Volumn 77, Issue 5, 2006, Pages 874-882

Effect of flapless implant surgery on soft tissue profile: A randomized controlled clinical trial

Author keywords

Dental implant; Immediate loading; Preservation; Single tooth implant; Surgery

Indexed keywords

ADULT; AGED; ARTICLE; BLEEDING; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EQUIPMENT DESIGN; ESTHETIC SURGERY; FEMALE; HUMAN; INTERMETHOD COMPARISON; KERATINIZATION; MALE; MUCOSA; PERIODONTAL EXAMINATION; POSTOPERATIVE PERIOD; RANDOMIZED CONTROLLED TRIAL; SAMPLE SIZE; SOFT TISSUE; STATISTICAL SIGNIFICANCE; SURGICAL TECHNIQUE; TISSUE REPAIR; TOOTH IMPLANTATION; ANALYSIS OF VARIANCE; GINGIVA; HISTOLOGY; METHODOLOGY; MIDDLE AGED; NONPARAMETRIC TEST; SURVIVAL; TIME;

EID: 33745972063     PISSN: 00223492     EISSN: None     Source Type: Journal    
DOI: 10.1902/jop.2006.050169     Document Type: Article
Times cited : (108)

References (51)
  • 1
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw: Experience from a 10-year period
    • Brånemark PI, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw: Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl 1977;16:1-132.
    • (1977) Scand J Plast Reconstr Surg Suppl , vol.16 , pp. 1-132
    • Brånemark, P.I.1    Hansson, B.O.2    Adell, R.3
  • 2
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.I.4
  • 4
    • 0033193655 scopus 로고    scopus 로고
    • Survival of the Brånemark implant in partially edentulous jaws: A 10-year prospective multicenter study
    • Lekholm U, Gunne J, Henry P, et al. Survival of the Brånemark implant in partially edentulous jaws: A 10-year prospective multicenter study. Int J Oral Maxillofac Implants 1999;14:639-645.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 639-645
    • Lekholm, U.1    Gunne, J.2    Henry, P.3
  • 5
    • 0024618778 scopus 로고
    • A retrospective multicenter evaluation of the survival rate of osseointegrated fixtures supporting fixed partial prostheses in the treatment of partial edentulism
    • van Steenberghe D. A retrospective multicenter evaluation of the survival rate of osseointegrated fixtures supporting fixed partial prostheses in the treatment of partial edentulism. J Prosthet Dent 1989; 61:217-223.
    • (1989) J Prosthet Dent , vol.61 , pp. 217-223
    • van Steenberghe, D.1
  • 6
    • 0034576685 scopus 로고    scopus 로고
    • Osseointegrated implant for single-tooth replacement: A retrospective multicenter study on routine use in private practice
    • Bianco G, Di Raimondo R, Luongo G, et al. Osseointegrated implant for single-tooth replacement: A retrospective multicenter study on routine use in private practice. Clin Implant Dent Relat Res 2000; 2:152-158.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 152-158
    • Bianco, G.1    Di Raimondo, R.2    Luongo, G.3
  • 7
    • 0034172846 scopus 로고    scopus 로고
    • A 5-year prospective study of Astra single tooth implants
    • Palmer RM, Palmer PJ, Smith BJ. A 5-year prospective study of Astra single tooth implants. Clin Oral Implants Res 2000;11:179-182.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 179-182
    • Palmer, R.M.1    Palmer, P.J.2    Smith, B.J.3
  • 9
    • 0036549009 scopus 로고    scopus 로고
    • Long-term clinical effectiveness of oral implants in the treatment of partial edentulism
    • Romeo E, Chiapasco M, Ghisofli M, Vogel G. Long-term clinical effectiveness of oral implants in the treatment of partial edentulism. Clin Oral Implants Res 2002; 13:133-143.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 133-143
    • Romeo, E.1    Chiapasco, M.2    Ghisofli, M.3    Vogel, G.4
  • 10
    • 0019435541 scopus 로고
    • Osseointegrated titanium implants: Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man
    • Albrektsson T, Brånemark PI, Hansson HA, Lindstrom J. Osseointegrated titanium implants: Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand 1981;52:155-170.
    • (1981) Acta Orthop Scand , vol.52 , pp. 155-170
    • Albrektsson, T.1    Brånemark, P.I.2    Hansson, H.A.3    Lindstrom, J.4
  • 11
    • 0031152016 scopus 로고    scopus 로고
    • Long term evaluation of non-submerged ITI implants. Part I: 8-year life table analysis of a prospective multi-center study with 2359 implants
    • Buser D, Mericske-Stern R, Bernard JP, et al. Long term evaluation of non-submerged ITI implants. Part I: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997;8:161-172.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 161-172
    • Buser, D.1    Mericske-Stern, R.2    Bernard, J.P.3
  • 12
    • 0033140229 scopus 로고    scopus 로고
    • Clinical experience with one-stage, non-submerged dental implants
    • Buser D, Mericske-Stern R, Dula K, Lang NP. Clinical experience with one-stage, non-submerged dental implants. Adv Dent Res 1999;13:153-161.
    • (1999) Adv Dent Res , vol.13 , pp. 153-161
    • Buser, D.1    Mericske-Stern, R.2    Dula, K.3    Lang, N.P.4
  • 13
    • 0025622922 scopus 로고
    • Tissue integration of non-submerged implants: One-year results of a prospective study with 100 ITI hollow-screw and hollow-cylinder implants
    • Buser D, Weber HP, Lang NP. Tissue integration of non-submerged implants: One-year results of a prospective study with 100 ITI hollow-screw and hollow-cylinder implants. Clin Oral Implants Res 1990;1:33-40.
    • (1990) Clin Oral Implants Res , vol.1 , pp. 33-40
    • Buser, D.1    Weber, H.P.2    Lang, N.P.3
  • 14
    • 0027034910 scopus 로고
    • Radiographic evaluation of crestal bone levels adjacent to nonsubmerged titanium implants
    • Weber HP, Buser D, Fiorellini JP, Williams RC. Radiographic evaluation of crestal bone levels adjacent to nonsubmerged titanium implants. Clin Oral Implants Res 1992;3:181-188.
    • (1992) Clin Oral Implants Res , vol.3 , pp. 181-188
    • Weber, H.P.1    Buser, D.2    Fiorellini, J.P.3    Williams, R.C.4
  • 15
    • 0031151465 scopus 로고    scopus 로고
    • Immediate loading of Brånemark implants in edentulous mandibles: A preliminary report
    • Balshi TJ, Wolfinger GJ. Immediate loading of Brånemark implants in edentulous mandibles: A preliminary report. Implant Dent 1997;6:83-88.
    • (1997) Implant Dent , vol.6 , pp. 83-88
    • Balshi, T.J.1    Wolfinger, G.J.2
  • 16
    • 0034139628 scopus 로고    scopus 로고
    • Immediate functional loading of Brånemark single tooth implants: An 18 months' clinical pilot follow-up study
    • Ericsson I, Nilson H, Lindh T, Randow K. Immediate functional loading of Brånemark single tooth implants: An 18 months' clinical pilot follow-up study. Clin Oral Implants Res 2000;11:26-33.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 26-33
    • Ericsson, I.1    Nilson, H.2    Lindh, T.3    Randow, K.4
  • 17
    • 0025582810 scopus 로고
    • Immediate loading of cylinder implants with overdentures in the mandibular symphysis: The titanium plasma-sprayed screw technique
    • Lefkove MD, Beals RP. Immediate loading of cylinder implants with overdentures in the mandibular symphysis: The titanium plasma-sprayed screw technique. J Oral Implantol 1990;16:265-271.
    • (1990) J Oral Implantol , vol.16 , pp. 265-271
    • Lefkove, M.D.1    Beals, R.P.2
  • 18
  • 19
    • 0030981647 scopus 로고    scopus 로고
    • Immediate loading of titanium plasma-sprayed screw-shaped implants in man: A clinical and histological report of two cases
    • Piattelli A, Paolantonio M, Corigliano M, Scarano A. Immediate loading of titanium plasma-sprayed screw-shaped implants in man: A clinical and histological report of two cases. J Periodontol 1997;68:591-597.
    • (1997) J Periodontol , vol.68 , pp. 591-597
    • Piattelli, A.1    Paolantonio, M.2    Corigliano, M.3    Scarano, A.4
  • 20
    • 0033072986 scopus 로고    scopus 로고
    • Immediate functional loading of Brånemark dental implants: An 18-month clinical follow-up study
    • Randow K, Ericsson I, Nilner K, Petersson A, Glantz PO. Immediate functional loading of Brånemark dental implants: An 18-month clinical follow-up study. Clin Oral Implants Res 1999;10:8-15.
    • (1999) Clin Oral Implants Res , vol.10 , pp. 8-15
    • Randow, K.1    Ericsson, I.2    Nilner, K.3    Petersson, A.4    Glantz, P.O.5
  • 21
    • 0036362362 scopus 로고    scopus 로고
    • Histologic and histomorphometric evaluation of periimplant bone subjected to immediate loading: An experimental study with Macaca fascicularis
    • Romanos GE, Toh CG, Siar CH, Swaminathan D. Histologic and histomorphometric evaluation of periimplant bone subjected to immediate loading: An experimental study with Macaca fascicularis. Int J Oral Maxillofac Implants 2002;17:44-51.
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 44-51
    • Romanos, G.E.1    Toh, C.G.2    Siar, C.H.3    Swaminathan, D.4
  • 22
    • 3042577848 scopus 로고    scopus 로고
    • Immediate occlusal loading of Osseotite implants in the lower edentulous jaw: A munticenter prospective study
    • Testori T, Meltzer A, Del Fabbro M, et al. Immediate occlusal loading of Osseotite implants in the lower edentulous jaw: A munticenter prospective study. Clin Oral Implants Res 2004;15:278-284.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 278-284
    • Testori, T.1    Meltzer, A.2    Del Fabbro, M.3
  • 23
    • 0031136510 scopus 로고    scopus 로고
    • Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1- to 5-year data
    • Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1- to 5-year data. Int J Oral Maxillofac Implants 1997;12:319-324.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 319-324
    • Tarnow, D.P.1    Emtiaz, S.2    Classi, A.3
  • 24
    • 0035407071 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with Brånemark System MKII implants: A prospective comparative study between delayed and immediate loading
    • Chiapasco M, Abati S, Romeo E, Vogel G. Implant-retained mandibular overdentures with Brånemark System MKII implants: A prospective comparative study between delayed and immediate loading. Int J Oral Maxillofac Implants 2001;16:537-546.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 537-546
    • Chiapasco, M.1    Abati, S.2    Romeo, E.3    Vogel, G.4
  • 25
    • 0031061750 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading: A retrospective multicenter study on 226 consecutive cases
    • Chiapasco M, Gatti C, Rossi E, Haefliger W, Markwalder TH. Implant-retained mandibular overdentures with immediate loading: A retrospective multicenter study on 226 consecutive cases. Clin Oral Implants Res 1997;8:48-57.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 48-57
    • Chiapasco, M.1    Gatti, C.2    Rossi, E.3    Haefliger, W.4    Markwalder, T.H.5
  • 26
    • 0033302136 scopus 로고    scopus 로고
    • Brånemark Novum: A new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study
    • Brånemark PI, Engstrand P, Ohrnell LO, et al. Brånemark Novum: A new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study. Clin Implant Dent Relat Res 1999;1:2-16.
    • (1999) Clin Implant Dent Relat Res , vol.1 , pp. 2-16
    • Brånemark, P.I.1    Engstrand, P.2    Ohrnell, L.O.3
  • 27
    • 0029348226 scopus 로고
    • Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics - A technique reexamined: Two case reports
    • Salama H, Rose LF, Salama M, Betts NJ. Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics - A technique reexamined: Two case reports. Int J Periodontics Restorative Dent 1995;15:344-361.
    • (1995) Int J Periodontics Restorative Dent , vol.15 , pp. 344-361
    • Salama, H.1    Rose, L.F.2    Salama, M.3    Betts, N.J.4
  • 29
    • 0035487836 scopus 로고    scopus 로고
    • Immediate loading of Osseotite implants: A case report and histologic analysis after 4 months of occlusal loading
    • Testori T, Szmukler-Moncler S, Francetti L, et al. Immediate loading of Osseotite implants: A case report and histologic analysis after 4 months of occlusal loading. Int J Periodontics Restorative Dent 2001;21:451-459.
    • (2001) Int J Periodontics Restorative Dent , vol.21 , pp. 451-459
    • Testori, T.1    Szmukler-Moncler, S.2    Francetti, L.3
  • 30
    • 11444252938 scopus 로고    scopus 로고
    • Immediate loading of 2 interforaminal dental implants supporting an overdenture: Clinical and radiographic results after 24 months
    • Stricker A, Gutwald R, Schmelzeisen R, Gellrich NG. Immediate loading of 2 interforaminal dental implants supporting an overdenture: Clinical and radiographic results after 24 months. Int J Oral Maxillofac Implants 2004;19:868-872.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 868-872
    • Stricker, A.1    Gutwald, R.2    Schmelzeisen, R.3    Gellrich, N.G.4
  • 31
    • 0041380922 scopus 로고    scopus 로고
    • Inpatient comparison of immediately loaded and non-loaded implants within 6 months
    • Lorenzoni M, Pertl C, Zhang K, Wegscheider WA. Inpatient comparison of immediately loaded and non-loaded implants within 6 months. Clin Oral Implants Res 2003a;14:273-279.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 273-279
    • Lorenzoni, M.1    Pertl, C.2    Zhang, K.3    Wegscheider, W.A.4
  • 32
    • 3042673228 scopus 로고    scopus 로고
    • The immediate rehabilitation by means of a ready-made final fixed prosthesis in the edentulous mandible: A 1-year follow-up study on 50 consecutive patients
    • van Steenberghe D, Molly L, Jacobs R, Vandekerckhove B, Quirynen M, Naert I. The immediate rehabilitation by means of a ready-made final fixed prosthesis in the edentulous mandible: A 1-year follow-up study on 50 consecutive patients. Clin Oral Implants Res 2004; 15:360-365.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 360-365
    • van Steenberghe, D.1    Molly, L.2    Jacobs, R.3    Vandekerckhove, B.4    Quirynen, M.5    Naert, I.6
  • 33
    • 0034776633 scopus 로고    scopus 로고
    • Clinical and radiographic evaluation of the papilla level adjacent to single-tooth dental implants: A retrospective study in the maxillary anterior region
    • Choquet V, Hermans M, Adriaenssens P, Daelemans P, Tarnow DP, Malevez C. Clinical and radiographic evaluation of the papilla level adjacent to single-tooth dental implants: A retrospective study in the maxillary anterior region. J Periodontol 2001;72:1364-1371.
    • (2001) J Periodontol , vol.72 , pp. 1364-1371
    • Choquet, V.1    Hermans, M.2    Adriaenssens, P.3    Daelemans, P.4    Tarnow, D.P.5    Malevez, C.6
  • 34
    • 0035404493 scopus 로고    scopus 로고
    • Interimplant papilla reconstruction: Assessment of soft tissue changes and results of 12 consecutive cases
    • Grossberg DE. Interimplant papilla reconstruction: Assessment of soft tissue changes and results of 12 consecutive cases. J Periodontol 2001;72:958-962.
    • (2001) J Periodontol , vol.72 , pp. 958-962
    • Grossberg, D.E.1
  • 35
    • 2142823714 scopus 로고    scopus 로고
    • Effect of GBR and fixture installation on gingiva and bone levels at adjacent teeth
    • Van der Zee E, Oosterveld P, Van Waas MA. Effect of GBR and fixture installation on gingiva and bone levels at adjacent teeth. Clin Oral Implants Res 2004;15:62-65.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 62-65
    • Van der Zee, E.1    Oosterveld, P.2    Van Waas, M.A.3
  • 36
    • 0033250923 scopus 로고    scopus 로고
    • Punch technique for preservation of interdental papillae at nonsubmerged implant placement
    • Auty C, Siddiqui A. Punch technique for preservation of interdental papillae at nonsubmerged implant placement. Implant Dent 1999;8:160-166.
    • (1999) Implant Dent , vol.8 , pp. 160-166
    • Auty, C.1    Siddiqui, A.2
  • 37
    • 0032059801 scopus 로고    scopus 로고
    • Soft tissue punch technique for aesthetic implant dentistry
    • Salinas TJ. Soft tissue punch technique for aesthetic implant dentistry. Pract Periodontics Aesthet Dent 1998;10:434.
    • (1998) Pract Periodontics Aesthet Dent , vol.10 , pp. 434
    • Salinas, T.J.1
  • 38
    • 0033091560 scopus 로고    scopus 로고
    • Implant placement without flaps - Part 2: Utilizing a two-stage surgical protocol
    • Landsberg CJ, Bichacho N. Implant placement without flaps - Part 2: Utilizing a two-stage surgical protocol. Pract Periodontics Aesthet Dent 1999;11:169-176.
    • (1999) Pract Periodontics Aesthet Dent , vol.11 , pp. 169-176
    • Landsberg, C.J.1    Bichacho, N.2
  • 39
    • 0036516691 scopus 로고    scopus 로고
    • Flapless implant surgery: A 10-year clinical retrospective analysis
    • Campelo LD, Camara JRD. Flapless implant surgery: A 10-year clinical retrospective analysis. Int J Oral Maxillofac Implants 2002;17:271-276.
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 271-276
    • Campelo, L.D.1    Camara, J.R.D.2
  • 40
    • 0041511733 scopus 로고    scopus 로고
    • Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: A retrospective 3-year clinical study
    • Rocci A, Martignoni M, Gottlow J. Immediate loading in the maxilla using flapless surgery, implants placed in predetermined positions, and prefabricated provisional restorations: A retrospective 3-year clinical study. Clin Implant Dent Relat Res 2003;5(Suppl. 1):29-36.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.SUPPL. 1 , pp. 29-36
    • Rocci, A.1    Martignoni, M.2    Gottlow, J.3
  • 42
    • 0037822206 scopus 로고    scopus 로고
    • Immediate loading of single-tooth implants in the anterior maxilla: Preliminary results after one year
    • Lorenzoni M, Pertl C, Zhang K, Wimmen G, Wegscheider WA. Immediate loading of single-tooth implants in the anterior maxilla: Preliminary results after one year. Clin Oral Implants Res 2003b;14:180-187.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 180-187
    • Lorenzoni, M.1    Pertl, C.2    Zhang, K.3    Wimmen, G.4    Wegscheider, W.A.5
  • 43
    • 0036618444 scopus 로고    scopus 로고
    • Immediate loading of single-tooth ITI implants in the anterior maxilla: A prospective 5-year pilot study
    • Andersen E, Haanæs HR, Knutsen BM. Immediate loading of single-tooth ITI implants in the anterior maxilla: A prospective 5-year pilot study. Clin Oral Implants Res 2002;13:281-287.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 281-287
    • Andersen, E.1    Haanæs, H.R.2    Knutsen, B.M.3
  • 44
    • 0035291732 scopus 로고    scopus 로고
    • A multicenter 12-month evaluation of single-tooth implants restored 3 weeks after 1-stage surgery
    • Cooper L, Felton DA, Kugelberg CF, et al. A multicenter 12-month evaluation of single-tooth implants restored 3 weeks after 1-stage surgery. Int J Oral Maxillofac Implants 2001;16:182-192.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 182-192
    • Cooper, L.1    Felton, D.A.2    Kugelberg, C.F.3
  • 45
    • 14844325832 scopus 로고    scopus 로고
    • Implant surgical guide fabrication for partially edentulous patients
    • Shotwell JL, Billy EJ, Wang H-L, Oh T-J. Implant surgical guide fabrication for partially edentulous patients. J Prosthet Dent 2005;93:294-297.
    • (2005) J Prosthet Dent , vol.93 , pp. 294-297
    • Shotwell, J.L.1    Billy, E.J.2    Wang, H.-L.3    Oh, T.-J.4
  • 46
    • 0031196564 scopus 로고    scopus 로고
    • Regeneration of gingival papillae after single-implant treatment
    • Jemt T. Regeneration of gingival papillae after single-implant treatment. Int J Periodontics Restorative Dent 1997;17:327-333.
    • (1997) Int J Periodontics Restorative Dent , vol.17 , pp. 327-333
    • Jemt, T.1
  • 47
    • 0023583441 scopus 로고
    • The microbiota associated with successful or failing osseointegrated titanium implants
    • Mombelli A, van Oosten MA, Schurch E Jr., Land NP. The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol Immunol 1987;2:145-151.
    • (1987) Oral Microbiol Immunol , vol.2 , pp. 145-151
    • Mombelli, A.1    van Oosten, M.A.2    Schurch Jr., E.3    Land, N.P.4
  • 49
    • 0034584224 scopus 로고    scopus 로고
    • Single-stage, immediate loading, and flapless surgery
    • Hahn J. Single-stage, immediate loading, and flapless surgery. J Oral Implantol 2000;26:193-198.
    • (2000) J Oral Implantol , vol.26 , pp. 193-198
    • Hahn, J.1
  • 50
    • 0842280595 scopus 로고    scopus 로고
    • Vertical distance from the crest of bone to the height of the interproximal papilla between adjacent implants
    • Tarnow DP, Elian N, Fletcher P, et al. Vertical distance from the crest of bone to the height of the interproximal papilla between adjacent implants. J Periodontol 2003;74:1785-1788.
    • (2003) J Periodontol , vol.74 , pp. 1785-1788
    • Tarnow, D.P.1    Elian, N.2    Fletcher, P.3
  • 51
    • 0027013273 scopus 로고
    • The effect of the distance from the contact point to the crest of bone on the presence or absence of the interproximal dental papilla
    • Tarnow DP, Magner AW, Fletcher P. The effect of the distance from the contact point to the crest of bone on the presence or absence of the interproximal dental papilla. J Periodontol 1992;63:995-996.
    • (1992) J Periodontol , vol.63 , pp. 995-996
    • Tarnow, D.P.1    Magner, A.W.2    Fletcher, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.