메뉴 건너뛰기




Volumn 47, Issue 3, 2012, Pages 370-380

Nebulizing conditions of pneumatic electrospray ionization significantly influence electrolyte effects on compound measurement

Author keywords

electrolyte effects; electrospray ionization; ginkgo flavonol; ginkgo terpene lactone; matrix effects; signal enhancement; upper limit of quantification

Indexed keywords

ELECTROLYTE EFFECT; ELECTROSPRAYS; GINKGO FLAVONOL; MATRIX EFFECTS; SIGNAL ENHANCEMENT; TERPENE LACTONES; UPPER LIMITS;

EID: 84859073989     PISSN: 10765174     EISSN: 10969888     Source Type: Journal    
DOI: 10.1002/jms.2050     Document Type: Article
Times cited : (12)

References (39)
  • 2
    • 70350507226 scopus 로고    scopus 로고
    • Electrospray: From ions in solution to ions in the gas phase, what we know now
    • P. Kebarle, U. H. Verkerk,. Electrospray: from ions in solution to ions in the gas phase, what we know now. Mass Spectrom. Rev. 2009, 28, 898.
    • (2009) Mass Spectrom. Rev. , vol.28 , pp. 898
    • Kebarle, P.1    Verkerk, U.H.2
  • 3
    • 0042697374 scopus 로고    scopus 로고
    • Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry
    • G. Hopfgartner, E. Bourgogne,. Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry. Mass Spectrom. Rev. 2003, 22, 195.
    • (2003) Mass Spectrom. Rev. , vol.22 , pp. 195
    • Hopfgartner, G.1    Bourgogne, E.2
  • 4
    • 18344396306 scopus 로고    scopus 로고
    • Biochemical applications of mass spectrometry in pharmaceutical drug discovery
    • K. F. Geoghegan, M. A. Kelly,. Biochemical applications of mass spectrometry in pharmaceutical drug discovery. Mass Spectrom. Rev. 2005, 24, 347.
    • (2005) Mass Spectrom. Rev. , vol.24 , pp. 347
    • Geoghegan, K.F.1    Kelly, M.A.2
  • 5
    • 34248582576 scopus 로고    scopus 로고
    • Analytical strategies for identifying drug metabolites
    • C. Prakash, C. L. Shaffer, A. Nedderman,. Analytical strategies for identifying drug metabolites. Mass Spectrom. Rev. 2007, 26, 340.
    • (2007) Mass Spectrom. Rev. , vol.26 , pp. 340
    • Prakash, C.1    Shaffer, C.L.2    Nedderman, A.3
  • 6
    • 0036772773 scopus 로고    scopus 로고
    • A capsule review of recent studies on the application of mass spectrometry in the analysis of Chinese medicinal herbs
    • Z.-W. Cai, F. S. C. Lee, X. R. Wang, W. J. Yu,. A capsule review of recent studies on the application of mass spectrometry in the analysis of Chinese medicinal herbs. J. Mass Spectrom. 2002, 37, 1013.
    • (2002) J. Mass Spectrom. , vol.37 , pp. 1013
    • Cai, Z.-W.1    Lee, F.S.C.2    Wang, X.R.3    Yu, W.J.4
  • 7
    • 75149124674 scopus 로고    scopus 로고
    • Development of liquid chromatography/mass spectrometry methods for the quantitative analysis of herbal medicine in biological fluids: A review
    • M. J. Gray, D. Chang, Y. Zhang, J. Liu, A. Bensoussan,. Development of liquid chromatography/mass spectrometry methods for the quantitative analysis of herbal medicine in biological fluids: a review. Biomed. Chromatogr. 2010, 24, 91.
    • (2010) Biomed. Chromatogr. , vol.24 , pp. 91
    • Gray, M.J.1    Chang, D.2    Zhang, Y.3    Liu, J.4    Bensoussan, A.5
  • 8
    • 33745125997 scopus 로고    scopus 로고
    • The effect of LC eluent composition on MS responses using electrospray ionization
    • D. Temesi, B. Law,. The effect of LC eluent composition on MS responses using electrospray ionization. LC-GC 1999, 17, 626.
    • (1999) LC-GC , vol.17 , pp. 626
    • Temesi, D.1    Law, B.2
  • 9
    • 0033404430 scopus 로고    scopus 로고
    • Effects of salt concentration on analyte response using electrospray ionization mass spectrometry
    • T. L. Constantopoulos, G. S. Jackson, C. G. Enke,. Effects of salt concentration on analyte response using electrospray ionization mass spectrometry. J. Am. Soc. Mass Spectrom. 1999, 10, 625.
    • (1999) J. Am. Soc. Mass Spectrom. , vol.10 , pp. 625
    • Constantopoulos, T.L.1    Jackson, G.S.2    Enke, C.G.3
  • 10
    • 58149112644 scopus 로고    scopus 로고
    • Effect of eluent on the ionization process in liquid chromatography-mass spectrometry
    • R. Kostiainen, T. J. Kauppila,. Effect of eluent on the ionization process in liquid chromatography-mass spectrometry. J. Chromatogr. A 2009, 1216, 685.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 685
    • Kostiainen, R.1    Kauppila, T.J.2
  • 11
    • 0034967897 scopus 로고    scopus 로고
    • Analysis of urinary metabolites of tea catechins by liquid chromatography/electrospray ionization mass spectrometry
    • C. Li, X.-F. Meng, B. Winnik, M.-J. Lee, H. Lu, S.-Q. Sheng, B. Buckley, C. S. Yang,. Analysis of urinary metabolites of tea catechins by liquid chromatography/electrospray ionization mass spectrometry. Chem. Res. Toxicol. 2001, 14, 702.
    • (2001) Chem. Res. Toxicol. , vol.14 , pp. 702
    • Li, C.1    Meng, X.-F.2    Winnik, B.3    Lee, M.-J.4    Lu, H.5    Sheng, S.-Q.6    Buckley, B.7    Yang, C.S.8
  • 12
    • 0036001223 scopus 로고    scopus 로고
    • Influence of the eluent composition on the ionization efficiency for morphine of pneumatically assisted electrospray, atmospheric-pressure chemical ionization and sonic spray
    • R. Dams, T. Benijits, W. Günther, W. Lambert, A. De Leenheer,. Influence of the eluent composition on the ionization efficiency for morphine of pneumatically assisted electrospray, atmospheric-pressure chemical ionization and sonic spray. Rapid Commun. Mass Spectrom. 2002, 16, 1072.
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 1072
    • Dams, R.1    Benijits, T.2    Günther, W.3    Lambert, W.4    De Leenheer, A.5
  • 13
    • 26444543861 scopus 로고    scopus 로고
    • Sensitivity enhancement in liquid chromatography/atmospheric pressure ionization mass spectrometry using derivatization and mobile phase additives
    • S.-M. Gao, Z.-P. Zhang, H. T. Karnes,. Sensitivity enhancement in liquid chromatography/atmospheric pressure ionization mass spectrometry using derivatization and mobile phase additives. J. Chromatogr. B 2005, 825, 98.
    • (2005) J. Chromatogr. B , vol.825 , pp. 98
    • Gao, S.-M.1    Zhang, Z.-P.2    Karnes, H.T.3
  • 14
    • 77953350741 scopus 로고    scopus 로고
    • Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry
    • F. Gosetti, E. Mazzucco, D. Zampieri, M. C. Gennaro,. Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry. J. Chromatogr. A 2010, 1217, 3929.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 3929
    • Gosetti, F.1    Mazzucco, E.2    Zampieri, D.3    Gennaro, M.C.4
  • 15
    • 79952013841 scopus 로고    scopus 로고
    • An overview of matrix effects in liquid chromatography-mass spectrometry
    • H. Trufelli, P. Palma, G. Famiglini, A. Cappiello,. An overview of matrix effects in liquid chromatography-mass spectrometry. Mass Spectrom. Rev. 2011, 30, 491.
    • (2011) Mass Spectrom. Rev. , vol.30 , pp. 491
    • Trufelli, H.1    Palma, P.2    Famiglini, G.3    Cappiello, A.4
  • 16
    • 34249721558 scopus 로고    scopus 로고
    • Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses
    • E. Chambers, D. M. Wagrowski-Diehl, Z. Lu, J. R. Mazzeo,. Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses. J. Chromatogr. B 2007, 852, 22.
    • (2007) J. Chromatogr. B , vol.852 , pp. 22
    • Chambers, E.1    Wagrowski-Diehl, D.M.2    Lu, Z.3    Mazzeo, J.R.4
  • 17
    • 33751368850 scopus 로고    scopus 로고
    • Ion suppression: A major concern in mass spectrometry
    • L. L. Jessome, D. A. Volmer,. Ion suppression: a major concern in mass spectrometry. LCGC North America 2006, 24, 498.
    • (2006) LCGC North America , vol.24 , pp. 498
    • Jessome, L.L.1    Volmer, D.A.2
  • 18
    • 33947317072 scopus 로고    scopus 로고
    • Simultaneous quantification of multiple licorice flavonoids in rat plasma
    • L. Li, S.-P. Liang, F.-F. Du, C. Li,. Simultaneous quantification of multiple licorice flavonoids in rat plasma. J. Am. Soc. Mass Spectrom. 2007, 18, 778.
    • (2007) J. Am. Soc. Mass Spectrom. , vol.18 , pp. 778
    • Li, L.1    Liang, S.-P.2    Du, F.-F.3    Li, C.4
  • 19
    • 33947224577 scopus 로고    scopus 로고
    • A sensitive method for the detection and quantification of ginkgo flavonols from plasma
    • Y. Zhao, L. Wang, Y.-W. Bao, C. Li,. A sensitive method for the detection and quantification of ginkgo flavonols from plasma. Rapid Commun. Mass Spectrom. 2007, 21, 971.
    • (2007) Rapid Commun. Mass Spectrom. , vol.21 , pp. 971
    • Zhao, Y.1    Wang, L.2    Bao, Y.-W.3    Li, C.4
  • 20
    • 40249118716 scopus 로고    scopus 로고
    • Simultaneous determination of ginkgo flavonoids and terpenoids in plasma: Ammonium formate in LC mobile phase enhancing electrospray ionization efficiency and capacity
    • Y. Zhao, Y. Sun, C. Li,. Simultaneous determination of ginkgo flavonoids and terpenoids in plasma: ammonium formate in LC mobile phase enhancing electrospray ionization efficiency and capacity. J. Am. Soc. Mass Spectrom. 2008, 19, 445.
    • (2008) J. Am. Soc. Mass Spectrom. , vol.19 , pp. 445
    • Zhao, Y.1    Sun, Y.2    Li, C.3
  • 21
    • 34547877589 scopus 로고    scopus 로고
    • 'LC-electrolyte effects' improve the bioanalytical performance of liquid chromatography/tandem mass spectrometric assays in supporting pharmacokinetic study for drug discovery
    • L. Wang, Y. Sun, F.-F. Du, W. Niu, T. Lu, J.-M. Kan, F. Xu, K.-H. Yuan, T. Qin, C.-X. Liu, C. Li,. 'LC-electrolyte effects' improve the bioanalytical performance of liquid chromatography/tandem mass spectrometric assays in supporting pharmacokinetic study for drug discovery. Rapid Commun. Mass Spectrom. 2007, 21, 2573.
    • (2007) Rapid Commun. Mass Spectrom. , vol.21 , pp. 2573
    • Wang, L.1    Sun, Y.2    Du, F.-F.3    Niu, W.4    Lu, T.5    Kan, J.-M.6    Xu, F.7    Yuan, K.-H.8    Qin, T.9    Liu, C.-X.10    Li, C.11
  • 22
    • 43649108880 scopus 로고    scopus 로고
    • Pulse gradient, large-volume injection, high-throughput ultra-performance liquid chromatographic/tandem mass spectrometry bioanalysis for measurement of plasma amrubicin and its metabolite amrubicinol
    • Y.-F. Li, Y. Sun, F.-F. Du, K.-H. Yuan, C. Li,. Pulse gradient, large-volume injection, high-throughput ultra-performance liquid chromatographic/tandem mass spectrometry bioanalysis for measurement of plasma amrubicin and its metabolite amrubicinol. J. Chromatogr. A 2008, 1193, 109.
    • (2008) J. Chromatogr. A , vol.1193 , pp. 109
    • Li, Y.-F.1    Sun, Y.2    Du, F.-F.3    Yuan, K.-H.4    Li, C.5
  • 23
    • 0032986050 scopus 로고    scopus 로고
    • The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds
    • R. Bonfiglio, R. C. King, T. V. Olah, K. Merkle,. The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds. Rapid Commun. Mass Spectrom. 1999, 13, 1175.
    • (1999) Rapid Commun. Mass Spectrom. , vol.13 , pp. 1175
    • Bonfiglio, R.1    King, R.C.2    Olah, T.V.3    Merkle, K.4
  • 24
    • 12044253267 scopus 로고
    • From ions in solution to ions in the gas phase: The mechanism of electrospray mass spectrometry
    • P. Kebarle, L. Tang,. From ions in solution to ions in the gas phase: the mechanism of electrospray mass spectrometry. Anal. Chem. 1993, 65, 973A.
    • (1993) Anal. Chem. , vol.65
    • Kebarle, P.1    Tang, L.2
  • 25
    • 0035497781 scopus 로고    scopus 로고
    • Practical implications of some recent studies in electrospray ionization fundamentals
    • N. B. Cech, C. G. Enke,. Practical implications of some recent studies in electrospray ionization fundamentals. Mass Spectrom. Rev. 2001, 20, 362.
    • (2001) Mass Spectrom. Rev. , vol.20 , pp. 362
    • Cech, N.B.1    Enke, C.G.2
  • 26
    • 0037487098 scopus 로고    scopus 로고
    • Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: When does ESI turn into nano-ESI?
    • A. Schmidt, M. Karas, T. Dülcks,. Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI? J. Am. Soc. Mass Spectrom. 2003, 14, 492.
    • (2003) J. Am. Soc. Mass Spectrom. , vol.14 , pp. 492
    • Schmidt, A.1    Karas, M.2    Dülcks, T.3
  • 27
    • 0002884477 scopus 로고    scopus 로고
    • Changes in bulk solution pH caused by the inherent controlled-current electrolytic process of an electrospray ion source
    • G. J. Van Berkel, F.-M. Zhou, J. T. Aronson,. Changes in bulk solution pH caused by the inherent controlled-current electrolytic process of an electrospray ion source. Int. J. Mass Spectrom. Ion Process. 1997, 162, 55.
    • (1997) Int. J. Mass Spectrom. Ion Process. , vol.162 , pp. 55
    • Van Berkel, G.J.1    Zhou, F.-M.2    Aronson, J.T.3
  • 28
    • 0033557548 scopus 로고    scopus 로고
    • Investigation of the electrospray plume by laser-induced fluorescence spectroscopy
    • S.-L. Zhou, A. G. Edwards, K. D. Cook, G. J. Van Berkel,. Investigation of the electrospray plume by laser-induced fluorescence spectroscopy. Anal. Chem. 1999, 71, 769.
    • (1999) Anal. Chem. , vol.71 , pp. 769
    • Zhou, S.-L.1    Edwards, A.G.2    Cook, K.D.3    Van Berkel, G.J.4
  • 29
    • 0036788506 scopus 로고    scopus 로고
    • Profiling pH change in the electrospray plume
    • S.-L. Zhou, B. S. Prebyl, K. D. Cook,. Profiling pH change in the electrospray plume. Anal. Chem. 2002, 74, 4885.
    • (2002) Anal. Chem. , vol.74 , pp. 4885
    • Zhou, S.-L.1    Prebyl, B.S.2    Cook, K.D.3
  • 30
    • 0031298697 scopus 로고    scopus 로고
    • A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes
    • C. G. Enke,. A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes. Anal. Chem. 1997, 69, 4885.
    • (1997) Anal. Chem. , vol.69 , pp. 4885
    • Enke, C.G.1
  • 31
    • 0033404430 scopus 로고    scopus 로고
    • Effects of salt concentration on analyte response using electrospray ionization mass spectrometry
    • T. L. Constantopoulos, G. S. Jackson, C. G. Enke,. Effects of salt concentration on analyte response using electrospray ionization mass spectrometry. J. Am. Soc. Mass Spectrom. 1999, 10, 625.
    • (1999) J. Am. Soc. Mass Spectrom. , vol.10 , pp. 625
    • Constantopoulos, T.L.1    Jackson, G.S.2    Enke, C.G.3
  • 32
  • 33
    • 0001629803 scopus 로고    scopus 로고
    • Droplet Dynamics Changes in Electrostatic Sprays of Methanol-water Mixtures
    • Z. Olumee, J. H. Callahan, A. Vertes,. Droplet Dynamics Changes in Electrostatic Sprays of Methanol-water Mixtures. J. Phys. Chem. A 1998, 102, 9154.
    • (1998) J. Phys. Chem. A , vol.102 , pp. 9154
    • Olumee, Z.1    Callahan, J.H.2    Vertes, A.3
  • 34
    • 0034235367 scopus 로고    scopus 로고
    • Relating electrospray ionization response to nonpolar character of small peptides
    • N. B. Cech, C. G. Enke,. Relating electrospray ionization response to nonpolar character of small peptides. Anal. Chem. 2000, 72, 2717.
    • (2000) Anal. Chem. , vol.72 , pp. 2717
    • Cech, N.B.1    Enke, C.G.2
  • 35
    • 0035863693 scopus 로고    scopus 로고
    • Predicting electrospray response from chromatographic retention time
    • N. B. Cech, J. R. Krone, C. G. Enke,. Predicting electrospray response from chromatographic retention time. Anal. Chem. 2001, 73, 208.
    • (2001) Anal. Chem. , vol.73 , pp. 208
    • Cech, N.B.1    Krone, J.R.2    Enke, C.G.3
  • 36
    • 33344456897 scopus 로고    scopus 로고
    • Relating chromatographic retention and electrophoretic mobility to the ion distribution within electrosprayed droplets
    • C. F. Bökman, D. Bylund, K. E. Markides, P. Sjöberg,. Relating chromatographic retention and electrophoretic mobility to the ion distribution within electrosprayed droplets. J. Am. Soc. Mass Spectrom. 2006, 17, 318.
    • (2006) J. Am. Soc. Mass Spectrom. , vol.17 , pp. 318
    • Bökman, C.F.1    Bylund, D.2    Markides, K.E.3    Sjöberg, P.4
  • 37
    • 0034162462 scopus 로고    scopus 로고
    • Probing solvent fractionation in electrospray droplets with laser-induced fluorescence of a solvatochromic dye
    • S.-L. Zhou, K. D. Cook,. Probing solvent fractionation in electrospray droplets with laser-induced fluorescence of a solvatochromic dye. Anal. Chem. 2000, 72, 963.
    • (2000) Anal. Chem. , vol.72 , pp. 963
    • Zhou, S.-L.1    Cook, K.D.2
  • 39
    • 2042446432 scopus 로고    scopus 로고
    • Simultaneous determination of formate and acetate in whole blood and urine form humans using gas chromatography-mass spectrometry
    • S. Kage, K. Kudo, H. Ikeda, N. Ikeda,. Simultaneous determination of formate and acetate in whole blood and urine form humans using gas chromatography-mass spectrometry. J. Chromatogr. B 2004, 805, 113.
    • (2004) J. Chromatogr. B , vol.805 , pp. 113
    • Kage, S.1    Kudo, K.2    Ikeda, H.3    Ikeda, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.