메뉴 건너뛰기




Volumn 7, Issue 1, 2012, Pages 64-67

Plasma separation PMMA device driven by capillary force controlling surface wettability

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD SAMPLES; CAPILLARY ACTION; CAPILLARY FORCE; DIAGNOSTIC SYSTEMS; HAEMOLYSIS; HIGH-THROUGHPUT; HOT-EMBOSSING; HYDROPHILIC SURFACES; MASTER MOLDS; MICRO DEVICES; MICRO-FLUIDIC DEVICES; MICROFLUIDIC PUMPS; ON-CHIP SEPARATIONS; OXYGEN PLASMAS; PASSIVE MODE; PLASMA SEPARATION; POLY-L-LYSINE; POWER SUPPLY; RED BLOOD CELL; SURFACE WETTABILITY; THERMAL BONDING;

EID: 84857226497     PISSN: None     EISSN: 17500443     Source Type: Journal    
DOI: 10.1049/mnl.2011.0627     Document Type: Article
Times cited : (23)

References (22)
  • 1
    • 36549034893 scopus 로고    scopus 로고
    • Real sample analysis on microfluidic devices
    • DOI 10.1016/j.talanta.2007.10.019, PII S003991400700673X, Micro- and Nanotechnology in Electrochemical Detection Science - dedicated to Professor Joseph Wang on the occasion of his 60th birthday MNED 2007 SI
    • Crevillen, A.G., Harvas, M., Lopez, M.A., Gonzalez, M.C., and Escarpa, A.: ' Real sample analysis on microfluidic devices ', Talanta, 2007, 74, p. 342-357 10.1016/j.talanta.2007.10.019 (Pubitemid 350192535)
    • (2007) Talanta , vol.74 , Issue.3 , pp. 342-357
    • Crevillen, A.G.1    Hervas, M.2    Lopez, M.A.3    Gonzalez, M.C.4    Escarpa, A.5
  • 2
    • 4444248404 scopus 로고    scopus 로고
    • BioMEMS: State-of-the-art in detection, opportunities and prospects
    • DOI 10.1016/j.addr.2004.03.002, PII S0169409X04001401
    • Bashir, R.: ' BioMEMS: state-of-the-art in detection, opportunities and prospects ', Adv. Drug. Deliv. Rev., 2004, 56, p. 1565-1586 10.1016/j.addr.2004. 03.002 (Pubitemid 39177689)
    • (2004) Advanced Drug Delivery Reviews , vol.56 , Issue.11 , pp. 1565-1586
    • Bashir, R.1
  • 3
    • 70349263305 scopus 로고    scopus 로고
    • Integration of electrochemistry in micro-total analysis systems for biochemical assays: Recent developments
    • 10.1016/j.talanta.2009.06.039
    • Xu, X., Zhang, S., Chen, H., and Kong, J.: ' Integration of electrochemistry in micro-total analysis systems for biochemical assays: recent developments ', Talanta, 2009, 80, p. 8-18 10.1016/j.talanta.2009.06.039
    • (2009) Talanta , vol.80 , pp. 8-18
    • Xu, X.1    Zhang, S.2    Chen, H.3    Kong, J.4
  • 4
    • 0033749295 scopus 로고    scopus 로고
    • Status of point-of-care-testing: Promise, realities, and possibilities
    • 10.1016/S0009-9120(00)00138-7
    • Louis, P.ST.: ' Status of point-of-care-testing: promise, realities, and possibilities ', Clin. Biochem., 2000, 33, p. 427-440 10.1016/S0009-9120(00) 00138-7
    • (2000) Clin. Biochem. , vol.33 , pp. 427-440
    • Louis, P.St.1
  • 5
    • 59849105583 scopus 로고    scopus 로고
    • Point-of-care testing: Twenty years' experience
    • Wager, E.A., Yasin, B., and Yuan, S.: ' Point-of-care testing: twenty years' experience ', LABMEDICINE, 2008, 39, p. 560-563
    • (2008) LABMEDICINE , vol.39 , pp. 560-563
    • Wager, E.A.1    Yasin, B.2    Yuan, S.3
  • 6
    • 0035034233 scopus 로고    scopus 로고
    • Point of care testing in Critical Care Medicine: The clinician's view
    • DOI 10.1016/S0009-8981(01)00448-X, PII S000989810100448X
    • Drenck, N.E.: ' Point of care testing in critical care medicine: the clinician's view ', Clin. Chim. Acta., 2001, 307, p. 3-7 10.1016/S0009-8981(01) 00448-X (Pubitemid 32448896)
    • (2001) Clinica Chimica Acta , vol.307 , Issue.1-2 , pp. 3-7
    • Drenck, N.-E.1
  • 7
    • 0042381474 scopus 로고    scopus 로고
    • Healthcare chip for checking health condition from analysis of trace blood collected by painless needle
    • 10.1143/JJAP.42.3722 0021-4922
    • Oki, A., Takai, M., and Ogawa, H.: et al. ' Healthcare chip for checking health condition from analysis of trace blood collected by painless needle ', Jpn. J. Appl. Phys., 2003, 42, p. 3722-3727 10.1143/JJAP.42.3722 0021-4922
    • (2003) Jpn. J. Appl. Phys. , vol.42 , pp. 3722-3727
    • Oki, A.1    Takai, M.2    Ogawa, H.3
  • 9
    • 54749153568 scopus 로고    scopus 로고
    • PMMA microfluidic devices with three-dimensional features for blood cell filtration
    • 10.1088/0960-1317/18/9/095021 0960-1317
    • Li, J.M., Liu, C., and Dai, X.D.: et al. ' PMMA microfluidic devices with three-dimensional features for blood cell filtration ', J. Micromech. Microeng., 2008, 18, p. 095021-095028 10.1088/0960-1317/18/9/095021 0960-1317
    • (2008) J. Micromech. Microeng. , vol.18 , pp. 095021-095028
    • Li, J.M.1    Liu, C.2    Dai, X.D.3
  • 10
    • 59849123587 scopus 로고    scopus 로고
    • Isolation of plasma from whole blood using a microfludic chip in a continuous cross-flow
    • 10.1007/s11434-008-0551-7 1001-6538
    • Xing, C., Dafu, C., and LuLu, Z.: ' Isolation of plasma from whole blood using a microfludic chip in a continuous cross-flow ', Chin. Sci. Bull., 2009, 54, p. 324-327 10.1007/s11434-008-0551-7 1001-6538
    • (2009) Chin. Sci. Bull. , vol.54 , pp. 324-327
    • Xing, C.1    Dafu, C.2    Lulu, Z.3
  • 12
    • 2342619619 scopus 로고    scopus 로고
    • Continuous Particle Separation Through Deterministic Lateral Displacement
    • DOI 10.1126/science.1094567
    • Huang, L.R., Cox, E.C., Austin, R.H., and Sturm, L.C.: ' Continuous particle separation through deterministic lateral displacement ', Science, 2004, 304, p. 987-990 10.1126/science.1094567 0036-8075 (Pubitemid 38638091)
    • (2004) Science , vol.304 , Issue.5673 , pp. 987-990
    • Huang, L.R.1    Cox, E.C.2    Austin, R.H.3    Sturm, J.C.4
  • 13
    • 0014784715 scopus 로고
    • The reaction of bone to self-curing acrylic cement: A long-term histological study in man
    • Charnley, J.: ' The reaction of bone to self-curing acrylic cement: a long-term histological study in man ', J. Bone Joint. Surg., 1970, 52, p. 340-353
    • (1970) J. Bone Joint. Surg. , vol.52 , pp. 340-353
    • Charnley, J.1
  • 14
    • 1542314835 scopus 로고    scopus 로고
    • Physical and mechanical properties of PMMA resins containing γ-methacryloxypropyltrimethoxysilane
    • Kanie, T., Arikawa, H., Fujii, K., and Inoue, K.: ' Physical and mechanical properties of PMMA resins containing γ- methacryloxypropyltrimethoxysilane ', J. Oral Rehabil., 2004, 31, p. 166-171 10.1111/j.1365-2842.2004.01043.x (Pubitemid 38315486)
    • (2004) Journal of Oral Rehabilitation , vol.31 , Issue.2 , pp. 166-171
    • Kanie, T.1    Arikawa, H.2    Fujii, K.3    Inoue, K.4
  • 15
    • 50249173388 scopus 로고    scopus 로고
    • Variation of the mechanical properties of PMMA to suit osteoporotic cancellous bone
    • 10.1163/156856208785540154 0920-5063
    • Boger, A., Bisig, A., Bohner, M., Heini, P., and Schneider, E.: ' Variation of the mechanical properties of PMMA to suit osteoporotic cancellous bone ', J. Biomater. Sci. Polym. Ed., 2008, 19, p. 1125-1142 10.1163/156856208785540154 0920-5063
    • (2008) J. Biomater. Sci. Polym. Ed. , vol.19 , pp. 1125-1142
    • Boger, A.1    Bisig, A.2    Bohner, M.3    Heini, P.4    Schneider, E.5
  • 16
    • 34249794834 scopus 로고    scopus 로고
    • Chemical recycling of poly(methyl methacrylate) by pyrolysis. Potential use of the liquid fraction as a raw material for the reproduction of the polymer
    • DOI 10.1016/j.eurpolymj.2007.02.044, PII S0014305707001395
    • Achilias, D.S.: ' Chemical recycling of poly(methyl methacrylate) by pyrolysis. Potential use of the liquid fraction as a raw material for the reproduction of the polymer ', Eur. Polym. J., 2007, 43, p. 2564-2575 10.1016/j.eurpolymj.2007.02.044 0014-3057 (Pubitemid 46856374)
    • (2007) European Polymer Journal , vol.43 , Issue.6 , pp. 2564-2575
    • Achilias, D.S.1
  • 17
    • 74249110774 scopus 로고    scopus 로고
    • Switchable wettability on cooperative dual-responsive poly-L-lysine surface
    • 10.1021/la9041452 0743-7463
    • Guo, Y., Xia, F., Xu, L., Li, J., Yang, W., and Jiang, L.: ' Switchable wettability on cooperative dual-responsive poly-L-lysine surface ', Langmuir, 2010, 26, p. 1024-1028 10.1021/la9041452 0743-7463
    • (2010) Langmuir , vol.26 , pp. 1024-1028
    • Guo, Y.1    Xia, F.2    Xu, L.3    Li, J.4    Yang, W.5    Jiang, L.6
  • 18
    • 33749588791 scopus 로고    scopus 로고
    • Photopatterning in poly-l-lysine thin films using UV-enhanced hydrophilicity
    • DOI 10.1016/j.jcis.2006.07.062, PII S0021979706006746
    • Taguenang, J.M., Kassu, A., and Sharma, A.: ' Photopatterning in poly-L-lysine thin films using UV-enhanced hydrophilicity ', J. Colloid. Interf. Sci., 2006, 303, p. 525-531 10.1016/j.jcis.2006.07.062 (Pubitemid 44547948)
    • (2006) Journal of Colloid and Interface Science , vol.303 , Issue.2 , pp. 525-531
    • Taguenang, J.M.1    Kassu, A.2    Sharma, A.3
  • 19
    • 67349247806 scopus 로고    scopus 로고
    • Characterisation of PMMA microfluidic channels and devices fabricated by hot embossing and sealed by direct bonding
    • 10.1016/j.ca2009.01.007
    • Mathur, A., Roy, S.S., Tweedie, M., Mukhopadhyay, S., Mitra, S.K., and McLaughlin, J.A.: ' Characterisation of PMMA microfluidic channels and devices fabricated by hot embossing and sealed by direct bonding ', Curr. Appl. Phys., 2009, 9, p. 1199-1202 10.1016/j.cap.2009.01.007
    • (2009) Curr. Appl. Phys. , vol.9 , pp. 1199-1202
    • Mathur, A.1    Roy, S.S.2    Tweedie, M.3    Mukhopadhyay, S.4    Mitra, S.K.5    McLaughlin, J.A.6
  • 20
    • 33644844136 scopus 로고    scopus 로고
    • Fabrication and characterization of poly(methyl methacrylate) microfluidic devices bonded using surface modifications and solvents
    • 10.1039/b512179e
    • Brown, L., Koerner, T., Horton, J.H., and Oleschuk, R.D.: ' Fabrication and characterization of poly(methyl methacrylate) microfluidic devices bonded using surface modifications and solvents ', Lab on a Chip, 2006, 6, p. 66-73 10.1039/b512179e
    • (2006) Lab on A Chip , vol.6 , pp. 66-73
    • Brown, L.1    Koerner, T.2    Horton, J.H.3    Oleschuk, R.D.4
  • 21
    • 10444263785 scopus 로고    scopus 로고
    • Wettability interpretation of oxygen plasma modified poly(methyl methacrylate)
    • 10.1021/la048947s 0743-7463
    • Chai, J., Lu, F., Li, B., and Kwok, D.Y.: ' Wettability interpretation of oxygen plasma modified poly(methyl methacrylate) ', Langmuir, 2004, 20, p. 10919-10927 10.1021/la048947s 0743-7463
    • (2004) Langmuir , vol.20 , pp. 10919-10927
    • Chai, J.1    Lu, F.2    Li, B.3    Kwok, D.Y.4
  • 22
    • 0037027778 scopus 로고    scopus 로고
    • Characterization of air plasma-treated polymer surfaces by ESCA and contact angle measurements for optimization of surface stability and cell growth
    • DOI 10.1002/app.11209
    • Johansson, B.L., Larsson, A., Ocklind, A., and Ohrlund, A.: ' Characterization of air plasma-treated polymer surfaces by ESCA and contact angle measurements for optimization of surface stability and cell growth ', J. Appl. Polym. Sci., 2002, 86, p. 2618-2625 10.1002/app.11209 0021-8995 (Pubitemid 35220958)
    • (2002) Journal of Applied Polymer Science , vol.86 , Issue.10 , pp. 2618-2625
    • Johansson, B.-L.1    Larsson, A.2    Ocklind, A.3    Ohrlund, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.