메뉴 건너뛰기




Volumn 269, Issue 3, 2012, Pages 711-720

Use of cone beam computed tomography in otolaryngologic treatments

Author keywords

Cone beam computed tomography; Craniofacial fractures; Dentistry; Head and neck; Orthodontics; Otolarynology; Paranasal sinus; Temporal bone; Temporomandibular joint

Indexed keywords

CONTRAST MEDIUM;

EID: 84857042949     PISSN: 09374477     EISSN: 14344726     Source Type: Journal    
DOI: 10.1007/s00405-011-1781-x     Document Type: Review
Times cited : (20)

References (36)
  • 1
    • 64149087907 scopus 로고    scopus 로고
    • Comparison of airway space with conventional lateral headfilms and 3-dimensional reconstruction from cone-beam computed tomography
    • 19361733 10.1016/j.ajodo.2007.04.043
    • C Aboudara I Nielsen JC Huang K Maki AJ Miller D Hatcher 2009 Comparison of airway space with conventional lateral headfilms and 3-dimensional reconstruction from cone-beam computed tomography Am J Orthod Dentofacial Orthop 135 468 479 19361733 10.1016/j.ajodo.2007.04.043
    • (2009) Am J Orthod Dentofacial Orthop , vol.135 , pp. 468-479
    • Aboudara, C.1    Nielsen, I.2    Huang, J.C.3    Maki, K.4    Miller, A.J.5    Hatcher, D.6
  • 2
    • 0642303858 scopus 로고    scopus 로고
    • A three-dimensional evaluation of the upper airway in adolescents
    • 14606553 10.1034/j.1600-0544.2003.253.x
    • CA Aboudara D Hatcher IL Nielsen, et al. 2003 A three-dimensional evaluation of the upper airway in adolescents Orthod Craniofac Res 6 173 175 14606553 10.1034/j.1600-0544.2003.253.x
    • (2003) Orthod Craniofac Res , vol.6 , pp. 173-175
    • Aboudara, C.A.1    Hatcher, D.2    Nielsen, I.L.3
  • 3
    • 0033156083 scopus 로고    scopus 로고
    • Development of a compact computed tomographic apparatus for dental use
    • 10455389 10.1038/sj.dmfr.4600448 1:STN:280:DC%2BD3czitlKmtw%3D%3D
    • Y Arai E Tammisalo K Iwai, et al. 1999 Development of a compact computed tomographic apparatus for dental use Dentomaxillofac Radiol 28 245 248 10455389 10.1038/sj.dmfr.4600448 1:STN:280:DC%2BD3czitlKmtw%3D%3D
    • (1999) Dentomaxillofac Radiol , vol.28 , pp. 245-248
    • Arai, Y.1    Tammisalo, E.2    Iwai, K.3
  • 4
    • 53549129719 scopus 로고    scopus 로고
    • Clinical utility of intraoperative volume computed tomography scanner for endoscopic sinonasal and skull base procedures
    • 18954511 10.2500/ajr.2008.22.3216
    • PS Batra SJ Kanowitz MJ Citardi 2008 Clinical utility of intraoperative volume computed tomography scanner for endoscopic sinonasal and skull base procedures Am J Rhinol 22 511 515 18954511 10.2500/ajr.2008.22.3216
    • (2008) Am J Rhinol , vol.22 , pp. 511-515
    • Batra, P.S.1    Kanowitz, S.J.2    Citardi, M.J.3
  • 5
    • 44649153747 scopus 로고    scopus 로고
    • Current concepts in maxillofacial imaging
    • 18082349 10.1016/j.ejrad.2007.11.019
    • R Boeddinghaus A Whyte 2007 Current concepts in maxillofacial imaging Eur J Radiol 66 396 418 18082349 10.1016/j.ejrad.2007.11.019
    • (2007) Eur J Radiol , vol.66 , pp. 396-418
    • Boeddinghaus, R.1    Whyte, A.2
  • 6
    • 60749108309 scopus 로고    scopus 로고
    • CBCT dosimetry: Orthodontic considerations
    • 10.1053/j.sodo.2008.09.002
    • SL Brooks 2009 CBCT dosimetry: orthodontic considerations Semin Orthod 15 14 18 10.1053/j.sodo.2008.09.002
    • (2009) Semin Orthod , vol.15 , pp. 14-18
    • Brooks, S.L.1
  • 7
    • 45749150353 scopus 로고    scopus 로고
    • Intraoperative IGS/CT updates for complex endoscopic frontal sinus surgery
    • 18487904 10.1159/000133653
    • SK Chennupati BA Woodworth JN Palmer, et al. 2008 Intraoperative IGS/CT updates for complex endoscopic frontal sinus surgery ORL J Otorhinolaryngol Relat Spec 70 268 270 18487904 10.1159/000133653
    • (2008) ORL J Otorhinolaryngol Relat Spec , vol.70 , pp. 268-270
    • Chennupati, S.K.1    Woodworth, B.A.2    Palmer, J.N.3
  • 8
    • 31544450557 scopus 로고    scopus 로고
    • Value of digital volume tomography in patients with conductive hearing loss
    • 16163510 10.1007/s00405-005-0995-1 1:STN:280:DC%2BD28%2FlsVyqtQ%3D%3D
    • CV Dalchow AL Weber S Bien, et al. 2006 Value of digital volume tomography in patients with conductive hearing loss Eur Arch Otorhinolaryngol 263 92 99 16163510 10.1007/s00405-005-0995-1 1:STN:280:DC%2BD28%2FlsVyqtQ%3D%3D
    • (2006) Eur Arch Otorhinolaryngol , vol.263 , pp. 92-99
    • Dalchow, C.V.1    Weber, A.L.2    Bien, S.3
  • 9
    • 77950363820 scopus 로고    scopus 로고
    • Measuring the airway in 3 dimensions: A reliability and accuracy study
    • 10.1016/j.ajodo.2009.11.010
    • H El JM Palomo 2010 Measuring the airway in 3 dimensions: a reliability and accuracy study Am J Orthod Dentofacial Orthop 137 S50.e1 S50.e9 10.1016/j.ajodo.2009.11.010
    • (2010) Am J Orthod Dentofacial Orthop , vol.137
    • El, H.1    Palomo, J.M.2
  • 10
    • 60749125756 scopus 로고    scopus 로고
    • The basics of maxillofacial cone beam computed tomography
    • 10.1053/j.sodo.2008.09.001
    • AG Farman WC Scarfe 2009 The basics of maxillofacial cone beam computed tomography Semin Orthod 15 2 13 10.1053/j.sodo.2008.09.001
    • (2009) Semin Orthod , vol.15 , pp. 2-13
    • Farman, A.G.1    Scarfe, W.C.2
  • 11
    • 46249121625 scopus 로고    scopus 로고
    • Skeletal effects to the maxilla after rapid maxillary expansion assessed with cone-beam computed tomography
    • 18617096 10.1016/j.ajodo.2008.06.004
    • BJ Garrett JM Caruso K Rungcharassaeng, et al. 2008 Skeletal effects to the maxilla after rapid maxillary expansion assessed with cone-beam computed tomography Am J Orthod Dentofacial Orthop 134 8 9 18617096 10.1016/j.ajodo.2008. 06.004
    • (2008) Am J Orthod Dentofacial Orthop , vol.134 , pp. 8-9
    • Garrett, B.J.1    Caruso, J.M.2    Rungcharassaeng, K.3
  • 12
    • 50549099840 scopus 로고    scopus 로고
    • Quantitative cone-beam computed tomography evaluation of palatal bone thickness for orthodontic miniscrew placement
    • 18774082 10.1016/j.ajodo.2007.01.027
    • A Gracco L Lombardo M Cozzani, et al. 2008 Quantitative cone-beam computed tomography evaluation of palatal bone thickness for orthodontic miniscrew placement Am J Orthod Dentofacial Orthop 134 361 369 18774082 10.1016/j.ajodo.2007.01.027
    • (2008) Am J Orthod Dentofacial Orthop , vol.134 , pp. 361-369
    • Gracco, A.1    Lombardo, L.2    Cozzani, M.3
  • 13
    • 16544384782 scopus 로고    scopus 로고
    • Experimental flat-panel high-spatial resolution volume CT of the temporal bone
    • 15466345
    • R Gupta SH Bartling SK Basu, et al. 2004 Experimental flat-panel high-spatial resolution volume CT of the temporal bone Am J Neuroradiol 25 1417 1424 15466345
    • (2004) Am J Neuroradiol , vol.25 , pp. 1417-1424
    • Gupta, R.1    Bartling, S.H.2    Basu, S.K.3
  • 14
    • 66149102014 scopus 로고    scopus 로고
    • Effects of Mandibular Advancement Device (MAD) on airway dimensions assessed with cone-beam computed tomography
    • 10.1053/j.sodo.2009.02.001
    • JA Haskell J McCrillis BS Haskell JP Scheetz WC Scarfe AG Farman 2009 Effects of Mandibular Advancement Device (MAD) on airway dimensions assessed with cone-beam computed tomography Semin Orthod 15 132 158 10.1053/j.sodo.2009. 02.001
    • (2009) Semin Orthod , vol.15 , pp. 132-158
    • Haskell, J.A.1    McCrillis, J.2    Haskell, B.S.3    Scheetz, J.P.4    Scarfe, W.C.5    Farman, A.G.6
  • 15
    • 18244407740 scopus 로고    scopus 로고
    • Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm system
    • 16053844 10.1016/j.ijom.2004.09.010 1:STN:280:DC%2BD2MzpsFyltQ%3D%3D
    • M Heiland D Schulze F Blake, et al. 2005 Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm system Int J Oral Maxillofac Surg 34 369 375 16053844 10.1016/j.ijom.2004.09.010 1:STN:280:DC%2BD2MzpsFyltQ%3D%3D
    • (2005) Int J Oral Maxillofac Surg , vol.34 , pp. 369-375
    • Heiland, M.1    Schulze, D.2    Blake, F.3
  • 16
    • 33645731806 scopus 로고    scopus 로고
    • Cone-beam computed tomography in orthodontics: Benefits and limitations [in English, German]
    • 16331544 10.1007/s00056-005-0519-z
    • C Holberg S Steinhauser P Geis, et al. 2005 Cone-beam computed tomography in orthodontics: benefits and limitations [in English, German] J Orofac Orthop 66 434 444 16331544 10.1007/s00056-005-0519-z
    • (2005) J Orofac Orthop , vol.66 , pp. 434-444
    • Holberg, C.1    Steinhauser, S.2    Geis, P.3
  • 17
    • 41949096219 scopus 로고    scopus 로고
    • Role of different imaging modalities in assessment of temporomandibular joint erosions and osteophytes: A systematic review
    • 18239033 10.1259/dmfr/16932758 1:STN:280:DC%2BD1c7ot1Ggug%3D%3D
    • AM Hussain G Packota PW Major, et al. 2008 Role of different imaging modalities in assessment of temporomandibular joint erosions and osteophytes: a systematic review Dentomaxillofac Radiol 37 63 71 18239033 10.1259/dmfr/16932758 1:STN:280:DC%2BD1c7ot1Ggug%3D%3D
    • (2008) Dentomaxillofac Radiol , vol.37 , pp. 63-71
    • Hussain, A.M.1    Packota, G.2    Major, P.W.3
  • 18
    • 36649009595 scopus 로고    scopus 로고
    • Vertical bone volume in the paramedian palate of adolescents: A computed tomography study
    • 18068597 10.1016/j.ajodo.2005.11.042
    • KS King EW Lam MG Faulkner, et al. 2007 Vertical bone volume in the paramedian palate of adolescents: a computed tomography study Am J Orthod Dentofacial Orthop 132 783 788 18068597 10.1016/j.ajodo.2005.11.042
    • (2007) Am J Orthod Dentofacial Orthop , vol.132 , pp. 783-788
    • King, K.S.1    Lam, E.W.2    Faulkner, M.G.3
  • 19
    • 34547666996 scopus 로고    scopus 로고
    • Comparison of conventional and cone beam CT synthesized cephalograms
    • 17586852 10.1259/dmfr/98032356 1:STN:280:DC%2BD2szntFKjtg%3D%3D
    • V Kumar JB Ludlow A Mol, et al. 2007 Comparison of conventional and cone beam CT synthesized cephalograms Dentomaxillofac Radiol 36 263 269 17586852 10.1259/dmfr/98032356 1:STN:280:DC%2BD2szntFKjtg%3D%3D
    • (2007) Dentomaxillofac Radiol , vol.36 , pp. 263-269
    • Kumar, V.1    Ludlow, J.B.2    Mol, A.3
  • 20
    • 46249112769 scopus 로고    scopus 로고
    • Three-dimensional accuracy of measurements made with software on cone-beam computed tomography images
    • 10.1016/j.ajodo.2006.08.024
    • MO Lagrave're J Carey RW Toogood, et al. 2008 Three-dimensional accuracy of measurements made with software on cone-beam computed tomography images Am J Orthod Dentofacial Orthop 134 112 116 10.1016/j.ajodo.2006.08.024
    • (2008) Am J Orthod Dentofacial Orthop , vol.134 , pp. 112-116
    • Lagrave'Re, M.O.1    Carey, J.2    Toogood, R.W.3
  • 21
    • 14844361970 scopus 로고    scopus 로고
    • Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)
    • 10.1259/dmfr/31342245
    • CA Lascala J Panella MM Marques 2005 Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom) Dentomaxillofac Radiol 34 28 31 10.1259/dmfr/31342245
    • (2005) Dentomaxillofac Radiol , vol.34 , pp. 28-31
    • Lascala, C.A.1    Panella, J.2    Marques, M.M.3
  • 22
    • 0036082380 scopus 로고    scopus 로고
    • Three-dimensional CT with a modified C-arm image intensifier: Feasibility
    • 12091697 10.1148/radiol.2241010646
    • U Linsenmaier C Rock E Euler, et al. 2002 Three-dimensional CT with a modified C-arm image intensifier: feasibility Radiology 224 286 292 12091697 10.1148/radiol.2241010646
    • (2002) Radiology , vol.224 , pp. 286-292
    • Linsenmaier, U.1    Rock, C.2    Euler, E.3
  • 23
    • 33746041477 scopus 로고    scopus 로고
    • Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G, and i-CAT
    • 16798915 10.1259/dmfr/14340323 1:STN:280:DC%2BD28vksFOgtg%3D%3D
    • J Ludlow L Davies-Ludlow S Brooks, et al. 2006 Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G, and i-CAT Dentomaxillofac Radiol 35 219 226 16798915 10.1259/dmfr/14340323 1:STN:280:DC%2BD28vksFOgtg%3D%3D
    • (2006) Dentomaxillofac Radiol , vol.35 , pp. 219-226
    • Ludlow, J.1    Davies-Ludlow, L.2    Brooks, S.3
  • 24
    • 33845324076 scopus 로고    scopus 로고
    • Assessment of lateral cephalometric diagnosis of adenoid hypertrophy and posterior upper airway obstruction: A systematic review
    • 17169731 10.1016/j.ajodo.2005.05.050
    • MP Major C Flores-Mir PW Major 2006 Assessment of lateral cephalometric diagnosis of adenoid hypertrophy and posterior upper airway obstruction: a systematic review Am J Orthod Dentofacial Orthop 130 700 708 17169731 10.1016/j.ajodo.2005.05.050
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 700-708
    • Major, M.P.1    Flores-Mir, C.2    Major, P.W.3
  • 26
    • 61349173248 scopus 로고    scopus 로고
    • Obstructive sleep apnea and the use of cone beam computed tomography in airway imaging: A review
    • 10.1053/j.sodo.2008.09.008
    • JM McCrillis J Haskell BS Haskell, et al. 2009 Obstructive sleep apnea and the use of cone beam computed tomography in airway imaging: a review Semin Orthod 15 63 69 10.1053/j.sodo.2008.09.008
    • (2009) Semin Orthod , vol.15 , pp. 63-69
    • McCrillis, J.M.1    Haskell, J.2    Haskell, B.S.3
  • 27
    • 68549104047 scopus 로고    scopus 로고
    • Cone beam CT of the head and neck, part 2: Clinical applications
    • 19461061 10.3174/ajnr.A1654 1:STN:280:DC%2BD1Mrkt1KksA%3D%3D
    • AC Miracle BK Mukherji 2009 Cone beam CT of the head and neck, part 2: clinical applications Am J Neuroradiol 30 1285 1292 19461061 10.3174/ajnr.A1654 1:STN:280:DC%2BD1Mrkt1KksA%3D%3D
    • (2009) Am J Neuroradiol , vol.30 , pp. 1285-1292
    • Miracle, A.C.1    Mukherji, B.K.2
  • 28
    • 34648830600 scopus 로고    scopus 로고
    • Geometric accuracy of a newly developed cone-beam device for maxillofacial imaging
    • 17613260 10.1016/j.tripleo.2007.02.021
    • RA Mischkowski R Pulsfort L Ritter, et al. 2007 Geometric accuracy of a newly developed cone-beam device for maxillofacial imaging Oral Surg Oral Med Oral Pathol Oral Radiol Endod 104 551 559 17613260 10.1016/j.tripleo.2007.02.021
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.104 , pp. 551-559
    • Mischkowski, R.A.1    Pulsfort, R.2    Ritter, L.3
  • 29
    • 0032240404 scopus 로고    scopus 로고
    • A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results
    • 9866761 10.1007/s003300050586 1:STN:280:DyaK1M%2Fotl2qsQ%3D%3D
    • P Mozzo C Procacci A Tacconi, et al. 1998 A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results Eur Radiol 8 1558 1564 9866761 10.1007/s003300050586 1:STN:280:DyaK1M%2Fotl2qsQ%3D%3D
    • (1998) Eur Radiol , vol.8 , pp. 1558-1564
    • Mozzo, P.1    Procacci, C.2    Tacconi, A.3
  • 30
    • 84857040650 scopus 로고    scopus 로고
    • Health risks from exposure to low levels of ionizing radiation. BEIR VII Phase 2
    • National Research Council National Academies Press, Washington DC
    • National Research Council (2006) Health risks from exposure to low levels of ionizing radiation. BEIR VII Phase 2. In: Radiation-induced cancer : Mechanisms, quantitative experimental studies, and the role of genetic factors, vol 3, pp 65-89. National Academies Press, Washington DC
    • (2006) Radiation-induced Cancer: Mechanisms, Quantitative Experimental Studies, and the Role of Genetic Factors , vol.3 , pp. 65-89
  • 31
    • 24944525218 scopus 로고    scopus 로고
    • Two- and three-dimensional orthodontic imaging using limited cone beam-computed tomography
    • 16448229
    • A Nakajima GT Sameshima Y Arai, et al. 2005 Two- and three-dimensional orthodontic imaging using limited cone beam-computed tomography Angle Orthod 75 895 903 16448229
    • (2005) Angle Orthod , vol.75 , pp. 895-903
    • Nakajima, A.1    Sameshima, G.T.2    Arai, Y.3
  • 32
    • 33847166562 scopus 로고    scopus 로고
    • Clinical indications and perspectives for intraoperative cone-beam computed tomography in oral and maxillofacial surgery
    • 17321455 10.1016/j.tripleo.2006.05.008
    • P Pohlenz M Blessmann F Blake, et al. 2007 Clinical indications and perspectives for intraoperative cone-beam computed tomography in oral and maxillofacial surgery Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103 412 417 17321455 10.1016/j.tripleo.2006.05.008
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.103 , pp. 412-417
    • Pohlenz, P.1    Blessmann, M.2    Blake, F.3
  • 33
    • 33644798524 scopus 로고    scopus 로고
    • Investigation of C-arm cone-beam CT-guided surgery of the frontal recess
    • 16369157 10.1097/01.mlg.0000180759.52082.45 1:STN:280: DC%2BD28%2FgvFCiug%3D%3D
    • MA Rafferty JH Siewerdsen Y Chan, et al. 2005 Investigation of C-arm cone-beam CT-guided surgery of the frontal recess Laryngoscope. 115 2138 2143 16369157 10.1097/01.mlg.0000180759.52082.45 1:STN:280:DC%2BD28%2FgvFCiug%3D%3D
    • (2005) Laryngoscope. , vol.115 , pp. 2138-2143
    • Rafferty, M.A.1    Siewerdsen, J.H.2    Chan, Y.3
  • 34
    • 33744797413 scopus 로고    scopus 로고
    • Design and performance characteristics of a digital flat panel computed tomography system
    • 16872096 10.1118/1.2198941
    • W Ross DD Cody JD Hazle 2006 Design and performance characteristics of a digital flat panel computed tomography system Med Phys 33 1888 1901 16872096 10.1118/1.2198941
    • (2006) Med Phys , vol.33 , pp. 1888-1901
    • Ross, W.1    Cody, D.D.2    Hazle, J.D.3
  • 36
    • 33645960436 scopus 로고    scopus 로고
    • Dental age estimation through volume matching of teeth imaged by cone-beam CT
    • 10.1016/j.forsciint.2006.02.031
    • F Yang R Jacobs G Willems 2006 Dental age estimation through volume matching of teeth imaged by cone-beam CT Forensic Sci Int 159 78 83 10.1016/j.forsciint.2006.02.031
    • (2006) Forensic Sci Int , vol.159 , pp. 78-83
    • Yang, F.1    Jacobs, R.2    Willems, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.