-
1
-
-
0028303128
-
Clinical experience with the 3M microvascular coupling anastomotic device in 100 free-tissue transfers
-
DOI 10.1097/00006534-199406000-00022
-
Ahn CY, Shaw WW, Berns S, Markowitz BL. Clinical experience with the 3M microvascular coupling anastomotic device in 100 free-tissue transfers. Plast Reconstr Surg: 1994; 93 7 1481 1484 (Pubitemid 24200750)
-
(1994)
Plastic and Reconstructive Surgery
, vol.93
, Issue.7
, pp. 1481-1484
-
-
Ahn, C.Y.1
Shaw, W.W.2
Berns, S.3
Markowitz, B.L.4
-
2
-
-
33645381055
-
Routine use of microvascular coupling device for arterial anastomosis in breast reconstruction
-
Spector JA, Draper LB, Levine JP, Ahn CY. Routine use of microvascular coupling device for arterial anastomosis in breast reconstruction. Ann Plast Surg: 2006; 56 4 365 368
-
(2006)
Ann Plast Surg
, vol.56
, Issue.4
, pp. 365-368
-
-
Spector, J.A.1
Draper, L.B.2
Levine, J.P.3
Ahn, C.Y.4
-
3
-
-
77749328262
-
1000 consecutive venous anastomoses using the microvascular anastomotic coupler in breast reconstruction
-
Jandali S, Wu LC, Vega SJ, Kovach SJ, Serletti JM. 1000 consecutive venous anastomoses using the microvascular anastomotic coupler in breast reconstruction. Plast Reconstr Surg: 2010; 125 3 792 798
-
(2010)
Plast Reconstr Surg
, vol.125
, Issue.3
, pp. 792-798
-
-
Jandali, S.1
Wu, L.C.2
Vega, S.J.3
Kovach, S.J.4
Serletti, J.M.5
-
4
-
-
34249819981
-
Free flap reexploration: Indications, treatment, and outcomes in 1193 free flaps
-
DOI 10.1097/01.prs.0000260598.24376.e1, PII 0000653420070600000018
-
Bui DT, Cordeiro PG, Hu QY, Disa JJ, Pusic A, Mehrara BJ. Free flap reexploration: indications, treatment, and outcomes in 1193 free flaps. Plast Reconstr Surg: 2007; 119 7 2092 2100 (Pubitemid 46847103)
-
(2007)
Plastic and Reconstructive Surgery
, vol.119
, Issue.7
, pp. 2092-2100
-
-
Bui, D.T.1
Cordeiro, P.G.2
Hu, Q.-Y.3
Disa, J.J.4
Pusic, A.5
Mehrara, B.J.6
-
5
-
-
0032978923
-
Efficacy of conventional monitoring techniques in free tissue transfer: An 11-year experience in 750 consecutive cases
-
DOI 10.1097/00006534-199907000-00013
-
Disa JJ, Cordeiro PG, Hidalgo DA. Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases. Plast Reconstr Surg: 1999; 104 1 97 101 (Pubitemid 29283196)
-
(1999)
Plastic and Reconstructive Surgery
, vol.104
, Issue.1
, pp. 97-101
-
-
Disa, J.J.1
Cordeiro, P.G.2
Hidalgo, D.A.3
-
6
-
-
78649232795
-
Modern adjuncts and technologies in microsurgery: An historical and evidence-based review
-
Pratt GF, Rozen WM, Chubb D., et al. Modern adjuncts and technologies in microsurgery: an historical and evidence-based review. Microsurgery: 2010; 30 8 657 666
-
(2010)
Microsurgery
, vol.30
, Issue.8
, pp. 657-666
-
-
Pratt, G.F.1
Rozen, W.M.2
Chubb, D.3
-
7
-
-
36649008539
-
Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy
-
DOI 10.1016/j.bjps.2007.04.003, PII S1748681507002471
-
Repez A, Oroszy D, Arnez ZM. Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy. J Plast Reconstr Aesthet Surg: 2008; 61 1 71 77 (Pubitemid 350199113)
-
(2008)
Journal of Plastic, Reconstructive and Aesthetic Surgery
, vol.61
, Issue.1
, pp. 71-77
-
-
Repez, A.1
Oroszy, D.2
Arnez, Z.M.3
-
8
-
-
0032053518
-
Assessment of tissue viability using near-infrared spectroscopy
-
DOI 10.1054/bjps.1997.0088
-
Stranc MF, Sowa MG, Abdulrauf B, Mantsch HH. Assessment of tissue viability using near-infrared spectroscopy. Br J Plast Surg: 1998; 51 3 210 217 (Pubitemid 28200957)
-
(1998)
British Journal of Plastic Surgery
, vol.51
, Issue.3
, pp. 210-217
-
-
Stranc, M.F.1
Sowa, M.G.2
Abdulrauf, B.3
Mantsch, H.H.4
-
9
-
-
0032054550
-
The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery
-
DOI 10.1054/bjps.1997.0145
-
Thorniley MS, Sinclair JS, Barnett NJ, Shurey CB, Green CJ. The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery. Br J Plast Surg: 1998; 51 3 218 226 (Pubitemid 28200958)
-
(1998)
British Journal of Plastic Surgery
, vol.51
, Issue.3
, pp. 218-226
-
-
Thorniley, M.S.1
Sinclair, S.J.2
Barnett, N.J.3
Shurey, C.B.4
Green, C.J.5
-
10
-
-
0029856750
-
Oxygenation and blood volume changes in flaps according to near-infrared spectrophotometry
-
Hayden RE, Tavill MA, Nioka S, Kitai T, Chance B. Oxygenation and blood volume changes in flaps according to near-infrared spectrophotometry. Arch Otolaryngol Head Neck Surg: 1996; 122 12 1347 1351 (Pubitemid 26408918)
-
(1996)
Archives of Otolaryngology - Head and Neck Surgery
, vol.122
, Issue.12
, pp. 1347-1351
-
-
Hayden, R.E.1
Tavill, M.A.2
Nioka, S.3
Kitai, T.4
Chance, B.5
-
11
-
-
0028850787
-
Near infra-red spectroscopy: A non-invasive monitor of perfusion and oxygenation within the microcirculation of limbs and flaps
-
Irwin MS, Thorniley MS, Dor CJ, Green CJ. Near infra-red spectroscopy: a non-invasive monitor of perfusion and oxygenation within the microcirculation of limbs and flaps. Br J Plast Surg: 1995; 48 1 14 22
-
(1995)
Br J Plast Surg
, vol.48
, Issue.1
, pp. 14-22
-
-
Irwin, M.S.1
Thorniley, M.S.2
Dor, C.J.3
Green, C.J.4
-
12
-
-
38949168887
-
Evaluation of near infrared spectroscopy in monitoring postoperative regional tissue oxygen saturation for fibular flaps
-
DOI 10.1016/j.bjps.2007.10.047, PII S1748681507005645
-
Cai ZG, Zhang J, Zhang JG., et al. Evaluation of near infrared spectroscopy in monitoring postoperative regional tissue oxygen saturation for fibular flaps. J Plast Reconstr Aesthet Surg: 2008; 61 3 289 296 (Pubitemid 351215146)
-
(2008)
Journal of Plastic, Reconstructive and Aesthetic Surgery
, vol.61
, Issue.3
, pp. 289-296
-
-
Cai, Z.-g.1
Zhang, J.2
Zhang, J.-g.3
Zhao, F.-y.4
Yu, G.-y.5
Li, Y.6
Ding, H.-s.7
-
13
-
-
43149111830
-
Near-infrared spectroscopy measures tissue oxygenation in free flaps for breast reconstruction
-
DOI 10.1097/PRS.0b013e31816b11e5, PII 0000653420080500000088
-
Colwell AS, Wright L, Karanas Y. Near-infrared spectroscopy measures tissue oxygenation in free flaps for breast reconstruction. Plast Reconstr Surg: 2008; 121 5 344e 345e (Pubitemid 351642784)
-
(2008)
Plastic and Reconstructive Surgery
, vol.121
, Issue.5
-
-
Colwell, A.S.1
Wright, L.2
Karanas, Y.3
-
14
-
-
34249932327
-
Non-invasive tissue oximetry for flap monitoring: An initial study
-
DOI 10.1055/s-2007-974655
-
Keller A. Noninvasive tissue oximetry for flap monitoring: an initial study. J Reconstr Microsurg: 2007; 23 4 189 197 (Pubitemid 46878832)
-
(2007)
Journal of Reconstructive Microsurgery
, vol.23
, Issue.4
, pp. 189-197
-
-
Keller, A.1
-
15
-
-
67449168310
-
A new diagnostic algorithm for early prediction of vascular compromise in 208 microsurgical flaps using tissue oxygen saturation measurements
-
Keller A. A new diagnostic algorithm for early prediction of vascular compromise in 208 microsurgical flaps using tissue oxygen saturation measurements. Ann Plast Surg: 2009; 62 5 538 543
-
(2009)
Ann Plast Surg
, vol.62
, Issue.5
, pp. 538-543
-
-
Keller, A.1
-
16
-
-
79952457212
-
Application of near infrared spectroscopy in monitoring blood oxygen saturation of fibula flaps
-
Shan XF, Cai ZG, Yu GY, Li Y, Ding HS. [Application of near infrared spectroscopy in monitoring blood oxygen saturation of fibula flaps]. Zhonghua Kou Qiang Yi Xue Za Zhi: 2008; 43 7 398 401
-
(2008)
Zhonghua Kou Qiang Yi Xue Za Zhi
, vol.43
, Issue.7
, pp. 398-401
-
-
Shan, X.F.1
Cai, Z.G.2
Yu, G.Y.3
Li, Y.4
Ding, H.S.5
-
17
-
-
0037333610
-
Tissue oxygenation and perfusion in inferior pedicle reduction mammaplasty by near-infrared reflection spectroscopy and color-coded duplex sonography
-
DOI 10.1097/01.PRS.0000046615.36917.3E
-
Scheufler O, Andresen R. Tissue oxygenation and perfusion in inferior pedicle reduction mammaplasty by near-infrared reflection spectroscopy and color-coded duplex sonography. Plast Reconstr Surg: 2003; 111 3 1131 1146 (Pubitemid 36297410)
-
(2003)
Plastic and Reconstructive Surgery
, vol.111
, Issue.3
, pp. 1131-1146
-
-
Scheufler, O.1
Andresen, R.2
-
18
-
-
4444323360
-
Investigation of TRAM flap oxygenation and perfusion by near-infrared reflection spectroscopy and color-coded duplex sonography
-
DOI 10.1097/01.PRS.0000095940.96294.A5
-
Scheufler O, Exner K, Andresen R. Investigation of TRAM flap oxygenation and perfusion by near-infrared reflection spectroscopy and color-coded duplex sonography. Plast Reconstr Surg: 2004; 113 1 141 152, discussion 153-155 (Pubitemid 39202020)
-
(2004)
Plastic and Reconstructive Surgery
, vol.113
, Issue.1
, pp. 141-152
-
-
Scheufler, O.1
Exner, K.2
Andresen, R.3
-
20
-
-
0026023960
-
Pulse oximetry in postoperative monitoring of free muscle flaps
-
Lindsey LA, Watson JD, Quaba AA. Pulse oximetry in postoperative monitoring of free muscle flaps. Br J Plast Surg: 1991; 44 1 27 29
-
(1991)
Br J Plast Surg
, vol.44
, Issue.1
, pp. 27-29
-
-
Lindsey, L.A.1
Watson, J.D.2
Quaba, A.A.3
-
21
-
-
0018652080
-
2 monitoring of flap circulation following surgery
-
Achauer BM, Black KS, Beran AV, Huxtable RF. Transcutaneous PO2 monitoring of flap circulation following surgery. Birth Defects Orig Artic Ser: 1979; 15 4 517 522 (Pubitemid 10163356)
-
(1979)
Birth Defects: Original Article Series
, vol.15
, Issue.4
, pp. 517-522
-
-
Achauer, B.M.1
Black, K.S.2
Beran, A.V.3
Huxtable, R.F.4
-
22
-
-
0344074449
-
Spectral analysis of photoplethysmograms from radial forearm free flaps
-
DOI 10.1097/00005537-199809000-00013
-
Stack BC Jr, Futran ND, Shohet MJ, Scharf JE. Spectral analysis of photoplethysmograms from radial forearm free flaps. Laryngoscope: 1998; 108 9 1329 1333 (Pubitemid 28411360)
-
(1998)
Laryngoscope
, vol.108
, Issue.9
, pp. 1329-1333
-
-
Stack Jr., B.C.1
Futran, N.D.2
Shohet, M.J.3
Scharf, J.E.4
-
23
-
-
0042627799
-
Initial experience with personal digital assistant-based reflectance photoplethysmograph for free tissue transfer monitoring
-
DOI 10.1097/01.SAP.0000060183.42582.C0
-
Stack BC Jr, Futran ND, Zang B, Scharf JE. Initial experience with personal digital assistant-based reflectance photoplethysmograph for free tissue transfer monitoring. Ann Plast Surg: 2003; 51 2 136 140 (Pubitemid 36944480)
-
(2003)
Annals of Plastic Surgery
, vol.51
, Issue.2
, pp. 136-140
-
-
Stack Jr., B.C.1
Futran, N.D.2
Zang, B.3
Scharf, J.E.4
-
24
-
-
58149166619
-
Free flap monitoring using skin temperature strip indicators: Adjunct to clinical examination
-
Chiu ES, Altman A, Allen RJ Jr, Allen RJ Sr. Free flap monitoring using skin temperature strip indicators: adjunct to clinical examination. Plast Reconstr Surg: 2008; 122 5 144e 145e
-
(2008)
Plast Reconstr Surg
, vol.122
, Issue.5
-
-
Chiu, E.S.1
Altman, A.2
Allen Jr., R.J.3
Allen Sr., R.J.4
-
25
-
-
0029799679
-
Evaluation of pedicled skin flap viability by pH, temperature and fluorescein: An experimental study
-
Issing WJ, Naumann C. Evaluation of pedicled skin flap viability by pH, temperature and fluorescein: an experimental study. J Craniomaxillofac Surg: 1996; 24 5 305 309 (Pubitemid 26390518)
-
(1996)
Journal of Cranio-Maxillo-Facial Surgery
, vol.24
, Issue.5
, pp. 305-309
-
-
Issing, W.J.1
Naumann, C.2
-
28
-
-
34848881390
-
Microdialysis: Use in the assessment of a buried bone-only fibular free flap
-
DOI 10.1097/01.prs.0000279555.75241.4c, PII 0000653420071000000034
-
Mourouzis C, Anand R, Bowden JR, Brennan PA. Microdialysis: use in the assessment of a buried bone-only fibular free flap. Plast Reconstr Surg: 2007; 120 5 1363 1366 (Pubitemid 47493964)
-
(2007)
Plastic and Reconstructive Surgery
, vol.120
, Issue.5
, pp. 1363-1366
-
-
Mourouzis, C.1
Anand, R.2
Bowden, J.R.3
Brennan, P.A.4
-
29
-
-
33746824687
-
Monitoring buried free flaps: Limitations of the implantable Doppler and use of color duplex sonography as a confirmatory test
-
DOI 10.1097/01.prs.0000221113.78244.8c, PII 0000653420060700000016
-
Rosenberg JJ, Fornage BD, Chevray PM. Monitoring buried free flaps: limitations of the implantable Doppler and use of color duplex sonography as a confirmatory test. Plast Reconstr Surg: 2006; 118 1 109 113, discussion 114-115 (Pubitemid 44324173)
-
(2006)
Plastic and Reconstructive Surgery
, vol.118
, Issue.1
, pp. 109-113
-
-
Rosenberg, J.J.1
Fornage, B.D.2
Chevray, P.M.3
-
30
-
-
34249894973
-
Value of high resolution ultrasound and contrast enhanced US pulse inversion imaging for the evaluation of the vascular integrity of free-flap grafts
-
Prantl L, Pfister K, Kubale R., et al. Value of high resolution ultrasound and contrast enhanced US pulse inversion imaging for the evaluation of the vascular integrity of free-flap grafts. Clin Hemorheol Microcirc: 2007; 36 3 203 216 (Pubitemid 46866634)
-
(2007)
Clinical Hemorheology and Microcirculation
, vol.36
, Issue.3
, pp. 203-216
-
-
Prantl, L.1
Pfister, K.2
Kubale, R.3
Schmitt, St.4
Stockhammer, V.5
Jung, W.6
Zorger, N.7
Herold, T.8
Nerlich, M.9
Stehr, A.10
Jung, E.M.11
-
31
-
-
51349154543
-
A simple method of implantable Doppler cuff attachment: Experience in 150 DIEP breast reconstructions
-
Whitaker IS, Smit JM, Acosta R. A simple method of implantable Doppler cuff attachment: experience in 150 DIEP breast reconstructions. J Plast Reconstr Aesthet Surg: 2008; 61 10 1251 1252
-
(2008)
J Plast Reconstr Aesthet Surg
, vol.61
, Issue.10
, pp. 1251-1252
-
-
Whitaker, I.S.1
Smit, J.M.2
Acosta, R.3
-
32
-
-
0028140059
-
Implantable venous doppler microvascular monitoring: Laboratory investigation and clinical results
-
Swartz WM, Izquierdo R, Miller MJ. Implantable venous Doppler microvascular monitoring: laboratory investigation and clinical results. Plast Reconstr Surg: 1994; 93 1 152 163 (Pubitemid 24015175)
-
(1994)
Plastic and Reconstructive Surgery
, vol.93
, Issue.1
, pp. 152-163
-
-
Swartz, W.M.1
Izquierdo, R.2
Miller, M.J.3
-
33
-
-
0033971378
-
Monitoring free flaps using the laser Doppler flowmeter: Five-year experience
-
Yuen JC, Feng Z. Monitoring free flaps using the laser Doppler flowmeter: five-year experience. Plast Reconstr Surg: 2000; 105 1 55 61 (Pubitemid 30027026)
-
(2000)
Plastic and Reconstructive Surgery
, vol.105
, Issue.1
, pp. 55-61
-
-
Yuen, J.C.1
Feng, Z.2
-
35
-
-
0026018069
-
Impedance plethysmography: A new method for continuous muscle perfusion monitoring
-
Concannon MJ, Stewart DH, Welsh CF, Puckett CL. Impedance plethysmography: a new method for continuous muscle perfusion monitoring. Plast Reconstr Surg: 1991; 88 2 292 298
-
(1991)
Plast Reconstr Surg
, vol.88
, Issue.2
, pp. 292-298
-
-
Concannon, M.J.1
Stewart, D.H.2
Welsh, C.F.3
Puckett, C.L.4
-
36
-
-
0024352276
-
Impedance monitoring for subcutaneous free flap transfers
-
DOI 10.1016/0007-1226(89)90154-9
-
Harrison DH, Mott G. Impedance monitoring for subcutaneous free flap transfers. Br J Plast Surg: 1989; 42 3 318 323 (Pubitemid 19136764)
-
(1989)
British Journal of Plastic Surgery
, vol.42
, Issue.3
, pp. 318-323
-
-
Harrison, D.H.1
Mott, G.2
-
37
-
-
72649107347
-
Monitoring of microcirculation in free transferred musculocutaneous latissimus dorsi flaps by confocal laser scanning microscopya promising non-invasive methodical approach
-
Altintas MA, Altintas AA, Guggenheim M, Knobloch K, Niederbichler AD, Vogt PM. Monitoring of microcirculation in free transferred musculocutaneous latissimus dorsi flaps by confocal laser scanning microscopya promising non-invasive methodical approach. J Plast Reconstr Aesthet Surg: 2010; 63 1 111 117
-
(2010)
J Plast Reconstr Aesthet Surg
, vol.63
, Issue.1
, pp. 111-117
-
-
Altintas, M.A.1
Altintas, A.A.2
Guggenheim, M.3
Knobloch, K.4
Niederbichler, A.D.5
Vogt, P.M.6
-
38
-
-
33645240821
-
99mTc sestamibi scintigraphy
-
DOI 10.1097/00006231-200601000-00013, PII 0000623120060100000013
-
Top H, Sarikaya A, Aygit AC, Benlier E, Kiyak M. Review of monitoring free muscle flap transfers in reconstructive surgery: role of 99mTc sestamibi scintigraphy. Nucl Med Commun: 2006; 27 1 91 98 (Pubitemid 44391844)
-
(2006)
Nuclear Medicine Communications
, vol.27
, Issue.1
, pp. 91-98
-
-
Top, H.1
Sarikaya, A.2
Aygit, A.C.3
Benlier, E.4
Kiyak, M.5
-
39
-
-
0032829480
-
Technetium 99m sestamibi scintigraphy for noninvasive assessment of muscle flap viability [4]
-
Aygit AC, Sarikaya A. Technetium 99m sestamibi scintigraphy for noninvasive assessment of muscle flap viability. Ann Plast Surg: 1999; 43 3 338 340 (Pubitemid 29421183)
-
(1999)
Annals of Plastic Surgery
, vol.43
, Issue.3
, pp. 338-340
-
-
Aygit, A.C.1
Sarikaya, A.2
-
40
-
-
0020842714
-
Tissue pH monitoring in microsurgery: A preliminary evaluation of continuous tissue pH monitoring as an indicator of perfusion disturbances in microvascular free flaps
-
Raskin DJ, Erk Y, Spira M, Melissinos EG. Tissue pH monitoring in microsurgery: a preliminary evaluation of continuous tissue pH monitoring as an indicator of perfusion disturbances in microvascular free flaps. Ann Plast Surg: 1983; 11 4 331 339
-
(1983)
Ann Plast Surg
, vol.11
, Issue.4
, pp. 331-339
-
-
Raskin, D.J.1
Erk, Y.2
Spira, M.3
Melissinos, E.G.4
-
41
-
-
0021960555
-
Continuous subcutaneous tissue pH measurement as a monitor of blood flow in skin flaps: An experimental study
-
DOI 10.1016/0007-1226(85)90084-0
-
Dickson MG, Sharpe DT. Continuous subcutaneous tissue pH measurement as a monitor of blood flow in skin flaps: an experimental study. Br J Plast Surg: 1985; 38 1 39 42 (Pubitemid 15105391)
-
(1985)
British Journal of Plastic Surgery
, vol.38
, Issue.1
, pp. 39-42
-
-
Dickson, M.G.1
Sharpe, D.T.2
-
42
-
-
0031014893
-
Postoperative blood flow monitoring after free-tissue transfer by means of the hydrogen clearance technique
-
DOI 10.1097/00006534-199702000-00027
-
Machens HG, Mailaender P, Reimer R, Pallua N, Lei Y, Berger A. Postoperative blood flow monitoring after free-tissue transfer by means of the hydrogen clearance technique. Plast Reconstr Surg: 1997; 99 2 493 505 (Pubitemid 27068561)
-
(1997)
Plastic and Reconstructive Surgery
, vol.99
, Issue.2
, pp. 493-505
-
-
Machens, H.-G.1
Mailaender, P.2
Reimer, R.3
Fallua, N.4
Lei, Y.5
Berger, A.6
-
43
-
-
0026042040
-
Hydrogen clearance: Assessment of technique for measurement of skin-flap blood flow in pigs
-
Thomson JG, Kerrigan CL. Hydrogen clearance: assessment of technique for measurement of skin-flap blood flow in pigs. Plast Reconstr Surg: 1991; 88 4 657 663
-
(1991)
Plast Reconstr Surg
, vol.88
, Issue.4
, pp. 657-663
-
-
Thomson, J.G.1
Kerrigan, C.L.2
-
44
-
-
0025305819
-
External monitoring of vascularized jejunum transfers using laser Doppler flowmetry
-
Hallock GG, Koch TJ. External monitoring of vascularized jejunum transfers using laser Doppler flowmetry. Ann Plast Surg: 1990; 24 3 213 215 (Pubitemid 20140717)
-
(1990)
Annals of Plastic Surgery
, vol.24
, Issue.3
, pp. 213-215
-
-
Hallock, G.G.1
Koch, T.J.2
-
45
-
-
30944436447
-
Free flap monitoring using simultaneous non-invasive laser Doppler flowmetry and tissue spectrophotometry
-
DOI 10.1016/j.jcms.2005.07.010, PII S1010518205001174
-
Hölzle F, Loeffelbein DJ, Nolte D, Wolff K-D. Free flap monitoring using simultaneous non-invasive laser Doppler flowmetry and tissue spectrophotometry. J Craniomaxillofac Surg: 2006; 34 1 25 33 (Pubitemid 43115677)
-
(2006)
Journal of Cranio-Maxillofacial Surgery
, vol.34
, Issue.1
, pp. 25-33
-
-
Holzle, F.1
Loeffelbein, D.J.2
Nolte, D.3
Wolff, K.-D.4
-
46
-
-
0038753805
-
Postoperative monitoring of microvascular tissue transfers: Current practice in the United Kingdom and Ireland [16]
-
DOI 10.1097/01.PRS.0000057070.74385.AF
-
Whitaker IS, Oliver DW, Ganchi PA. Postoperative monitoring of microvascular tissue transfers: current practice in the United kingdom and Ireland. Plast Reconstr Surg: 2003; 111 6 2118 2119 (Pubitemid 36532391)
-
(2003)
Plastic and Reconstructive Surgery
, vol.111
, Issue.6
, pp. 2118-2119
-
-
Whitaker, I.S.1
Oliver, D.W.2
Ganchi, P.A.3
-
47
-
-
33845298236
-
Variations in the postoperative management of free tissue transfers to the head and neck in the United Kingdom
-
DOI 10.1016/j.bjoms.2005.11.021, PII S026643560500361X
-
Whitaker IS, Gulati V, Ross GL, Menon A, Ong TK. Variations in the postoperative management of free tissue transfers to the head and neck in the United Kingdom. Br J Oral Maxillofac Surg: 2007; 45 1 16 18 (Pubitemid 44873835)
-
(2007)
British Journal of Oral and Maxillofacial Surgery
, vol.45
, Issue.1
, pp. 16-18
-
-
Whitaker, I.S.1
Gulati, V.2
Ross, G.L.3
Menon, A.4
Ong, T.K.5
-
48
-
-
35848938517
-
Early reintervention of compromised free flaps improves success rate
-
DOI 10.1002/micr.20412
-
Smit JM, Acosta R, Zeebregts CJ, Liss AG, Anniko M, Hartman EHM. Early reintervention of compromised free flaps improves success rate. Microsurgery: 2007; 27 7 612 616 (Pubitemid 350060149)
-
(2007)
Microsurgery
, vol.27
, Issue.7
, pp. 612-616
-
-
Smit, J.M.1
Acosta, R.2
Zeebregts, C.J.3
Liss, A.G.4
Anniko, M.5
Hartman, E.H.M.6
-
49
-
-
52049084866
-
Timing of presentation of the first signs of vascular compromise dictates the salvage outcome of free flap transfers
-
Smit JM, Zeebregts CJ, Acosta R. Timing of presentation of the first signs of vascular compromise dictates the salvage outcome of free flap transfers. Plast Reconstr Surg: 2008; 122 3 991 992
-
(2008)
Plast Reconstr Surg
, vol.122
, Issue.3
, pp. 991-992
-
-
Smit, J.M.1
Zeebregts, C.J.2
Acosta, R.3
-
50
-
-
34547700418
-
A critical review of perioperative complications in 175 free deep inferior epigastric perforator flap breast reconstructions
-
DOI 10.1097/01.sap.0000253326.85829.45, PII 0000063720070800000005
-
Hofer SO, Damen TH, Mureau MA, Rakhorst HA, Roche NA. A critical review of perioperative complications in 175 free deep inferior epigastric perforator flap breast reconstructions. Ann Plast Surg: 2007; 59 2 137 142 (Pubitemid 47220415)
-
(2007)
Annals of Plastic Surgery
, vol.59
, Issue.2
, pp. 137-142
-
-
Hofer, S.O.P.1
Damen, T.H.C.2
Mureau, M.A.M.3
Rakhorst, H.A.4
Roche, N.A.5
|