메뉴 건너뛰기




Volumn 20, Issue 7, 2005, Pages 909-913

Comparison between 4-hour clamping drainage and nonclamping drainage after total knee arthroplasty

Author keywords

Blood loss; Blood transfusion; Drainage clamping; Drains; Knee arthroplasty

Indexed keywords

ADULT; AGED; ARTICLE; CLAMP; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEEP VEIN THROMBOSIS; FEMALE; HEMATOCRIT; HEMOGLOBIN DETERMINATION; HUMAN; JOINT FUNCTION; LENGTH OF STAY; MALE; MORBIDITY; POSTOPERATIVE HEMORRHAGE; RANDOMIZED CONTROLLED TRIAL; STATISTICAL SIGNIFICANCE; SURGICAL DRAINAGE; SURGICAL TECHNIQUE; TOTAL KNEE REPLACEMENT; WOUND CARE;

EID: 26844529995     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2005.01.017     Document Type: Article
Times cited : (49)

References (26)
  • 1
    • 0022501925 scopus 로고
    • The use of postoperative suction drainage in total knee arthroplasty
    • T.J. Reilly, I.A. Gradisar Jr, and W. Pakan The use of postoperative suction drainage in total knee arthroplasty Clin Orthop Relat Res 208 1986 238
    • (1986) Clin Orthop Relat Res , vol.208 , pp. 238
    • Reilly, T.J.1    Gradisar Jr., I.A.2    Pakan, W.3
  • 2
    • 0025010915 scopus 로고
    • A comparative study of closed-wound suction drainage vs. no drainage in total hip arthroplasty
    • W.A. Hadden, and A.G. McFarlane A comparative study of closed-wound suction drainage vs. no drainage in total hip arthroplasty J Arthroplasty 5 1990 S21
    • (1990) J Arthroplasty , vol.5 , pp. 21
    • Hadden, W.A.1    McFarlane, A.G.2
  • 3
    • 0026492608 scopus 로고
    • The use of postoperative suction drainage in total hip arthroplasty
    • R.W. Acus, J.M. Clark, and I.A. Gradiser The use of postoperative suction drainage in total hip arthroplasty Orthopedics 15 1992 1325
    • (1992) Orthopedics , vol.15 , pp. 1325
    • Acus, R.W.1    Clark, J.M.2    Gradiser, I.A.3
  • 4
    • 0028210923 scopus 로고
    • Closed wound drainage in total hip or total knee replacement. a prospective, randomized study
    • M.A. Ritter, E.M. Keating, and P.M. Faris Closed wound drainage in total hip or total knee replacement. A prospective, randomized study J Bone Joint Surg Am 76 1994 35
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 35
    • Ritter, M.A.1    Keating, E.M.2    Faris, P.M.3
  • 5
    • 0031894727 scopus 로고    scopus 로고
    • Is suction drainage necessary after total joint arthroplasty? a prospective study
    • X.M. Crevoisier, P. Reber, and B. Noesberger Is suction drainage necessary after total joint arthroplasty? A prospective study Arch Orthop Trauma Surg 117 1998 121
    • (1998) Arch Orthop Trauma Surg , vol.117 , pp. 121
    • Crevoisier, X.M.1    Reber, P.2    Noesberger, B.3
  • 6
    • 0031752913 scopus 로고    scopus 로고
    • Postoperative drainage of knee arthroplasty is not necessary: A randomized study of 90 patients
    • G. Adalberth, S. Bystrom, and K. Kolstad Postoperative drainage of knee arthroplasty is not necessary: a randomized study of 90 patients Acta Orthop Scand 69 1998 475
    • (1998) Acta Orthop Scand , vol.69 , pp. 475
    • Adalberth, G.1    Bystrom, S.2    Kolstad, K.3
  • 7
    • 0034261453 scopus 로고    scopus 로고
    • Complications in total knee arthroplasty with and without surgical drainage
    • R.S. Corpe, J.W. Gallentine, and T.R. Young Complications in total knee arthroplasty with and without surgical drainage J South Orthop Assoc 9 2000 207
    • (2000) J South Orthop Assoc , vol.9 , pp. 207
    • Corpe, R.S.1    Gallentine, J.W.2    Young, T.R.3
  • 8
    • 0033859889 scopus 로고    scopus 로고
    • Drainage is of no use in primary uncomplicated cemented hip and knee arthroplasty for osteoarthritis: A prospective randomized study
    • R.O. Niskanen, O.L. Korkala, and J. Haapala Drainage is of no use in primary uncomplicated cemented hip and knee arthroplasty for osteoarthritis: a prospective randomized study J Arthroplasty 15 2000 567
    • (2000) J Arthroplasty , vol.15 , pp. 567
    • Niskanen, R.O.1    Korkala, O.L.2    Haapala, J.3
  • 9
    • 0035464289 scopus 로고    scopus 로고
    • No drainage does not increase complication risk after total knee prosthesis implantation: A prospective, comparative, randomized study
    • J.Y. Jenny, C. Boeri, and S. Lafare No drainage does not increase complication risk after total knee prosthesis implantation: a prospective, comparative, randomized study Knee Surg Sports Traumatol Arthrosc 9 2001 299
    • (2001) Knee Surg Sports Traumatol Arthrosc , vol.9 , pp. 299
    • Jenny, J.Y.1    Boeri, C.2    Lafare, S.3
  • 10
    • 0037355680 scopus 로고    scopus 로고
    • The use of a closed-suction drain in total knee arthroplasty. a prospective, randomised study
    • C.N. Esler, C. Blakeway, and N.J. Fiddian The use of a closed-suction drain in total knee arthroplasty. A prospective, randomised study J Bone Joint Surg Br 85 2003 215
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 215
    • Esler, C.N.1    Blakeway, C.2    Fiddian, N.J.3
  • 11
    • 0028937352 scopus 로고
    • Optimal timing of wound drain removal following total joint arthroplasty
    • C.J. Drinkwater, and M.J. Neil Optimal timing of wound drain removal following total joint arthroplasty J Arthroplasty 10 1995 185
    • (1995) J Arthroplasty , vol.10 , pp. 185
    • Drinkwater, C.J.1    Neil, M.J.2
  • 12
    • 0030856841 scopus 로고    scopus 로고
    • Comparison of closed-suction drainage and no drainage after primary total knee arthroplasty
    • B.T. Holt, N.L. Parks, and G.A. Engh Comparison of closed-suction drainage and no drainage after primary total knee arthroplasty Orthopedics 20 1997 1121
    • (1997) Orthopedics , vol.20 , pp. 1121
    • Holt, B.T.1    Parks, N.L.2    Engh, G.A.3
  • 13
    • 1542343832 scopus 로고    scopus 로고
    • Relevance of wound drainage in total knee arthroplasty-a prospective comparative study
    • A. Martin, M. Prenn, and T. Spiegel Relevance of wound drainage in total knee arthroplasty-a prospective comparative study Z Orthop Ihre Grenzgeb 142 2004 46
    • (2004) Z Orthop Ihre Grenzgeb , vol.142 , pp. 46
    • Martin, A.1    Prenn, M.2    Spiegel, T.3
  • 14
    • 0025278525 scopus 로고
    • Comparison between intermittent and continuous closed suction drainage of orthopedic wounds: A controlled clinical trial
    • A.T. Berman, D. Fabiano, and S.J. Bosacco Comparison between intermittent and continuous closed suction drainage of orthopedic wounds: a controlled clinical trial Orthopedics 13 1990 317
    • (1990) Orthopedics , vol.13 , pp. 317
    • Berman, A.T.1    Fabiano, D.2    Bosacco, S.J.3
  • 15
    • 0031913502 scopus 로고    scopus 로고
    • Drainage versus nondrainage in simultaneous bilateral total knee arthroplasties
    • Y.H. Kim, S.H. Cho, and R.S. Kim Drainage versus nondrainage in simultaneous bilateral total knee arthroplasties Clin Orthop 347 1998 188
    • (1998) Clin Orthop , vol.347 , pp. 188
    • Kim, Y.H.1    Cho, S.H.2    Kim, R.S.3
  • 16
    • 24144447574 scopus 로고
    • Blood loss associated with total knee arthroplasty
    • I.M. Jou, K.A. Lai, and C.Y. Yang Blood loss associated with total knee arthroplasty J Orthop Surg (ROC) 10 1993 213
    • (1993) J Orthop Surg (ROC) , vol.10 , pp. 213
    • Jou, I.M.1    Lai, K.A.2    Yang, C.Y.3
  • 17
    • 0034987421 scopus 로고    scopus 로고
    • Comparison between 1-hour and 24-hour drain clamping using diluted epinephrine solution after total knee arthroplasty
    • K. Yamada, T. Imaizumi, and M. Uemura Comparison between 1-hour and 24-hour drain clamping using diluted epinephrine solution after total knee arthroplasty J Arthroplasty 16 2001 458
    • (2001) J Arthroplasty , vol.16 , pp. 458
    • Yamada, K.1    Imaizumi, T.2    Uemura, M.3
  • 18
    • 0034791791 scopus 로고    scopus 로고
    • Does temporary clamping of drains following knee arthroplasty reduce blood loss? a randomized controlled trial
    • N. Kiely, M. Hockings, and A. Gambhir Does temporary clamping of drains following knee arthroplasty reduce blood loss? A randomized controlled trial Knee 8 2001 325
    • (2001) Knee , vol.8 , pp. 325
    • Kiely, N.1    Hockings, M.2    Gambhir, A.3
  • 19
    • 0029891721 scopus 로고    scopus 로고
    • Fibrinolytic inhibition with tranexamic acid reduce blood loss and blood transfusion after knee arthroplasty: A prospective, randomized, double blind study of 86 patients
    • G. Benoni, and H. Fredin Fibrinolytic inhibition with tranexamic acid reduce blood loss and blood transfusion after knee arthroplasty: a prospective, randomized, double blind study of 86 patients J Bone Joint Surg Br 78 1996 434
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 434
    • Benoni, G.1    Fredin, H.2
  • 20
    • 26844485706 scopus 로고    scopus 로고
    • Use of fibrin sealant to reduced bloody drainage and hemoglobin loss after total knee arthroplasty
    • G.J. Wang, D.S. Hungerford, and C.G. Savory Use of fibrin sealant to reduced bloody drainage and hemoglobin loss after total knee arthroplasty J Bone Joint Surg Am 83 2001 1053
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 1053
    • Wang, G.J.1    Hungerford, D.S.2    Savory, C.G.3
  • 21
    • 0027520267 scopus 로고
    • Reduction of postoperative blood loss after press-fit condylar knee arthroplasty with use of a femoral intramedullary plug
    • V.V. Raut, M.H. Stone, and B.M. Wroblewski Reduction of postoperative blood loss after press-fit condylar knee arthroplasty with use of a femoral intramedullary plug J Bone Joint Surg Am 75 1993 1356
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 1356
    • Raut, V.V.1    Stone, M.H.2    Wroblewski, B.M.3
  • 23
    • 0025033346 scopus 로고
    • Perioperative blood loss associated with total knee arthroplasty. a comparison of procedures performed with or without cementing
    • A.G. Mylod Jr, M.P. France, and D.E. Muser Perioperative blood loss associated with total knee arthroplasty. A comparison of procedures performed with or without cementing J Bone Joint Surg Am 72 1990 1010
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 1010
    • Mylod Jr., A.G.1    France, M.P.2    Muser, D.E.3
  • 24
    • 0026044701 scopus 로고
    • Blood loss after total knee arthroplasty: Effects of tourniquet release and continuous passive motion
    • P.A. Lotke, V.J. Faralli, and E.M. Orenstein Blood loss after total knee arthroplasty: effects of tourniquet release and continuous passive motion J Bone Joint Surg Am 73 1991 1037
    • (1991) J Bone Joint Surg Am , vol.73 , pp. 1037
    • Lotke, P.A.1    Faralli, V.J.2    Orenstein, E.M.3
  • 25
    • 0021720262 scopus 로고
    • Blood loss associated with ring uncemented total knee replacement: Comparison between continuous and intermittent suction drainage
    • F.W. Wittmann, and P.A. Ring Blood loss associated with ring uncemented total knee replacement: comparison between continuous and intermittent suction drainage J R Soc Med 77 1984 556
    • (1984) J R Soc Med , vol.77 , pp. 556
    • Wittmann, F.W.1    Ring, P.A.2
  • 26
    • 0034233873 scopus 로고    scopus 로고
    • How much blood loss is really lost in total knee arthroplasty? Correct blood loss management should take hidden blood loss into account
    • K.R. Sehat, R. Evans, and J.H. Newman How much blood loss is really lost in total knee arthroplasty? Correct blood loss management should take hidden blood loss into account Knee 7 2000 151
    • (2000) Knee , vol.7 , pp. 151
    • Sehat, K.R.1    Evans, R.2    Newman, J.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.