-
1
-
-
0029552793
-
Free flap monitoring: A review of current practice
-
DOI 10.1002/micr.1920161103
-
Hirigoyen MB, Urken ML, Weinberg H, et al. Free flap monitoring: a review of current practice. Microsurgery. 1995;16:723-727. (Pubitemid 26137902)
-
(1995)
Microsurgery
, vol.16
, Issue.11
, pp. 723-727
-
-
Hirigoyen, M.B.1
Urken, M.L.2
Weinberg, H.3
Grotting, J.C.4
-
2
-
-
0031870257
-
Reduced cost of extremity free flap monitoring
-
DOI 10.1097/00000637-199807000-00007
-
Yuen JC, Feng Z. Reduced cost of extremity free flap monitoring. Ann Plast Surg. 1998;41:36-40. (Pubitemid 28317777)
-
(1998)
Annals of Plastic Surgery
, vol.41
, Issue.1
, pp. 36-40
-
-
Yuen, J.C.1
Feng, Z.2
-
3
-
-
0026730033
-
Avoiding free flap failure
-
Khouri RK. Avoiding free flap failure. Clin Plast Surg. 1992;19:773.
-
(1992)
Clin Plast Surg
, vol.19
, pp. 773
-
-
Khouri, R.K.1
-
4
-
-
0026701102
-
Intraoperative and postoperative monitoring of microsurgical free tissue transfers
-
Jones NF. Intraoperative and postoperative monitoring of microsurgical free tissue transfers. Clin Plast Surg. 1992;19:783.
-
(1992)
Clin Plast Surg
, vol.19
, pp. 783
-
-
Jones, N.F.1
-
5
-
-
0028140059
-
Implantable venous doppler microvascular monitoring: Laboratory investigation and clinical results
-
Swartz WM, Izquierdo R, Miller MJ. Implantable venous Doppler microvascular monitoring: laboratory investigation and clinical results. Plast Reconstr Surg. 1994;93:152-163. (Pubitemid 24015175)
-
(1994)
Plastic and Reconstructive Surgery
, vol.93
, Issue.1
, pp. 152-163
-
-
Swartz, W.M.1
Izquierdo, R.2
Miller, M.J.3
-
6
-
-
0023835477
-
Direct monitoring of microvascular anastomoses with the 20-MHz ultrasonic Doppler probe: An experimental and clinical study
-
Swartz WM, Jones NF, Cherup L, et al. Direct monitoring of microvascular anastomoses with the 20 mHz ultrasonic Doppler probe: an experimental and clinical study. Plast Reconstr Surg. 1988;81:149-158. (Pubitemid 18054317)
-
(1988)
Plastic and Reconstructive Surgery
, vol.81
, Issue.2
, pp. 149-158
-
-
Swartz, W.M.1
Jones, N.F.2
Cherup, L.3
Klein, A.4
-
7
-
-
0024383243
-
Experimental and clinical monitoring of free jejunal transfers using an implantable ultrasonic Doppler probe
-
Jones NF, Rocke AM, Swartz WM, et al. Experimental and clinical monitoring of free jejunal transfers using an implantable ultrasonic Doppler probe. Br J Plast Surg. 1989;42:274-280.
-
(1989)
Br J Plast Surg
, vol.42
, pp. 274-280
-
-
Jones, N.F.1
Rocke, A.M.2
Swartz, W.M.3
-
8
-
-
0030893915
-
Continuous tissue oxygen tension measurement as a monitor of free-flap viability
-
Hirigoyen MB, Blackwell KE, Zhang WX, et al. Continuous tissue oxygen tension measurement as a monitor of free-flap viability. Plast Reconstr Surg. 1997;99:763-773.
-
(1997)
Plast Reconstr Surg
, vol.99
, pp. 763-773
-
-
Hirigoyen, M.B.1
Blackwell, K.E.2
Zhang, W.X.3
-
9
-
-
0022653638
-
Free flap monitoring using a microcomputer linked to a laser Doppler flowmeter
-
Bruce-Chwatt AJ. Free flap monitoring using a microcomputer linked to a laser Doppler flowmeter. Br J Plast Surg. 1986;39:229-238.
-
(1986)
Br J Plast Surg
, vol.39
, pp. 229-238
-
-
Bruce-Chwatt, A.J.1
-
10
-
-
0030804336
-
Intraoral free flap monitoring with a laser doppler flowmeter
-
DOI 10.1002/(SICI)1098-2752(1996)17:6<337::AID-MICR9>3.0.CO;2-E
-
Yoshino K, Nara S, Endo M, et al. Intraoral free flap monitoring with a laser Doppler flowmeter. Microsurgery. 1996;17:337-340. (Pubitemid 27391000)
-
(1997)
Microsurgery
, vol.17
, Issue.6
, pp. 337-340
-
-
Yoshino, K.1
Nara, S.2
Endo, M.3
Kamata, N.4
-
12
-
-
34249932327
-
Non-invasive tissue oximetry for flap monitoring: An initial study
-
Alex Keller. Non-invasive tissue oximetry for flap monitoring: an initial study. J Reconstr Microsurg. 2007;23:189-198.
-
(2007)
J Reconstr Microsurg
, vol.23
, pp. 189-198
-
-
Keller, A.1
-
13
-
-
21844448339
-
Application of near-infrared spectroscopy in monitoring blood perfusion in digital replantation
-
DOI 10.1117/12.611138, 66, Advanced Biomedical and Clinical Diagnostic Systems III
-
Mao JM, Wright L, Elmandjra M. Application of nearinfrared spectroscopy in monitoring blood perfusion in digital replantation. Proc SPIE. 2005;5692: 382-389. (Pubitemid 40954251)
-
(2005)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
, vol.5692
, pp. 382-388
-
-
Mao, J.-M.1
Wright, L.P.2
Elmandjra, M.3
-
14
-
-
0032054550
-
The use of near-infrared spectroscopy for assessing the viability during reconstructive surgery
-
Thorniley MS, Sinclair JS, Barnett NJ, et al. The use of near-infrared spectroscopy for assessing the viability during reconstructive surgery. Br J Plast Surg. 1998;51:218-226.
-
(1998)
Br J Plast Surg
, vol.51
, pp. 218-226
-
-
Thorniley, M.S.1
Sinclair, J.S.2
Barnett, N.J.3
-
15
-
-
0031919750
-
Doppler flowmetry in the planning of perforator flaps
-
DOI 10.1016/S0007-1226(98)80010-6
-
Blondeel PN, Beyens G, Verhaeghe R, et al. Doppler flowmetry in the planning of perforator flaps. Br J Plast Surg. 1998;51:202-209. (Pubitemid 28200956)
-
(1998)
British Journal of Plastic Surgery
, vol.51
, Issue.3
, pp. 202-209
-
-
Blondeel, P.N.1
Beyens, G.2
Verhaeghe, R.3
Van Landuyt, K.4
Tonnard, P.5
Monstrey, S.J.6
Matton, G.7
-
16
-
-
36649008539
-
Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy
-
DOI 10.1016/j.bjps.2007.04.003, PII S1748681507002471
-
Repez A, Oroszy D, Arnez ZM. Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy. J Plast Reconstr Aest Surg. 2008;61:71-77. (Pubitemid 350199113)
-
(2008)
Journal of Plastic, Reconstructive and Aesthetic Surgery
, vol.61
, Issue.1
, pp. 71-77
-
-
Repez, A.1
Oroszy, D.2
Arnez, Z.M.3
-
17
-
-
0031900329
-
The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants
-
Kind GM, Buntic RF, Buncke GM, et al. The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants. Plast Reconstr Surg. 1998;101:1268-1273. (Pubitemid 128724004)
-
(1998)
Plastic and Reconstructive Surgery
, vol.101
, Issue.5
, pp. 1268-1273
-
-
Kind, G.M.1
Buntic, R.F.2
Buncke, G.M.3
Cooper, T.M.4
Siko, P.P.5
Buncke Jr., H.J.6
|