메뉴 건너뛰기




Volumn 19, Issue 5, 2012, Pages 613-621

Liver Perfusion Imaging in Patients with Primary and Metastatic Liver Malignancy. Prospective Comparison between 99mTc-MAA SPECT and Dynamic CT Perfusion

Author keywords

99mTc MAA SPECT; Computed tomography; Liver; Malignant liver tumor; Perfusion

Indexed keywords

MACROSALB TC 99M; VASCULOTROPIN ANTIBODY;

EID: 84858997818     PISSN: 10766332     EISSN: 18784046     Source Type: Journal    
DOI: 10.1016/j.acra.2011.12.015     Document Type: Article
Times cited : (20)

References (40)
  • 1
    • 34247853402 scopus 로고    scopus 로고
    • Mid-term results in otherwise treatment refractory primary or secondary liver confined tumours treated with selective internal radiation therapy (SIRT) using (90)Yttrium resin-microspheres
    • Jakobs T.F., Hoffmann R.T., Poepperl G., et al. Mid-term results in otherwise treatment refractory primary or secondary liver confined tumours treated with selective internal radiation therapy (SIRT) using (90)Yttrium resin-microspheres. Eur Radiol 2007, 17:1320-1330.
    • (2007) Eur Radiol , vol.17 , pp. 1320-1330
    • Jakobs, T.F.1    Hoffmann, R.T.2    Poepperl, G.3
  • 2
    • 0033778282 scopus 로고    scopus 로고
    • Treatment of nonresectable hepatocellular carcinoma with intrahepatic 90Y-microspheres
    • Dancey J.E., Shepherd F.A., Paul K., et al. Treatment of nonresectable hepatocellular carcinoma with intrahepatic 90Y-microspheres. J Nucl Med 2000, 41:1673-1681.
    • (2000) J Nucl Med , vol.41 , pp. 1673-1681
    • Dancey, J.E.1    Shepherd, F.A.2    Paul, K.3
  • 3
    • 77957874040 scopus 로고    scopus 로고
    • Early prediction of anticancer effects with diffusion-weighted MR imaging in patients with colorectal liver metastases following selective internal radiotherapy
    • Dudeck O., Zeile M., Wybranski C., et al. Early prediction of anticancer effects with diffusion-weighted MR imaging in patients with colorectal liver metastases following selective internal radiotherapy. Eur Radiol 2010, 20:2699-2706.
    • (2010) Eur Radiol , vol.20 , pp. 2699-2706
    • Dudeck, O.1    Zeile, M.2    Wybranski, C.3
  • 4
    • 0034037476 scopus 로고    scopus 로고
    • Analysis of the distribution of intra-arterial microspheres in human liver following hepatic yttrium-90 microsphere therapy
    • Campbell A.M., Bailey I.H., Burton M.A. Analysis of the distribution of intra-arterial microspheres in human liver following hepatic yttrium-90 microsphere therapy. Phys Med Biol 2000, 45:1023-1033.
    • (2000) Phys Med Biol , vol.45 , pp. 1023-1033
    • Campbell, A.M.1    Bailey, I.H.2    Burton, M.A.3
  • 5
    • 0027476378 scopus 로고
    • Hepatic perfusion changes in patients with liver metastases: comparison with those patients with cirrhosis
    • Leen E., Goldberg J.A., Anderson J.R., et al. Hepatic perfusion changes in patients with liver metastases: comparison with those patients with cirrhosis. Gut 1993, 34:554-557.
    • (1993) Gut , vol.34 , pp. 554-557
    • Leen, E.1    Goldberg, J.A.2    Anderson, J.R.3
  • 6
    • 0021349284 scopus 로고
    • Changes of arterial blood flow patterns during infusion chemotherapy, as monitored by intra-arterially injected technetium 99m macroaggregated albumin
    • Bledin A.G., Kim E.E., Chuang V.P., et al. Changes of arterial blood flow patterns during infusion chemotherapy, as monitored by intra-arterially injected technetium 99m macroaggregated albumin. Br J Radiol 1984, 57:197-203.
    • (1984) Br J Radiol , vol.57 , pp. 197-203
    • Bledin, A.G.1    Kim, E.E.2    Chuang, V.P.3
  • 7
    • 67650738915 scopus 로고    scopus 로고
    • Biocompatibility, inflammatory response, and recannalization characteristics of nonradioactive resin microspheres: histological findings
    • Bilbao J.I., de Martino A., de Luis E., et al. Biocompatibility, inflammatory response, and recannalization characteristics of nonradioactive resin microspheres: histological findings. Cardiovasc Intervent Radiol 2009, 32:727-736.
    • (2009) Cardiovasc Intervent Radiol , vol.32 , pp. 727-736
    • Bilbao, J.I.1    de Martino, A.2    de Luis, E.3
  • 8
    • 58149216579 scopus 로고    scopus 로고
    • Multimodality imaging can predict the metabolic response of unresectable colorectal liver metastases to radioembolization therapy with Yttrium-90 labeled resin microspheres
    • Flamen P., Vanderlinden B., Delatte P., et al. Multimodality imaging can predict the metabolic response of unresectable colorectal liver metastases to radioembolization therapy with Yttrium-90 labeled resin microspheres. Phys Med Biol 2008, 53:6591-6603.
    • (2008) Phys Med Biol , vol.53 , pp. 6591-6603
    • Flamen, P.1    Vanderlinden, B.2    Delatte, P.3
  • 9
    • 0030801974 scopus 로고    scopus 로고
    • Tumour-to-normal uptake ratio of 90Y microspheres in hepatic cancer assessed with 99Tcm macroaggregated albumin
    • Ho S., Lau W.Y., Leung T.W., et al. Tumour-to-normal uptake ratio of 90Y microspheres in hepatic cancer assessed with 99Tcm macroaggregated albumin. Br J Radiol 1997, 70:823-828.
    • (1997) Br J Radiol , vol.70 , pp. 823-828
    • Ho, S.1    Lau, W.Y.2    Leung, T.W.3
  • 10
    • 77953250989 scopus 로고    scopus 로고
    • Quantitative comparison of yttrium-90 (90Y)-microspheres and technetium-99m (99mTc)-macroaggregated albumin SPECT images for planning 90Y therapy of liver cancer
    • Knesaurek K., Machac J., Muzinic M., et al. Quantitative comparison of yttrium-90 (90Y)-microspheres and technetium-99m (99mTc)-macroaggregated albumin SPECT images for planning 90Y therapy of liver cancer. Technol Cancer Res Treat 2010, 9:253-262.
    • (2010) Technol Cancer Res Treat , vol.9 , pp. 253-262
    • Knesaurek, K.1    Machac, J.2    Muzinic, M.3
  • 11
    • 0027226363 scopus 로고
    • Functional images of hepatic perfusion obtained with dynamic CT
    • Miles K.A., Hayball M.P., Dixon A.K. Functional images of hepatic perfusion obtained with dynamic CT. Radiology 1993, 188:405-411.
    • (1993) Radiology , vol.188 , pp. 405-411
    • Miles, K.A.1    Hayball, M.P.2    Dixon, A.K.3
  • 12
    • 77954084822 scopus 로고    scopus 로고
    • Performance assessment of dynamic spiral scan modes with variable pitch for quantitative perfusion computed tomography
    • Haberland U., Klotz E., Abolmaali N. Performance assessment of dynamic spiral scan modes with variable pitch for quantitative perfusion computed tomography. Invest Radiol 2010, 45:378-386.
    • (2010) Invest Radiol , vol.45 , pp. 378-386
    • Haberland, U.1    Klotz, E.2    Abolmaali, N.3
  • 13
    • 77954088057 scopus 로고    scopus 로고
    • Quantitative computed tomography liver perfusion imaging using dynamic spiral scanning with variable pitch: feasibility and initial results in patients with cancer metastases
    • Goetti R., Leschka S., Desbiolles L., et al. Quantitative computed tomography liver perfusion imaging using dynamic spiral scanning with variable pitch: feasibility and initial results in patients with cancer metastases. Invest Radiol 2010, 45:419-426.
    • (2010) Invest Radiol , vol.45 , pp. 419-426
    • Goetti, R.1    Leschka, S.2    Desbiolles, L.3
  • 14
    • 69449095265 scopus 로고    scopus 로고
    • Early detection of local RFA site recurrence using total liver volume perfusion CT initial experience
    • Meijerink M.R., van Waesberghe J.H., van der Weide L., et al. Early detection of local RFA site recurrence using total liver volume perfusion CT initial experience. Acad Radiol 2009, 16:1215-1222.
    • (2009) Acad Radiol , vol.16 , pp. 1215-1222
    • Meijerink, M.R.1    van Waesberghe, J.H.2    van der Weide, L.3
  • 15
    • 47749148381 scopus 로고    scopus 로고
    • Hepatocellular carcinoma in cirrhotic liver disease: functional computed tomography with perfusion imaging in the assessment of tumor vascularization
    • Ippolito D., Sironi S., Pozzi M., et al. Hepatocellular carcinoma in cirrhotic liver disease: functional computed tomography with perfusion imaging in the assessment of tumor vascularization. Acad Radiol 2008, 15:919-927.
    • (2008) Acad Radiol , vol.15 , pp. 919-927
    • Ippolito, D.1    Sironi, S.2    Pozzi, M.3
  • 16
    • 77955127062 scopus 로고    scopus 로고
    • Metastatic renal carcinoma: evaluation of antiangiogenic therapy with dynamic contrast-enhanced CT
    • Fournier L.S., Oudard S., Thiam R., et al. Metastatic renal carcinoma: evaluation of antiangiogenic therapy with dynamic contrast-enhanced CT. Radiology 2010, 256:511-518.
    • (2010) Radiology , vol.256 , pp. 511-518
    • Fournier, L.S.1    Oudard, S.2    Thiam, R.3
  • 17
    • 78651248406 scopus 로고    scopus 로고
    • Angiogenesis of renal cell carcinoma: perfusion CT findings
    • Chen Y., Zhang J., Dai J., et al. Angiogenesis of renal cell carcinoma: perfusion CT findings. Abdom Imaging 2010, 35:622-628.
    • (2010) Abdom Imaging , vol.35 , pp. 622-628
    • Chen, Y.1    Zhang, J.2    Dai, J.3
  • 18
    • 59249106620 scopus 로고    scopus 로고
    • Can perfusion CT assessment of primary colorectal adenocarcinoma blood flow at staging predict for subsequent metastatic disease? A pilot study
    • Goh V., Halligan S., Wellsted D.M., et al. Can perfusion CT assessment of primary colorectal adenocarcinoma blood flow at staging predict for subsequent metastatic disease? A pilot study. Eur Radiol 2009, 19:79-89.
    • (2009) Eur Radiol , vol.19 , pp. 79-89
    • Goh, V.1    Halligan, S.2    Wellsted, D.M.3
  • 19
    • 63449125190 scopus 로고    scopus 로고
    • Computed tomography perfusion in evaluating the therapeutic effect of transarterial chemoembolization for hepatocellular carcinoma
    • Chen G., Ma D.Q., He W., et al. Computed tomography perfusion in evaluating the therapeutic effect of transarterial chemoembolization for hepatocellular carcinoma. World J Gastroenterol 2008, 14:5738-5743.
    • (2008) World J Gastroenterol , vol.14 , pp. 5738-5743
    • Chen, G.1    Ma, D.Q.2    He, W.3
  • 20
    • 36249003868 scopus 로고    scopus 로고
    • Large deformation registration of contrast-enhanced images with volume-preserving constraint
    • In: Pluim JPW, Reinhard JM, eds. Medical Imaging 2007: Image Processing. Bellingham, WA: Proceedings of The International Society for Optical Engineering (SPIE)
    • Saddi KA, Chefd'hotel C, Cheriet F. Large deformation registration of contrast-enhanced images with volume-preserving constraint. In: Pluim JPW, Reinhard JM, eds. Medical Imaging 2007: Image Processing. Bellingham, WA: Proceedings of The International Society for Optical Engineering (SPIE), 2007.
    • (2007)
    • Saddi, K.A.1    Chefd'hotel, C.2    Cheriet, F.3
  • 22
    • 0942287356 scopus 로고    scopus 로고
    • Quantitative perfusion map of malignant liver tumors, created from dynamic computed tomography data
    • Tsushima Y., Funabasama S., Aoki J., et al. Quantitative perfusion map of malignant liver tumors, created from dynamic computed tomography data. Acad Radiol 2004, 11:215-223.
    • (2004) Acad Radiol , vol.11 , pp. 215-223
    • Tsushima, Y.1    Funabasama, S.2    Aoki, J.3
  • 23
    • 66149128888 scopus 로고    scopus 로고
    • SPECT/CT with 99mTc-MAA in radioembolization with 90Y microspheres in patients with hepatocellular cancer
    • Hamami M.E., Poeppel T.D., Muller S., et al. SPECT/CT with 99mTc-MAA in radioembolization with 90Y microspheres in patients with hepatocellular cancer. J Nucl Med 2009, 50:688-692.
    • (2009) J Nucl Med , vol.50 , pp. 688-692
    • Hamami, M.E.1    Poeppel, T.D.2    Muller, S.3
  • 24
    • 77956209027 scopus 로고    scopus 로고
    • The significance of 99mTc-MAA SPECT/CT liver perfusion imaging in treatment planning for 90Y-microsphere selective internal radiation treatment
    • Ahmadzadehfar H., Sabet A., Biermann K., et al. The significance of 99mTc-MAA SPECT/CT liver perfusion imaging in treatment planning for 90Y-microsphere selective internal radiation treatment. J Nucl Med 2010, 51:1206-1212.
    • (2010) J Nucl Med , vol.51 , pp. 1206-1212
    • Ahmadzadehfar, H.1    Sabet, A.2    Biermann, K.3
  • 25
    • 0021189571 scopus 로고
    • Definition of hepatic tumor microcirculation by single photon emission computerized tomography (SPECT)
    • Gyves J.W., Ziessman H.A., Ensminger W.D., et al. Definition of hepatic tumor microcirculation by single photon emission computerized tomography (SPECT). J Nucl Med 1984, 25:972-977.
    • (1984) J Nucl Med , vol.25 , pp. 972-977
    • Gyves, J.W.1    Ziessman, H.A.2    Ensminger, W.D.3
  • 26
    • 0023600279 scopus 로고
    • Single photon emission computed tomographic studies (SPECT) of hepatic arterial perfusion scintigraphy (HAPS) in patients with colorectal liver metastases: improved tumour targetting by microspheres with angiotensin II
    • Goldberg J.A., Bradnam M.S., Kerr D.J., et al. Single photon emission computed tomographic studies (SPECT) of hepatic arterial perfusion scintigraphy (HAPS) in patients with colorectal liver metastases: improved tumour targetting by microspheres with angiotensin II. Nucl Med Commun 1987, 8:1025-1032.
    • (1987) Nucl Med Commun , vol.8 , pp. 1025-1032
    • Goldberg, J.A.1    Bradnam, M.S.2    Kerr, D.J.3
  • 27
    • 0029737746 scopus 로고    scopus 로고
    • Partition model for estimating radiation doses from yttrium-90 microspheres in treating hepatic tumours
    • Ho S., Lau W.Y., Leung T.W., et al. Partition model for estimating radiation doses from yttrium-90 microspheres in treating hepatic tumours. Eur J Nucl Med 1996, 23:947-952.
    • (1996) Eur J Nucl Med , vol.23 , pp. 947-952
    • Ho, S.1    Lau, W.Y.2    Leung, T.W.3
  • 28
    • 77953133233 scopus 로고    scopus 로고
    • Safety and efficacy assessment of flow redistribution by occlusion of intrahepatic vessels prior to radioembolization in the treatment of liver tumors
    • Bilbao J.I., Garrastachu P., Herraiz M.J., et al. Safety and efficacy assessment of flow redistribution by occlusion of intrahepatic vessels prior to radioembolization in the treatment of liver tumors. Cardiovasc Intervent Radiol 2010, 33:523-531.
    • (2010) Cardiovasc Intervent Radiol , vol.33 , pp. 523-531
    • Bilbao, J.I.1    Garrastachu, P.2    Herraiz, M.J.3
  • 29
    • 78651257244 scopus 로고    scopus 로고
    • Feasibility of integrated CT-liver perfusion in routine FDG-PET/CT
    • Veit-Haibach P., Treyer V., Strobel K., et al. Feasibility of integrated CT-liver perfusion in routine FDG-PET/CT. Abdom Imaging 2010, 35:528-536.
    • (2010) Abdom Imaging , vol.35 , pp. 528-536
    • Veit-Haibach, P.1    Treyer, V.2    Strobel, K.3
  • 30
    • 0035144643 scopus 로고    scopus 로고
    • Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT
    • Cuenod C., Leconte I., Siauve N., et al. Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT. Radiology 2001, 218:556-561.
    • (2001) Radiology , vol.218 , pp. 556-561
    • Cuenod, C.1    Leconte, I.2    Siauve, N.3
  • 31
    • 78651054955 scopus 로고
    • The blood supply of neoplasms in the liver
    • Breedis C., Young G. The blood supply of neoplasms in the liver. Am J Pathol 1954, 30:969-977.
    • (1954) Am J Pathol , vol.30 , pp. 969-977
    • Breedis, C.1    Young, G.2
  • 32
    • 70350166688 scopus 로고    scopus 로고
    • Whole-organ perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma: acquisition technique, post-processing and initial results
    • Kandel S., Kloeters C., Meyer H., et al. Whole-organ perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma: acquisition technique, post-processing and initial results. Eur Radiol 2009, 19:2641-2646.
    • (2009) Eur Radiol , vol.19 , pp. 2641-2646
    • Kandel, S.1    Kloeters, C.2    Meyer, H.3
  • 33
    • 51349109272 scopus 로고    scopus 로고
    • Perfusion CT of the brain using 40-mm-wide detector and toggling table technique for initial imaging of acute stroke
    • Youn S.W., Kim J.H., Weon Y.C., et al. Perfusion CT of the brain using 40-mm-wide detector and toggling table technique for initial imaging of acute stroke. AJR Am J Roentgenol 2008, 191:W120-W126.
    • (2008) AJR Am J Roentgenol , vol.191
    • Youn, S.W.1    Kim, J.H.2    Weon, Y.C.3
  • 34
    • 77954083771 scopus 로고    scopus 로고
    • Determination of glomerular filtration rate using dynamic CT-angiography: simultaneous acquisition of morphological and functional information
    • Helck A., Sommer W.H., Klotz E., et al. Determination of glomerular filtration rate using dynamic CT-angiography: simultaneous acquisition of morphological and functional information. Invest Radiol 2010, 45:387-392.
    • (2010) Invest Radiol , vol.45 , pp. 387-392
    • Helck, A.1    Sommer, W.H.2    Klotz, E.3
  • 35
    • 57149087739 scopus 로고    scopus 로고
    • Effect of temporal interval between scan acquisitions on quantitative vascular parameters in colorectal cancer: implications for helical volumetric perfusion CT techniques
    • Goh V., Liaw J., Bartram C.I., et al. Effect of temporal interval between scan acquisitions on quantitative vascular parameters in colorectal cancer: implications for helical volumetric perfusion CT techniques. AJR Am J Roentgenol 2008, 191:W288-W292.
    • (2008) AJR Am J Roentgenol , vol.191
    • Goh, V.1    Liaw, J.2    Bartram, C.I.3
  • 36
    • 79954430869 scopus 로고    scopus 로고
    • Radiation dose from volumetric helical perfusion CT of the thorax, abdomen or pelvis
    • Goh V., Dattani M., Farwell J., et al. Radiation dose from volumetric helical perfusion CT of the thorax, abdomen or pelvis. Eur Radiol 2011, 21:974-981.
    • (2011) Eur Radiol , vol.21 , pp. 974-981
    • Goh, V.1    Dattani, M.2    Farwell, J.3
  • 37
    • 77951782746 scopus 로고    scopus 로고
    • Comparison between perfusion computed tomography and dynamic contrast-enhanced magnetic resonance imaging in rectal cancer
    • Kierkels R.G., Backes W.H., Janssen M.H., et al. Comparison between perfusion computed tomography and dynamic contrast-enhanced magnetic resonance imaging in rectal cancer. Int J Radiat Oncol Biol Phys 2010, 77:400-408.
    • (2010) Int J Radiat Oncol Biol Phys , vol.77 , pp. 400-408
    • Kierkels, R.G.1    Backes, W.H.2    Janssen, M.H.3
  • 38
    • 84155167800 scopus 로고    scopus 로고
    • Quantitative perfusion analysis of malignant liver tumors: dynamic computed tomography and contrast-enhanced ultrasound
    • Goetti R., Reiner C.S., Knuth A., et al. Quantitative perfusion analysis of malignant liver tumors: dynamic computed tomography and contrast-enhanced ultrasound. Invest Radiol 2012, 47:18-24.
    • (2012) Invest Radiol , vol.47 , pp. 18-24
    • Goetti, R.1    Reiner, C.S.2    Knuth, A.3
  • 39
    • 34447330414 scopus 로고    scopus 로고
    • Comparison of liver perfusion parameters studied with conventional extravascular and experimental intravascular CT contrast agents
    • Kapanen M., Halavaara J., Hakkinen A.M. Comparison of liver perfusion parameters studied with conventional extravascular and experimental intravascular CT contrast agents. Acad Radiol 2007, 14:951-958.
    • (2007) Acad Radiol , vol.14 , pp. 951-958
    • Kapanen, M.1    Halavaara, J.2    Hakkinen, A.M.3
  • 40
    • 0028049228 scopus 로고
    • Measuring lung shunting in hepatocellular carcinoma with intrahepatic-arterial technetium-99m macroaggregated albumin
    • Leung W.T., Lau W.Y., Ho S.K., et al. Measuring lung shunting in hepatocellular carcinoma with intrahepatic-arterial technetium-99m macroaggregated albumin. J Nucl Med 1994, 35:70-73.
    • (1994) J Nucl Med , vol.35 , pp. 70-73
    • Leung, W.T.1    Lau, W.Y.2    Ho, S.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.