메뉴 건너뛰기




Volumn 15, Issue 1, 2012, Pages 9-21

Possibilities and limitations of implant placement by virtual planning data and surgical guide templates;Implantatinsertion mittels 3-D-führungsschablonen: Möglichkeiten und grenzen

Author keywords

Computer assisted; Dental implantation; Image processing; Three dimensional; Treatment planning

Indexed keywords

ARTICLE; AUDIOVISUAL EQUIPMENT; COMPUTER ASSISTED SURGERY; COMPUTER INTERFACE; HUMAN; IMAGE PROCESSING; METHODOLOGY; MINIMALLY INVASIVE SURGERY; PATIENT CARE PLANNING; THREE DIMENSIONAL IMAGING; TOOTH IMPLANTATION;

EID: 84860130319     PISSN: 14634201     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (41)

References (41)
  • 1
    • 0033742261 scopus 로고    scopus 로고
    • Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography
    • Besimo CE, Lambrecht JT, Guindy JS. Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography. Dentomaxillofac Radiol 2000;29: 46-51.
    • (2000) Dentomaxillofac Radiol , vol.29 , pp. 46-51
    • Besimo, C.E.1    Lambrecht, J.T.2    Guindy, J.S.3
  • 3
    • 26944469120 scopus 로고    scopus 로고
    • In vitro accuracy of a novel registration and targeting technique for image-guided template production
    • DOI 10.1111/j.1600-0501.2005.01131.x
    • Widmann G, Widmann R, Widmann E, Jaschke W, Bale RJ. In vitro accuracy of a novel registration and targeting technique for image guided template production. Clin Oral Implants Res 2005;16:502-508. (Pubitemid 43961032)
    • (2005) Clinical Oral Implants Research , vol.16 , Issue.4 , pp. 502-508
    • Widmann, G.1    Widmann, R.2    Widmann, E.3    Jaschke, W.4    Bale, R.J.5
  • 5
    • 49149088692 scopus 로고    scopus 로고
    • Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: Clinical data from 94 implants
    • Ersoy AE, Turkyilmaz I, Ozan O, McGlumphy EA. Reliability of implant Placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants. J Periodontol 2008;79:1339-1345.
    • (2008) J Periodontol , vol.79 , pp. 1339-1345
    • Ersoy, A.E.1    Turkyilmaz, I.2    Ozan, O.3    McGlumphy, E.A.4
  • 7
    • 44949184646 scopus 로고    scopus 로고
    • Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: Optical tracking vs. stereolithographic splint systems
    • Ruppin J, Popovic A, Strauss M, Spuntrup E, Steiner A, Stoll C. Evaluation of the accuracy of three different computer-aided surgery Systems in dental implantology: optical tracking vs. stereolithographic splint systems. Clin Oral Implants Res 2008;19:709-716.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 709-716
    • Ruppin, J.1    Popovic, A.2    Strauss, M.3    Spuntrup, E.4    Steiner, A.5    Stoll, C.6
  • 8
    • 19044400459 scopus 로고    scopus 로고
    • Clinical application of stereolithographic surgical guides for implant placement: Preliminary results
    • DOI 10.1902/jop.2005.76.4.503
    • Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol 2005;76:503-507. (Pubitemid 40711275)
    • (2005) Journal of Periodontology , vol.76 , Issue.4 , pp. 503-507
    • Di Giacomo, G.A.P.1    Cury, P.R.2    De Araujo, N.S.3    Sendyk, W.R.4    Sendyk, C.L.5
  • 9
    • 33847284114 scopus 로고    scopus 로고
    • Precision for Computer-Guided Implant Placement: Using 3D Planning Software and Fixed Intraoral Reference Points
    • DOI 10.1016/j.joms.2006.10.050, PII S0278239106019744
    • Holst S, Blatz MB, Eitner S. Precision for computer-guided implant placement: using 3D planning software and fixed intraoral reference points. J Oral Maxillofac Surg 2007;65: 393-399. (Pubitemid 46329247)
    • (2007) Journal of Oral and Maxillofacial Surgery , vol.65 , Issue.3 , pp. 393-399
    • Holst, S.1    Blatz, M.B.2    Eitner, S.3
  • 10
    • 26944471740 scopus 로고    scopus 로고
    • The accuracy of two commercially available systems for image-guided dental implant insertion based on infrared tracking cameras was compared with manual implantation
    • Brief J, Edinger D, Hassfeld S, Eggers G. The accuracy of two commercially available systems for image-guided dental implant insertion based on infrared tracking cameras was compared with manual implantation. Clin Oral Implants Res 2005;16:495-501.
    • (2005) Clin Oral Implants Res , vol.16 , pp. 495-501
    • Brief, J.1    Edinger, D.2    Hassfeld, S.3    Eggers, G.4
  • 11
    • 0348048836 scopus 로고    scopus 로고
    • Reliability of Preoperative Planning of an Image-Guided System for Oral Implant Placement Based on 3-dimensional Images: An in Vivo Study
    • Fortin T, Bosson JL, Coudert JL, Isidori, M. Reliability of preoperative planning of an imaged-guided system for oral implant placement based on 3-dimensional images: an in vivo study. Int J Oral Maxillofac Implants 2003;18:886-893. (Pubitemid 38032652)
    • (2003) International Journal of Oral and Maxillofacial Implants , vol.18 , Issue.6 , pp. 886-893
    • Fortin, T.1    Bosson, J.L.2    Coudert, J.L.3    Isidori, M.4
  • 12
    • 43449089485 scopus 로고    scopus 로고
    • Accuracy of Miniscrew Implant Placement With a 3-Dimensional Surgical Guide
    • DOI 10.1016/j.joms.2007.08.047, PII S0278239107020964
    • Suzuki EY, Suzuki B. Accuracy of miniscrew implant placement with a 3-dimensional surgical guide. J Oral Maxillofac Surg 2008;66:1245-1252. (Pubitemid 351671939)
    • (2008) Journal of Oral and Maxillofacial Surgery , vol.66 , Issue.6 , pp. 1245-1252
    • Suzuki, E.Y.1    Suzuki, B.2
  • 13
    • 33645963125 scopus 로고    scopus 로고
    • Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part II. A clinical report
    • DOI 10.1111/j.1532-849X.2006.00084.x
    • Lal K, White GS, Morea DN, Wright RF. Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part II. A clinical report. J Prosthodont 2006;15:117-122. (Pubitemid 43597978)
    • (2006) Journal of Prosthodontics , vol.15 , Issue.2 , pp. 117-122
    • Lal, K.1    White, G.S.2    Morea, D.N.3    Wright, R.F.4
  • 14
    • 68949112062 scopus 로고    scopus 로고
    • Prosthetically driven, computer-guided implant planning for the edentulous maxilla: A model study
    • Katsoulis J, Pazera P, Mericske-Stem R. Prosthetically driven, computer-guided implant planning for the edentulous maxilla: a model study. Clin Implant Dent Relat Res 2009;11: 238-245.
    • (2009) Clin Implant Dent Relat Res , vol.11 , pp. 238-245
    • Katsoulis, J.1    Pazera, P.2    Mericske-Stem, R.3
  • 15
    • 84860191136 scopus 로고    scopus 로고
    • An alternative method to match planned and achieved positions of implants, after virtual planning using cone beam CT data and surgical guide templates - A method reducing patient radiation exposure (part I)
    • Nickenig HJ, Eitner S. An alternative method to match planned and achieved positions of implants, after virtual planning using cone beam CT data and surgical guide templates - A method reducing patient radiation exposure (part I). J Craniomaxillofac Surg 2010;21:1386-1393.
    • (2010) J Craniomaxillofac Surg , vol.21 , pp. 1386-1393
    • Nickenig, H.J.1    Eitner, S.2
  • 16
    • 77956655716 scopus 로고    scopus 로고
    • Evaluation of the difference in accuracy between implant placement by virtual planning data and surgical guide templates versus the conventional free-hand method - A combined in vivo - In vitro technique using cone-beam CT data (Part II)
    • Nickenig HJ, Wichmann M, Hamel J, Schlegel KA, Eitner S. Evaluation of the difference in accuracy between implant placement by virtual planning data and surgical guide templates versus the conventional free-hand method - a combined in vivo - in vitro technique using cone-beam CT data (Part II). J Craniomaxillofac Surg 2010;38:488-493.
    • (2010) J Craniomaxillofac Surg , vol.38 , pp. 488-493
    • Nickenig, H.J.1    Wichmann, M.2    Hamel, J.3    Schlegel, K.A.4    Eitner, S.5
  • 17
    • 84860116980 scopus 로고    scopus 로고
    • CT-based surgical templates vs. traditional surgical guides
    • Nickenig HJ, Spiekermann H. CT-based surgical templates vs. traditional surgical guides. J Dent Implant 2006;22:272-280.
    • (2006) J Dent Implant , vol.22 , pp. 272-280
    • Nickenig, H.J.1    Spiekermann, H.2
  • 20
    • 3042517245 scopus 로고    scopus 로고
    • Hemorrhaging associated with endosseous implant placement in the anterior mandible: A review of the literature
    • Kalpidis CD, Setayesh RM. Hemorrhaging associated with endosseous implant placement in the anterior mandible: a review of the literature. J Periodontol 2004;75:631-645. (Pubitemid 38811852)
    • (2004) Journal of Periodontology , vol.75 , Issue.5 , pp. 631-645
    • Kalpidis, C.D.R.1    Setayesh, R.M.2
  • 21
    • 0036516691 scopus 로고    scopus 로고
    • Flapless implant surgery: A 10-year clinical retrospective analysis
    • Campelo LD, Camara JR. Flapless implant surgery: a 10-year clinical retrospective analysis. Int J Oral Maxillofac Implants 2002;17:271-276.
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 271-276
    • Campelo, L.D.1    Camara, J.R.2
  • 23
    • 77954712978 scopus 로고    scopus 로고
    • Mandible size and morphology determined with CT on a premise of dental implant operation
    • Watanabe H, Mohammad AM, Kurabayashi T, Aoki H. Mandible size and morphology determined with CT on a premise of dental implant operation. Surg Radiol Anat 2010;32:343-349.
    • (2010) Surg Radiol Anat , vol.32 , pp. 343-349
    • Watanabe, H.1    Mohammad, A.M.2    Kurabayashi, T.3    Aoki, H.4
  • 24
    • 79251612139 scopus 로고    scopus 로고
    • Risk assessment of lingual plate perforation in posterior mandibular region: A virtual implant placement study using cone beam computed tomography
    • Chan HL, Benavides E, Yeh CY, Fu JH, Rudek IE, Wang HL. Risk assessment of lingual plate perforation in posterior mandibular region: a virtual implant placement study using cone beam computed tomography. J Periodontol 2011;82:129-135.
    • (2011) J Periodontol , vol.82 , pp. 129-135
    • Chan, H.L.1    Benavides, E.2    Yeh, C.Y.3    Fu, J.H.4    Rudek, I.E.5    Wang, H.L.6
  • 25
    • 40849136266 scopus 로고    scopus 로고
    • Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading
    • Lin CL, Wang JC, Ramp LC, Liu PR. Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading. Int J Oral Maxillofac Implants 2008;23:57-64.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 57-64
    • Lin, C.L.1    Wang, J.C.2    Ramp, L.C.3    Liu, P.R.4
  • 26
    • 29244488214 scopus 로고    scopus 로고
    • Success or failure of dental implants? A literature review with treatment considerations
    • Porter JA, von Fraunhofer JA. Success or failure of dental implants? A literature review with treatment considerations. Gen Dent 2005;53:423-432. (Pubitemid 41830602)
    • (2005) General Dentistry , vol.53 , Issue.6 , pp. 423-432
    • Porter, J.A.1    Von Fraunhofer, J.A.2
  • 27
    • 0028537747 scopus 로고
    • Implant-protected occlusion: A biomechanical rationale
    • Misch CE, Bidez MW. Implant-protected occlusion: A biomechanical rationale. Compendium 1994;15:1330-1334.
    • (1994) Compendium , vol.15 , pp. 1330-1334
    • Misch, C.E.1    Bidez, M.W.2
  • 28
    • 34548625475 scopus 로고    scopus 로고
    • Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates
    • DOI 10.1016/j.jcms.2007.02.004, PII S1010518207000261
    • Nickenig HJ, Eitner S. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates. J Craniomaxillofac Surg 2007;35:207-211. (Pubitemid 47400214)
    • (2007) Journal of Cranio-Maxillofacial Surgery , vol.35 , Issue.4-5 , pp. 207-211
    • Nickenig, H.-J.1    Eitner, S.2
  • 30
    • 33847690592 scopus 로고    scopus 로고
    • Patient-centred outcomes comparing transmucosal implant placement with an open approach in the maxilla: A prospective, non-randomized pilot study
    • Nkenke E, Eitner S, Radespiel-Tröger M, Vairaktaries E, Neukam FW, Fenner M. Patient-centred outcomes comparing transmucosal implant placement with an open approach in the maxilla: a prospective, non-randomized pilot study. Clin Oral Implants Res 2007;18:197-203.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 197-203
    • Nkenke, E.1    Eitner, S.2    Radespiel-Tröger, M.3    Vairaktaries, E.4    Neukam, F.W.5    Fenner, M.6
  • 31
    • 41949113148 scopus 로고    scopus 로고
    • Flapless implant surgery: Review of the literature and report of 2 cases with computer-guided surgical approach
    • DOI 10.1016/j.joms.2007.12.010, PII S0278239107021465
    • Azari A, Nikzad S. Flapless implant surgery: review of the literature and report of 2 cases with computer-guided surgical approach. J Oral Maxillofac Surg 2008;66:1015-1021. (Pubitemid 351514832)
    • (2008) Journal of Oral and Maxillofacial Surgery , vol.66 , Issue.5 , pp. 1015-1021
    • Azari, A.1    Nikzad, S.2
  • 33
    • 34250675244 scopus 로고    scopus 로고
    • Guidelines for flapless surgery
    • DOI 10.1016/j.joms.2007.03.017, PII S0278239107003461
    • Sclar AG. Guidelines for flapless surgery. J Oral Maxillofac Surg 2007;65:20-32. (Pubitemid 46936050)
    • (2007) Journal of Oral and Maxillofacial Surgery , vol.65 , Issue.7 SUPPL. , pp. 20-32
    • Sclar, A.G.1
  • 34
    • 33745972063 scopus 로고    scopus 로고
    • Effect of flapless implant surgery on soft tissue profile: A randomized controlled clinical trial
    • DOI 10.1902/jop.2006.050169
    • Oh TJ, Shotwell JL, Billy EJ, Wang HL. Effect of implant surgery on soft tissue profile: a randomized controlled clinical trial. J Periodontol 2006;77:874-882. (Pubitemid 44740644)
    • (2006) Journal of Periodontology , vol.77 , Issue.5 , pp. 874-882
    • Oh, T.-J.1    Shotwell, J.L.2    Billy, E.J.3    Wang, H.-L.4
  • 35
    • 78349282702 scopus 로고    scopus 로고
    • Radiographic evaluation of marginal bone levels during healing period, adjacent to parallel-screw cylinder implants inserted in the posterior zone of the jaws, placed with flapless surgery
    • Nickenig HJ, Wichmann M, Schlegel KA, Eitner S. Radiographic evaluation of marginal bone levels during healing period, adjacent to parallel-screw cylinder implants inserted in the posterior zone of the jaws, placed with flapless surgery. Clin Oral Implants Res 2010;2:1386-1393.
    • (2010) Clin Oral Implants Res , vol.2 , pp. 1386-1393
    • Nickenig, H.J.1    Wichmann, M.2    Schlegel, K.A.3    Eitner, S.4
  • 37
    • 0036369103 scopus 로고    scopus 로고
    • Teledentistry using videoconferencing and a DICOM image management system
    • Chen RS, Chen SK. Teledentistry using videoconferencing and a DICOM image management system. J Telemed Telecare 2002;8:244-246.
    • (2002) J Telemed Telecare , vol.8 , pp. 244-246
    • Chen, R.S.1    Chen, S.K.2
  • 38
    • 34249855767 scopus 로고    scopus 로고
    • Teledentistry: Seeing a doctor from a distance
    • Chen H, Fricton J. Teledentistry: seeing a doctor from a distance. Northwest Dent 2007;86:27-28.
    • (2007) Northwest Dent , vol.86 , pp. 27-28
    • Chen, H.1    Fricton, J.2
  • 39
    • 49249132130 scopus 로고    scopus 로고
    • Use of telemedicine for pre-implant dental assessment - A comparative study
    • Nickenig HJ, Wichmann M, Schlegel KA, Eitner S. Use of telemedicine for pre-implant dental assessment- a comparative study. J Telemed Telecare 2008;14:93-97.
    • (2008) J Telemed Telecare , vol.14 , pp. 93-97
    • Nickenig, H.J.1    Wichmann, M.2    Schlegel, K.A.3    Eitner, S.4
  • 40
    • 71549160805 scopus 로고    scopus 로고
    • Effect of surgical drill guide on heat generated from implant drilling
    • Misir AF, Sumer M, Yenisey M, Ergioglu E. Effect of surgical drill guide on heat generated from implant drilling. J Oral Maxillofac Surg 2009;67:2663-2668.
    • (2009) J Oral Maxillofac Surg , vol.67 , pp. 2663-2668
    • Misir, A.F.1    Sumer, M.2    Yenisey, M.3    Ergioglu, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.