메뉴 건너뛰기




Volumn 25, Issue 8, 2004, Pages 1417-1424

Experimental flat-panel high-spatial-resolution volume CT of the temporal bone

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE LESION; COCHLEA PROSTHESIS; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; EARDRUM; HEARING AID; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; MIDDLE EAR; MULTIDETECTOR COMPUTED TOMOGRAPHY; OPTICAL RESOLUTION; QUALITATIVE ANALYSIS; SCORING SYSTEM; TEMPORAL BONE; VESTIBULE AQUEDUCT; ARTIFACT; AUDITORY OSSICLE; CADAVER; EVALUATION; FACIAL NERVE; INNER EAR; MALE; METHODOLOGY; MIDDLE AGED; RADIOGRAPHY; STANDARD;

EID: 16544384782     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (108)

References (15)
  • 1
    • 0004701354 scopus 로고    scopus 로고
    • Temporal bone imaging
    • Som PM, Curtin HD, (eds). Mosby, St. Louis, MO
    • Chakeres DW, Augustyn MA. Temporal Bone Imaging. In: Som PM, Curtin HD, (eds). Head and Neck Imaging, 4th ed. Mosby, St. Louis, MO. 2003;1093-1108
    • (2003) Head and Neck Imaging, 4th Ed. , pp. 1093-1108
    • Chakeres, D.W.1    Augustyn, M.A.2
  • 2
    • 0038457603 scopus 로고    scopus 로고
    • The use of flat-panel detector CT for imaging
    • Kalender WA. The use of flat-panel detector CT for imaging. Radiologe 2003;43:379-387
    • (2003) Radiologe , vol.43 , pp. 379-387
    • Kalender, W.A.1
  • 3
    • 0021276522 scopus 로고
    • Clinical significance of partial volume averaging of the temporal bone
    • Chakeres DW. Clinical significance of partial volume averaging of the temporal bone. AJNR Am J Neuroradiol 1984;5:297-302
    • (1984) AJNR Am J Neuroradiol , vol.5 , pp. 297-302
    • Chakeres, D.W.1
  • 4
    • 0027538418 scopus 로고
    • Three-dimensional CT of the middle ear and adjacent structures
    • Ali QM, Ulrich C, Becker H. Three-dimensional CT of the middle ear and adjacent structures. Neuroradiology 1993;35:238-241
    • (1993) Neuroradiology , vol.35 , pp. 238-241
    • Ali, Q.M.1    Ulrich, C.2    Becker, H.3
  • 5
    • 0034086714 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    • Jaffray DA, Siewerdsen JH. Cone-beam computed tomography with a flat-panel imager: initial performance characterization. Med Phys 2000;27:1311-1323
    • (2000) Med Phys , vol.27 , pp. 1311-1323
    • Jaffray, D.A.1    Siewerdsen, J.H.2
  • 6
    • 0034926538 scopus 로고    scopus 로고
    • Alignment of a volumetric tomography system
    • Stevens GM, Saunders R, Pelc NJ. Alignment of a volumetric tomography system. Med Phys 2001;28:1472-1481
    • (2001) Med Phys , vol.28 , pp. 1472-1481
    • Stevens, G.M.1    Saunders, R.2    Pelc, N.J.3
  • 7
    • 0034742651 scopus 로고    scopus 로고
    • Vibrant sound bridge system, a new kind hearing prosthesis for patients with sensorineural hearing loss: Part II, audiological results
    • Lenarz T, Weber BP, Issing PR, et al. Vibrant sound bridge system, a new kind hearing prosthesis for patients with sensorineural hearing loss: part II, audiological results. Laryngorhinootologie 2001;80:370-380
    • (2001) Laryngorhinootologie , vol.80 , pp. 370-380
    • Lenarz, T.1    Weber, B.P.2    Issing, P.R.3
  • 10
    • 0036631452 scopus 로고    scopus 로고
    • Virtual endoscopy of the middle ear: Experimental and clinical results of a standardised approach using multi-slice helical computed tomography
    • Rodt T, Bartling S, Schmidt AM, Weber BP, Lenarz T, Becker H. Virtual endoscopy of the middle ear: experimental and clinical results of a standardised approach using multi-slice helical computed tomography. Eur Radiol 2002;12:1684-1692
    • (2002) Eur Radiol , vol.12 , pp. 1684-1692
    • Rodt, T.1    Bartling, S.2    Schmidt, A.M.3    Weber, B.P.4    Lenarz, T.5    Becker, H.6
  • 11
    • 0022356615 scopus 로고
    • Fenestral and cochlear otosclerosis: Computed tomographic evaluation
    • Swartz JD, Mandell DW, Wolfson RJ, et al. Fenestral and cochlear otosclerosis: computed tomographic evaluation. Am J Otol 1985;6:476-481
    • (1985) Am J Otol , vol.6 , pp. 476-481
    • Swartz, J.D.1    Mandell, D.W.2    Wolfson, R.J.3
  • 12
    • 0029036649 scopus 로고
    • Computed tomographic evaluation of surgically significant vascular variations related with the temporal bone
    • Atilla S, Akpek S, Uslu S, Ilgit ET, Isik S. Computed tomographic evaluation of surgically significant vascular variations related with the temporal bone. Eur J Radiol 1995;20:52-56
    • (1995) Eur J Radiol , vol.20 , pp. 52-56
    • Atilla, S.1    Akpek, S.2    Uslu, S.3    Ilgit, E.T.4    Isik, S.5
  • 13
    • 0029961077 scopus 로고    scopus 로고
    • CT detection of facial canal dehiscence and semicircular canal fistula: Comparison with surgical findings
    • Fuse T, Tada Y, Aoyagi M, Sugai Y. CT detection of facial canal dehiscence and semicircular canal fistula: comparison with surgical findings. J Comput Assist Tomogr 1996;20:221-224
    • (1996) J Comput Assist Tomogr , vol.20 , pp. 221-224
    • Fuse, T.1    Tada, Y.2    Aoyagi, M.3    Sugai, Y.4
  • 14
    • 0029093296 scopus 로고
    • Etiology of hearing loss and cochlear computed tomography: Findings in pre-implant assessment [Suppl]
    • Woolford TJ, Roberts GR, Hartley C, Ramsden RT. Etiology of hearing loss and cochlear computed tomography: findings in pre-implant assessment [Suppl]. Ann Otol Rhinol Laryngol 1995;166:201-206
    • (1995) Ann Otol Rhinol Laryngol , vol.166 , pp. 201-206
    • Woolford, T.J.1    Roberts, G.R.2    Hartley, C.3    Ramsden, R.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.