-
1
-
-
77954664452
-
The history of biodegradable magnesium implants: A review
-
10.1016/j.actbio.2010.02.028 1:CAS:528:DC%2BC3cXns1yku7w%3D
-
F Witte 2010 The history of biodegradable magnesium implants: a review Acta Biomater 6 5 1680 1692 10.1016/j.actbio.2010.02.028 1:CAS:528: DC%2BC3cXns1yku7w%3D
-
(2010)
Acta Biomater
, vol.6
, Issue.5
, pp. 1680-1692
-
-
Witte, F.1
-
2
-
-
34249655184
-
Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: A prospective, non-randomised multicentre trial
-
DOI 10.1016/S0140-6736(07)60853-8, PII S0140673607608538
-
R Erbel C Di Mario J Bartunek J Bonnier B de Bruyne FR Eberli, et al. 2007 Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial Lancet 369 9576 1869 1875 10.1016/S0140-6736(07)60853-8 1:CAS:528:DC%2BD2sXmtVarur0%3D (Pubitemid 46829357)
-
(2007)
Lancet
, vol.369
, Issue.9576
, pp. 1869-1875
-
-
Erbel, R.1
Di Mario, C.2
Bartunek, J.3
Bonnier, J.4
De Bruyne, B.5
Eberli, F.R.6
Erne, P.7
Haude, M.8
Heublein, B.9
Horrigan, M.10
Ilsley, C.11
Bose, D.12
Koolen, J.13
Luscher, T.F.14
Weissman, N.15
Waksman, R.16
-
3
-
-
33749640689
-
Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
-
DOI 10.1002/ccd.20727
-
R Waksman R Pakala PK Kuchulakanti R Baffour D Hellinga R Seabron, et al. 2006 Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries Cathet Cardiovasc Intervent 68 4 607 617 10.1002/ccd.20727 (Pubitemid 44546055)
-
(2006)
Catheterization and Cardiovascular Interventions
, vol.68
, Issue.4
, pp. 607-617
-
-
Waksman, R.1
Pakala, R.2
Kuchulakanti, P.K.3
Baffour, R.4
Hellinga, D.5
Seabron, R.6
Tio, F.O.7
Wittchow, E.8
Hartwig, S.9
Harder, C.10
Rohde, R.11
Heublein, B.12
Andreae, A.13
Waldmann, K.-H.14
Haverich, A.15
-
4
-
-
31144443232
-
The road to bioabsorbable stents: Reaching clinical reality?
-
DOI 10.1007/s00270-004-0341-9
-
P Erne M Schier TJ Resink 2006 The road to bioabsorbable stents: reaching clinical reality? Cardiovasc Intervent Radiol 29 1 11 16 10.1007/s00270-004- 0341-9 (Pubitemid 43128134)
-
(2006)
CardioVascular and Interventional Radiology
, vol.29
, Issue.1
, pp. 11-16
-
-
Erne, P.1
Schier, M.2
Resink, T.J.3
-
5
-
-
64749089047
-
Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries
-
10.1016/j.jcin.2008.09.015
-
R Waksman R Erbel C Di Mario J Bartunek B de Bruyne FR Eberli, et al. 2009 Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries J Am Coll Cardiol Intv 2 4 312 320 10.1016/j.jcin.2008.09.015
-
(2009)
J Am Coll Cardiol Intv
, vol.2
, Issue.4
, pp. 312-320
-
-
Waksman, R.1
Erbel, R.2
Di Mario, C.3
Bartunek, J.4
De Bruyne, B.5
Eberli, F.R.6
-
6
-
-
65749107040
-
Degradable biomaterials based on magnesium corrosion
-
10.1016/j.cossms.2009.04.001 10.1016/j.cossms.2009.04.001 1:CAS:528:DC%2BD1MXmsVShu7o%3D
-
F Witte N Hort C Vogt S Cohen R Willumeit KU Kainer, et al. 2008 Degradable biomaterials based on magnesium corrosion Curr Opinion Solid State Mater Sci 12 63 72 10.1016/j.cossms.2009.04.001 10.1016/j.cossms.2009.04.001 1:CAS:528:DC%2BD1MXmsVShu7o%3D
-
(2008)
Curr Opinion Solid State Mater Sci
, vol.12
, pp. 63-72
-
-
Witte, F.1
Hort, N.2
Vogt, C.3
Cohen, S.4
Willumeit, R.5
Kainer, K.U.6
-
7
-
-
27644597192
-
In vitro and in vivo corrosion measurements of magnesium alloys
-
DOI 10.1016/j.biomaterials.2005.07.037, PII S0142961205007088
-
F Witte J Fischer J Nellesen HA Crostack V Kaese A Pisch, et al. 2006 In vitro and in vivo corrosion measurements of magnesium alloys Biomaterials 27 1013 1018 10.1016/j.biomaterials.2005.07.037 1:CAS:528:DC%2BD2MXhtF2qsbzJ (Pubitemid 41566693)
-
(2006)
Biomaterials
, vol.27
, Issue.7
, pp. 1013-1018
-
-
Witte, F.1
Fischer, J.2
Nellesen, J.3
Crostack, H.-A.4
Kaese, V.5
Pisch, A.6
Beckmann, F.7
Windhagen, H.8
-
8
-
-
77954682133
-
Critical discussion of the results from different corrosion studies of Mg and Mg alloys for biomaterial applications
-
10.1016/j.actbio.2009.12.048 1:CAS:528:DC%2BC3cXns1yrsr4%3D
-
W-D Mueller M Lucia Nascimento MF Lorenzo de Mele 2010 Critical discussion of the results from different corrosion studies of Mg and Mg alloys for biomaterial applications Acta Biomater 6 5 1749 1755 10.1016/j.actbio.2009. 12.048 1:CAS:528:DC%2BC3cXns1yrsr4%3D
-
(2010)
Acta Biomater
, vol.6
, Issue.5
, pp. 1749-1755
-
-
Mueller, W.-D.1
Lucia Nascimento, M.2
Lorenzo De Mele, M.F.3
-
9
-
-
78650386919
-
XPS studies of magnesium surfaces after exposure to Dulbecco's modified eagle medium, Hank's buffered salt solution, and simulated body fluid
-
10.1002/adem.201080070
-
D Tie F Feyerabend N Hort R Willumeit D Hoeche 2010 XPS studies of magnesium surfaces after exposure to Dulbecco's modified eagle medium, Hank's buffered salt solution, and simulated body fluid Adv Eng Mater 12 12 B699 B704 10.1002/adem.201080070
-
(2010)
Adv Eng Mater
, vol.12
, Issue.12
-
-
Tie, D.1
Feyerabend, F.2
Hort, N.3
Willumeit, R.4
Hoeche, D.5
-
10
-
-
79955581562
-
Chemical surface alteration of biodegradable magnesium exposed to corrosion media
-
10.1016/j.actbio.2011.03.004 1:CAS:528:DC%2BC3MXlsVCltbc%3D
-
R Willumeit J Fischer F Feyerabend N Hort U Bismayer S Heidrich, et al. 2011 Chemical surface alteration of biodegradable magnesium exposed to corrosion media Acta Biomater 7 2704 2715 10.1016/j.actbio.2011.03.004 1:CAS:528:DC%2BC3MXlsVCltbc%3D
-
(2011)
Acta Biomater
, vol.7
, pp. 2704-2715
-
-
Willumeit, R.1
Fischer, J.2
Feyerabend, F.3
Hort, N.4
Bismayer, U.5
Heidrich, S.6
-
11
-
-
67349213357
-
Effect of inorganic salts, amino acids and proteins on the degradation of pure magnesium in vitro
-
10.1016/j.msec.2008.12.015 1:CAS:528:DC%2BD1MXmtVaru7o%3D
-
A Yamamoto S Hiromoto 2009 Effect of inorganic salts, amino acids and proteins on the degradation of pure magnesium in vitro Mater Sci Eng C 29 5 1559 1568 10.1016/j.msec.2008.12.015 1:CAS:528:DC%2BD1MXmtVaru7o%3D
-
(2009)
Mater Sci Eng C
, vol.29
, Issue.5
, pp. 1559-1568
-
-
Yamamoto, A.1
Hiromoto, S.2
-
12
-
-
0036158388
-
Redifferentiation of dedifferentiated bovine articular chondrocytes in alginate culture under low oxygen tension
-
DOI 10.1053/joca.2001.0477
-
C Domm M Schunke K Christesen B Kurz 2002 Redifferentiation of dedifferentiated bovine articular chondrocytes in alginate culture under low oxygen tension Osteoarthr Cartil 10 1 13 22 10.1053/joca.2001.0477 1:STN:280:DC%2BD38%2FntV2isg%3D%3D (Pubitemid 34120986)
-
(2002)
Osteoarthritis and Cartilage
, vol.10
, Issue.1
, pp. 13-22
-
-
Domm, C.1
Schunke, M.2
Christesen, K.3
Kurz, B.4
-
13
-
-
0034982488
-
Combination of reduced oxygen tension and intermittent hydrostatic pressure: A useful tool in articular cartilage tissue engineering
-
DOI 10.1016/S0021-9290(01)00050-1, PII S0021929001000501
-
U Hansen M Schunke C Domm N Ioannidis J Hassenpflug T Gehrke, et al. 2001 Combination of reduced oxygen tension and intermittent hydrostatic pressure: a useful tool in articular cartilage tissue engineering J Biomech 34 7 941 949 10.1016/S0021-9290(01)00050-1 1:STN:280:DC%2BD3MzkslGqsw%3D%3D (Pubitemid 32530061)
-
(2001)
Journal of Biomechanics
, vol.34
, Issue.7
, pp. 941-949
-
-
Hansen, U.1
Schunke, M.2
Domm, C.3
Ioannidis, N.4
Hassenpflug, J.5
Gehrke, T.6
Kurz, B.7
-
14
-
-
0001082790
-
Influence of oxygen concentration and mechanical factors on differentiation of connective tissues in vitro
-
10.1038/190460a0 1:STN:280:DyaF3c%2Fgs1yktw%3D%3D
-
CA Bassett I Herrmann 1961 Influence of oxygen concentration and mechanical factors on differentiation of connective tissues in vitro Nature 190 460 461 10.1038/190460a0 1:STN:280:DyaF3c%2Fgs1yktw%3D%3D
-
(1961)
Nature
, vol.190
, pp. 460-461
-
-
Bassett, C.A.1
Herrmann, I.2
-
15
-
-
77954681094
-
Evaluation of short-term effects of rare earth and other elements used in magnesium alloys on primary cells and cell lines
-
10.1016/j.actbio.2009.09.024 1:CAS:528:DC%2BC3cXns1yrs74%3D
-
F Feyerabend J Fischer J Holtz F Witte R Willumeit H Drücker, et al. 2010 Evaluation of short-term effects of rare earth and other elements used in magnesium alloys on primary cells and cell lines Acta Biomater 6 5 1834 1842 10.1016/j.actbio.2009.09.024 1:CAS:528:DC%2BC3cXns1yrs74%3D
-
(2010)
Acta Biomater
, vol.6
, Issue.5
, pp. 1834-1842
-
-
Feyerabend, F.1
Fischer, J.2
Holtz, J.3
Witte, F.4
Willumeit, R.5
Drücker, H.6
-
16
-
-
18744382391
-
Buffer capacities of human blood and plasma
-
1:STN:280:DyaG1M%2FjvVCgtg%3D%3D
-
G Ellison JV Straumfjord Jr JP Hummel 1958 Buffer capacities of human blood and plasma Clin Chem 4 6 452 461 1:STN:280:DyaG1M%2FjvVCgtg%3D%3D
-
(1958)
Clin Chem
, vol.4
, Issue.6
, pp. 452-461
-
-
Ellison, G.1
Straumfjord Jr., J.V.2
Hummel, J.P.3
-
17
-
-
34249744766
-
Magnesium and its alloys as degradable biomaterials. Corrosion studies using potentiodynamic and EIS electrochemical techniques
-
WD Mueller ML Nascimento M Zeddies M Córsico 2007 Magnesium and its alloys as degradable biomaterials. Corrosion studies using potentiodynamic and eis electrochemical techniques Mater Res 10 1 5 10 1:CAS:528: DC%2BD2sXls12lu70%3D (Pubitemid 46830253)
-
(2007)
Materials Research
, vol.10
, Issue.1
, pp. 5-10
-
-
Muller, W.D.1
Nascimento, M.L.2
Zeddies, M.3
Corsico, M.4
Gassa, L.M.5
De Mele, M.A.F.L.6
-
18
-
-
72649097379
-
A survey of bio-corrosion rates of magnesium alloys
-
10.1016/j.corsci.2009.09.033 1:CAS:528:DC%2BD1MXhs1Wit7nJ
-
NT Kirkland J Lespagnol N Birbilis MP Staiger 2010 A survey of bio-corrosion rates of magnesium alloys Corros Sci 52 2 287 291 10.1016/j.corsci.2009.09.033 1:CAS:528:DC%2BD1MXhs1Wit7nJ
-
(2010)
Corros Sci
, vol.52
, Issue.2
, pp. 287-291
-
-
Kirkland, N.T.1
Lespagnol, J.2
Birbilis, N.3
Staiger, M.P.4
-
19
-
-
67650497413
-
Degradation of magnesium and its alloys: Dependence on the composition of the synthetic biological media
-
10.1002/jbm.a.32106 1:CAS:528:DC%2BD1MXnslyqsL0%3D
-
W-D Mueller MFLd Mele ML Nascimento M Zeddies 2009 Degradation of magnesium and its alloys: dependence on the composition of the synthetic biological media J Biomed Mater Res A 90A 2 487 495 10.1002/jbm.a.32106 1:CAS:528:DC%2BD1MXnslyqsL0%3D
-
(2009)
J Biomed Mater Res A
, vol.90
, Issue.2
, pp. 487-495
-
-
Mueller, W.-D.1
Mfld, M.2
Nascimento, M.L.3
Zeddies, M.4
-
20
-
-
34547101002
-
Degradation susceptibility of surgical magnesium alloy in artificial biological fluid containing albumin
-
DOI 10.1557/jmr.2007.0241
-
C Liu Y Xin X Tian PK Chu 2007 Degradation susceptibility of surgical magnesium alloy in artificial biological fluid containing albumin J MaterRes 22 3 1806 1814 10.1557/jmr.2007.0241 1:CAS:528:DC%2BD2sXnvVajtr4%3D (Pubitemid 47098562)
-
(2007)
Journal of Materials Research
, vol.22
, Issue.7
, pp. 1806-1814
-
-
Liu, C.1
Xin, Y.2
Tian, X.3
Chu, P.K.4
-
21
-
-
58149373931
-
Composition of corrosion layers on a magnesium rare-earth alloy in simulated body fluids
-
10.1002/jbm.a.31887 1:CAS:528:DC%2BD1MXns1Gluw%3D%3D
-
R Rettig S Virtanen 2009 Composition of corrosion layers on a magnesium rare-earth alloy in simulated body fluids J Biomed Mater Res A 88A 2 359 369 10.1002/jbm.a.31887 1:CAS:528:DC%2BD1MXns1Gluw%3D%3D
-
(2009)
J Biomed Mater Res A
, vol.88
, Issue.2
, pp. 359-369
-
-
Rettig, R.1
Virtanen, S.2
-
22
-
-
70349929996
-
CO2-formatics: How do proteins bind carbon dioxide?
-
10.1021/ci9002377 1:CAS:528:DC%2BD1MXhtVelurjJ
-
TR Cundari AK Wilson ML Drummond HE Gonzalez KR Jorgensen S Payne, et al. 2009 CO2-formatics: how do proteins bind carbon dioxide? J Chem Inform Model 49 9 2111 2115 10.1021/ci9002377 1:CAS:528:DC%2BD1MXhtVelurjJ
-
(2009)
J Chem Inform Model
, vol.49
, Issue.9
, pp. 2111-2115
-
-
Cundari, T.R.1
Wilson, A.K.2
Drummond, M.L.3
Gonzalez, H.E.4
Jorgensen, K.R.5
Payne, S.6
-
23
-
-
40449134564
-
Time-dependent electrochemical characterization of the corrosion of a magnesium rare-earth alloy in simulated body fluids
-
DOI 10.1002/jbm.a.31550
-
R Rettig S Virtanen 2008 Time-dependent electrochemical characterization of the corrosion of a magnesium rare-earth alloy in simulated body fluids J Biomed Mater Res A 85 1 167 175 (Pubitemid 351355366)
-
(2008)
Journal of Biomedical Materials Research - Part A
, vol.85
, Issue.1
, pp. 167-175
-
-
Rettig, R.1
Virtanen, S.2
-
24
-
-
0038607044
-
Low temperature synthesis and characterization of nesquehonite
-
10.1023/A:1023916326626 1:CAS:528:DC%2BD3sXktFSlsL0%3D
-
JT Kloprogge WN Martens L Nothdurft LV Duong GE Webb 2003 Low temperature synthesis and characterization of nesquehonite J Mater Sci Lett 22 11 825 829 10.1023/A:1023916326626 1:CAS:528:DC%2BD3sXktFSlsL0%3D
-
(2003)
J Mater Sci Lett
, vol.22
, Issue.11
, pp. 825-829
-
-
Kloprogge, J.T.1
Martens, W.N.2
Nothdurft, L.3
Duong, L.V.4
Webb, G.E.5
-
25
-
-
33751536689
-
Corrosion product formation during NaCl induced atmospheric corrosion of magnesium alloy AZ91D
-
DOI 10.1016/j.corsci.2006.08.004, PII S0010938X06002629
-
M Jönsson D Persson D Thierry 2007 Corrosion product formation during NaCl induced atmospheric corrosion of magnesium alloy AZ91D Corros Sci 49 3 1540 1558 10.1016/j.corsci.2006.08.004 (Pubitemid 44838608)
-
(2007)
Corrosion Science
, vol.49
, Issue.3
, pp. 1540-1558
-
-
Jonsson, M.1
Persson, D.2
Thierry, D.3
-
26
-
-
77950219251
-
Development and biocompatibility of a novel corrodible fluoride-coated magnesium-calcium alloy with improved degradation kinetics and adequate mechanical properties for cardiovascular applications
-
1:CAS:528:DC%2BC3cXjslKhs70%3D
-
A Drynda T Hassel R Hoehn A Perz F-W Bach M Peuster 2010 Development and biocompatibility of a novel corrodible fluoride-coated magnesium-calcium alloy with improved degradation kinetics and adequate mechanical properties for cardiovascular applications J Biomed Mater Res A 93A 2 763 775 1:CAS:528:DC%2BC3cXjslKhs70%3D
-
(2010)
J Biomed Mater Res A
, vol.93
, Issue.2
, pp. 763-775
-
-
Drynda, A.1
Hassel, T.2
Hoehn, R.3
Perz, A.4
Bach, F.-W.5
Peuster, M.6
-
27
-
-
70349456551
-
Rare earth metals used in biodegradable magnesium-based stents do not interfere with proliferation of smooth muscle cells but do induce the upregulation of inflammatory genes
-
10.1002/jbm.a.32235 1:CAS:528:DC%2BD1MXhtFGlsLfI
-
A Drynda N Deinet N Braun M Peuster 2009 Rare earth metals used in biodegradable magnesium-based stents do not interfere with proliferation of smooth muscle cells but do induce the upregulation of inflammatory genes J Biomed Mater Res A 91A 2 360 369 10.1002/jbm.a.32235 1:CAS:528: DC%2BD1MXhtFGlsLfI
-
(2009)
J Biomed Mater Res A
, vol.91
, Issue.2
, pp. 360-369
-
-
Drynda, A.1
Deinet, N.2
Braun, N.3
Peuster, M.4
-
28
-
-
77954673809
-
Developments in metallic biodegradable stents
-
10.1016/j.actbio.2009.10.006 1:CAS:528:DC%2BC3cXns1yku70%3D
-
H Hermawan D Dubé D Mantovani 2010 Developments in metallic biodegradable stents Acta Biomater 6 5 1693 1697 10.1016/j.actbio.2009.10.006 1:CAS:528:DC%2BC3cXns1yku70%3D
-
(2010)
Acta Biomater
, vol.6
, Issue.5
, pp. 1693-1697
-
-
Hermawan, H.1
Dubé, D.2
Mantovani, D.3
-
29
-
-
77952027256
-
Hypoxia decreases sclerostin expression and increases Wnt signaling in osteoblasts
-
1:CAS:528:DC%2BC3cXlsVSktLc%3D
-
DC Genetos CA Toupadakis LF Raheja A Wong SE Papanicolaou DP Fyhrie, et al. 2010 Hypoxia decreases sclerostin expression and increases Wnt signaling in osteoblasts J Cell Biochem 110 2 457 467 1:CAS:528:DC%2BC3cXlsVSktLc%3D
-
(2010)
J Cell Biochem
, vol.110
, Issue.2
, pp. 457-467
-
-
Genetos, D.C.1
Toupadakis, C.A.2
Raheja, L.F.3
Wong, A.4
Papanicolaou, S.E.5
Fyhrie, D.P.6
|