메뉴 건너뛰기




Volumn 19, Issue 1, 2012, Pages 3-28

Sensors and systems for the detection of explosive devices - An overview

Author keywords

Detection of explosive materials; Explosive device sensors

Indexed keywords

CHROMATOGRAPHY; EXPLOSIVES DETECTION; GAS CHROMATOGRAPHY; MAGNETIC RESONANCE;

EID: 84858696287     PISSN: 08608229     EISSN: None     Source Type: Journal    
DOI: 10.2478/v10178-012-0001-3     Document Type: Article
Times cited : (97)

References (106)
  • 2
    • 0032289373 scopus 로고    scopus 로고
    • Review of one-side approaches to radiographic imaging for the detection of explosives and narcotics
    • Hussein, E.M.A., Walker, E.J. (1998). Review of one-side approaches to radiographic imaging for the detection of explosives and narcotics. Radiation Measurements, 29(6), 581-591.
    • (1998) Radiation Measurements , vol.29 , Issue.6 , pp. 581-591
    • Hussein, E.M.A.1    Walker, E.J.2
  • 3
    • 39149137577 scopus 로고    scopus 로고
    • Ion mobility-mass spectrometry
    • Wiley Inter Science, DOI:10.1002/jms.1383
    • Kanu, A.B., Dwivedi, P., Tam, M., Herbert, L.M., Hill, H. (2008). Ion mobility-mass spectrometry. Mass Spectrom., 43, 1-22. Wiley Inter Science (www.interscience.wiley.com) DOI:10.1002/jms.1383.
    • (2008) Mass Spectrom , vol.43 , pp. 1-22
    • Kanu, A.B.1    Dwivedi, P.2    Tam, M.3    Herbert, L.M.4    Hill, H.5
  • 5
    • 0037210269 scopus 로고    scopus 로고
    • Review of Explosives detection systems for aviation security
    • Singh, S., Singh, M. (2003). Review of Explosives detection systems for aviation security. Signal Processing, 83, 31-55.
    • (2003) Signal Processing , vol.83 , pp. 31-55
    • Singh, S.1    Singh, M.2
  • 6
    • 4344634690 scopus 로고    scopus 로고
    • Radiation, X-ray scatter tomography for explosives detection
    • Harding, G. (2004). Radiation, X-ray scatter tomography for explosives detection. Physics and Chemistry, 71, 869-881.
    • (2004) Physics and Chemistry , vol.71 , pp. 869-881
    • Harding, G.1
  • 7
    • 34547850121 scopus 로고    scopus 로고
    • Search by X-rays applied technology
    • Vogel, H. (2007). Search by X-rays applied technology. European Journal of Radiology, 63, 227-236.
    • (2007) European Journal of Radiology , vol.63 , pp. 227-236
    • Vogel, H.1
  • 8
    • 39649088448 scopus 로고    scopus 로고
    • Comparison of neutron and high-energy X-ray dual-beam radio-graphy for air cargo inspection
    • Liu, Y., Sowerby, B.D., Tickner, J.R. (2008). Comparison of neutron and high-energy X-ray dual-beam radio-graphy for air cargo inspection. Applied Radiation and Isotopes, 66, 463-473.
    • (2008) Applied Radiation and Isotopes , vol.66 , pp. 463-473
    • Liu, Y.1    Sowerby, B.D.2    Tickner, J.R.3
  • 12
    • 4344634691 scopus 로고    scopus 로고
    • Contraband detection with fast neutrons
    • Buffler, A. (2004). Contraband detection with fast neutrons. Radiation Physics and Chemistry, 71, 853-861.
    • (2004) Radiation Physics and Chemistry , vol.71 , pp. 853-861
    • Buffler, A.1
  • 13
    • 37749020015 scopus 로고    scopus 로고
    • Explosives Detection System: Development and Enhancements
    • Reber, E.L., Larry, C., Blackwood, G. (2007). Explosives Detection System: Development and Enhancements. Sens Imaging, 8, 121-130.
    • (2007) Sens Imaging , vol.8 , pp. 121-130
    • Reber, E.L.1    Larry, C.2    Blackwood, G.3
  • 14
    • 65449176740 scopus 로고    scopus 로고
    • Photon and neutron interrogation techniques for chemical explosives detection in air cargo
    • Runkle, R.C., White, T.A. (2009). Photon and neutron interrogation techniques for chemical explosives detection in air cargo. Nuclear Instruments and Methods in Physics Research A, 603, 510-528.
    • (2009) Nuclear Instruments and Methods in Physics Research A , vol.603 , pp. 510-528
    • Runkle, R.C.1    White, T.A.2
  • 15
    • 80955142810 scopus 로고    scopus 로고
    • Detection of explosive remnants of war by neutron thermalisation
    • Brooks, F.D., Drosg, M., Smit, F.D., Wikner, C. (2011). Detection of explosive remnants of war by neutron thermalisation. Applied Radiation and Isotopes, 70(1), 119-127.
    • (2011) Applied Radiation and Isotopes , vol.70 , Issue.1 , pp. 119-127
    • Brooks, F.D.1    Drosg, M.2    Smit, F.D.3    Wikner, C.4
  • 17
    • 79955053747 scopus 로고    scopus 로고
    • Detection and identification of explosives and illicit drugs using neutron based techniques
    • Papp, A., Csikai, J. (2011). Detection and identification of explosives and illicit drugs using neutron based techniques. J. Radioanal. Nucl. Chem., 288, 363-371.
    • (2011) J. Radioanal. Nucl. Chem , vol.288 , pp. 363-371
    • Papp, A.1    Csikai, J.2
  • 19
    • 80051672157 scopus 로고    scopus 로고
    • 1-Nitratoethyl-5-nitriminotetrazole derivatives-Shaping future high explosives
    • Fischer, N., Klapötke, T.M., Stierstorfer, J., Wiedemann, C. (2011). 1-Nitratoethyl-5-nitriminotetrazole derivatives-Shaping future high explosives. Polyhedron, 30, 2374-2386.
    • (2011) Polyhedron , vol.30 , pp. 2374-2386
    • Fischer, N.1    Klapötke, T.M.2    Stierstorfer, J.3    Wiedemann, C.4
  • 20
    • 0034657359 scopus 로고    scopus 로고
    • From dating to biophysics D20 years of progress in applied ESR spectroscopy
    • Regulla, D. (2000). From dating to biophysics D20 years of progress in applied ESR spectroscopy. Applied Radiation and Isotopes, 52, 1023-1030.
    • (2000) Applied Radiation and Isotopes , vol.52 , pp. 1023-1030
    • Regulla, D.1
  • 22
    • 77956593645 scopus 로고    scopus 로고
    • CMOS Receiver Front-end for Nuclear Quadrupole Resonance Based Explosives Detection
    • Zhang, X., Balki{dotless}r, S., Hoffman, M.W., Schemm, N., Robust, A. (2010). CMOS Receiver Front-end for Nuclear Quadrupole Resonance Based Explosives Detection. IEEE-Circuits and Systems, 53(8), 1093-1096.
    • (2010) IEEE-Circuits and Systems , vol.53 , Issue.8 , pp. 1093-1096
    • Zhang, X.1    Balkir, S.2    Hoffman, M.W.3    Schemm, N.4    Robust, A.5
  • 23
    • 77952867220 scopus 로고    scopus 로고
    • The effects of Gd doping and oxygen vacancies on the properties of EuO films prepared via pulsed laser deposition
    • Wang, X., Liu, P., Fox, K.A., Tang, J., Colón Santana, J.A., Belashchenko, K., Dowben, P.A., Sui, Y. (2010). The effects of Gd doping and oxygen vacancies on the properties of EuO films prepared via pulsed laser deposition. IEEE Trans. Magn., 46, 1879-1882.
    • (2010) IEEE Trans. Magn , vol.46 , pp. 1879-1882
    • Wang, X.1    Liu, P.2    Fox, K.A.3    Tang, J.4    Colón Santana, J.A.5    Belashchenko, K.6    Dowben, P.A.7    Sui, Y.8
  • 25
    • 67349099937 scopus 로고    scopus 로고
    • TNT detection with 14N NQR: Multipulse sequences and matched filter
    • Gregorovic, A., Apih, T. (2009). TNT detection with 14N NQR: Multipulse sequences and matched filter. Journal of Magnetic Resonance, 198, 215-221.
    • (2009) Journal of Magnetic Resonance , vol.198 , pp. 215-221
    • Gregorovic, A.1    Apih, T.2
  • 27
    • 33845446741 scopus 로고    scopus 로고
    • 14N-NQR based device for detection of explosives in landmines
    • Ostafin, M., Nogaj, B. (2007). 14N-NQR based device for detection of explosives in landmines. Measurement, 40, 43-54.
    • (2007) Measurement , vol.40 , pp. 43-54
    • Ostafin, M.1    Nogaj, B.2
  • 29
    • 0035499851 scopus 로고    scopus 로고
    • Array-to-Array Transfer of an Artificial Nose Classifier
    • Stitzel, S.E., Cowen, L.J., Albert, K.J., Walt, D.R. (2001). Array-to-Array Transfer of an Artificial Nose Classifier. Anal. Chem., 73(21), 5266-5271.
    • (2001) Anal. Chem , vol.73 , Issue.21 , pp. 5266-5271
    • Stitzel, S.E.1    Cowen, L.J.2    Albert, K.J.3    Walt, D.R.4
  • 30
    • 0037086391 scopus 로고    scopus 로고
    • Properties of Vapor Detector Arrays Formed through Plasticization of Carbon Black-Organic Polymer Composites
    • Koscho, M.E., Grubbs, R.H., Lewis, N.S. (2002). Properties of Vapor Detector Arrays Formed through Plasticization of Carbon Black-Organic Polymer Composites. Anal. Chem., 74, 1307-1315.
    • (2002) Anal. Chem , vol.74 , pp. 1307-1315
    • Koscho, M.E.1    Grubbs, R.H.2    Lewis, N.S.3
  • 31
    • 0032119626 scopus 로고    scopus 로고
    • Colloidal metal-insulator-metal ensemble chemiresistor sensor
    • Wohltejen, H., Snow, A.W. (1998). Colloidal metal-insulator-metal ensemble chemiresistor sensor. Anal. Chem., 70, 2856-2859.
    • (1998) Anal. Chem , vol.70 , pp. 2856-2859
    • Wohltejen, H.1    Snow, A.W.2
  • 34
    • 84858679667 scopus 로고    scopus 로고
    • Measurement, modeling and evaluation of surface parameter using capacitive-sensor-based measurement system
    • Murugarajan, A., Samuel, G.L. (2011). Measurement, modeling and evaluation of surface parameter using capacitive-sensor-based measurement system, Metrology and Measurement Systems, 18(3), 403-418.
    • (2011) Metrology and Measurement Systems , vol.18 , Issue.3 , pp. 403-418
    • Murugarajan, A.1    Samuel, G.L.2
  • 35
    • 84858629968 scopus 로고    scopus 로고
    • http://science.nasa.gov/science-news/science-at-nasa/2004/06oct_enose (2011).
    • (2011)
  • 36
    • 84858676607 scopus 로고    scopus 로고
    • http://www.prenhall.com/settle/chapters/ch31.pdf (2011).
    • (2011)
  • 37
    • 33745755385 scopus 로고    scopus 로고
    • Fast Gas Chromatography of Explosive Compounds Using a Pulsed-Discharge Electron Capture Detector
    • Collin, O.L., Niegel, C., DeRhodes, K.E., McCord, B., Jackson, G.P. (2006). Fast Gas Chromatography of Explosive Compounds Using a Pulsed-Discharge Electron Capture Detector. Journal of Forensic Sciences, 51, 815-818.
    • (2006) Journal of Forensic Sciences , vol.51 , pp. 815-818
    • Collin, O.L.1    Niegel, C.2    de Rhodes, K.E.3    McCord, B.4    Jackson, G.P.5
  • 38
    • 84858629967 scopus 로고    scopus 로고
    • http://www.interactpartnership.co.uk/members/technologies/23.pdf (2011).
    • (2011)
  • 39
    • 84858676608 scopus 로고    scopus 로고
    • www.iut-berlin.info/fileadmin/user_upload/Literatur/Poster_Symposium_ISADE_FINEX.pdf (2011).
    • (2011)
  • 40
    • 84858676610 scopus 로고    scopus 로고
    • http://sniffexquestions.blogspot.com/2007/09/what-about-ade-100-ade-101-ade650-ade.html (2011).
    • (2011)
  • 41
    • 84858687403 scopus 로고    scopus 로고
    • http://www.scribd.com/doc/56952947/38/The-Electron-Capture-Detector (2011).
    • (2011)
  • 42
    • 78650433198 scopus 로고    scopus 로고
    • Sensitivity of polarimetric waveguide interferometer for different waveguides
    • Gut, K., Zakrzewski, A., Pustelny, T. (2010). Sensitivity of polarimetric waveguide interferometer for different waveguides. Acta Physica Polonica A, 118(6), 1140-1142.
    • (2010) Acta Physica Polonica A , vol.118 , Issue.6 , pp. 1140-1142
    • Gut, K.1    Zakrzewski, A.2    Pustelny, T.3
  • 43
    • 33745767682 scopus 로고    scopus 로고
    • Polymer sensors for nitroaromatic explosives detection
    • Toaland, S.J., Trogler, W. (2006). Polymer sensors for nitroaromatic explosives detection. J. Mater. Chem., 16, 2871-2883.
    • (2006) J. Mater. Chem , vol.16 , pp. 2871-2883
    • Toaland, S.J.1    Trogler, W.2
  • 44
    • 20744445245 scopus 로고    scopus 로고
    • Detecting Chemical Vapours from Explosives Using the zNose®, an Ultra-High Speed Gas Chromatograph, Electronic Noses & Sensors for the Detection of Explosives
    • Staples, E.J. (2004). Detecting Chemical Vapours from Explosives Using the zNose®, an Ultra-High Speed Gas Chromatograph, Electronic Noses & Sensors for the Detection of Explosives. NATO Science Series, 159, 235-248.
    • (2004) NATO Science Series , vol.159 , pp. 235-248
    • Staples, E.J.1
  • 45
    • 33947392177 scopus 로고    scopus 로고
    • Application of Electronic Noses for Disease Diagnosis and Food Spoilage Detection
    • Casalinuovo, I.A., Di Pierro, D., Coletta, M., Di Francesco, P. (2006). Application of Electronic Noses for Disease Diagnosis and Food Spoilage Detection. Sensors, 6, 1428-1439.
    • (2006) Sensors , vol.6 , pp. 1428-1439
    • Casalinuovo, I.A.1    di Pierro, D.2    Coletta, M.3    di Francesco, P.4
  • 46
    • 70849128864 scopus 로고    scopus 로고
    • Applications and Advances in Electronic-Nose Technologies
    • Wilson, A.D., Baietto, M. (2009). Applications and Advances in Electronic-Nose Technologies. Sensors, 9, 5099-5148.
    • (2009) Sensors , vol.9 , pp. 5099-5148
    • Wilson, A.D.1    Baietto, M.2
  • 48
    • 34248221076 scopus 로고    scopus 로고
    • Sensors-an effective approach for the detection of explosives
    • Singh, S. (2007). Sensors-an effective approach for the detection of explosives. Journal of Hazardous Materials, 144, 15-28.
    • (2007) Journal of Hazardous Materials , vol.144 , pp. 15-28
    • Singh, S.1
  • 49
    • 0036139997 scopus 로고    scopus 로고
    • Amperometric TNT biosensor based on the oriented immobilization of a nitroreductase maltose binding protein fusion
    • Naal, Z., Park, J.H., Bernhard, S., Shapleigh, J.P., Batt, C.A., Abrun, H.D. (2002). Amperometric TNT biosensor based on the oriented immobilization of a nitroreductase maltose binding protein fusion. Analytical Chemistry, 74, 140.
    • (2002) Analytical Chemistry , vol.74 , pp. 140
    • Naal, Z.1    Park, J.H.2    Bernhard, S.3    Shapleigh, J.P.4    Batt, C.A.5    Abrun, H.D.6
  • 50
  • 51
    • 79951507376 scopus 로고    scopus 로고
    • Detection and analysis of cyclotrimethylenetrinitramine (RDX) in environmental samples by surface-enhanced Raman spectroscopy
    • Hatab, N.A., Eres, G., Hatzingerc, P.B., Gua, B. (2010). Detection and analysis of cyclotrimethylenetrinitramine (RDX) in environmental samples by surface-enhanced Raman spectroscopy. J. Raman Spectroscopy, 41, 1131-1136.
    • (2010) J. Raman Spectroscopy , vol.41 , pp. 1131-1136
    • Hatab, N.A.1    Eres, G.2    Hatzingerc, P.B.3    Gua, B.4
  • 53
    • 84858629984 scopus 로고    scopus 로고
    • http://www.sciencedaily.com/releases/2011/05/110509161759.htm (2011).
    • (2011)
  • 55
    • 84858629985 scopus 로고    scopus 로고
    • Optimized capacitive MEMS microphone for photoacoustic spectroscopy (PAS) applications
    • Pedersen, M., McClelland, J. (2005). Optimized capacitive MEMS microphone for photoacoustic spectroscopy (PAS) applications. Proc. SPIE, 108, 5732.
    • (2005) Proc. SPIE , vol.108 , pp. 5732
    • Pedersen, M.1    McClelland, J.2
  • 56
    • 21244470733 scopus 로고    scopus 로고
    • Diode laser-based photoacoustic spectroscopy with interferometrically-enhanced cantilever detection
    • Laurila, T., Cattaneo, H., Koskinen, V., Kauppinen, J., Hernberg, R. (2005). Diode laser-based photoacoustic spectroscopy with interferometrically-enhanced cantilever detection. Opt. Express, 13, 2453-2458.
    • (2005) Opt. Express , vol.13 , pp. 2453-2458
    • Laurila, T.1    Cattaneo, H.2    Koskinen, V.3    Kauppinen, J.4    Hernberg, R.5
  • 57
    • 84858629986 scopus 로고    scopus 로고
    • http://www.sciencedaily.com/releases/2008/06/080625153328.htm (2011).
    • (2011)
  • 58
    • 54749120542 scopus 로고    scopus 로고
    • Experimental setup for characterization of self-actuated microcantilevers with piezoresistive readout for chemical recognition of volatile substances
    • Filenko, D., Ivanov, T., Volland, B.E., Ivanova, K., Rangelow, I.W., Nikolov, N., Gotszalk, T., Mielczarski, J. (2008). Experimental setup for characterization of self-actuated microcantilevers with piezoresistive readout for chemical recognition of volatile substances. Rev. Sci. Instr., 79, 094101-6.
    • (2008) Rev. Sci. Instr , vol.79 , pp. 094101-094106
    • Filenko, D.1    Ivanov, T.2    Volland, B.E.3    Ivanova, K.4    Rangelow, I.W.5    Nikolov, N.6    Gotszalk, T.7    Mielczarski, J.8
  • 59
    • 84858677625 scopus 로고    scopus 로고
    • http://www.arete.com/index.php?view=stil_mcm (2011).
    • (2011)
  • 61
    • 69649086459 scopus 로고    scopus 로고
    • A solid-state hyperspectral imager for real time standoff explosives detection using shortwave infrared imaging
    • 731004-1
    • Onat, B.M., Carver, G. Itzler, M. (2009). A solid-state hyperspectral imager for real time standoff explosives detection using shortwave infrared imaging. Proc. SPIE, 7310, 731004-1.
    • (2009) Proc. SPIE , vol.7310
    • Onat, B.M.1    Carver, G.2    Itzler, M.3
  • 63
    • 77950946225 scopus 로고    scopus 로고
    • Review: Applications of single-shot laser-induced breakdown spectroscopy
    • Michel, A.P.M. (2010). Review: Applications of single-shot laser-induced breakdown spectroscopy. Spectrochim. Acta B, 65, 185-191.
    • (2010) Spectrochim. Acta B , vol.65 , pp. 185-191
    • Michel, A.P.M.1
  • 64
    • 78651285201 scopus 로고    scopus 로고
    • The development of field able laser-induced breakdown spectrometer: No limits on the horizon
    • Fortes, F.J., Laserna, J.J. (2010). The development of field able laser-induced breakdown spectrometer: No limits on the horizon. Spectrochim. Acta B, 65, 975-990.
    • (2010) Spectrochim. Acta B , vol.65 , pp. 975-990
    • Fortes, F.J.1    Laserna, J.J.2
  • 65
    • 68949212291 scopus 로고    scopus 로고
    • Laser-induced breakdown spectroscopy for detection of explosives residues: A review of recent advances, challenges, and future prospects
    • Gottfried, J.L., De Lucia, Jr F.C., Munson, C.A., Miziolek, A.W. (2009). Laser-induced breakdown spectroscopy for detection of explosives residues: a review of recent advances, challenges, and future prospects. Anal. Bioanal. Chem., 395, 283-300.
    • (2009) Anal. Bioanal. Chem , vol.395 , pp. 283-300
    • Gottfried, J.L.1    de Lucia Jr, F.C.2    Munson, C.A.3    Miziolek, A.W.4
  • 66
    • 84861588004 scopus 로고    scopus 로고
    • Optical multi-sensor metrology for extruded profiles
    • Weckenmann, A., Bernstein, J. (2010). Optical multi-sensor metrology for extruded profiles. Metrology and Measurement Systems, 17(1), 47-54.
    • (2010) Metrology and Measurement Systems , vol.17 , Issue.1 , pp. 47-54
    • Weckenmann, A.1    Bernstein, J.2
  • 67
    • 72249104499 scopus 로고    scopus 로고
    • Analysis of explosive and other residues by laser induced breakdown spectroscopy
    • Lazic, V., Palucci, A., Jovicevic, S., Poggi, C., Buono, E. (2009). Analysis of explosive and other residues by laser induced breakdown spectroscopy. Spectrochim. Acta B, 64, 1028-1039.
    • (2009) Spectrochim. Acta B , vol.64 , pp. 1028-1039
    • Lazic, V.1    Palucci, A.2    Jovicevic, S.3    Poggi, C.4    Buono, E.5
  • 68
    • 79651472498 scopus 로고    scopus 로고
    • New challenges and insights in the detection and spectral identification of organic explosives by laser induced breakdown spectroscopy
    • Lucena, P., Dona, A., Tobaria, L.M., Laserna, J.J. (2011). New challenges and insights in the detection and spectral identification of organic explosives by laser induced breakdown spectroscopy. Spectrochim. Acta B, 66, 12-20.
    • (2011) Spectrochim. Acta B , vol.66 , pp. 12-20
    • Lucena, P.1    Dona, A.2    Tobaria, L.M.3    Laserna, J.J.4
  • 69
    • 80052902935 scopus 로고    scopus 로고
    • Detection of explosives in traces by laser induced breakdown spectroscopy: Differences from organic interferents and conditions for a correct classification
    • Lazic, V., Palucci, A., Jovicevic, S., Carpanese, M. (2011). Detection of explosives in traces by laser induced breakdown spectroscopy: Differences from organic interferents and conditions for a correct classification. Spectrochim. Acta B, 66, 644-655.
    • (2011) Spectrochim. Acta B , vol.66 , pp. 644-655
    • Lazic, V.1    Palucci, A.2    Jovicevic, S.3    Carpanese, M.4
  • 70
    • 77953239534 scopus 로고    scopus 로고
    • Characterization of a series of nitrogen-rich molecules using laser-induced breakdown spectroscopy
    • De Lucia, Jr F.C., Gottfried, J.L. (2010). Characterization of a series of nitrogen-rich molecules using laser-induced breakdown spectroscopy. Propellants Explos. Pyrotech., 35, 268-277.
    • (2010) Propellants Explos. Pyrotech , vol.35 , pp. 268-277
    • de Lucia Jr, F.C.1    Gottfried, J.L.2
  • 71
    • 77951613135 scopus 로고    scopus 로고
    • A study of the composition of the products of laser-induced breakdown of hexogen, octogen, pentrite and trinitrotoluene using selected ion flow tube mass spectrometry and UV-VIS spectrometry
    • Sovova, K., Dryahina, K., Spanel, P., Kyncl, M., Civis, S. (2010). A study of the composition of the products of laser-induced breakdown of hexogen, octogen, pentrite and trinitrotoluene using selected ion flow tube mass spectrometry and UV-VIS spectrometry. Analyst, 135, 1106-1114.
    • (2010) Analyst , vol.135 , pp. 1106-1114
    • Sovova, K.1    Dryahina, K.2    Spanel, P.3    Kyncl, M.4    Civis, S.5
  • 72
    • 0034743029 scopus 로고    scopus 로고
    • Determination of C:H:O:N ratios in solid organic compounds by laser-induced plasma spectroscopy
    • Tran, M., Sun, Q., Smith, B.W., Winefordner, J.D. (2001). Determination of C:H:O:N ratios in solid organic compounds by laser-induced plasma spectroscopy. J. Anal. At. Spectrom., 16, 628-632.
    • (2001) J. Anal. At. Spectrom , vol.16 , pp. 628-632
    • Tran, M.1    Sun, Q.2    Smith, B.W.3    Winefordner, J.D.4
  • 73
    • 61349083124 scopus 로고    scopus 로고
    • Discrimination of explosive residues on organic and inorganic substrates using laser-induced breakdown spectroscopy
    • Gottfried, J.L., De Lucia, Jr F.C., Miziolek, A.W. (2009). Discrimination of explosive residues on organic and inorganic substrates using laser-induced breakdown spectroscopy. J. Anal. At. Spectrom., 24, 288-296.
    • (2009) J. Anal. At. Spectrom , vol.24 , pp. 288-296
    • Gottfried, J.L.1    de Lucia Jr, F.C.2    Miziolek, A.W.3
  • 75
    • 79960154720 scopus 로고    scopus 로고
    • Discrimination of organic solid materials by LIBS using methods of correlation and normalized coordinates
    • Lasheras, R.J., Bello-Galvez, C., Rodriguez-Celis, E.M., Anzano, J. (2011). Discrimination of organic solid materials by LIBS using methods of correlation and normalized coordinates. J. Hazard. Mat., 192, 704-713.
    • (2011) J. Hazard. Mat , vol.192 , pp. 704-713
    • Lasheras, R.J.1    Bello-Galvez, C.2    Rodriguez-Celis, E.M.3    Anzano, J.4
  • 77
    • 58449120867 scopus 로고    scopus 로고
    • Multivariate analysis of standoff laser-induced breakdown spectroscopy spectra for classification of explosive-containing residues
    • De Lucia, Jr F.C., Gottfried, J.L., Munson, C.A., Miziolek, A.W. (2008). Multivariate analysis of standoff laser-induced breakdown spectroscopy spectra for classification of explosive-containing residues. Appl. Opt., 47, G112-G120.
    • (2008) Appl. Opt , vol.47
    • de Lucia Jr, F.C.1    Gottfried, J.L.2    Munson, C.A.3    Miziolek, A.W.4
  • 78
    • 58149185046 scopus 로고    scopus 로고
    • Multivariate analysis of remote laser-induced breakdown spectroscopy spectra using partial least squares, principal component analysis, and related techniques
    • Clegg, S.M., Sklute, E., DarbyDyare, M., Barefield, J.E., Wiens, R.C. (2009). Multivariate analysis of remote laser-induced breakdown spectroscopy spectra using partial least squares, principal component analysis, and related techniques. Spectrochim. Acta B, 64, 79-88.
    • (2009) Spectrochim. Acta B , vol.64 , pp. 79-88
    • Clegg, S.M.1    Sklute, E.2    Darby Dyare, M.3    Barefield, J.E.4    Wiens, R.C.5
  • 79
    • 76349118755 scopus 로고    scopus 로고
    • Laser-induced breakdown spectroscopy with artificial neural network processing for material identification
    • Koujelev, A., Sabsabi, M., Motto-Ros, V., Laville, S., Lui, S.L. (2010). Laser-induced breakdown spectroscopy with artificial neural network processing for material identification. Planet. Space Sci., 58, 682-690.
    • (2010) Planet. Space Sci , vol.58 , pp. 682-690
    • Koujelev, A.1    Sabsabi, M.2    Motto-Ros, V.3    Laville, S.4    Lui, S.L.5
  • 81
    • 71549133693 scopus 로고    scopus 로고
    • A combined laser-induced breakdown and Raman spectroscopy Echelle system for elemental and molecular microanalysis
    • Hoehse, M., Mory, D., Florek, S., Weritz, F., Gornushkin, I., Panne, U. (2009). A combined laser-induced breakdown and Raman spectroscopy Echelle system for elemental and molecular microanalysis. Spectrochim. Acta B, 64, 1219-1227.
    • (2009) Spectrochim. Acta B , vol.64 , pp. 1219-1227
    • Hoehse, M.1    Mory, D.2    Florek, S.3    Weritz, F.4    Gornushkin, I.5    Panne, U.6
  • 82
    • 78650489680 scopus 로고    scopus 로고
    • Thermal Microwave Radiation for Subsurface Absolute Temperature Measurement
    • Susek, W. (2010). Thermal Microwave Radiation for Subsurface Absolute Temperature Measurement. Acta Physica Polonica A, 118, 6, 1246-1249.
    • (2010) Acta Physica Polonica A , vol.118 , Issue.6 , pp. 1246-1249
    • Susek, W.1
  • 88
    • 80052488489 scopus 로고    scopus 로고
    • Explosives Detection by Terahertz Spectroscopy-A Bridge Too Far?
    • Kemp, M.C. (2011). Explosives Detection by Terahertz Spectroscopy-A Bridge Too Far? IEEE Transactions on Terahertz Science and Technology, 1, 282-292.
    • (2011) IEEE Transactions on Terahertz Science and Technology , vol.1 , pp. 282-292
    • Kemp, M.C.1
  • 90
    • 80053414379 scopus 로고    scopus 로고
    • THz reflection spectroscopy of explosives measured by Time Domain Spectroscopy
    • Palka, N. (2011). THz reflection spectroscopy of explosives measured by Time Domain Spectroscopy. Acta Physica Polonica A, 120(4), 713-715.
    • (2011) Acta Physica Polonica A , vol.120 , Issue.4 , pp. 713-715
    • Palka, N.1
  • 92
    • 84858676637 scopus 로고    scopus 로고
    • http://www.ipm.fraunhofer.de
  • 93
    • 84858648468 scopus 로고    scopus 로고
    • http://www.teledyne-ai.com/pdf/lga-3500.pdf
  • 94
    • 0003202688 scopus 로고    scopus 로고
    • Cavity-Ringdown Spectroscopy, An Ultratrace-Absorption Measurement Technique
    • Washington DC
    • Busch, K.W., Busch, M.A. (1999). Cavity-Ringdown Spectroscopy, An Ultratrace-Absorption Measurement Technique. ACS Symposium series, Washington DC.
    • (1999) ACS Symposium series
    • Busch, K.W.1    Busch, M.A.2
  • 95
    • 0034536080 scopus 로고    scopus 로고
    • Cavity ring-down spectroscopy. Experimental schemes and applications
    • Berden, G., Peeters, R., Meijer, G. (2000). Cavity ring-down spectroscopy. Experimental schemes and applications. Int. Rev. Phys. Chem., 19(4), 565-607.
    • (2000) Int. Rev. Phys. Chem , vol.19 , Issue.4 , pp. 565-607
    • Berden, G.1    Peeters, R.2    Meijer, G.3
  • 96
    • 0038381863 scopus 로고    scopus 로고
    • Cavityenhanced absorption: Detection of nitrogen dioxide and iodine monoxide using a violet laser diode
    • Kasyutich, V.L., Bale, C.S.E., Canosa-Mas, C.E., Pfrang, C., Vaughan, S., Wayne, R.P. (2003). Cavityenhanced absorption: detection of nitrogen dioxide and iodine monoxide using a violet laser diode. Appl. Phys. B, 76(6), 691-698.
    • (2003) Appl. Phys. B , vol.76 , Issue.6 , pp. 691-698
    • Kasyutich, V.L.1    Bale, C.S.E.2    Canosa-Mas, C.E.3    Pfrang, C.4    Vaughan, S.5    Wayne, R.P.6
  • 97
    • 84858648465 scopus 로고    scopus 로고
    • Detection of optical radiation in NOx optoelectronic sensors employing cavity enhanced absorption spectroscopy
    • Intech Publishers, Vienna, Austria, ISBN 978-953-307-576-1
    • Wojtas, J. (2011). Detection of optical radiation in NOx optoelectronic sensors employing cavity enhanced absorption spectroscopy. Chapter in Optoelectronics-Devices and Applications, Intech Publishers, Vienna, Austria, ISBN 978-953-307-576-1, 147-172.
    • (2011) Chapter in Optoelectronics-Devices and Applications , pp. 147-172
    • Wojtas, J.1
  • 98
    • 38549179324 scopus 로고    scopus 로고
    • Sensitive detection of NO2 with Cavity Enhanced Spectroscopy
    • Wojtas, J., Czyzewski, A., Stacewicz, T., Bielecki, Z. (2006). Sensitive detection of NO2 with Cavity Enhanced Spectroscopy. Optica Applicata, 36(4), 461-467.
    • (2006) Optica Applicata , vol.36 , Issue.4 , pp. 461-467
    • Wojtas, J.1    Czyzewski, A.2    Stacewicz, T.3    Bielecki, Z.4
  • 99
    • 53149128701 scopus 로고    scopus 로고
    • Signal processing system in the cavity enhanced spectroscopy
    • Wojtas, J., Bielecki, Z. (2008). Signal processing system in the cavity enhanced spectroscopy. Opto-Electron. Rev., 16(4), 44-51.
    • (2008) Opto-Electron. Rev , vol.16 , Issue.4 , pp. 44-51
    • Wojtas, J.1    Bielecki, Z.2
  • 104
    • 0029521989 scopus 로고
    • Explosive detection: Potential problems
    • Oxley, J.C. (1995). Explosive detection: potential problems. Proc. SPIE, 2511, 217-225.
    • (1995) Proc. SPIE , vol.2511 , pp. 217-225
    • Oxley, J.C.1
  • 105
    • 46649100684 scopus 로고    scopus 로고
    • Optical interferometric structures for application in gas sensors
    • Pustelny, T., Maciak, E., Opilski, Z., Bednorz, M. (2007). Optical interferometric structures for application in gas sensors, Optica Applicata, 37(102), 187-194.
    • (2007) Optica Applicata , vol.37 , Issue.102 , pp. 187-194
    • Pustelny, T.1    Maciak, E.2    Opilski, Z.3    Bednorz, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.