메뉴 건너뛰기




Volumn 66, Issue 6, 2008, Pages 1245-1252

Accuracy of Miniscrew Implant Placement With a 3-Dimensional Surgical Guide

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ANALYSIS OF VARIANCE; ANALYTICAL ERROR; ARTICLE; DENTAL SURGERY; IMPLANTATION; MEDICAL INSTRUMENTATION; PRACTICE GUIDELINE; RETROSPECTIVE STUDY; SURGICAL TECHNIQUE; TREATMENT PLANNING; WIRE FIXATION;

EID: 43449089485     PISSN: 02782391     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joms.2007.08.047     Document Type: Article
Times cited : (42)

References (43)
  • 1
    • 0033073482 scopus 로고    scopus 로고
    • Palatal bone support for bone orthodontic implant anchorage: A clinical and radiological study
    • Wehrbein H., Merz B.R., and Diedrich P. Palatal bone support for bone orthodontic implant anchorage: A clinical and radiological study. Eur J Orthod 21 (1999) 65
    • (1999) Eur J Orthod , vol.21 , pp. 65
    • Wehrbein, H.1    Merz, B.R.2    Diedrich, P.3
  • 2
    • 0033160166 scopus 로고    scopus 로고
    • A new supraconstruction for palatal orthodontic implants
    • Mannchen R. A new supraconstruction for palatal orthodontic implants. J Clin Orthod 7 (1999) 373
    • (1999) J Clin Orthod , vol.7 , pp. 373
    • Mannchen, R.1
  • 4
    • 0024846195 scopus 로고
    • Rigid endosseous implants for orthodontic and orthopedic anchorage
    • Roberts W.E., Helm F.R., Marshall K.J., et al. Rigid endosseous implants for orthodontic and orthopedic anchorage. Angle Orthod 59 (1989) 247
    • (1989) Angle Orthod , vol.59 , pp. 247
    • Roberts, W.E.1    Helm, F.R.2    Marshall, K.J.3
  • 5
    • 0025333345 scopus 로고
    • Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site
    • Roberts W.E., Marshall K.J., and Mozsary P.G. Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site. Angle Orthod 60 (1990) 135
    • (1990) Angle Orthod , vol.60 , pp. 135
    • Roberts, W.E.1    Marshall, K.J.2    Mozsary, P.G.3
  • 6
    • 0031266937 scopus 로고    scopus 로고
    • Miniscrew implant for orthodontic anchorage
    • Kanomi R. Miniscrew implant for orthodontic anchorage. J Clin Orthod 11 (1997) 763
    • (1997) J Clin Orthod , vol.11 , pp. 763
    • Kanomi, R.1
  • 7
    • 0035432240 scopus 로고    scopus 로고
    • Bicortical titanium screws for critical orthodontic anchorage in the mandible: A preliminary report on clinical applications
    • Freudenthaler J.W., Haas R., and Bantleon H.P. Bicortical titanium screws for critical orthodontic anchorage in the mandible: A preliminary report on clinical applications. Clin Oral Implants Res 12 (2001) 358
    • (2001) Clin Oral Implants Res , vol.12 , pp. 358
    • Freudenthaler, J.W.1    Haas, R.2    Bantleon, H.P.3
  • 8
    • 0035407943 scopus 로고    scopus 로고
    • Micro-implant anchorage for treatment of skeletal class I bialveolar protrusion
    • Park H.S., Bae S.M., Kyung H.M., et al. Micro-implant anchorage for treatment of skeletal class I bialveolar protrusion. J Clin Orthod 35 (2001) 417
    • (2001) J Clin Orthod , vol.35 , pp. 417
    • Park, H.S.1    Bae, S.M.2    Kyung, H.M.3
  • 9
    • 0141723508 scopus 로고    scopus 로고
    • Development of orthodontic miniscrew implants for intraoral anchorage
    • Kyung H.M., Park H.S., Bae S.M., et al. Development of orthodontic miniscrew implants for intraoral anchorage. J Clin Orthod 6 (2003) 321
    • (2003) J Clin Orthod , vol.6 , pp. 321
    • Kyung, H.M.1    Park, H.S.2    Bae, S.M.3
  • 10
    • 33745219705 scopus 로고    scopus 로고
    • Miniscrew anchorage used to protract lower second molars into first molar extraction sites
    • Kyung S.H., Choi J.H., and Park Y.C. Miniscrew anchorage used to protract lower second molars into first molar extraction sites. J Clin Orthod 37 (2003) 575
    • (2003) J Clin Orthod , vol.37 , pp. 575
    • Kyung, S.H.1    Choi, J.H.2    Park, Y.C.3
  • 11
    • 1342308955 scopus 로고    scopus 로고
    • A new bone screw for orthodontic anchorage
    • Lin J.C., and Liou E.J. A new bone screw for orthodontic anchorage. J Clin Orthod 12 (2003) 676
    • (2003) J Clin Orthod , vol.12 , pp. 676
    • Lin, J.C.1    Liou, E.J.2
  • 12
    • 16644383192 scopus 로고    scopus 로고
    • Simultaneous incisor retraction and distal molar movement with microimplant anchorage
    • Park H.S., Bae S.M., Kyung H.M., et al. Simultaneous incisor retraction and distal molar movement with microimplant anchorage. World J Orthod 5 (2004) 164
    • (2004) World J Orthod , vol.5 , pp. 164
    • Park, H.S.1    Bae, S.M.2    Kyung, H.M.3
  • 13
    • 26944443746 scopus 로고    scopus 로고
    • Micro-screw implant anchorage sliding mechanics
    • Park H.S., Kwon O.W., and Sung J.H. Micro-screw implant anchorage sliding mechanics. World J Orthod 6 (2005) 265
    • (2005) World J Orthod , vol.6 , pp. 265
    • Park, H.S.1    Kwon, O.W.2    Sung, J.H.3
  • 14
    • 33644818483 scopus 로고    scopus 로고
    • Molar control using indirect miniscrew anchorage
    • Yun S.W., Lim W.H., and Chun Y.S. Molar control using indirect miniscrew anchorage. J Clin Orthod 39 (2005) 661
    • (2005) J Clin Orthod , vol.39 , pp. 661
    • Yun, S.W.1    Lim, W.H.2    Chun, Y.S.3
  • 15
    • 0036580590 scopus 로고    scopus 로고
    • Clinical application of micro-implant anchorage
    • Bae S.M., Park H.S., Kyung H.M., et al. Clinical application of micro-implant anchorage. J Clin Orthod 36 (2002) 298
    • (2002) J Clin Orthod , vol.36 , pp. 298
    • Bae, S.M.1    Park, H.S.2    Kyung, H.M.3
  • 16
    • 33747022474 scopus 로고    scopus 로고
    • Correction of a canted occlusal plane with miniscrews in a patient with facial asymmetry
    • Jeon Y.J., Kim Y.H., Son W.S., et al. Correction of a canted occlusal plane with miniscrews in a patient with facial asymmetry. Am J Orthod Dentofac Orthop 130 (2006) 244
    • (2006) Am J Orthod Dentofac Orthop , vol.130 , pp. 244
    • Jeon, Y.J.1    Kim, Y.H.2    Son, W.S.3
  • 17
    • 39049181921 scopus 로고    scopus 로고
    • En-masse distalization with miniscrew anchorage in class II nonextraction treatment
    • Jeon J.M., Yu H.S., Baik H.S., et al. En-masse distalization with miniscrew anchorage in class II nonextraction treatment. J Clin Orthod 40 (2006) 472
    • (2006) J Clin Orthod , vol.40 , pp. 472
    • Jeon, J.M.1    Yu, H.S.2    Baik, H.S.3
  • 18
    • 33644986334 scopus 로고    scopus 로고
    • Maxillary molar intrusion with micro-implant anchorage (MIA)
    • Park H.S., Jang B.K., and Kyung H.M. Maxillary molar intrusion with micro-implant anchorage (MIA). Aust Orthod J 21 (2005) 129
    • (2005) Aust Orthod J , vol.21 , pp. 129
    • Park, H.S.1    Jang, B.K.2    Kyung, H.M.3
  • 19
    • 4444249537 scopus 로고    scopus 로고
    • Nonextraction treatment with micro-screw implants
    • Park H.S., Kwon T.G., and Sung J.H. Nonextraction treatment with micro-screw implants. Angle Orthod 74 (2004) 539
    • (2004) Angle Orthod , vol.74 , pp. 539
    • Park, H.S.1    Kwon, T.G.2    Sung, J.H.3
  • 20
    • 1642303902 scopus 로고    scopus 로고
    • Uprighting second molars with micro-implant anchorage
    • Park H.S., Kwon O.W., and Sung J.H. Uprighting second molars with micro-implant anchorage. J Clin Orthod 38 (2004) 100
    • (2004) J Clin Orthod , vol.38 , pp. 100
    • Park, H.S.1    Kwon, O.W.2    Sung, J.H.3
  • 21
    • 7544245529 scopus 로고    scopus 로고
    • Treatment of open bite with micro-screw implant anchorage
    • Park H.S., Kwon T.G., and Kwon O.W. Treatment of open bite with micro-screw implant anchorage. Am J Orthod Dentofac Orthop 126 (2004) 627
    • (2004) Am J Orthod Dentofac Orthop , vol.126 , pp. 627
    • Park, H.S.1    Kwon, T.G.2    Kwon, O.W.3
  • 22
    • 0035492033 scopus 로고    scopus 로고
    • Micro-implant anchorage for lingual treatment of a skeletal class II malocclusion
    • Lee J.S., Park H.S., and Kyung H.M. Micro-implant anchorage for lingual treatment of a skeletal class II malocclusion. J Clin Orthod 35 (2001) 643
    • (2001) J Clin Orthod , vol.35 , pp. 643
    • Lee, J.S.1    Park, H.S.2    Kyung, H.M.3
  • 23
    • 4844229252 scopus 로고    scopus 로고
    • Clinical suitability of titanium micro-screws for orthodontic anchorage: Preliminary experiences
    • Fritz U., Ehmer A., and Diedrich P. Clinical suitability of titanium micro-screws for orthodontic anchorage: Preliminary experiences. J Orofac Orthop 65 (2004) 410
    • (2004) J Orofac Orthop , vol.65 , pp. 410
    • Fritz, U.1    Ehmer, A.2    Diedrich, P.3
  • 24
    • 16644381734 scopus 로고    scopus 로고
    • Clinical applications of the Mini-Screw Anchorage System (MAS) in the maxillary alveolar bone
    • Carano A., Velo S., Incorvati C., et al. Clinical applications of the Mini-Screw Anchorage System (MAS) in the maxillary alveolar bone. Prog Orthod 5 (2004) 212
    • (2004) Prog Orthod , vol.5 , pp. 212
    • Carano, A.1    Velo, S.2    Incorvati, C.3
  • 25
    • 14744278438 scopus 로고    scopus 로고
    • Clinical applications of the Miniscrew Anchorage System
    • Carano A., Velo S., Leone P., et al. Clinical applications of the Miniscrew Anchorage System. J Clin Orthod 39 (2005) 9
    • (2005) J Clin Orthod , vol.39 , pp. 9
    • Carano, A.1    Velo, S.2    Leone, P.3
  • 26
    • 0037607384 scopus 로고    scopus 로고
    • The spider screw for skeletal anchorage
    • Maino B.G., Bednar J., Pagin P., et al. The spider screw for skeletal anchorage. J Clin Orthod 37 (2003) 90
    • (2003) J Clin Orthod , vol.37 , pp. 90
    • Maino, B.G.1    Bednar, J.2    Pagin, P.3
  • 27
    • 21444457307 scopus 로고    scopus 로고
    • Spider screw: A skeletal anchorage system
    • Maino B.G., Maino G., and Mura P. Spider screw: A skeletal anchorage system. Prog Orthod 6 (2005) 70
    • (2005) Prog Orthod , vol.6 , pp. 70
    • Maino, B.G.1    Maino, G.2    Mura, P.3
  • 28
    • 14544272341 scopus 로고    scopus 로고
    • Miniscrew implants: The spider screw anchorage system
    • Maino B.G., Mura P., and Bednar J. Miniscrew implants: The spider screw anchorage system. Semin Orthod 11 (2005) 40
    • (2005) Semin Orthod , vol.11 , pp. 40
    • Maino, B.G.1    Mura, P.2    Bednar, J.3
  • 29
    • 14544303622 scopus 로고    scopus 로고
    • Miniscrew implants: IMTEC Mini Ortho implants
    • Herman R., and Cope J.B. Miniscrew implants: IMTEC Mini Ortho implants. Semin Orthod 11 (2005) 32
    • (2005) Semin Orthod , vol.11 , pp. 32
    • Herman, R.1    Cope, J.B.2
  • 30
    • 33644639434 scopus 로고    scopus 로고
    • "Safe zones": A guide for miniscrew positioning in the maxillary and mandibular arch
    • Poggio P.M., Incorvati C., Velo S., et al. "Safe zones": A guide for miniscrew positioning in the maxillary and mandibular arch. Angle Orthod 76 (2006) 191
    • (2006) Angle Orthod , vol.76 , pp. 191
    • Poggio, P.M.1    Incorvati, C.2    Velo, S.3
  • 31
    • 33744930120 scopus 로고    scopus 로고
    • Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants
    • Deguchi T., Nasu M., Murakami K., et al. Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants. Am J Orthod Dentofac Orthop 129 (2006) 721
    • (2006) Am J Orthod Dentofac Orthop , vol.129 , pp. 721
    • Deguchi, T.1    Nasu, M.2    Murakami, K.3
  • 32
    • 15944372612 scopus 로고    scopus 로고
    • Evaluation of the implantation position of mini-screws for orthodontic treatment in the maxillary molar area by a micro CT
    • Ishii T., Nojima K., Nishii Y., et al. Evaluation of the implantation position of mini-screws for orthodontic treatment in the maxillary molar area by a micro CT. Bull Tokyo Dent Coll 45 (2004) 165
    • (2004) Bull Tokyo Dent Coll , vol.45 , pp. 165
    • Ishii, T.1    Nojima, K.2    Nishii, Y.3
  • 33
    • 12444293764 scopus 로고    scopus 로고
    • A radiographic evaluation of the availability of bone for placement of miniscrews
    • Schnelle M.A., Beck F.M., Jaynes R.M., et al. A radiographic evaluation of the availability of bone for placement of miniscrews. Angle Orthod 74 (2004) 832
    • (2004) Angle Orthod , vol.74 , pp. 832
    • Schnelle, M.A.1    Beck, F.M.2    Jaynes, R.M.3
  • 34
    • 0036980421 scopus 로고    scopus 로고
    • A stent fabricated on a selectively colored stereolithographic model for placement of orthodontic mini-implants
    • Kitai N., Yasuda Y., and Takada K. A stent fabricated on a selectively colored stereolithographic model for placement of orthodontic mini-implants. Int J Adult Orthod Orthognath Surg 17 (2002) 264
    • (2002) Int J Adult Orthod Orthognath Surg , vol.17 , pp. 264
    • Kitai, N.1    Yasuda, Y.2    Takada, K.3
  • 35
    • 23244458826 scopus 로고    scopus 로고
    • Surgical guide for optimal positioning of mini-implants
    • Morea C., Dominguez G.C., Wuo Ado V., et al. Surgical guide for optimal positioning of mini-implants. J Clin Orthod 39 (2005) 317
    • (2005) J Clin Orthod , vol.39 , pp. 317
    • Morea, C.1    Dominguez, G.C.2    Wuo Ado, V.3
  • 36
    • 33748749089 scopus 로고    scopus 로고
    • Surgical stents for accurate miniscrew insertion
    • Cousley R.R., and Parberry D.J. Surgical stents for accurate miniscrew insertion. J Clin Orthod 40 (2006) 412
    • (2006) J Clin Orthod , vol.40 , pp. 412
    • Cousley, R.R.1    Parberry, D.J.2
  • 37
    • 0036719664 scopus 로고    scopus 로고
    • Template fabrication for a midpalatal orthodontic implant: Technical note
    • Martin W., Heffernan M., and Ruskin J. Template fabrication for a midpalatal orthodontic implant: Technical note. Int J Oral Maxillofac Implants 17 (2002) 720
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 720
    • Martin, W.1    Heffernan, M.2    Ruskin, J.3
  • 38
    • 33644694854 scopus 로고    scopus 로고
    • An adjustable surgical guide for miniscrew placement
    • Suzuki E.Y., and Buranastidporn B. An adjustable surgical guide for miniscrew placement. J Clin Orthod 39 (2005) 588
    • (2005) J Clin Orthod , vol.39 , pp. 588
    • Suzuki, E.Y.1    Buranastidporn, B.2
  • 40
    • 0031602297 scopus 로고    scopus 로고
    • Three-dimensional guidance system for implant insertion: Part I
    • Weinberg L.A., and Kruger B. Three-dimensional guidance system for implant insertion: Part I. Implant Dent 2 (1998) 81
    • (1998) Implant Dent , vol.2 , pp. 81
    • Weinberg, L.A.1    Kruger, B.2
  • 41
    • 0030278824 scopus 로고    scopus 로고
    • Three-dimensional templates for placement of root-form dental implants: A technical note
    • Higginbottom F.L., and Wilson T.G. Three-dimensional templates for placement of root-form dental implants: A technical note. Int J Oral Maxilofac Implants 11 (1996) 787
    • (1996) Int J Oral Maxilofac Implants , vol.11 , pp. 787
    • Higginbottom, F.L.1    Wilson, T.G.2
  • 42
    • 0036886962 scopus 로고    scopus 로고
    • A dual-purpose guide for optimum placement of dental implants
    • Cehreli M.C., Calis A.C., and Sahin S. A dual-purpose guide for optimum placement of dental implants. J Prosthet Dent 88 (2002) 640
    • (2002) J Prosthet Dent , vol.88 , pp. 640
    • Cehreli, M.C.1    Calis, A.C.2    Sahin, S.3
  • 43
    • 0035350222 scopus 로고    scopus 로고
    • Fabrication of imaging and surgical guides for dental implants
    • Almog D.M., Torrado E., and Meitner S.W. Fabrication of imaging and surgical guides for dental implants. J Prosthet Dent 85 (2001) 504
    • (2001) J Prosthet Dent , vol.85 , pp. 504
    • Almog, D.M.1    Torrado, E.2    Meitner, S.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.