Computed tomography-guided navigation of thoracic pedicle screws for adolescent idiopathic scoliosis results in more accurate placement and less screw removal

Author keywords

adolescent idiopathic scoliosis; navigation; O arm; pedicle screw

Indexed keywords

ADOLESCENT; ADOLESCENT DISEASE; ARTICLE; CHILD; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER TOMOGRAPHY GUIDED NAVIGATION; CONTROLLED STUDY; DEVICE REMOVAL; DEVICE SAFETY; FEMALE; HEART VENTRICLE EXTRASYSTOLE; HUMAN; IDIOPATHIC SCOLIOSIS; INTERMETHOD COMPARISON; INTRAOPERATIVE PERIOD; MALE; PEDICLE SCREW; PLEURA EFFUSION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SCHOOL CHILD; SINUS TACHYCARDIA; SPINE FUSION; T WAVE; VERTEBRA BODY;

EID: 84860001235     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e318238bbd9     Document Type: Article
Times cited : (106)

References (48)
  • 1
    • 0033794424 scopus 로고    scopus 로고
    • The use of pedicle-screw internal fi xation for the operative treatment of spinal disorders
    • Gaines RW. The use of pedicle-screw internal fi xation for the operative treatment of spinal disorders. J Bone Joint Surg Am 2000; 82- A: 1458-76.
    • (2000) J Bone Joint Surg Am , vol.82 A , pp. 1458-1476
    • Gaines, R.W.1
  • 2
    • 0033119287 scopus 로고    scopus 로고
    • Pedicle and transverse process screws of the upper thoracic spine: Biomechanical comparison of loads to failure
    • DOI 10.1097/00007632-199904010-00008
    • Heller JG, Shuster JK, Hutton WC. Pedicle and transverse process screws of the upper thoracic spine. Biomechanical comparison of loads to failure. Spine 1999; 24: 654-8. (Pubitemid 29162907)
    • (1999) Spine , vol.24 , Issue.7 , pp. 654-658
    • Heller, J.G.1    Shuster, J.K.2    Hutton, W.C.3
  • 3
    • 13444291573 scopus 로고    scopus 로고
    • Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis
    • DOI 10.1097/01.brs.0000138268.12324.1a
    • Kim YJ, Lenke LG, Cho SK, et al. Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis. Spine 2004; 29: 2040-8. (Pubitemid 40202276)
    • (2004) Spine , vol.29 , Issue.18 , pp. 2040-2048
    • Kim, Y.J.1    Lenke, L.G.2    Cho, S.K.3    Bridwell, K.H.4    Sides, B.5    Blanke, K.6
  • 5
    • 0141478986 scopus 로고    scopus 로고
    • Straight-forward Versus anatomic trajectory technique of thoracic pedicle screw fixation: A biomechanical analysis
    • DOI 10.1097/01.BRS.0000087743.57439.4F
    • Lehman RA Jr., Polly DW Jr., Kuklo TR, et al. Straight-forward versus anatomic trajectory technique of thoracic pedicle screw fi xation: a biomechanical analysis. Spine 2003; 28: 2058-65. (Pubitemid 37140192)
    • (2003) Spine , vol.28 , Issue.18 , pp. 2058-2065
    • Lehman Jr., R.A.1    Polly Jr., D.W.2    Kuklo, T.R.3    Cunningham, B.4    Kirk, K.L.5    Belmont Jr., P.J.6
  • 6
    • 74249103230 scopus 로고    scopus 로고
    • Feasibility and accuracy of pedicle screws in children younger than eight years of age
    • Ranade A, Samdani AF, Williams R, et al. Feasibility and accuracy of pedicle screws in children younger than eight years of age. Spine 2009; 34: 2907-11.
    • (2009) Spine , vol.34 , pp. 2907-2911
    • Ranade, A.1    Samdani, A.F.2    Williams, R.3
  • 7
    • 0035884966 scopus 로고    scopus 로고
    • Thoracic pedicle screw fi xation in spinal deformities: Are they really safe?
    • Suk SI, Kim WJ, Lee SM, et al. Thoracic pedicle screw fi xation in spinal deformities: are they really safe? Spine 2001; 26: 2049-57.
    • (2001) Spine , vol.26 , pp. 2049-2057
    • Suk, S.I.1    Kim, W.J.2    Lee, S.M.3
  • 9
    • 34447305748 scopus 로고    scopus 로고
    • Complications of thoracic pedicle screws in scoliosis treatment
    • DOI 10.1097/BRS.0b013e318074d604, PII 0000763220070701000014
    • Di Silvestre M, Parisini P, Lolli F, et al. Complications of thoracic pedicle screws in scoliosis treatment. Spine 2007; 32: 1655-61. (Pubitemid 47051850)
    • (2007) Spine , vol.32 , Issue.15 , pp. 1655-1661
    • Di Silvestre, M.1    Parisini, P.2    Lolli, F.3    Bakaloudis, G.4
  • 10
    • 0030814925 scopus 로고    scopus 로고
    • Early complications of spinal pedicle screw
    • DOI 10.1007/BF01142678
    • Faraj AA, Webb JK. Early complications of spinal pedicle screw. Eur Spine J 1997; 6: 324-6. . (Pubitemid 27471154)
    • (1997) European Spine Journal , vol.6 , Issue.5 , pp. 324-326
    • Faraj, A.A.1    Webb, J.K.2
  • 11
    • 77952369629 scopus 로고    scopus 로고
    • Complications of pedicle screw fi xation in scoliosis surgery: A systematic review
    • Hicks JM, Singla A, Shen FH, et al. Complications of pedicle screw fi xation in scoliosis surgery: a systematic review. Spine 2010; 35: E465-70.
    • (2010) Spine , vol.35
    • Hicks, J.M.1    Singla, A.2    Shen, F.H.3
  • 13
    • 0029098570 scopus 로고
    • Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment
    • Vaccaro AR, Rizzolo SJ, Balderston RA, et al. Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment. J Bone Joint Surg Am 1995; 77: 1200-6.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1200-1206
    • Vaccaro, A.R.1    Rizzolo, S.J.2    Balderston, R.A.3
  • 14
    • 0043136470 scopus 로고    scopus 로고
    • The position of the aorta relative to the spine: A comparison of patients with and without idiopathic scoliosis
    • Sucato DJ, Duchene C. The position of the aorta relative to the spine: a comparison of patients with and without idiopathic scoliosis . J Bone Joint Surg Am 2003; 85-A: 1461-9. (Pubitemid 36951129)
    • (2003) Journal of Bone and Joint Surgery - Series A , vol.85 , Issue.8 , pp. 1461-1469
    • Sucato, D.J.1    Duchene, C.2
  • 15
    • 34249085896 scopus 로고    scopus 로고
    • The position of the aorta relative to the spine in patients with left thoracic scoliosis: A comparison with normal patients
    • DOI 10.1097/BRS.0b013e318059aeda, PII 0000763220070520000018
    • Milbrandt TA, Sucato DJ. The position of the aorta relative to the spine in patients with left thoracic scoliosis: a comparison with normal patients. Spine 2007; 32: E348-53. (Pubitemid 46791457)
    • (2007) Spine , vol.32 , Issue.12
    • Milbrandt, T.A.1    Sucato, D.J.2
  • 17
    • 0034657219 scopus 로고    scopus 로고
    • Morphometric analysis of thoracic and lumbar vertebrae in idiopathic scoliosis
    • DOI 10.1097/00007632-200005150-00008
    • Liljenqvist UR, Link TM, Halm HF. Morphometric analysis of thoracic and lumbar vertebrae in idiopathic scoliosis. Spine 2000; 25: 1247-53. (Pubitemid 30322315)
    • (2000) Spine , vol.25 , Issue.10 , pp. 1247-1253
    • Liljenqvist, U.R.1    Link, T.M.2    Halm, H.F.H.3
  • 18
    • 0742269914 scopus 로고    scopus 로고
    • Free Hand Pedicle Screw Placement in the Thoracic Spine: Is it Safe
    • DOI 10.1097/01.BRS.0000109983.12113.9B
    • Kim YJ, Lenke LG, Bridwell KH, et al. Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 2004; 29: 333-42. (Pubitemid 38155737)
    • (2004) Spine , vol.29 , Issue.3 , pp. 333-342
    • Kim, Y.J.1    Lenke, L.G.2    Bridwell, K.H.3    Cho, Y.S.4    Riew, K.D.5
  • 19
    • 33846683025 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy: A meta-analysis
    • DOI 10.1097/01.brs.0000254048.79024.8b, PII 0000763220070201000022
    • Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine 2007; 32: E111-20. (Pubitemid 46197463)
    • (2007) Spine , vol.32 , Issue.3
    • Kosmopoulos, V.1    Schizas, C.2
  • 20
    • 36248940132 scopus 로고    scopus 로고
    • Computed tomography evaluation of pedicle screws placed in the pediatric deformed spine over an 8-year period
    • DOI 10.1097/BRS.0b013e31815a7f13, PII 0000763220071115000008
    • Lehman RA Jr., Lenke LG, Keeler KA, et al. Computed tomography evaluation of pedicle screws placed in the pediatric deformed spine over an 8-year period. Spine 2007; 32: 2679-84. (Pubitemid 350135379)
    • (2007) Spine , vol.32 , Issue.24 , pp. 2679-2684
    • Lehman Jr., R.A.1    Lenke, L.G.2    Keeler, K.A.3    Kim, Y.J.4    Cheh, G.5
  • 21
    • 64249146979 scopus 로고    scopus 로고
    • Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand technique
    • Modi H, Suh SW, Song H-R, et al. Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand technique. Int Orthop 2008; 33: 469-75.
    • (2008) Int Orthop , vol.33 , pp. 469-475
    • Modi, H.1    Suh, S.W.2    Song, H.-R.3
  • 22
    • 34248512369 scopus 로고    scopus 로고
    • Inserting pedicle screws in the upper thoracic spine without the use of fluoroscopy or image guidance. Is it safe?
    • DOI 10.1007/s00586-006-0262-1
    • Schizas C, Theumann N, Kosmopoulos V. Inserting pedicle screws in the upper thoracic spine without the use of fl uoroscopy or image guidance. Is it safe? Eur Spine J 2007; 16: 625-9. (Pubitemid 46764001)
    • (2007) European Spine Journal , vol.16 , Issue.5 , pp. 625-629
    • Schizas, C.1    Theumann, N.2    Kosmopoulos, V.3
  • 23
    • 0032532465 scopus 로고    scopus 로고
    • Clinical relevance of accuracy of pedicle screw placement: A computed tomographic-supported analysis
    • DOI 10.1097/00007632-199810150-00014
    • Schulze CJ, Munzinger E, Weber U. Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis. Spine 1998; 23: 2215-20. (Pubitemid 28485179)
    • (1998) Spine , vol.23 , Issue.20 , pp. 2215-2220
    • Schulze, C.J.1    Munzinger, E.2    Weber, U.3
  • 24
    • 0029156076 scopus 로고
    • Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae
    • Vaccaro AR, Rizzolo SJ, Allardyce TJ, et al. Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 1995; 77: 1193-9.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1193-1199
    • Vaccaro, A.R.1    Rizzolo, S.J.2    Allardyce, T.J.3
  • 25
    • 0033555322 scopus 로고    scopus 로고
    • Pedicle instrumentation in the thoracic spine: A morphometric and cadaveric study for placement of screws
    • DOI 10.1097/00007632-199901150-00003
    • Cinotti G, Gumina S, Ripani M, et al. Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine 1999; 24: 114-9. (Pubitemid 29042758)
    • (1999) Spine , vol.24 , Issue.2 , pp. 114-119
    • Cinotti, G.1    Gumina, S.2    Ripani, M.3    Postacchini, F.4
  • 26
    • 25444518981 scopus 로고    scopus 로고
    • Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: A comparison with computerized tomography
    • DOI 10.1097/01.brs.0000178818.92105.ec
    • Kim YJ, Lenke LG, Cheh G, et al. Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: a comparison with computerized tomography. Spine 2005; 30: 2084-8. (Pubitemid 41362371)
    • (2005) Spine , vol.30 , Issue.18 , pp. 2084-2088
    • Kim, Y.J.1    Lenke, L.G.2    Cheh, G.3    Riew, K.D.4
  • 27
    • 75749088429 scopus 로고    scopus 로고
    • Learning curve for placement of thoracic pedicle screws in the deformed spine
    • Samdani AF, Ranade A, Saldanha V, et al. Learning curve for placement of thoracic pedicle screws in the deformed spine. Neurosurgery 2010; 66: 290-5.
    • (2010) Neurosurgery , vol.66 , pp. 290-295
    • Samdani, A.F.1    Ranade, A.2    Saldanha, V.3
  • 28
    • 0034061781 scopus 로고
    • Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    • Amiot LP, Lang K, Putzier M, et al. Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine (Phila Pa 1976) 2000; 25: 606-14.
    • (1976) Spine (Phila Pa , vol.25 , pp. 606-614
    • Amiot, L.P.1    Lang, K.2    Putzier, M.3
  • 29
    • 33750075179 scopus 로고    scopus 로고
    • Miniature robotic guidance for spine surgery - Introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres
    • DOI 10.1002/rcs.90
    • Barzilay Y, Liebergall M, Fridlander A, et al. Miniature robotic guidance for spine surgery-introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres. Int J Med Robot 2006; 2: 146-53. (Pubitemid 44580033)
    • (2006) International Journal of Medical Robotics and Computer Assisted Surgery , vol.2 , Issue.2 , pp. 146-153
    • Barzilay, Y.1    Liebergall, M.2    Fridlander, A.3    Knoller, N.4
  • 30
    • 78649412164 scopus 로고    scopus 로고
    • Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: Retrospective study
    • Devito DP, Kaplan L, Dietl R, et al. Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study. Spine 2010; 35: 2109-15.
    • (2010) Spine , vol.35 , pp. 2109-2115
    • Devito, D.P.1    Kaplan, L.2    Dietl, R.3
  • 31
    • 64749105814 scopus 로고    scopus 로고
    • Intraosseous ultrasound in the placement of pedicle screws in the lumbar spine
    • Kantelhardt SR, Bock CH, Larsen J, et al. Intraosseous ultrasound in the placement of pedicle screws in the lumbar spine. Spine 2009; 34: 400-7.
    • (2009) Spine , vol.34 , pp. 400-407
    • Kantelhardt, S.R.1    Bock, C.H.2    Larsen, J.3
  • 32
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M, et al. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 2000; 9: 235-40.
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3
  • 33
    • 0030926450 scopus 로고    scopus 로고
    • Improved accuracy of pedicle screw insertion with computer-assisted surgery: A prospective clinical trial of 30 patients
    • DOI 10.1097/00007632-199706010-00018
    • Laine T, Schlenzka D, Makitalo K, et al. Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine 1997; 22: 1254-8. (Pubitemid 27259842)
    • (1997) Spine , vol.22 , Issue.11 , pp. 1254-1258
    • Laine, T.1    Schlenzka, D.2    Makitalo, K.3    Tallroth, K.4    Nolte, L.-P.5    Visarius, H.6
  • 34
    • 61549092238 scopus 로고    scopus 로고
    • Placement of thoracolumbar pedicle screws using three-dimensional image guidance: Experience in a large patient cohort
    • Nottmeier EW, Seemer W, Young PM. Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort. J Neurosurg Spine 2009; 10: 33-9.
    • (2009) J Neurosurg Spine , vol.10 , pp. 33-39
    • Nottmeier, E.W.1    Seemer, W.2    Young, P.M.3
  • 35
    • 33846239956 scopus 로고    scopus 로고
    • Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries
    • DOI 10.1097/01.brs.0000252094.64857.ab, PII 0000763220070115000030
    • Rajasekaran S, Vidyadhara S, Ramesh P, et al. Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine 2007; 32: E56-64. (Pubitemid 46105794)
    • (2007) Spine , vol.32 , Issue.2
    • Rajasekaran, S.1    Vidyadhara, S.2    Ramesh, P.3    Shetty, A.P.4
  • 36
    • 33644877691 scopus 로고    scopus 로고
    • Clinical accuracy of fl uoroscopic computer-assisted pedicle screw fi xation: A CT analysis
    • Rampersaud YR, Pik JH, Salonen D, et al. Clinical accuracy of fl uoroscopic computer-assisted pedicle screw fi xation: a CT analysis. Spine 2005; 30: E183-90.
    • (2005) Spine , vol.30
    • Rampersaud, Y.R.1    Pik, J.H.2    Salonen, D.3
  • 38
    • 58149291992 scopus 로고    scopus 로고
    • Comparison of radiation exposure in lumbar pedicle screw placement with fl uoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging
    • Smith HE, Welsch MD, Sasso RC, et al. Comparison of radiation exposure in lumbar pedicle screw placement with fl uoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging. J Spinal Cord Med 2008; 31: 532-7.
    • (2008) J Spinal Cord Med , vol.31 , pp. 532-537
    • Smith, H.E.1    Welsch, M.D.2    Sasso, R.C.3
  • 40
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine 1990; 15: 11-4. (Pubitemid 20102491)
    • (1990) Spine , vol.15 , Issue.1 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 41
    • 0031837773 scopus 로고    scopus 로고
    • Biomechanical study of lumbar pedicle screws: Does convergence affect axial pullout strength?
    • Barber JW, Boden SD, Ganey T, et al. Biomechanical study of lumbar pedicle screws: does convergence affect axial pullout strength? J Spinal Disord 1998; 11: 215-20. (Pubitemid 28278167)
    • (1998) Journal of Spinal Disorders , vol.11 , Issue.3 , pp. 215-220
    • Barber, J.W.1    Boden, S.D.2    Ganey, T.3    Hutton, W.C.4
  • 42
    • 0025165338 scopus 로고
    • Internal forces and moments in transpedicular spine instrumentation: The effect of pedicle screw angle and transfixation-The 4R-4bar linkage concept
    • Carson WL, Duffi eld RC, Arendt M, et al. Internal forces and moments in transpedicular spine instrumentation. The effect of pedicle screw angle and transfi xation-the 4R-4bar linkage concept . Spine 1990; 15: 893-901. (Pubitemid 20358386)
    • (1990) Spine , vol.15 , Issue.9 , pp. 893-901
    • Carson, W.L.1    Duffield, R.C.2    Arendt, M.3    Ridgely, B.J.4    Gaines Jr., R.W.5
  • 43
    • 0025801025 scopus 로고
    • Triangulation of pedicular instrumentation. A biomechanical analysis
    • Ruland CM, McAfee PC, Warden KE, et al. Triangulation of pedicular instrumentation. A biomechanical analysis. Spine 1991; 16: S270-6.
    • (1991) Spine , vol.16
    • Ruland, C.M.1    McAfee, P.C.2    Warden, K.E.3
  • 44
    • 34250782220 scopus 로고    scopus 로고
    • Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: Comparison between conventional fluoroscopic and computer-assisted technique
    • DOI 10.1097/BRS.0b013e318068661e, PII 0000763220070615000014
    • Kotani Y, Abumi K, Ito M, et al. Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fl uoroscopic and computer-assisted technique. Spine 2007; 32: 1543-50. (Pubitemid 46956151)
    • (2007) Spine , vol.32 , Issue.14 , pp. 1543-1550
    • Kotani, Y.1    Abumi, K.2    Ito, M.3    Takahata, M.4    Sudo, H.5    Ohshima, S.6    Minami, A.7
  • 46
    • 76449111639 scopus 로고    scopus 로고
    • Accuracy of multilevel registration in image-guided pedicle screw insertion for adolescent idiopathic scoliosis
    • Takahashi J, Hirabayashi H, Hashidate H, et al. Accuracy of multilevel registration in image-guided pedicle screw insertion for adolescent idiopathic scoliosis. Spine 2010; 35: 347-52.
    • (2010) Spine , vol.35 , pp. 347-352
    • Takahashi, J.1    Hirabayashi, H.2    Hashidate, H.3
  • 47
    • 80052564997 scopus 로고    scopus 로고
    • Pedicle screw insertion accuracy with different assisted methods: A systematic review and meta-analysis of comparative studies
    • Tian NF, Huang QS, Zhou P, et al. Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies. Eur Spine J 2010; 20: 846-59.
    • (2010) Eur Spine J , vol.20 , pp. 846-859
    • Tian, N.F.1    Huang, Q.S.2    Zhou, P.3
  • 48
    • 77950548268 scopus 로고    scopus 로고
    • Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine
    • Rajan VV, Kamath V, Shetty AP, et al. Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine. Indian J Orthop 2010; 44: 163-8.
    • (2010) Indian J Orthop , vol.44 , pp. 163-168
    • Rajan, V.V.1    Kamath, V.2    Shetty, A.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.