메뉴 건너뛰기




Volumn 83, Issue 1, 2012, Pages

On-line use of three-dimensional marker trajectory estimation from cone-beam computed tomography projections for precise setup in radiotherapy for targets with respiratory motion

Author keywords

Cone beam computed tomography; Image guided radiotherapy; Liver metastases; Stereotactic body radiotherapy; Trajectory estimation

Indexed keywords

CONE-BEAM COMPUTED TOMOGRAPHY; IMAGE GUIDED RADIOTHERAPY; LIVER METASTASIS; STEREOTACTIC BODY RADIOTHERAPY; TRAJECTORY ESTIMATION;

EID: 84859848371     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2011.12.007     Document Type: Article
Times cited : (27)

References (17)
  • 1
    • 77950033834 scopus 로고    scopus 로고
    • Stereotactic body radiotherapy: A review
    • A. Martin, and A. Gaya Stereotactic body radiotherapy: A review Clin Oncol 22 2010 157 172
    • (2010) Clin Oncol , vol.22 , pp. 157-172
    • Martin, A.1    Gaya, A.2
  • 2
    • 70449721902 scopus 로고    scopus 로고
    • Stereotactic body radiation therapy for liver tumors: Impact of daily setup corrections and day-to-day anatomic variations on dose in target and organs at risk
    • A. Mendez Romero, R.T. Zinkstok, and W. Wunderink Stereotactic body radiation therapy for liver tumors: Impact of daily setup corrections and day-to-day anatomic variations on dose in target and organs at risk Int J Radiat Oncol Biol Phys 75 2009 1201 1208
    • (2009) Int J Radiat Oncol Biol Phys , vol.75 , pp. 1201-1208
    • Mendez Romero, A.1    Zinkstok, R.T.2    Wunderink, W.3
  • 3
    • 38349078986 scopus 로고    scopus 로고
    • A (short) history of image-guided radiotherapy
    • D. Verellen, M. De Ridder, and G. Storme A (short) history of image-guided radiotherapy Radiother Oncol 86 2008 4 13
    • (2008) Radiother Oncol , vol.86 , pp. 4-13
    • Verellen, D.1    De Ridder, M.2    Storme, G.3
  • 4
    • 33749422038 scopus 로고    scopus 로고
    • The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    • P.J. Keall, G.S. Mageras, and J.M. Balter The management of respiratory motion in radiation oncology report of AAPM Task Group 76 Med Phys 33 2006 3874 3900
    • (2006) Med Phys , vol.33 , pp. 3874-3900
    • Keall, P.J.1    Mageras, G.S.2    Balter, J.M.3
  • 5
    • 33748865018 scopus 로고    scopus 로고
    • Individualized image-guided iso-NTCP based liver cancer SBRT
    • L.A. Dawson, C. Eccles, and T. Craig Individualized image-guided iso-NTCP based liver cancer SBRT Acta Oncol 45 2006 856 864
    • (2006) Acta Oncol , vol.45 , pp. 856-864
    • Dawson, L.A.1    Eccles, C.2    Craig, T.3
  • 6
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image-guided radiation therapy
    • D.A. Jaffray, J.H. Siewerdsen, and J.W. Wong Flat-panel cone-beam computed tomography for image-guided radiation therapy Int J Radiat Oncol Biol Phys 53 2002 1337 1349
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1337-1349
    • Jaffray, D.A.1    Siewerdsen, J.H.2    Wong, J.W.3
  • 7
    • 67349247094 scopus 로고    scopus 로고
    • Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance
    • J.-J. Sonke, M. Rossi, and J. Wolthaus Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance Int J Radiat Oncol Biol Phys 74 2009 567 574
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , pp. 567-574
    • Sonke, J.-J.1    Rossi, M.2    Wolthaus, J.3
  • 8
    • 80052072847 scopus 로고    scopus 로고
    • Treatment precision of image-guided liver SBRT using implanted fiducial markers depends on marker-tumour distance
    • Y. Seppenwoolde, W. Wunderink, and S.R. Wunderink-van Veen Treatment precision of image-guided liver SBRT using implanted fiducial markers depends on marker-tumour distance Phys Med Biol 56 2011 5445 5468
    • (2011) Phys Med Biol , vol.56 , pp. 5445-5468
    • Seppenwoolde, Y.1    Wunderink, W.2    Wunderink-Van Veen, S.R.3
  • 9
    • 77249130305 scopus 로고    scopus 로고
    • Adaptive management of liver cancer radiotherapy
    • K.K. Brock, and L.A. Dawson Adaptive management of liver cancer radiotherapy Semin Radiat Oncol 20 2010 107 115
    • (2010) Semin Radiat Oncol , vol.20 , pp. 107-115
    • Brock, K.K.1    Dawson, L.A.2
  • 10
    • 77956574316 scopus 로고    scopus 로고
    • Inter- and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lung
    • E.S. Worm, A.T. Hansen, and J.B. Petersen Inter- and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lung Acta Oncol 49 2010 1177 1183
    • (2010) Acta Oncol , vol.49 , pp. 1177-1183
    • Worm, E.S.1    Hansen, A.T.2    Petersen, J.B.3
  • 11
    • 56349142559 scopus 로고    scopus 로고
    • A method to estimate mean position, motion magnitude, motion correlation, and trajectory of a tumor from cone-beam CT projections for image-guided radiotherapy
    • P.R. Poulsen, B. Cho, and P.J. Keall A method to estimate mean position, motion magnitude, motion correlation, and trajectory of a tumor from cone-beam CT projections for image-guided radiotherapy Int J Radiat Oncol Biol Phys 72 2008 1587 1596
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , pp. 1587-1596
    • Poulsen, P.R.1    Cho, B.2    Keall, P.J.3
  • 12
    • 51849109508 scopus 로고    scopus 로고
    • Three-dimensional prostate position estimation with a single x-ray imager utilizing the spatial probability density
    • P.R. Poulsen, B. Cho, and K. Langen Three-dimensional prostate position estimation with a single x-ray imager utilizing the spatial probability density Phys Med Biol 53 2008 4331 4353
    • (2008) Phys Med Biol , vol.53 , pp. 4331-4353
    • Poulsen, P.R.1    Cho, B.2    Langen, K.3
  • 13
    • 84905246508 scopus 로고    scopus 로고
    • Prediction of position estimation errors for 3D target trajectories estimated from cone-beam CT projections
    • J.-J. Sonke, Het Nederlands Kanker Instituut Amsterdam (CD-ROM only)
    • P.R. Poulsen, B. Cho, and P. Keall Prediction of position estimation errors for 3D target trajectories estimated from cone-beam CT projections J.-J. Sonke, Proceedings of the XVIth International Conference on the Use of Computers in Radiation Therapy 2010 Het Nederlands Kanker Instituut Amsterdam (CD-ROM only)
    • (2010) Proceedings of the XVIth International Conference on the Use of Computers in Radiation Therapy
    • Poulsen, P.R.1    Cho, B.2    Keall, P.3
  • 14
    • 35148830563 scopus 로고    scopus 로고
    • Development of the 4D Phantom for patient-specific, end-to-end radiation therapy QA
    • K. Malinowski, C. Noel, and W. Lu Development of the 4D Phantom for patient-specific, end-to-end radiation therapy QA Proc SPIE Int Soc Opt Eng 6510 2007 65100E-1-65100E-9
    • (2007) Proc SPIE Int Soc Opt Eng , vol.6510
    • Malinowski, K.1    Noel, C.2    Lu, W.3
  • 15
    • 77951877433 scopus 로고    scopus 로고
    • Dynamic multileaf collimator tracking of respiratory target motion based on a single kilovoltage imager during arc radiotherapy
    • P.R. Poulsen, B. Cho, and D. Ruan Dynamic multileaf collimator tracking of respiratory target motion based on a single kilovoltage imager during arc radiotherapy Int J Radiat Oncol Biol Phys 77 2010 600 607
    • (2010) Int J Radiat Oncol Biol Phys , vol.77 , pp. 600-607
    • Poulsen, P.R.1    Cho, B.2    Ruan, D.3
  • 16
    • 70249100691 scopus 로고    scopus 로고
    • Real-time prostate trajectory estimation with a single imager in arc radiotherapy: A simulation study
    • P.R. Poulsen, B. Cho, and P.J. Keall Real-time prostate trajectory estimation with a single imager in arc radiotherapy: A simulation study Phys Med Biol 54 2009 4019 4035
    • (2009) Phys Med Biol , vol.54 , pp. 4019-4035
    • Poulsen, P.R.1    Cho, B.2    Keall, P.J.3
  • 17
    • 78650072644 scopus 로고    scopus 로고
    • Using cone-beam CT projection images to estimate the average and complete trajectory of a fiducial marker moving with respiration
    • N. Becker, W.L. Smith, and S. Quirk Using cone-beam CT projection images to estimate the average and complete trajectory of a fiducial marker moving with respiration Phys Med Biol 55 2010 7439 7452
    • (2010) Phys Med Biol , vol.55 , pp. 7439-7452
    • Becker, N.1    Smith, W.L.2    Quirk, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.