메뉴 건너뛰기




Volumn 13, Issue 4, 2006, Pages 490-495

Fate of endoleaks detected by CT angiography and missed by color duplex ultrasound in endovascular grafts for abdominal aortic aneurysms

Author keywords

Abdominal aortic aneurysm; Color duplex ultrasound; Computed tomographic angiography; Endoleak; Endovascular repair

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ADULT; AGED; AORTA RECONSTRUCTION; ARTICLE; BLOOD VESSEL GRAFT; CLINICAL PROTOCOL; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; DISEASE CLASSIFICATION; ECHOGRAPHY; ENDOLEAK; FEMALE; FOLLOW UP; GOLD STANDARD; HUMAN; MAJOR CLINICAL STUDY; MALE; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD; PRIORITY JOURNAL; TREATMENT OUTCOME;

EID: 33748864627     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1583/06-1874R.1     Document Type: Article
Times cited : (38)

References (28)
  • 1
    • 0030824155 scopus 로고    scopus 로고
    • Post-operative color-flow duplex scanning in aortic endografting
    • Heilberger P, Schunn C, Ritter W, et al. Post-operative color-flow duplex scanning in aortic endografting. J Endovasc Surg. 1997;4:262-271.
    • (1997) J Endovasc Surg , vol.4 , pp. 262-271
    • Heilberger, P.1    Schunn, C.2    Ritter, W.3
  • 2
    • 0031757739 scopus 로고    scopus 로고
    • Endoleak after aortic stent graft repair: Diagnosis by color duplex ultrasound scan versus computed tomography scan
    • Sato DT, Goff CD, Gregory RT, et al. Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan. J Vasc Surg. 1998;28:657-663.
    • (1998) J Vasc Surg , vol.28 , pp. 657-663
    • Sato, D.T.1    Goff, C.D.2    Gregory, R.T.3
  • 3
    • 0033637752 scopus 로고    scopus 로고
    • Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair
    • Wolf YG, Johnson BL, Hill BR, et al. Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2000;32:1142-1148.
    • (2000) J Vasc Surg , vol.32 , pp. 1142-1148
    • Wolf, Y.G.1    Johnson, B.L.2    Hill, B.R.3
  • 4
    • 0035065705 scopus 로고    scopus 로고
    • Comparison of color duplex ultrasound and computed tomography scan for surveillance after aortic endografting
    • Pages S, Favre JP, Cerisier A, et al. Comparison of color duplex ultrasound and computed tomography scan for surveillance after aortic endografting. Ann Vasc Surg. 2001;15:155-162.
    • (2001) Ann Vasc Surg , vol.15 , pp. 155-162
    • Pages, S.1    Favre, J.P.2    Cerisier, A.3
  • 5
    • 0036263074 scopus 로고    scopus 로고
    • Detection of endoleak with enhanced ultrasound imaging: Comparison with biphasic computed tomography
    • McWilliams RG, Martin J, White D, et al. Detection of endoleak with enhanced ultrasound imaging: comparison with biphasic computed tomography. J Endovasc Ther. 2002;9:170-179.
    • (2002) J Endovasc Ther , vol.9 , pp. 170-179
    • McWilliams, R.G.1    Martin, J.2    White, D.3
  • 6
    • 0038275825 scopus 로고    scopus 로고
    • The significance and management of different types of endoleaks
    • Buth J, Harris PL, van Marrewijk C, et al. The significance and management of different types of endoleaks. Semin Vasc Surg. 2003;16:95-102.
    • (2003) Semin Vasc Surg , vol.16 , pp. 95-102
    • Buth, J.1    Harris, P.L.2    Van Marrewijk, C.3
  • 7
    • 0141885385 scopus 로고    scopus 로고
    • Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair
    • Raman KG, Missig-Carroll N, Richardson T, et al. Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg. 2003;38:645-651.
    • (2003) J Vasc Surg , vol.38 , pp. 645-651
    • Raman, K.G.1    Missig-Carroll, N.2    Richardson, T.3
  • 8
    • 2542436963 scopus 로고    scopus 로고
    • Computed tomography and ultrasound in follow-up of patients after endovascular repair of abdominal aortic aneurysm
    • Elkouri S, Panneton JM, Andrews JC, et al. Computed tomography and ultrasound in follow-up of patients after endovascular repair of abdominal aortic aneurysm. Ann Vasc Surg. 2004;18:271-279.
    • (2004) Ann Vasc Surg , vol.18 , pp. 271-279
    • Elkouri, S.1    Panneton, J.M.2    Andrews, J.C.3
  • 9
    • 0031820342 scopus 로고    scopus 로고
    • Rupture of abdominal aortic aneurysm previously treated by endovascular stent-graft
    • Torsello GB, Klenk E, Kasprzak B, et al. Rupture of abdominal aortic aneurysm previously treated by endovascular stent-graft. J Vasc Surg. 1998;28:184-187.
    • (1998) J Vasc Surg , vol.28 , pp. 184-187
    • Torsello, G.B.1    Klenk, E.2    Kasprzak, B.3
  • 10
    • 0031595465 scopus 로고    scopus 로고
    • Rupture of an abdominal aortic aneurysm after endovascular graft placement and aneurysm size reduction
    • Alimi YS, Chakfe N, Rivoal E, et al. Rupture of an abdominal aortic aneurysm after endovascular graft placement and aneurysm size reduction. J Vasc Surg. 1998;28:178-183.
    • (1998) J Vasc Surg , vol.28 , pp. 178-183
    • Alimi, Y.S.1    Chakfe, N.2    Rivoal, E.3
  • 11
    • 0033782683 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience
    • Harris PL, Vallabhaneni SR, Desgranges P, et al. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. J Vasc Surg. 2000;32:739-749.
    • (2000) J Vasc Surg , vol.32 , pp. 739-749
    • Harris, P.L.1    Vallabhaneni, S.R.2    Desgranges, P.3
  • 12
    • 0033902980 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm rupture following endoluminal graft deployment: Report of a predictable event
    • White RA, Donayre C, Walot I, et al. Abdominal aortic aneurysm rupture following endoluminal graft deployment: report of a predictable event. J Endovasc Ther. 2000;7:257-262.
    • (2000) J Endovasc Ther , vol.7 , pp. 257-262
    • White, R.A.1    Donayre, C.2    Walot, I.3
  • 13
    • 0034001024 scopus 로고    scopus 로고
    • A clinical perspective on the management of endoleaks after abdominal aortic endovascular aneurysm repair
    • Greenberg RK, Green R. A clinical perspective on the management of endoleaks after abdominal aortic endovascular aneurysm repair [letter]. J Vasc Surg. 2000;31:836-837.
    • (2000) J Vasc Surg , vol.31 , pp. 836-837
    • Greenberg, R.K.1    Green, R.2
  • 14
    • 29744467483 scopus 로고    scopus 로고
    • Clinical significance of type II endoleak after endovascular repair of abdominal aortic aneurysm
    • Gelfand DV, White GD, Wilson SE. Clinical significance of type II endoleak after endovascular repair of abdominal aortic aneurysm. Ann Vasc Surg. 2006;20:69-74.
    • (2006) Ann Vasc Surg , vol.20 , pp. 69-74
    • Gelfand, D.V.1    White, G.D.2    Wilson, S.E.3
  • 15
    • 0034235048 scopus 로고    scopus 로고
    • Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial
    • Zarins CK, White RA, Hodgson KJ, et al. Endoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial. J Vasc Surg. 2000;32:90-107.
    • (2000) J Vasc Surg , vol.32 , pp. 90-107
    • Zarins, C.K.1    White, R.A.2    Hodgson, K.J.3
  • 16
    • 26944486193 scopus 로고    scopus 로고
    • Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts
    • AbuRahma AF, Welch CA, Mullins BB, et al. Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts. J Endovasc Ther. 2005;12:568-573.
    • (2005) J Endovasc Ther , vol.12 , pp. 568-573
    • Aburahma, A.F.1    Welch, C.A.2    Mullins, B.B.3
  • 17
    • 0029908463 scopus 로고    scopus 로고
    • Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair
    • Chuter TA, Risberg B, Hopkinson BR, et al. Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair. J Vasc Surg. 1996;24:655-666.
    • (1996) J Vasc Surg , vol.24 , pp. 655-666
    • Chuter, T.A.1    Risberg, B.2    Hopkinson, B.R.3
  • 18
    • 0029998672 scopus 로고    scopus 로고
    • Transfemoral endovascular repair of abdominal aortic aneurysm: Results of the North American EVT phase 1 trial
    • Moore WS, Rutherford RB. Transfemoral endovascular repair of abdominal aortic aneurysm: results of the North American EVT phase 1 trial. J Vasc Surg. 1996;23:543-553.
    • (1996) J Vasc Surg , vol.23 , pp. 543-553
    • Moore, W.S.1    Rutherford, R.B.2
  • 19
    • 0030947672 scopus 로고    scopus 로고
    • Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: Classification, incidence, diagnosis, and management
    • White GH, Yu W, May J, et al. Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovasc Surg. 1997;4:152-168.
    • (1997) J Endovasc Surg , vol.4 , pp. 152-168
    • White, G.H.1    Yu, W.2    May, J.3
  • 20
    • 0033199924 scopus 로고    scopus 로고
    • Fate of endoleaks after endoluminal repair of abdominal aortic aneurysms with the EVT device
    • Makaroun M, Zajko A, Sugimoto H, et al. Fate of endoleaks after endoluminal repair of abdominal aortic aneurysms with the EVT device. Eur J Vasc Endovasc Surg. 1999;18:185-190.
    • (1999) Eur J Vasc Endovasc Surg , vol.18 , pp. 185-190
    • Makaroun, M.1    Zajko, A.2    Sugimoto, H.3
  • 21
    • 0031896189 scopus 로고    scopus 로고
    • Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm
    • Matsumura JS, Moore WS. Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm. J Vasc Surg. 1998;27:606-613.
    • (1998) J Vasc Surg , vol.27 , pp. 606-613
    • Matsumura, J.S.1    Moore, W.S.2
  • 22
    • 20444485179 scopus 로고    scopus 로고
    • Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: A systematic review
    • Ashoke R, Brown LC, Rodway A, et al. Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review. J Endovasc Ther. 2005;12:297-305.
    • (2005) J Endovasc Ther , vol.12 , pp. 297-305
    • Ashoke, R.1    Brown, L.C.2    Rodway, A.3
  • 23
    • 0036595201 scopus 로고    scopus 로고
    • Clinical failures of endovascular abdominal aortic aneurysm repair: Incidence, causes, and management
    • Dattilo JB, Brewster DC, Fan CM, et al. Clinical failures of endovascular abdominal aortic aneurysm repair: incidence, causes, and management. J Vasc Surg. 2002;35:1137-1144.
    • (2002) J Vasc Surg , vol.35 , pp. 1137-1144
    • Dattilo, J.B.1    Brewster, D.C.2    Fan, C.M.3
  • 24
    • 0032888365 scopus 로고    scopus 로고
    • Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repair
    • McWilliams RG, Martin J, White D, et al. Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repair. J Vasc Interv Radiol. 1999;10:1107-1114.
    • (1999) J Vasc Interv Radiol , vol.10 , pp. 1107-1114
    • McWilliams, R.G.1    Martin, J.2    White, D.3
  • 25
    • 0036514934 scopus 로고    scopus 로고
    • Significance of endoleaks after endovascular repair of abdominal aortic aneurysm: The EUROSTAR experience
    • van Marrewijk C, Buth J, Harris PL, et al. Significance of endoleaks after endovascular repair of abdominal aortic aneurysm: the EUROSTAR experience. J Vasc Surg. 2002;35:461-473.
    • (2002) J Vasc Surg , vol.35 , pp. 461-473
    • Van Marrewijk, C.1    Buth, J.2    Harris, P.L.3
  • 26
    • 0038697897 scopus 로고    scopus 로고
    • Duplex ultrasound imaging with an ultrasound contrast agent: The economic alternative to CT angiography for aortic stent graft surveillance
    • Bendick PJ, Zelenock GB, Bove PG, et al. Duplex ultrasound imaging with an ultrasound contrast agent: the economic alternative to CT angiography for aortic stent graft surveillance. Vasc Endovascular Surg. 2003;37:165-170.
    • (2003) Vasc Endovascular Surg , vol.37 , pp. 165-170
    • Bendick, P.J.1    Zelenock, G.B.2    Bove, P.G.3
  • 27
    • 0035109168 scopus 로고    scopus 로고
    • Aortic side branch embolization before endovascular aneurysm repair: Incidence of type II endoleak
    • Gould DA, McWilliams RG, Edwards RD, et al. Aortic side branch embolization before endovascular aneurysm repair: incidence of type II endoleak. J Vasc Interv Radiol. 2001;12:337-341.
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 337-341
    • Gould, D.A.1    McWilliams, R.G.2    Edwards, R.D.3
  • 28
    • 0034983403 scopus 로고    scopus 로고
    • Influence of treatment of type II leaks on the aneurysm surface area
    • Liewald F, Ermis C, Gorich J, et al. Influence of treatment of type II leaks on the aneurysm surface area. Eur J Vasc Endovasc Surg. 2001;21:339-343.
    • (2001) Eur J Vasc Endovasc Surg , vol.21 , pp. 339-343
    • Liewald, F.1    Ermis, C.2    Gorich, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.