메뉴 건너뛰기




Volumn 61, Issue 10, 2008, Pages 1251-1252

A simple method of implantable Doppler cuff attachment: Experience in 150 DIEP breast reconstructions

Author keywords

[No Author keywords available]

Indexed keywords

BREAST RECONSTRUCTION; DEEP INFERIOR EPIGASTRIC PERFORATOR FLAP; IMPLANT; LETTER; POSTOPERATIVE CARE; PRIORITY JOURNAL; SURGICAL TECHNIQUE;

EID: 51349154543     PISSN: 17486815     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bjps.2008.01.020     Document Type: Letter
Times cited : (16)

References (8)
  • 1
    • 0026730033 scopus 로고
    • Avoiding free flap failure
    • Khouri R.K. Avoiding free flap failure. Clin Plast Surg 19 (1992) 773-781
    • (1992) Clin Plast Surg , vol.19 , pp. 773-781
    • Khouri, R.K.1
  • 2
    • 15844381155 scopus 로고    scopus 로고
    • Master class in plastic surgery : current techniques for the post operative monitoring of free tissue transfers
    • Whitaker I.S., Karoo R.O.S., Oliver D.W., et al. Master class in plastic surgery : current techniques for the post operative monitoring of free tissue transfers. Eur J Plast Surg 27 (2005) 315-321
    • (2005) Eur J Plast Surg , vol.27 , pp. 315-321
    • Whitaker, I.S.1    Karoo, R.O.S.2    Oliver, D.W.3
  • 3
    • 0031900329 scopus 로고    scopus 로고
    • The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants
    • Kind G.M., Buntic R.F., Buncke G.M., et al. The effect of an implantable Doppler probe on the salvage of microvascular tissue transplants. Plast Reconstr Surg 101 (1998) 1268-1273
    • (1998) Plast Reconstr Surg , vol.101 , pp. 1268-1273
    • Kind, G.M.1    Buntic, R.F.2    Buncke, G.M.3
  • 4
    • 0023835477 scopus 로고
    • Direct monitoring of microvascular anastomoses with the 20-MHz ultrasonic Doppler probe: an experimental and clinical study
    • Swartz W.M., Jones N.F., Cherup L., et al. Direct monitoring of microvascular anastomoses with the 20-MHz ultrasonic Doppler probe: an experimental and clinical study. Plast Reconstr Surg 81 (1988) 149-161
    • (1988) Plast Reconstr Surg , vol.81 , pp. 149-161
    • Swartz, W.M.1    Jones, N.F.2    Cherup, L.3
  • 5
    • 0028140059 scopus 로고
    • Implantable venous Doppler microvascular monitoring: laboratory investigation and clinical results
    • Swartz W.M., Izquierdo R., and Miller M.J. Implantable venous Doppler microvascular monitoring: laboratory investigation and clinical results. Plast Reconstr Surg 93 (1994) 152-163
    • (1994) Plast Reconstr Surg , vol.93 , pp. 152-163
    • Swartz, W.M.1    Izquierdo, R.2    Miller, M.J.3
  • 6
    • 51349131623 scopus 로고    scopus 로고
    • Pr44p monitoring buried free flaps - new zealand's first four clinical cases of free flap monitoring with implantable 20 mhz ultrasonic Doppler probe
    • Mistry Y., James D.W., and Sinclair S. Pr44p monitoring buried free flaps - new zealand's first four clinical cases of free flap monitoring with implantable 20 mhz ultrasonic Doppler probe. ANZ J Surg 77 (2007) A70
    • (2007) ANZ J Surg , vol.77
    • Mistry, Y.1    James, D.W.2    Sinclair, S.3
  • 7
    • 14944344874 scopus 로고    scopus 로고
    • The Cook-Swartz venous Doppler probe for the post-operative monitoring of free tissue transfers in the United Kingdom: a preliminary report
    • Oliver D.W., Whitaker I.S., Giele H., et al. The Cook-Swartz venous Doppler probe for the post-operative monitoring of free tissue transfers in the United Kingdom: a preliminary report. Br J Plast Surg 58 (2005) 366-370
    • (2005) Br J Plast Surg , vol.58 , pp. 366-370
    • Oliver, D.W.1    Whitaker, I.S.2    Giele, H.3
  • 8
    • 0035005592 scopus 로고    scopus 로고
    • Fibrin sealant: a novel method of fixation for an implantable ultrasonic microDoppler probe
    • Bill T.J., Foresman P.A., Rodeheaver G.T., et al. Fibrin sealant: a novel method of fixation for an implantable ultrasonic microDoppler probe. J Reconstr Microsurg 17 (2001) 257-262
    • (2001) J Reconstr Microsurg , vol.17 , pp. 257-262
    • Bill, T.J.1    Foresman, P.A.2    Rodeheaver, G.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.