메뉴 건너뛰기




Volumn 78, Issue 4, 2012, Pages 426-433

Use of pulse pressure variation to estimate changes in preload during experimental acute normovolemic hemodilution

Author keywords

Hemodilution; Hypertonic; Pressure; Saline solution

Indexed keywords

ACUTE NORMOVOLEMIC HEMODILUTION; ANIMAL EXPERIMENT; ARTICLE; ARTIFICIAL VENTILATION; BLOOD TRANSFUSION; CENTRAL VENOUS PRESSURE; CONTROLLED STUDY; CORRELATION ANALYSIS; HEART HEMODYNAMICS; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART PRELOAD; HEMATOCRIT; HEMODILUTION; NONHUMAN; PULMONARY ARTERY CATHETER; PULMONARY ARTERY OCCLUSION PRESSURE; PULSE PRESSURE; PULSE PRESSURE VARIATION; SWINE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; URINE VOLUME;

EID: 84859382447     PISSN: 03759393     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (27)
  • 1
    • 0037438587 scopus 로고    scopus 로고
    • Transfusion-related acute lung injury: Epidemiology and a prospective analysis of etiologic factors
    • Silliman CC, Boshkov LK, Mehdizadehkashi Z, Elzi DJ, Dickey WO, Podlosky L et al. Transfusion-related acute lung injury: epidemiology and a prospective analysis of etiologic factors. Blood 2003;101:454-62.
    • (2003) Blood , vol.101 , pp. 454-462
    • Silliman, C.C.1    Boshkov, L.K.2    Mehdizadehkashi, Z.3    Elzi, D.J.4    Dickey, W.O.5    Podlosky, L.6
  • 2
    • 0037868079 scopus 로고    scopus 로고
    • Blood transfusion, independent of shock severity, is associated with worse outcome in trauma
    • Malone DL, Dunne J, Tracy JK, Putnam AT, Scalea TM, Napolitano LM. Blood transfusion, independent of shock severity, is associated with worse outcome in trauma. J Trauma 2003;54:898-905.
    • (2003) J Trauma , vol.54 , pp. 898-905
    • Malone, D.L.1    Dunne, J.2    Tracy, J.K.3    Putnam, A.T.4    Scalea, T.M.5    Napolitano, L.M.6
  • 3
    • 53049093520 scopus 로고    scopus 로고
    • Efficacy of red blood cell transfusion in the critically ill: A systematic review of the literature
    • Marik PE, Corwin HL. Efficacy of red blood cell transfusion in the critically ill: a systematic review of the literature. Crit Care Med 2008;36:2667-74.
    • (2008) Crit Care Med , vol.36 , pp. 2667-2674
    • Marik, P.E.1    Corwin, H.L.2
  • 4
    • 77957903968 scopus 로고    scopus 로고
    • Transfusion requirements after cardiac surgery: The TRACS randomized controlled trial
    • Hajjar LA, Vincent JL, Galas FR, Nakamura RE, Silva CM, Santos MH et al. Transfusion requirements after cardiac surgery: the TRACS randomized controlled trial. JAMA 2010;304:1559-67.
    • (2010) JAMA , vol.304 , pp. 1559-1567
    • Hajjar, L.A.1    Vincent, J.L.2    Galas, F.R.3    Nakamura, R.E.4    Silva, C.M.5    Santos, M.H.6
  • 5
    • 33746892274 scopus 로고    scopus 로고
    • Practice guidelines for perioperative blood transfusion and adjuvant therapies: an updated report by the American Society of Anesthesiologists Task Force on Perioperative Blood Transfusion and Adjuvant Therapies
    • Practice guidelines for perioperative blood transfusion and adjuvant therapies: an updated report by the American Society of Anesthesiologists Task Force on Perioperative Blood Transfusion and Adjuvant Therapies. Anesthesiology 2006;105:198-208.
    • (2006) Anesthesiology , vol.105 , pp. 198-208
  • 6
    • 41049087999 scopus 로고    scopus 로고
    • Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: A comparison among LiDCO, transesophageal echochardiography, and pulmonary artery catheter
    • Belloni L, Pisano A, Natale A, Piccirillo MR, Piazza L, Ismeno G et al. Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal echochardiography, and pulmonary artery catheter. J Cardiothorac Vasc Anesth 2008;22:243-8.
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 243-248
    • Belloni, L.1    Pisano, A.2    Natale, A.3    Piccirillo, M.R.4    Piazza, L.5    Ismeno, G.6
  • 7
    • 41149154296 scopus 로고    scopus 로고
    • Venous function and central venous pressure: A physiologic story
    • Gelman S. Venous function and central venous pressure: a physiologic story. Anesthesiology 2008;108:735-48.
    • (2008) Anesthesiology , vol.108 , pp. 735-748
    • Gelman, S.1
  • 8
    • 73949102940 scopus 로고    scopus 로고
    • Stroke volume variation during acute normovolemic hemodilution
    • Kungys G, Rose DD, Fleming NW. Stroke volume variation during acute normovolemic hemodilution. Anesth Analg 2009;109:1823-30.
    • (2009) Anesth Analg , vol.109 , pp. 1823-1830
    • Kungys, G.1    Rose, D.D.2    Fleming, N.W.3
  • 9
    • 48749094759 scopus 로고    scopus 로고
    • Preload index and fluid responsiveness: Different aspects of the new concept of functional hemodynamic monitoring
    • Della Rocca G, Costa MG. Preload index and fluid responsiveness: different aspects of the new concept of functional hemodynamic monitoring. Minerva Anestesiol 2008;74:349-51.
    • (2008) Minerva Anestesiol , vol.74 , pp. 349-351
    • Della Rocca, G.1    Costa, M.G.2
  • 10
    • 42649125592 scopus 로고    scopus 로고
    • Functional hemodynamic monitoring and dynamic indices of fluid responsiveness
    • Cavallaro F, Sandroni C, Antonelli M. Functional hemodynamic monitoring and dynamic indices of fluid responsiveness. Minerva Anestesiol 2008;74:123-35.
    • (2008) Minerva Anestesiol , vol.74 , pp. 123-135
    • Cavallaro, F.1    Sandroni, C.2    Antonelli, M.3
  • 11
    • 23044461875 scopus 로고    scopus 로고
    • Changes in arterial pressure during mechanical ventilation
    • Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology 2005;103:419-28.
    • (2005) Anesthesiology , vol.103 , pp. 419-428
    • Michard, F.1
  • 12
    • 41349089777 scopus 로고    scopus 로고
    • Online monitoring of pulse pressure variation to guide fluid therapy after cardiac surgery
    • Auler JO Jr, Galas F, Hajjar L, Santos L, Carvalho T, Michard F. Online monitoring of pulse pressure variation to guide fluid therapy after cardiac surgery. Anesth Analg 2008;106:1201.
    • (2008) Anesth Analg , vol.106 , pp. 1201
    • Auler Jr, J.O.1    Galas, F.2    Hajjar, L.3    Santos, L.4    Carvalho, T.5    Michard, F.6
  • 13
    • 0033924592 scopus 로고    scopus 로고
    • Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
    • Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000;162:134-8.
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 134-138
    • Michard, F.1    Boussat, S.2    Chemla, D.3    Anguel, N.4    Mercat, A.5    Lecarpentier, Y.6
  • 14
    • 73949142368 scopus 로고    scopus 로고
    • A comparison between pulse pressure variation and right end diastolic volume index as guides to resuscitation in a model of hemorrhagic shock in pigs
    • de Oliveira MA, Otsuki DA, Noel-Morgan J, Leite VF, Fantoni DT, Auler JO Jr. A comparison between pulse pressure variation and right end diastolic volume index as guides to resuscitation in a model of hemorrhagic shock in pigs. J Trauma 2009;67:1225-32.
    • (2009) J Trauma , vol.67 , pp. 1225-1232
    • De Oliveira, M.A.1    Otsuki, D.A.2    Noel-Morgan, J.3    Leite, V.F.4    Fantoni, D.T.5    Auler Jr, J.O.6
  • 17
    • 34948909129 scopus 로고    scopus 로고
    • Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: A pilot randomized controlled trial
    • Lopes MR, Oliveira MA, Pereira VO, Lemos IP, Auler JO Jr, Michard F. Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care 2007;11:R100.
    • (2007) Crit Care , vol.11
    • Lopes, M.R.1    Oliveira, M.A.2    Pereira, V.O.3    Lemos, I.P.4    Auler, J.O.5    Michard, F.6
  • 18
    • 0018679823 scopus 로고
    • Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques
    • Folland ED, Parisi AF, Moynihan PF, Jones DR, Feldman CL, Tow DE. Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques. Circulation 1979;60:760-6.
    • (1979) Circulation , vol.60 , pp. 760-766
    • Folland, E.D.1    Parisi, A.F.2    Moynihan, P.F.3    Jones, D.R.4    Feldman, C.L.5    Tow, D.E.6
  • 19
    • 77954146232 scopus 로고    scopus 로고
    • Intravascular fluid and electrolyte physiology
    • In: Miller RD EL, Fleisher LA, Wiener-Kronish, JP, Young WL ed., 7th ed. Philadelphia, PA: Churchill Livingstone Elsevier
    • Kaye AD RJ. Intravascular fluid and electrolyte physiology. In: Miller RD EL, Fleisher LA, Wiener-Kronish, JP, Young WL ed. Miller ́s Anesthesia. 7th ed. Philadelphia, PA: Churchill Livingstone Elsevier; 2009. p. 1705-37.
    • (2009) Miller ́s Anesthesia , pp. 1705-1737
    • Kaye, A.D.R.J.1
  • 20
    • 33744775924 scopus 로고    scopus 로고
    • Comparison between intermit-tent and continuous measurement of cardiac output after acute normovolemic hemodilution in pigs
    • Otsuki DA, Cardieri FA, Schmidt AP, Brudniewski M, Fantoni DT, Auler JO Jr. Comparison between intermit-tent and continuous measurement of cardiac output after acute normovolemic hemodilution in pigs. Artif Organs 2006;30:458-66.
    • (2006) Artif Organs , vol.30 , pp. 458-466
    • Otsuki, D.A.1    Cardieri, F.A.2    Schmidt, A.P.3    Brudniewski, M.4    Fantoni, D.T.5    Auler Jr, J.O.6
  • 22
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence
    • Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002;121:2000-8.
    • (2002) Chest , vol.121 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 23
    • 34247158597 scopus 로고    scopus 로고
    • Pulse pressure respiratory variation as an early marker of cardiac output fall in experimental hemorrhagic shock
    • Westphal G, Garrido Adel P, de Almeida DP, Rocha e Silva M, Poli-de-Figueiredo LF. Pulse pressure respiratory variation as an early marker of cardiac output fall in experimental hemorrhagic shock. Artif Organs 2007;31:284-9.
    • (2007) Artif Organs , vol.31 , pp. 284-289
    • Westphal, G.1    Garrido, A.P.2    de Almeida, D.P.3    Rocha, E.S.M.4    Poli-De-Figueiredo, L.F.5
  • 24
    • 21644485259 scopus 로고    scopus 로고
    • Volumetric monitoring: Principles of application
    • Della Rocca G, Costa MG. Volumetric monitoring: principles of application. Minerva Anestesiol 2005;71:303-6.
    • (2005) Minerva Anestesiol , vol.71 , pp. 303-306
    • della Rocca, G.1    Costa, M.G.2
  • 25
    • 78650524800 scopus 로고    scopus 로고
    • Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure: An experimental study
    • Daudel F, Tuller D, Krahenbuhl S, Jakob SM, Takala J. Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure: an experimental study. Crit Care 2010;14:R122.
    • (2010) Crit Care , vol.14
    • Daudel, F.1    Tuller, D.2    Krahenbuhl, S.3    Jakob, S.M.4    Takala, J.5
  • 26
    • 64149105298 scopus 로고    scopus 로고
    • Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions
    • de Waal EE, Rex S, Kruitwagen CL, Kalkman CJ, Buhre WF. Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions. Crit Care Med 2009;37:510-5.
    • (2009) Crit Care Med , vol.37 , pp. 510-515
    • de Waal, E.E.1    Rex, S.2    Kruitwagen, C.L.3    Kalkman, C.J.4    Buhre, W.F.5
  • 27
    • 54549110342 scopus 로고    scopus 로고
    • Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation
    • Kim HK, Pinsky MR. Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation. Crit Care Med 2008;36:2858-62.
    • (2008) Crit Care Med , vol.36 , pp. 2858-2862
    • Kim, H.K.1    Pinsky, M.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.