메뉴 건너뛰기




Volumn 43, Issue 3, 2012, Pages 276-281

Surveillance imaging modality does not affect detection rate of asymptomatic secondary interventions following EVAR

Author keywords

Asymptomatic secondary intervention; Complications; EVAR; Follow up

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ABDOMINAL RADIOGRAPHY; ADULT; AGED; ANEURYSM RUPTURE; ARTICLE; ASYMPTOMATIC SECONDARY INTERVENTION; CLINICAL PROTOCOL; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTRAST INDUCED NEPHROPATHY; DISEASE SURVEILLANCE; DOPPLER ECHOGRAPHY; ENDOLEAK; ENDOVASCULAR ANEURYSM REPAIR; FEMALE; FOLLOW UP; GRAFT INFECTION; HEALTH CARE COST; HEART INFARCTION; HUMAN; INTERVENTIONAL CARDIOVASCULAR PROCEDURE; INTESTINE ISCHEMIA; LIMB DISEASE; MAJOR CLINICAL STUDY; MALE; MORTALITY; PRIORITY JOURNAL; RADIATION EXPOSURE; STENT; SURVIVAL;

EID: 84858077169     PISSN: 10785884     EISSN: 15322165     Source Type: Journal    
DOI: 10.1016/j.ejvs.2011.11.020     Document Type: Article
Times cited : (24)

References (26)
  • 1
    • 26544437261 scopus 로고    scopus 로고
    • Imaging guidelines for abdominal aortic aneurysm repair with endovascular stent grafts
    • S.C. Geller Imaging guidelines for abdominal aortic aneurysm repair with endovascular stent grafts J Vasc Interv Radiol 14 2003 S263 S264
    • (2003) J Vasc Interv Radiol , vol.14
    • Geller, S.C.1
  • 2
    • 43849106769 scopus 로고    scopus 로고
    • Follow-up of endovascular aneurysm repair: Plain radiography, ultrasound, CT/CT angiography, MR imaging/MR angiography, or what?
    • P. Kranokpiraksa, and J.A. Kaufman Follow-up of endovascular aneurysm repair: plain radiography, ultrasound, CT/CT angiography, MR imaging/MR angiography, or what? J Vasc Interv Radiol 19 6 Suppl. 2008 S27 S36
    • (2008) J Vasc Interv Radiol , vol.19 , Issue.6 SUPPL.
    • Kranokpiraksa, P.1    Kaufman, J.A.2
  • 3
    • 78650845474 scopus 로고    scopus 로고
    • European Society for Vascular Surgery. Management of abdominal aortic aneurysms clinical practice guidelines of the European Society for Vascular Surgery
    • F.L. Moll, J.T. Powell, G. Fraedrich, F. Verzini, S. Haulon, and M. Waltham European Society for Vascular Surgery. Management of abdominal aortic aneurysms clinical practice guidelines of the European Society for Vascular Surgery Eur J Vasc Endovasc Surg 41 suppl. 1 2011 S1 S58
    • (2011) Eur J Vasc Endovasc Surg , vol.41 , Issue.SUPPL. 1
    • Moll, F.L.1    Powell, J.T.2    Fraedrich, G.3    Verzini, F.4    Haulon, S.5    Waltham, M.6
  • 6
    • 0034911651 scopus 로고    scopus 로고
    • Intraoperative proximal endoleaks during AAA stent-graft repair: Evaluation of risk factors and treatment with Palmaz stents
    • DOI 10.1583/1545-1550(2001)008<0268:IPEDAS>2.0.CO;2
    • N.V. Dias, T. Resch, M. Malina, B. Lindblad, and K. Ivancev Intraoperative proximal endoleaks during AAA stent-graft repair: evaluation of risk factors and treatment with Palmaz stents J Endovasc Ther 8 2001 268 273 (Pubitemid 32678738)
    • (2001) Journal of Endovascular Therapy , vol.8 , Issue.3 , pp. 268-273
    • Dias, N.V.1    Resch, T.2    Malina, M.3    Lindblad, B.4    Ivancev, K.5
  • 9
    • 70350507213 scopus 로고    scopus 로고
    • Long-term surveillance with computed tomography after endovascular aneurysm repair may not be justified
    • S.A. Black, T.W. Carrell, R.E. Bell, M. Waltham, J. Reidy, and P.R. Taylor Long-term surveillance with computed tomography after endovascular aneurysm repair may not be justified Br J Surg 96 2009 1280 1283
    • (2009) Br J Surg , vol.96 , pp. 1280-1283
    • Black, S.A.1    Carrell, T.W.2    Bell, R.E.3    Waltham, M.4    Reidy, J.5    Taylor, P.R.6
  • 12
    • 61449186559 scopus 로고    scopus 로고
    • Ultrasonographic surveillance with selective CTA after endovascular repair of abdominal aortic aneurysm
    • I. Bargellini, R. Cioni, V. Napoli, P. Petruzzi, C. Vignali, and A. Cicorelli Ultrasonographic surveillance with selective CTA after endovascular repair of abdominal aortic aneurysm J Endovasc Ther 16 2009 93 104
    • (2009) J Endovasc Ther , vol.16 , pp. 93-104
    • Bargellini, I.1    Cioni, R.2    Napoli, V.3    Petruzzi, P.4    Vignali, C.5    Cicorelli, A.6
  • 13
    • 0031849211 scopus 로고    scopus 로고
    • Intra- and interobserver variability in ultrasound measurements of abdominal aortic diameter. The Tromso study
    • DOI 10.1016/S1078-5884(98)80109-3
    • K. Singh, K.H. Bonaa, S. Solberg, D.G. Sorlie, and L. Bjork Intra- and interobserver variability in ultrasound measurements of abdominal aortic diameter. The Tromso Study Eur J Vasc Endovasc Surg 15 1998 497 504 (Pubitemid 28340038)
    • (1998) European Journal of Vascular and Endovascular Surgery , vol.15 , Issue.6 , pp. 497-504
    • Singh, K.1    Bonaa, K.H.2    Solberg, S.3    Sorlie, D.G.4    Bjork, L.5
  • 14
    • 0036831752 scopus 로고    scopus 로고
    • Measuring the abdominal aorta with ultrasonography and computed tomography - Difference and variability
    • DOI 10.1053/ejvs.2002.1748
    • A. Wanhainen, D. Bergqvist, and M. Bjorck Measuring the abdominal aorta with ultrasonography and computed tomography - difference and variability Eur J Vasc Endovasc Surg 24 2002 428 434 (Pubitemid 41079319)
    • (2002) European Journal of Vascular and Endovascular Surgery , vol.24 , Issue.5 , pp. 428-434
    • Wanhainen, A.1    Bergqvist, D.2    Bjorck, M.3
  • 15
    • 63049112353 scopus 로고    scopus 로고
    • Duplex ultrasound as the sole long-term surveillance method post-endovascular aneurysm repair: A safe alternative for stable aneurysms
    • R.A. Chaer, A. Gushchin, R. Rhee, L. Marone, J.S. Cho, and S. Leers Duplex ultrasound as the sole long-term surveillance method post-endovascular aneurysm repair: a safe alternative for stable aneurysms J Vasc Surg 49 2009 845 849
    • (2009) J Vasc Surg , vol.49 , pp. 845-849
    • Chaer, R.A.1    Gushchin, A.2    Rhee, R.3    Marone, L.4    Cho, J.S.5    Leers, S.6
  • 16
    • 70350573366 scopus 로고    scopus 로고
    • Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance: A cost analysis study and prospective comparison with computed tomography scan
    • B.R. Beeman, L.M. Doctor, K. Doerr, S. McAfee-Bennett, M.J. Dougherty, and K.D. Calligaro Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance: a cost analysis study and prospective comparison with computed tomography scan J Vasc Surg 50 2009 1019 1024
    • (2009) J Vasc Surg , vol.50 , pp. 1019-1024
    • Beeman, B.R.1    Doctor, L.M.2    Doerr, K.3    McAfee-Bennett, S.4    Dougherty, M.J.5    Calligaro, K.D.6
  • 17
    • 33748864627 scopus 로고    scopus 로고
    • Fate of endoleaks detected by CT angiography and missed by color duplex ultrasound in endovascular grafts for abdominal aortic aneurysms
    • A.F. AbuRahma Fate of endoleaks detected by CT angiography and missed by color duplex ultrasound in endovascular grafts for abdominal aortic aneurysms J Endovasc Ther 13 2006 490 495
    • (2006) J Endovasc Ther , vol.13 , pp. 490-495
    • Aburahma, A.F.1
  • 19
    • 77950063631 scopus 로고    scopus 로고
    • Duplex ultrasound and contrast-enhanced ultrasound versus computed tomography for the detection of endoleak after EVAR: Systematic review and bivariate meta-analysis
    • T.A. Mirza, A. Karthikesalingam, D. Jackson, S.R. Walsh, P.J. Holt, and P.D. Hayes Duplex ultrasound and contrast-enhanced ultrasound versus computed tomography for the detection of endoleak after EVAR: systematic review and bivariate meta-analysis Eur J Vasc Endovasc Surg 39 2010 418 428
    • (2010) Eur J Vasc Endovasc Surg , vol.39 , pp. 418-428
    • Mirza, T.A.1    Karthikesalingam, A.2    Jackson, D.3    Walsh, S.R.4    Holt, P.J.5    Hayes, P.D.6
  • 21
    • 3543036969 scopus 로고    scopus 로고
    • Surveillance after endovascular aneurysm repair: Diagnostics, complications, and associated costs
    • M. Prinssen, C.L. Wixon, E. Buskens, and J.D. Blankensteijn Surveillance after endovascular aneurysm repair: diagnostics, complications, and associated costs Ann Vasc Surg 18 2004 421 427 (Pubitemid 39014603)
    • (2004) Annals of Vascular Surgery , vol.18 , Issue.4 , pp. 421-427
    • Prinssen, M.1    Wixon, C.L.2    Buskens, E.3    Blankensteijn, J.D.4
  • 22
    • 47249134138 scopus 로고    scopus 로고
    • Redefining postoperative surveillance after endovascular aneurysm repair: Recommendations based on 5-year follow-up in the US Zenith multicenter trial
    • W.C. Sternbergh 3rd, R.K. Greenberg, T.A. Chuter, B.H. Tonnessen, and Zenith Investigators Redefining postoperative surveillance after endovascular aneurysm repair: recommendations based on 5-year follow-up in the US Zenith multicenter trial J Vasc Surg 48 2008 278 284
    • (2008) J Vasc Surg , vol.48 , pp. 278-284
    • Sternbergh III, W.C.1    Greenberg, R.K.2    Chuter, T.A.3    Tonnessen, B.H.4
  • 23
    • 33747845241 scopus 로고    scopus 로고
    • Contrast media and nephropathy: Findings from systematic analysis and food and drug administration reports of adverse effects
    • DOI 10.1097/01.rli.0000229742.54589.7b, PII 0000442420060800000008
    • R. Solomon, and W. DuMouchel Contrast media and nephropathy: findings from systematic analysis and food and drug administration reports of adverse effects Invest Radiol 41 2006 651 660 (Pubitemid 44284174)
    • (2006) Investigative Radiology , vol.41 , Issue.8 , pp. 651-660
    • Solomon, R.1    DuMouchel, W.2
  • 24
    • 44349101844 scopus 로고    scopus 로고
    • Comparison of the effects of open and endovascular aortic aneurysm repair on long-term renal function using chronic kidney disease staging based on glomerular filtration rate
    • DOI 10.1016/j.jvs.2008.01.039, PII S0741521408001766
    • J.L. Mills Sr, S.T. Duong, L.R. Leon Jr., K.R. Goshima, D.M. Ihnat, and C.S. Wendel Comparison of the effects of open and endovascular aortic aneurysm repair on long-term renal function using chronic kidney disease staging based on glomerular filtration rate J Vasc Surg 47 2008 1141 1149 (Pubitemid 351734609)
    • (2008) Journal of Vascular Surgery , vol.47 , Issue.6 , pp. 1141-1149
    • Mills Sr., J.L.1    Duong, S.T.2    Leon Jr., L.R.3    Goshima, K.R.4    Ihnat, D.M.5    Wendel, C.S.6    Gruessner, A.7
  • 25
    • 59649093480 scopus 로고    scopus 로고
    • DynaCT improves intra-operative quality control during endovascular abdominal aortic aneurysm repair
    • L. Biasi, T. Ali, L. Ratnam, R. Morgan, I.M. Loftus, and M.M. Thompson DynaCT improves intra-operative quality control during endovascular abdominal aortic aneurysm repair J Vasc Surg 49 2009 288 295
    • (2009) J Vasc Surg , vol.49 , pp. 288-295
    • Biasi, L.1    Ali, T.2    Ratnam, L.3    Morgan, R.4    Loftus, I.M.5    Thompson, M.M.6
  • 26
    • 10944252856 scopus 로고    scopus 로고
    • Endovascular graft limb occlusion
    • DOI 10.1053/j.semvascsurg.2004.09.002, PII S0895796704000626
    • J.D. Woody, and M.S. Makaroun Endovascular graft limb occlusion Semin Vasc Surg 17 2004 262 267 (Pubitemid 40018039)
    • (2004) Seminars in Vascular Surgery , vol.17 , Issue.4 SPEC. ISSUE , pp. 262-267
    • Woody, J.D.1    Makaroun, M.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.