-
1
-
-
0142087597
-
Sustained effect of intensive treatment of type 1 diabetes mellitus on development and progression of diabetic retinopathy: The Epidemiology of Diabetes Interventions and Complications (EDIC) Study
-
Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Research Group
-
Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Research Group. Sustained effect of intensive treatment of type 1 diabetes mellitus on development and progression of diabetic retinopathy: the Epidemiology of Diabetes Interventions and Complications (EDIC) Study. JAMA 2003; 290:2159-2167.
-
(2003)
JAMA
, vol.290
, pp. 2159-2167
-
-
-
2
-
-
71749092532
-
Glycemic control in youth with diabetes: The SEARCH for diabetes in Youth Study
-
Pettiti DB, Klingensmith GJ, Bell RA, et al. Glycemic control in youth with diabetes: the SEARCH for diabetes in Youth Study. J Pediatr 2009; 155:668-672.
-
(2009)
J Pediatr
, vol.155
, pp. 668-672
-
-
Pettiti, D.B.1
Klingensmith, G.J.2
Bell, R.A.3
-
3
-
-
0016185358
-
Clinical control of diabetes by the artificial pancreas
-
Albisser AM, Leibel BS, Ewart TG, et al. Clinical control of diabetes by the artificial pancreas. Diabetes 1974; 23:397-404.
-
(1974)
Diabetes
, vol.23
, pp. 397-404
-
-
Albisser, A.M.1
Leibel, B.S.2
Ewart, T.G.3
-
4
-
-
0017338283
-
The development of Biostator, a Glucose Controlled Insulin Infusion System (GCIIS)
-
Clemens AH, Chang PH, Myers RW. The development of Biostator, a Glucose Controlled Insulin Infusion System (GCIIS). Horm Metab Res 1977; Suppl 7:23-33
-
(1977)
Horm Metab Res
, Issue.SUPPL. 7
, pp. 23-33
-
-
Clemens, A.H.1
Chang, P.H.2
Myers, R.W.3
-
5
-
-
54849147700
-
Continuous glucose monitoring and intensive treatment of type 1 diabetes
-
JDRF CGM Study Group
-
JDRF CGM Study Group. Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 2008; 359:1464-1476.
-
(2008)
N Engl J Med
, vol.359
, pp. 1464-1476
-
-
-
6
-
-
70449378190
-
Factors predictive of use and of benefit from continuous glucose monitoring in type 1 diabetes
-
JDRF CGM Study Group
-
JDRF CGM Study Group. Factors predictive of use and of benefit from continuous glucose monitoring in type 1 diabetes. Diabetes Care 2009; 32:1947-1953.
-
(2009)
Diabetes Care
, vol.32
, pp. 1947-1953
-
-
-
7
-
-
77954830051
-
Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes
-
The largest and longest clinical trial of sensor-augmented pump therapy to date (485 adults and children with type 1 diabtes studied for 1 year) demonstrated superiority of insulin pumps and continuous glucose monitoring to multiple daily injection regimens and routine blood glucose monitoring
-
Bergenstal RM, Tamborlane WV, Ahmann A, et al. Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med 2010; 363:311-320. The largest and longest clinical trial of sensor-augmented pump therapy to date (485 adults and children with type 1 diabtes studied for 1 year) demonstrated superiority of insulin pumps and continuous glucose monitoring to multiple daily injection regimens and routine blood glucose monitoring.
-
(2010)
N Engl J Med
, vol.363
, pp. 311-320
-
-
Bergenstal, R.M.1
Tamborlane, W.V.2
Ahmann, A.3
-
8
-
-
84856407738
-
Effectiveness of sensor-augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study
-
The pediatric cohort of the STAR3 clinical trial demonstrated improvement in A1c, reduction in hyperglycemic exposure, and reduction in glycemic variability using sensor-augmented pump therapy compared with multiple daily injections with routine glucose monitoring
-
Slover RH, Welsh JB, Criego A, et al. Effectiveness of sensor-augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study. Pediatr Diabetes 2012; 13:6-11. The pediatric cohort of the STAR3 clinical trial demonstrated improvement in A1c, reduction in hyperglycemic exposure, and reduction in glycemic variability using sensor-augmented pump therapy compared with multiple daily injections with routine glucose monitoring.
-
(2012)
Pediatr Diabetes
, vol.13
, pp. 6-11
-
-
Slover, R.H.1
Welsh, J.B.2
Criego, A.3
-
9
-
-
84873075493
-
A randomized clinical trial to assess the efficacy and safety of real-time continuous glucose monitoring in the management of type 1 diabetes in young children (4 to <10 year DLDs)
-
Diabetes Research in Children Network Study Group. (in press)
-
Diabetes Research in Children Network Study Group. A randomized clinical trial to assess the efficacy and safety of real-time continuous glucose monitoring in the management of type 1 diabetes in young children (4 to <10 year DLDs). Diabetes Care (in press).
-
Diabetes Care
-
-
-
10
-
-
84858287882
-
Feasibility of continuous glucose monitoring in infants and toddlers with type 1 diabetes
-
Diabetes Research in Children Network Study Group
-
Diabetes Research in Children Network Study Group. Feasibility of continuous glucose monitoring in infants and toddlers with type 1 diabetes. Diabetes 2011; 60 (Supp 1):A335.
-
(2011)
Diabetes
, vol.60
, Issue.SUPPL. 1
-
-
-
11
-
-
0027998781
-
Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: Diabetes Control and Complications Trial
-
Diabetes Control and Complications Trial Research Group
-
Diabetes Control and Complications Trial Research Group. Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: Diabetes Control and Complications Trial. J Pediatr 1994; 125:177-188.
-
(1994)
J Pediatr
, vol.125
, pp. 177-188
-
-
-
12
-
-
0030840380
-
Incidence and predictive criteria of nocturnal hypoglycemia in young children with insulin-dependent diabetes mellitus
-
DOI 10.1016/S0022-3476(97)70197-5
-
Porter PA, Keating B, Byrne G, Jones TW. Incidence and predictive criteria of nocturnal hypoglycemia in young children with insulin-dependent diabetes mellitus. J Pediatr 1997; 130:366-372. (Pubitemid 27492679)
-
(1997)
Journal of Pediatrics
, vol.130
, Issue.3
, pp. 366-372
-
-
Porter, P.A.1
Keating, B.2
Byrne, G.3
Jones, T.W.4
-
13
-
-
0032482390
-
Decreased epinephrine responses to hypoglycemia during sleep
-
DOI 10.1056/NEJM199806043382303
-
Jones TW, Porter P, Sherwin RS, et al. Decreased epinephrine responses to hypoglycemia during sleep. N Engl J Med 1998; 338:1657-1662. (Pubitemid 28267910)
-
(1998)
New England Journal of Medicine
, vol.338
, Issue.23
, pp. 1657-1662
-
-
Jones, T.W.1
Porter, P.2
Sherwin, R.S.3
Davis, E.A.4
O'Leary, P.5
Frazer, F.6
Byrne, G.7
Stick, S.8
Tamborlane, W.V.9
-
14
-
-
20544452543
-
Response to nocturnal alarms using a real-time glucose sensor
-
Buckingham B, Block J, Burdick J, et al. Response to nocturnal alarms using a real-time glucose sensor. Diabetes Technol Ther 2005; 7:440-447.
-
(2005)
Diabetes Technol Ther
, vol.7
, pp. 440-447
-
-
Buckingham, B.1
Block, J.2
Burdick, J.3
-
15
-
-
59249094292
-
Duration of nocturnal hypoglycemia prior to seizures
-
Buckingham B, Wilson DM, Lecher T, et al. Duration of nocturnal hypoglycemia prior to seizures. Diabetes Care 2008; 31:2110-2112.
-
(2008)
Diabetes Care
, vol.31
, pp. 2110-2112
-
-
Buckingham, B.1
Wilson, D.M.2
Lecher, T.3
-
16
-
-
84857423158
-
Usage and effectiveness of the low glucose suspend feature of the Medtronic Paradigm Veo insulin pump
-
Data from over 900 patients over almost 50 000 patient-days of real-world use in the ambulatory setting provides compelling evidence for the safety and efficacy of sensor-augmented pump therapy with a low-glucose suspend feature: hypoglycemia was reduced without a deterioration in overall glucose control
-
Agrawal P, Welsh JB, Kannard B, et al. Usage and effectiveness of the low glucose suspend feature of the Medtronic Paradigm Veo insulin pump. J Diabetes Sci Technol 2011; 5:1137-1141. Data from over 900 patients over almost 50 000 patient-days of real-world use in the ambulatory setting provides compelling evidence for the safety and efficacy of sensor-augmented pump therapy with a low-glucose suspend feature: hypoglycemia was reduced without a deterioration in overall glucose control.
-
(2011)
J Diabetes Sci Technol
, vol.5
, pp. 1137-1141
-
-
Agrawal, P.1
Welsh, J.B.2
Kannard, B.3
-
17
-
-
82555164135
-
Insulin pump therapy with automated insulin suspension in response to hypoglycemia: Reduction in nocturnal hypoglycemia in those at greatest risk
-
Choudhary P, Shin J, Wang Y, et al. Insulin pump therapy with automated insulin suspension in response to hypoglycemia: reduction in nocturnal hypoglycemia in those at greatest risk. Diabetes Care 2011; 34:2023-2025.
-
(2011)
Diabetes Care
, vol.34
, pp. 2023-2025
-
-
Choudhary, P.1
Shin, J.2
Wang, Y.3
-
18
-
-
80055028578
-
Prevention of hypoglycemia by using low glucose suspend function in sensor-augmented pump therapy
-
A crossover study of sensor-augmented pump therapy with low-glucose suspend feature in 21 children with type 1 diabetes demonstrated efficacy (reduction of hypoglycemia episodes and time spent in hypoglycemia) and safety (no deterioration in average glucose levels) over a 6-week course
-
Danne T, Kordonouri O, Holder M, et al. Prevention of hypoglycemia by using low glucose suspend function in sensor-augmented pump therapy. Diabetes Technol Ther 2011; 13:1129-1134. A crossover study of sensor-augmented pump therapy with low-glucose suspend feature in 21 children with type 1 diabetes demonstrated efficacy (reduction of hypoglycemia episodes and time spent in hypoglycemia) and safety (no deterioration in average glucose levels) over a 6-week course.
-
(2011)
Diabetes Technol Ther
, vol.13
, pp. 1129-1134
-
-
Danne, T.1
Kordonouri, O.2
Holder, M.3
-
19
-
-
77955652578
-
Real-Time hypoglycemia prediction suite using continuous glucose monitoring: A safety net for the artificial pancreas
-
Dassau E, Cameron F, Lee H, et al. Real-Time hypoglycemia prediction suite using continuous glucose monitoring: a safety net for the artificial pancreas. Diabetes Care 2010; 33:1249-1254.
-
(2010)
Diabetes Care
, vol.33
, pp. 1249-1254
-
-
Dassau, E.1
Cameron, F.2
Lee, H.3
-
20
-
-
77954939888
-
Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension
-
Using an array of five different prediction algorithms and a voting scheme to suspend basal insulin delivery when a predetermined number of algorithms predicted incipient hypoglycemia, this study demonstrated prevention of up to 75% of hypoglycemic episodes
-
Buckingham B, Chase HP, Dassau E, et al. Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension. Diabetes Care 2010; 33:1013-1017. Using an array of five different prediction algorithms and a voting scheme to suspend basal insulin delivery when a predetermined number of algorithms predicted incipient hypoglycemia, this study demonstrated prevention of up to 75% of hypoglycemic episodes.
-
(2010)
Diabetes Care
, vol.33
, pp. 1013-1017
-
-
Buckingham, B.1
Chase, H.P.2
Dassau, E.3
-
21
-
-
58449094833
-
Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension
-
Buckingham B, Cobry E, Clinton P, et al. Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension. Diabetes Technol Ther 2009; 11:93-97.
-
(2009)
Diabetes Technol Ther
, vol.11
, pp. 93-97
-
-
Buckingham, B.1
Cobry, E.2
Clinton, P.3
-
22
-
-
38949150087
-
Detection of a meal using continuous glucose monitoring: Implications for an artificial beta-cell
-
DOI 10.2337/dc07-1293
-
Dassau E, Bequette BW, Buckingham BA, Doyle FJ 3rd. Detection of a meal using continuous glucose monitoring: implications for an artificial beta-cell. Diabetes Care 2008; 31:295-300. (Pubitemid 351213339)
-
(2008)
Diabetes Care
, vol.31
, Issue.2
, pp. 295-300
-
-
Dassau, E.1
Bequette, B.W.2
Buckingham, B.A.3
Doyle III, F.J.4
-
23
-
-
77953039088
-
Control to range for diabetes: Functionality and modular architecture
-
Kovatchev B, Patek S, Dassau E, et al. Control to range for diabetes: functionality and modular architecture. J Diabetes Sci Technol 2009; 3:1058-1065.
-
(2009)
J Diabetes Sci Technol
, vol.3
, pp. 1058-1065
-
-
Kovatchev, B.1
Patek, S.2
Dassau, E.3
-
24
-
-
0347624612
-
Modeling beta-Cell Insulin Secretion - Implications for Closed-Loop Glucose Homeostasis
-
DOI 10.1089/152091503322640999
-
Steil GM, Rebrin K, Janowski R, et al. Modeling beta-cell insulin secretion: implications for closed-loop glucose homeostasis. Diabetes Technol Ther 2003; 5:953-964. (Pubitemid 38009933)
-
(2003)
Diabetes Technology and Therapeutics
, vol.5
, Issue.6
, pp. 953-964
-
-
Steil, G.M.1
Rebrin, K.2
Janowski, R.3
Darwin, C.4
Saad, M.F.5
-
25
-
-
1642452596
-
Closed-loop insulin delivery - The path to physiological glucose control
-
DOI 10.1016/j.addr.2003.08.011
-
Steil GM, Panteleon AE, Rebrin K. Closed-loop insulin delivery-the path to physiological glucose control. Adv Drug Deliv Rev 2004; 56:125-144. (Pubitemid 38114927)
-
(2004)
Advanced Drug Delivery Reviews
, vol.56
, Issue.2
, pp. 125-144
-
-
Steil, G.M.1
Panteleon, A.E.2
Rebrin, K.3
-
26
-
-
4344640337
-
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
-
DOI 10.1088/0967-3334/25/4/010, PII S0967333404802442
-
Hovorka R, Canonico V, Chassin LJ, et al. Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes. Physiol Meas 2004; 25:905-920. (Pubitemid 39121173)
-
(2004)
Physiological Measurement
, vol.25
, Issue.4
, pp. 905-920
-
-
Hovorka, R.1
Canonico, V.2
Chassin, L.J.3
Haueter, U.4
Massi-Benedetti, M.5
Federici, M.O.6
Pieber, T.R.7
Schaller, H.C.8
Schaupp, L.9
Vering, T.10
Wilinska, M.E.11
-
27
-
-
67650850418
-
Model predictive control of type 1 diabetes: An in silico trial
-
Magni L, Raimondo DM, Bossi L, et al. Model predictive control of type 1 diabetes: an in silico trial. J Diabetes Sci Technol 2007; 1:804-812.
-
(2007)
J Diabetes Sci Technol
, vol.1
, pp. 804-812
-
-
Magni, L.1
Raimondo, D.M.2
Bossi, L.3
-
28
-
-
0032962321
-
A model-based algorithm for blood glucose control in type I diabetic patients
-
DOI 10.1109/10.740877
-
Parker RS, Doyle FJ, Peppas NA. A model-based algorithm for blood glucose control in type 1 diabetic patients. IEEE Trans Biomed Eng 1999; 46:148-157. (Pubitemid 29058920)
-
(1999)
IEEE Transactions on Biomedical Engineering
, vol.46
, Issue.2
, pp. 148-157
-
-
Parker, R.S.1
Doyle, F.J.2
Peppas, N.A.3
-
29
-
-
78049498460
-
Zone model predictive control: A strategy to minimize hyper- and hypoglycemic events
-
Grosman B, Dassau E, Zisser HC, et al. Zone model predictive control: a strategy to minimize hyper- and hypoglycemic events. J Diabetes Sci Technol 2010; 4:961-975.
-
(2010)
J Diabetes Sci Technol
, vol.4
, pp. 961-975
-
-
Grosman, B.1
Dassau, E.2
Zisser, H.C.3
-
30
-
-
78049505191
-
Proposed clinical application for tuning fuzzy logic controller of artificial pancreas utilizing a personalization factor
-
Mauseth R, Wang Y, Dassau E, et al. Proposed clinical application for tuning fuzzy logic controller of artificial pancreas utilizing a personalization factor. J Diabetes Sci Technol 2010; 4:913-922.
-
(2010)
J Diabetes Sci Technol
, vol.4
, pp. 913-922
-
-
Mauseth, R.1
Wang, Y.2
Dassau, E.3
-
31
-
-
80053387073
-
Automatic learning algorithm for the MD-logic artificial pancreas system
-
Miller S, Nimri R, Atlas E, et al. Automatic learning algorithm for the MD-logic artificial pancreas system. Diabetes Technol Ther 2011; 13:983-990.
-
(2011)
Diabetes Technol Ther
, vol.13
, pp. 983-990
-
-
Miller, S.1
Nimri, R.2
Atlas, E.3
-
32
-
-
27744588950
-
A novel insulin delivery algorithm in rats with type 1 diabetes: The fading memory proportional-derivative method
-
DOI 10.1111/j.1525-1594.2005.29096.x
-
Gopakumaran B, Duman HM, Overholser DP, et al. A novel insulin delivery algorithm in rats with type 1 diabetes: the fading memory proportional- derivative method. Artif Organs 2005; 29:599-607. (Pubitemid 41602836)
-
(2005)
Artificial Organs
, vol.29
, Issue.8
, pp. 599-607
-
-
Gopakumaran, B.1
Duman, H.M.2
Overholser, D.P.3
Federiuk, I.F.4
Quinn, M.J.5
Wood, M.D.6
Ward, W.K.7
-
33
-
-
77952996672
-
A feasibility study of bihormonal closed-loop blood glucose control using dual subcutaneous infusion of insulin and glucagon in ambulatory diabetic swine
-
El-Khatib FH, Jiang J, Damiano ER. A feasibility study of bihormonal closed-loop blood glucose control using dual subcutaneous infusion of insulin and glucagon in ambulatory diabetic swine. J Diabetes Sci Technol 2009; 3:789-803.
-
(2009)
J Diabetes Sci Technol
, vol.3
, pp. 789-803
-
-
El-Khatib, F.H.1
Jiang, J.2
Damiano, E.R.3
-
34
-
-
33845521334
-
Feasibility of automating insulin delivery for the treatment of type 1 diabetes
-
DOI 10.2337/db06-0419
-
Steil GM, Rebrin K, Darwin C, et al. Feasibility of automating insulin delivery for the treatment of type 1 diabetes. Diabetes 2006; 55:3344-3350. (Pubitemid 44923591)
-
(2006)
Diabetes
, vol.55
, Issue.12
, pp. 3344-3350
-
-
Steil, G.M.1
Rebrin, K.2
Darwin, C.3
Hariri, F.4
Saad, M.F.5
-
35
-
-
48649083317
-
Fully automated closed-loop insulin delivery vs. semi-automated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas
-
Weinzimer SA, Steil GM, Swan KL, et al. Fully automated closed-loop insulin delivery vs. semi-automated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care 2008; 31:934-939.
-
(2008)
Diabetes Care
, vol.31
, pp. 934-939
-
-
Weinzimer, S.A.1
Steil, G.M.2
Swan, K.L.3
-
36
-
-
79955164375
-
Physiologic insulin delivery with insulin feedback: A control systems perspective
-
Epub 2010 Aug 2
-
Palerm CC. Physiologic insulin delivery with insulin feedback: a control systems perspective. Comput Methods Programs Biomed 2011; 102:130-137; Epub 2010 Aug 2.
-
(2011)
Comput Methods Programs Biomed
, vol.102
, pp. 130-137
-
-
Palerm, C.C.1
-
37
-
-
79955670667
-
The effect of insulin feedback on closed loop glucose control
-
Steil GM, Palerm CC, Kurtz N, et al. The effect of insulin feedback on closed loop glucose control. J Clin Endocrinol Metab 2011; 96:1402-1408.
-
(2011)
J Clin Endocrinol Metab
, vol.96
, pp. 1402-1408
-
-
Steil, G.M.1
Palerm, C.C.2
Kurtz, N.3
-
38
-
-
84873061508
-
Effect of insulin feedback algorithm on closed-loop blood glucose control
-
Abstract
-
Ruiz JL, Sherr JL, Cengiz E, et al. Effect of insulin feedback algorithm on closed-loop blood glucose control [Abstract]. Diabetes Technol Soc 2011; A163.
-
(2011)
Diabetes Technol Soc
-
-
Ruiz, J.L.1
Sherr, J.L.2
Cengiz, E.3
-
39
-
-
82555167939
-
Effect of adjuvant injected pramlintide on closed-loop automated insulin delivery
-
Weinzimer SA, Sherr JL, Cengiz E, et al. Effect of adjuvant injected pramlintide on closed-loop automated insulin delivery. Diabetes 2011; 60 (Supp 1):A253.
-
(2011)
Diabetes
, vol.60
, Issue.SUPPL. 1
-
-
Weinzimer, S.A.1
Sherr, J.L.2
Cengiz, E.3
-
40
-
-
84873064107
-
Glucose control using closed loop insulin delivery during nights with or without antecedent afternoon exercise
-
Weinzimer SA, Sherr JL, Cengiz E, et al. Glucose control using closed loop insulin delivery during nights with or without antecedent afternoon exercise. Diabetes 2011; 60 (Supp 1):A42.
-
(2011)
Diabetes
, vol.60
, Issue.SUPPL. 1
-
-
Weinzimer, S.A.1
Sherr, J.L.2
Cengiz, E.3
-
41
-
-
77249157244
-
Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: A phase 2 randomised crossover trial
-
Hovorka R, Allen JM, Elleri D, et al. Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial. Lancet 2010; 375:743-751.
-
(2010)
Lancet
, vol.375
, pp. 743-751
-
-
Hovorka, R.1
Allen, J.M.2
Elleri, D.3
-
42
-
-
79954457764
-
Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: Crossover randomised controlled studies
-
Two small crossover studies that showed improvements in overnight blood glucose levels (time within target and time spent hypoglycemic) with a closed-loop compared with open-loop system, after two types of mealtime challenges, one including a large meal with alcohol to simulate 'eating out'
-
Hovorka R, Kumareswaran K, Harris J, et al. Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies. BMJ 2011; 342:1855-1864. Two small crossover studies that showed improvements in overnight blood glucose levels (time within target and time spent hypoglycemic) with a closed-loop compared with open-loop system, after two types of mealtime challenges, one including a large meal with alcohol to simulate 'eating out'.
-
(2011)
BMJ
, vol.342
, pp. 1855-1864
-
-
Hovorka, R.1
Kumareswaran, K.2
Harris, J.3
-
43
-
-
79951699957
-
Closed-loop insulin delivery during pregnancycomplicated by type1 diabetes
-
Murphy HR, Elleri D, Allen JM, et al. Closed-loop insulin delivery during pregnancycomplicated by type1 diabetes. Diabetes Care 2011; 34:406-411.
-
(2011)
Diabetes Care
, vol.34
, pp. 406-411
-
-
Murphy, H.R.1
Elleri, D.2
Allen, J.M.3
-
44
-
-
82555199427
-
Safety and efficacy of 24-h closed-loop insulin delivery in well controlled pregnant women with type 1 diabetes: A randomized crossover case series
-
Murphy HR, Kumareswaran K, Elleri D, et al. Safety and efficacy of 24-h closed-loop insulin delivery in well controlled pregnant women with type 1 diabetes: a randomized crossover case series. Diabetes Care 2011; 34:2527-2529.
-
(2011)
Diabetes Care
, vol.34
, pp. 2527-2529
-
-
Murphy, H.R.1
Kumareswaran, K.2
Elleri, D.3
-
45
-
-
79953021776
-
Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: Summary of the results
-
This study demonstrated that an MPC-based closed-loop system achieved superior overnight glucose control, with more time in target and less hypoglycemia, compared with an open-loop system; of note, the design and initial testing of the algorithm was accomplished entirely in silico
-
Kovatchev B, Cobelli C, Renard E, et al. Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: summary of the results. J Diabetes Sci Technol 2010; 4:1374-1381. This study demonstrated that an MPC-based closed-loop system achieved superior overnight glucose control, with more time in target and less hypoglycemia, compared with an open-loop system; of note, the design and initial testing of the algorithm was accomplished entirely in silico.
-
(2010)
J Diabetes Sci Technol
, vol.4
, pp. 1374-1381
-
-
Kovatchev, B.1
Cobelli, C.2
Renard, E.3
-
46
-
-
77954901769
-
MD-logic artificial pancreas system: A pilot study in adults with type 1 diabetes
-
Atlas E, Nimri R, Miller S, et al. MD-logic artificial pancreas system: a pilot study in adults with type 1 diabetes. Diabetes Care 2010; 33:1072-1076.
-
(2010)
Diabetes Care
, vol.33
, pp. 1072-1076
-
-
Atlas, E.1
Nimri, R.2
Miller, S.3
-
47
-
-
74249093844
-
Closed-loop insulin delivery using a subcutaneous glucose sensor and intraperitoneal insulin delivery
-
Renard E, Place J, Cantwell M, et al. Closed-loop insulin delivery using a subcutaneous glucose sensor and intraperitoneal insulin delivery. Diabetes Care 2010; 33:121-127.
-
(2010)
Diabetes Care
, vol.33
, pp. 121-127
-
-
Renard, E.1
Place, J.2
Cantwell, M.3
-
48
-
-
77952987107
-
A bihormonal closed-loop artificial pancreas for type 1 diabetes
-
This study in 11 adult patients with type 1 diabetes demonstrated the feasibility of a two-hormone closed-loop system, with insulin and glucagon, using two infusion pumps and two separate controller algorithms
-
El-Khatib FH, Russell SJ, Nathan DM, et al. A bihormonal closed-loop artificial pancreas for type 1 diabetes. Transl Med 2010; 2:27ra27. This study in 11 adult patients with type 1 diabetes demonstrated the feasibility of a two-hormone closed-loop system, with insulin and glucagon, using two infusion pumps and two separate controller algorithms.
-
(2010)
Transl Med
, vol.2
-
-
El-Khatib, F.H.1
Russell, S.J.2
Nathan, D.M.3
-
49
-
-
77956071742
-
Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes
-
Castle JR, Engle JM, El Youssef J, et al. Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes. Diabetes Care 2010; 33:1282-1287.
-
(2010)
Diabetes Care
, vol.33
, pp. 1282-1287
-
-
Castle, J.R.1
Engle, J.M.2
El Youssef, J.3
-
50
-
-
69949146908
-
In silico preclinical trials: A proof of concept in closed-loop control of type 1 diabetes
-
Kovatchev BP, Breton M, Man CD, Cobelli C. In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes. J Diabetes Sci Technol 2009; 3:44-55.
-
(2009)
J Diabetes Sci Technol
, vol.3
, pp. 44-55
-
-
Kovatchev, B.P.1
Breton, M.2
Man, C.D.3
Cobelli, C.4
-
51
-
-
62249085411
-
In silico evaluation platform for artificial pancreatic beta-cell development: A dynamic simulator for closed-loop control with hardware-in-the-loop
-
Dassau E, Palerm CC, Zisser H, et al. In silico evaluation platform for artificial pancreatic beta-cell development: a dynamic simulator for closed-loop control with hardware-in-the-loop. Diabetes Technol Ther 2009; 11:187-194.
-
(2009)
Diabetes Technol Ther
, vol.11
, pp. 187-194
-
-
Dassau, E.1
Palerm, C.C.2
Zisser, H.3
-
52
-
-
77953067473
-
Identification of intraday metabolic profiles during closed-loop glucose control in individuals with type 1 diabetes
-
Kanderian SS, Weinzimer SA, Voskanyan G, Steil GM. Identification of intraday metabolic profiles during closed-loop glucose control in individuals with type 1 diabetes. J Diabetes Sci Technol 2009; 3:1047-1057.
-
(2009)
J Diabetes Sci Technol
, vol.3
, pp. 1047-1057
-
-
Kanderian, S.S.1
Weinzimer, S.A.2
Voskanyan, G.3
Steil, G.M.4
-
53
-
-
77954679388
-
Simulation environment to evaluate closed-loop insulin delivery systems in type 1 diabetes
-
Wilinska ME, Chassin LJ, Acerini CL, et al. Simulation environment to evaluate closed-loop insulin delivery systems in type 1 diabetes. J Diabetes Sci Technol 2010; 4:132-144.
-
(2010)
J Diabetes Sci Technol
, vol.4
, pp. 132-144
-
-
Wilinska, M.E.1
Chassin, L.J.2
Acerini, C.L.3
|