메뉴 건너뛰기




Volumn 9, Issue 4, 2012, Pages 494-498

Cardiac device infections are associated with a significant mortality risk

Author keywords

Cardiac device infection; Cardiac resynchronization therapy; Implantable cardioverter defibrillator; Infection; Mortality

Indexed keywords

ADULT; AGED; ARTICLE; CARDIAC DEVICE INFECTION; CARDIAC PATIENT; CARDIAC RESYNCHRONIZATION THERAPY; CARDIAC RESYNCHRONIZATION THERAPY DEVICE; COAGULASE NEGATIVE STAPHYLOCOCCUS; COHORT ANALYSIS; CONTROLLED STUDY; DEFIBRILLATOR; DEVICE INFECTION; FEMALE; FOLLOW UP; HUMAN; INFECTION RISK; MAJOR CLINICAL STUDY; MALE; MORTALITY; PRIORITY JOURNAL; PROGNOSIS; PROPIONIBACTERIUM ACNES; RISK ASSESSMENT; STAPHYLOCOCCUS AUREUS;

EID: 84859317329     PISSN: 15475271     EISSN: 15563871     Source Type: Journal    
DOI: 10.1016/j.hrthm.2011.10.034     Document Type: Article
Times cited : (64)

References (24)
  • 5
    • 2442479695 scopus 로고    scopus 로고
    • Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure
    • M.R. Bristow, L.A. Saxon, J. Boehmer Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure N Engl J Med 350 2004 2140 2150
    • (2004) N Engl J Med , vol.350 , pp. 2140-2150
    • Bristow, M.R.1    Saxon, L.A.2    Boehmer, J.3
  • 8
    • 33746208049 scopus 로고    scopus 로고
    • Rising Rates of Cardiac Rhythm Management Device Infections in the United States: 1996 through 2003
    • DOI 10.1016/j.jacc.2006.05.016, PII S0735109706012496
    • A. Voigt, A. Shalaby, S. Saba Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003 J Am Coll Cardiol 48 2006 590 591 (Pubitemid 44093958)
    • (2006) Journal of the American College of Cardiology , vol.48 , Issue.3 , pp. 590-591
    • Voigt, A.1    Shalaby, A.2    Saba, S.3
  • 9
    • 77950508753 scopus 로고    scopus 로고
    • Continued rise in rates of cardiovascular implantable electronic device infections in the United States: Temporal trends and causative insights
    • A. Voigt, A. Shalaby, S. Saba Continued rise in rates of cardiovascular implantable electronic device infections in the United States: temporal trends and causative insights Pacing Clin Electrophysiol 33 2010 414 419
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 414-419
    • Voigt, A.1    Shalaby, A.2    Saba, S.3
  • 11
    • 65549099614 scopus 로고    scopus 로고
    • Risk factors and time delay associated with cardiac device infections: Leiden device registry
    • J.C. Lekkerkerker, N.C. van, S.A. Trines Risk factors and time delay associated with cardiac device infections: Leiden device registry Heart 95 2009 715 720
    • (2009) Heart , vol.95 , pp. 715-720
    • Lekkerkerker, J.C.1    Van, N.C.2    Trines, S.A.3
  • 12
    • 35348832856 scopus 로고    scopus 로고
    • How to treat and identify device infections
    • DOI 10.1016/j.hrthm.2007.08.007, PII S1547527107008077
    • B.L. Wilkoff How to treat and identify device infections Heart Rhythm 4 2007 1467 1470 (Pubitemid 47578533)
    • (2007) Heart Rhythm , vol.4 , Issue.11 , pp. 1467-1470
    • Wilkoff, B.L.1
  • 14
    • 0029935384 scopus 로고    scopus 로고
    • The additional hospital costs generated in the management of complications of pacemaker and defibrillator implantations
    • T.B. Ferguson Jr, C.L. Ferguson, K. Crites, P. Crimmins-Reda The additional hospital costs generated in the management of complications of pacemaker and defibrillator implantations J Thorac Cardiovasc Surg 111 1996 742 751
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 742-751
    • Ferguson, Jr.T.B.1    Ferguson, C.L.2    Crites, K.3    Crimmins-Reda, P.4
  • 15
    • 36048977608 scopus 로고    scopus 로고
    • Pacemaker Infections: A 10-Year Experience
    • DOI 10.1016/j.hlc.2007.02.097, PII S1443950607001552
    • A. Catanchin, C.J. Murdock, E. Athan Pacemaker infections: a 10-year experience Heart Lung Circ 16 2007 434 439 (Pubitemid 350091403)
    • (2007) Heart Lung and Circulation , vol.16 , Issue.6 , pp. 434-439
    • Catanchin, A.1    Murdock, C.J.2    Athan, E.3
  • 16
    • 55249106164 scopus 로고    scopus 로고
    • Longevity of implantable cardioverter-defibrillators: Implications for clinical practice and health care systems
    • M. Biffi, M. Ziacchi, M. Bertini Longevity of implantable cardioverter-defibrillators: implications for clinical practice and health care systems Europace 10 2008 1288 1295
    • (2008) Europace , vol.10 , pp. 1288-1295
    • Biffi, M.1    Ziacchi, M.2    Bertini, M.3
  • 17
    • 70549109870 scopus 로고    scopus 로고
    • Longevity of implantable cardioverter-defibrillators, influencing factors, and comparison to industry-projected longevity
    • B.A. Schaer, M.T. Koller, C. Sticherling, D. Altmann, L. Joerg, S. Osswald Longevity of implantable cardioverter-defibrillators, influencing factors, and comparison to industry-projected longevity Heart Rhythm 6 2009 1737 1743
    • (2009) Heart Rhythm , vol.6 , pp. 1737-1743
    • Schaer, B.A.1    Koller, M.T.2    Sticherling, C.3    Altmann, D.4    Joerg, L.5    Osswald, S.6
  • 18
    • 77955320887 scopus 로고    scopus 로고
    • Recurrent implantable cardioverter-defibrillator replacement is associated with an increasing risk of pocket-related complications
    • C.J. Borleffs, J. Thijssen, M.K. de Bie Recurrent implantable cardioverter-defibrillator replacement is associated with an increasing risk of pocket-related complications Pacing Clin Electrophysiol 33 2010 1013 1019
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 1013-1019
    • Borleffs, C.J.1    Thijssen, J.2    De Bie, M.K.3
  • 19
    • 77956886709 scopus 로고    scopus 로고
    • Cardiac implantable electronic device infections: Presentation, management, and patient outcomes
    • K.G. Tarakji, E.J. Chan, D.J. Cantillon Cardiac implantable electronic device infections: presentation, management, and patient outcomes Heart Rhythm 7 2010 1043 1047
    • (2010) Heart Rhythm , vol.7 , pp. 1043-1047
    • Tarakji, K.G.1    Chan, E.J.2    Cantillon, D.J.3
  • 20
    • 76649138577 scopus 로고    scopus 로고
    • Update on cardiovascular implantable electronic device infections and their management: A scientific statement from the American Heart Association
    • L.M. Baddour, A.E. Epstein, C.C. Erickson Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association Circulation 121 2010 458 477
    • (2010) Circulation , vol.121 , pp. 458-477
    • Baddour, L.M.1    Epstein, A.E.2    Erickson, C.C.3
  • 21
    • 77952217479 scopus 로고    scopus 로고
    • Dual antiplatelet therapy and heparin "bridging" significantly increase the risk of bleeding complications after pacemaker or implantable cardioverter-defibrillator device implantation
    • C. Tompkins, A. Cheng, D. Dalal Dual antiplatelet therapy and heparin "bridging" significantly increase the risk of bleeding complications after pacemaker or implantable cardioverter-defibrillator device implantation J Am Coll Cardiol 55 2010 2376 2382
    • (2010) J Am Coll Cardiol , vol.55 , pp. 2376-2382
    • Tompkins, C.1    Cheng, A.2    Dalal, D.3
  • 22
    • 79952174827 scopus 로고    scopus 로고
    • Morbidity associated with three different antiplatelet regimens in patients undergoing implantation of cardiac rhythm management devices
    • O. Cano, J. Osca, M.J. Sancho-Tello, J. Olague, J.E. Castro, A. Salvador Morbidity associated with three different antiplatelet regimens in patients undergoing implantation of cardiac rhythm management devices Europace 13 2011 395 401
    • (2011) Europace , vol.13 , pp. 395-401
    • Cano, O.1    Osca, J.2    Sancho-Tello, M.J.3    Olague, J.4    Castro, J.E.5    Salvador, A.6
  • 24
    • 67650669013 scopus 로고    scopus 로고
    • In vivo model of human pathogen infection and demonstration of efficacy by an antimicrobial pouch for pacing devices
    • L.K. Hansen, M. Brown, D. Johnson, D.F. Palme Ii, C. Love, R. Darouiche In vivo model of human pathogen infection and demonstration of efficacy by an antimicrobial pouch for pacing devices Pacing Clin Electrophysiol 32 2009 898 907
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 898-907
    • Hansen, L.K.1    Brown, M.2    Johnson, D.3    Palme Ii, D.F.4    Love, C.5    Darouiche, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.