메뉴 건너뛰기




Volumn 46, Issue 2, 2012, Pages 145-149

Results of a new human recombinant thrombin for the treatment of arterial pseudoaneurysm

Author keywords

pseudoaneurysm; recombinant thrombin; treatment

Indexed keywords

ACETYLSALICYLIC ACID; ANTICOAGULANT AGENT; ANTITHROMBOCYTIC AGENT; CLOPIDOGREL; HEPARIN; LOW MOLECULAR WEIGHT HEPARIN; RECOMBINANT THROMBIN;

EID: 84858404763     PISSN: 15385744     EISSN: 19389116     Source Type: Journal    
DOI: 10.1177/1538574411431346     Document Type: Review
Times cited : (6)

References (17)
  • 3
    • 7244247058 scopus 로고    scopus 로고
    • Prospective randomized study comparing ultrasound-guided thrombin injection to compression in the treatment of femoral pseudoaneurysms
    • DOI 10.1583/03-1181.1
    • Lonn L, Olmarker A, Geterud K, Risberg B.. Prospective randomized study comparing ultrasound-guided thrombin injection to compression in the treatment of femoral pseudoaneurysms. J Endovasc Ther. 2004 ; 11 (5). 570-576 (Pubitemid 39435086)
    • (2004) Journal of Endovascular Therapy , vol.11 , Issue.5 , pp. 570-576
    • Lonn, L.1    Olmarker, A.2    Geterud, K.3    Risberg, B.4
  • 4
    • 0035752656 scopus 로고    scopus 로고
    • Comparison of the FemoStop device and manual pressure in reducing groin puncture site complications following coronary angioplasty and coronary stent placement
    • Walker SB, Cleary S, Higgins M.. Comparison of the FemoStop device and manual pressure in reducing groin puncture site complications following coronary angioplasty and coronary stent placement. Int J Nurs Pract. 2001 ; 7 (6). 366-375
    • (2001) Int J Nurs Pract , vol.7 , Issue.6 , pp. 366-375
    • Walker, S.B.1    Cleary, S.2    Higgins, M.3
  • 5
    • 33644751858 scopus 로고    scopus 로고
    • An evaluation of immediate sheath removal and use of the Angio-Seal vascular closure device in neuroradiological interventions
    • DOI 10.1007/s00234-005-0013-8
    • Pierot L, Herbreteau D, Bracard S, Berge J, Cognard C.. An evaluation of immediate sheath removal and use of the Angio-Seal vascular closure device in neuroradiological interventions. Neuroradiology. 2006 ; 48 (1). 45-49 (Pubitemid 43336692)
    • (2006) Neuroradiology , vol.48 , Issue.1 , pp. 45-49
    • Pierot, L.1    Herbreteau, D.2    Bracard, S.3    Berge, J.4    Cognard, C.5
  • 6
    • 27744558395 scopus 로고    scopus 로고
    • Applications of fibrin sealant in surgery
    • DOI 10.1177/155335060501200304
    • Lee MG, Jones D.. Applications of fibrin sealant in surgery. Surg Innov. 2005 ; 12 (3). 203-213 (Pubitemid 41614523)
    • (2005) Surgical Innovation , vol.12 , Issue.3 , pp. 203-213
    • Lee, M.-G.M.1    Jones, D.2
  • 10
    • 0031837138 scopus 로고    scopus 로고
    • Percutaneous ultrasound guided thrombin injection: A new method for treating postcatheterization femoral pseudoaneurysms
    • DOI 10.1016/S0741-5214(98)70006-0
    • Kang SS, Labropoulos N, Mansour MA, Baker WH.. Percutaneous ultrasound guided thrombin injection: a new method for treating postcatheterization femoral pseudoaneurysms. J Vasc Surg. 1998 ; 27 (6). 1032-1038 (Pubitemid 28289891)
    • (1998) Journal of Vascular Surgery , vol.27 , Issue.6 , pp. 1032-1038
    • Kang, S.S.1    Labropoulos, N.2    Mansour, M.A.3    Baker, W.H.4    Darling III, R.C.5
  • 11
    • 33645532617 scopus 로고    scopus 로고
    • Surgery versus non-surgical treatment for femoral pseudoaneurysms
    • Tisi PV, Callam MJ.. Surgery versus non-surgical treatment for femoral pseudoaneurysms. Cochrane Database Syst Rev. 2006 ; ( 1 ):
    • (2006) Cochrane Database Syst Rev , Issue.1
    • Tisi, P.V.1    Callam, M.J.2
  • 12
    • 0036779836 scopus 로고    scopus 로고
    • A prospective study of ultrasound scan-guided thrombin injection of femoral pseudoaneurysm: A trend toward minimal medication
    • DOI 10.1067/mva.2002.127967
    • Olsen DM, Rodriguez JA, Vranic M, Ramaiah V, Ravi R, Diethrich EB.. A prospective study of ultrasound scan-guided thrombin injection of femoral pseudoaneurysm: a trend toward minimal medication. J Vasc Surg. 2002 ; 36 (4). 779-782 (Pubitemid 41122976)
    • (2002) Journal of Vascular Surgery , vol.36 , Issue.4 , pp. 779-782
    • Olsen, D.M.1    Rodriguez, J.A.2    Vranic, M.3    Ramaiah, V.4    Ravi, R.5    Diethrich, E.B.6
  • 15
    • 0142095192 scopus 로고    scopus 로고
    • Iatrogenic Femoral Pseudoaneurysms That Are Unresponsive to Percutaneous Thrombin Injection: Potential Causes
    • Sheiman RG, Mastromatteo M.. Iatrogenic femoral pseudoaneurysms that are unresponsive to percutaneous thrombin injection: potential causes. AJR Am J Roentgenol. 2003 ; 181 (5). 1301-1304 (Pubitemid 37296406)
    • (2003) American Journal of Roentgenology , vol.181 , Issue.5 , pp. 1301-1304
    • Sheiman, R.G.1    Mastromatteo, M.2
  • 16
    • 42749087004 scopus 로고    scopus 로고
    • Acute arterial occlusion after ultrasound-guided thrombin injection of a common femoral artery pseudoaneurysm with a wide, short neck
    • D'Ayala M, Smith R, Zanieski G, Fahoum B, Tortolani AJ.. Acute arterial occlusion after ultrasound-guided thrombin injection of a common femoral artery pseudoaneurysm with a wide, short neck. Ann Vasc Surg. 2008 ; 22 (3). 473-475
    • (2008) Ann Vasc Surg , vol.22 , Issue.3 , pp. 473-475
    • D'Ayala, M.1    Smith, R.2    Zanieski, G.3    Fahoum, B.4    Tortolani, A.J.5
  • 17
    • 74749097855 scopus 로고    scopus 로고
    • Safety and immunogenicity observations pooled from eight clinical trials of recombinant human thrombin
    • Ballard JL, Weaver FA, Singla NK, Chapman WC, Alexander WA.. Safety and immunogenicity observations pooled from eight clinical trials of recombinant human thrombin. J Am Coll Surg. 2010 ; 210 (2). 199-204
    • (2010) J Am Coll Surg , vol.210 , Issue.2 , pp. 199-204
    • Ballard, J.L.1    Weaver, F.A.2    Singla, N.K.3    Chapman, W.C.4    Alexander, W.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.