
0030806146
-
General collection efficiency for liquid isooctane and tetramethylsilane in pulsed radiation
-
Johansson B, Wickman G and Bahar-Gogani J 1997 General collection efficiency for liquid isooctane and tetramethylsilane in pulsed radiation Phys. Med. Biol. 42 1929-38
-
(1997)
Phys. Med. Biol.
, vol.42
, Issue.10
, pp. 1929-1938
-
-
Johansson, B.1
Wickman, G.2
Bahar-Gogani, J.3
-
10
-
-
0031767218
-
Initial recombination in a parallel-plate ionization chamber exposed to heavy ions
-
Kanai T, Sudo M, Matsufuji N and Futami Y 1998 Initial recombination in a parallel-plate ionization chamber exposed to heavy ions Phys. Med. Biol. 43 3549-58
-
(1998)
Phys. Med. Biol.
, vol.43
, Issue.12
, pp. 3549-3558
-
-
Kanai, T.1
Sudo, M.2
Matsufuji, N.3
Futami, Y.4
-
11
-
-
0344143688
-
Mesure de la valence des ions dans les gaz
-
Langevin P 1913 Mesure de la valence des ions dans les gaz Le Radium 10 113-24
-
(1913)
Le Radium
, vol.10
, Issue.4
, pp. 113-124
-
-
Langevin, P.1
-
12
-
-
70350690192
-
Der elektrische strom in ionisierter luft in einem ebenen kondensator
-
Mie G 1904 Der elektrische strom in ionisierter luft in einem ebenen kondensator Ann. Phys., Lpz. 46 1131-47
-
(1904)
Ann. Phys., Lpz.
, vol.46
, pp. 1131-1147
-
-
Mie, G.1
-
13
-
-
36749120653
-
Effect of an external electric field on the yield of free ions: I. General results from the Onsager theory
-
Mozumder A 1974 Effect of an external electric field on the yield of free ions: I. General results from the Onsager theory J. Chem. Phys. 60 4300-4
-
(1974)
J. Chem. Phys.
, vol.60
, Issue.11
, pp. 4300-4304
-
-
Mozumder, A.1
-
14
-
-
36149016302
-
Initial recombination of ions
-
Onsager L 1938 Initial recombination of ions Phys. Rev. 54 554-7
-
(1938)
Phys. Rev.
, vol.54
, Issue.8
, pp. 554-557
-
-
Onsager, L.1
-
16
-
-
2942517828
-
60 gamma rays. Comparison with the Onsager theory
-
60 gamma rays. Comparison with the Onsager theory Phys. Med. Biol. 49 1905-14
-
(2004)
Phys. Med. Biol.
, vol.49
, Issue.10
, pp. 1905-1914
-
-
Pardo, J.1
-
17
-
-
22844434471
-
Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance
-
Pardo J, Franco L, Gómez F, Iglesias A, Pazos A, Pena J, Lobato R, Mosquera J, Pombar M and Sendón J 2005 Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance Phys. Med. Biol. 50 1703-16
-
(2005)
Phys. Med. Biol.
, vol.50
, Issue.8
, pp. 1703-1716
-
-
Pardo, J.1
Franco, L.2
Gómez, F.3
Iglesias, A.4
Pazos, A.5
Pena, J.6
Lobato, R.7
Mosquera, J.8
Pombar, M.9
Sendón, J.10
-
18
-
-
34249072857
-
Development of a guarded liquid ionization chamber for clinical dosimetry
-
Stewart K J, Elliott A and Seunjens J P 2007 Development of a guarded liquid ionization chamber for clinical dosimetry Phys. Med. Biol. 52 3089-104
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.11
, pp. 3089-3104
-
-
Stewart, K.J.1
Elliott, A.2
Seunjens, J.P.3
-
19
-
-
0031859143
-
Liquid ionization chambers for absorbed dose measurements in water at low dose rates and intermediate photon energies
-
Wickman G, Johansson B, Bahar-Gogani J, Holmström T and Grindborg J E 1998 Liquid ionization chambers for absorbed dose measurements in water at low dose rates and intermediate photon energies Med. Phys. 25 900-7
-
(1998)
Med. Phys.
, vol.25
, Issue.6
, pp. 900-907
-
-
Wickman, G.1
Johansson, B.2
Bahar-Gogani, J.3
Holmström, T.4
Grindborg, J.E.5
-
20
-
-
0026782737
-
The use of liquids in ionization chambers for high precision radiotherapy dosimetry
-
Wickman G and Nyström H 1992 The use of liquids in ionization chambers for high precision radiotherapy dosimetry Phys. Med. Biol. 37 1789-812
-
(1992)
Phys. Med. Biol.
, vol.37
, Issue.9
, pp. 1789-1812
-
-
Wickman, G.1
Nyström, H.2
-
21
-
-
0031859012
-
Determination of saturation charge and collection efficiency for ionization chambers in continuous beams
-
Zankowski C and Podgorsak E B 1998 Determination of saturation charge and collection efficiency for ionization chambers in continuous beams Med. Phys. 25 908-15
-
(1998)
Med. Phys.
, vol.25
, Issue.6
, pp. 908-915
-
-
Zankowski, C.1
Podgorsak, E.B.2
|