Volumn 27, Issue 1, 2012, Pages 128-135

MR measures of renal perfusion, oxygen bioavailability and total renal blood flow in a porcine model: Noninvasive regional assessment of renal function

Author keywords

arterial spin labeling; BOLD; magnetic resonance imaging; swine; total renal blood flow

Indexed keywords

ACETYLCHOLINE; ISOFLURANE; PROPOFOL;

EID: 84856676827     PISSN: 09310509     EISSN: 14602385     Source Type: Journal    
DOI: 10.1093/ndt/gfr199     Document Type: Article
Times cited : (18)

References (34)
  • 1
    • 34247502695 scopus 로고    scopus 로고
    • Assessment of renal hemodynamics and function in pigs with 64-section multidetector CT: Comparison with electron-beam CT
    • DOI 10.1148/radiol.2432060655
    • Daghini E, Primak AN, Chade AR et al. Assessment of renal hemo-dynamics and function in pigs with 64-section multidetector CT: comparison with electron-beam CT. Radiology 2007; 243: 405-412 (Pubitemid 46649695)
    • (2007) Radiology , vol.243 , Issue.2 , pp. 405-412
    • Daghini, E.1    Primak, A.N.2    Chade, A.R.3    Krier, J.D.4    Zhu, X.-Y.5    Ritman, E.L.6    McCollough, C.H.7    Lerman, L.O.8
  • 3
    • 0026695042 scopus 로고
    • Normal renal blood flow measurement using phase-contrast cine magnetic resonance imaging
    • Sommer G, Noorbehesht B, Pelc N et al. Normal renal blood flow measurement using phase-contrast cine magnetic resonance imaging. Invest Radiol 1992; 27: 465-470
    • (1992) Invest Radiol , vol.27 , pp. 465-470
    • Sommer, G.1    Noorbehesht, B.2    Pelc, N.3
  • 4
    • 0033006644 scopus 로고    scopus 로고
    • New methods to investigate the intrarenal distribution of blood flow and tubular fluid flow dynamics
    • DOI 10.1097/00041552-199903000-00002
    • Romero JC, Pelaez LI, Feldstein A et al. New methods to investigate the intrarenal distribution of blood flow and tubular fluid flow dynamics. Curr Opin Nephrol Hypertens 1999; 8: 157-166 (Pubitemid 29145186)
    • (1999) Current Opinion in Nephrology and Hypertension , vol.8 , Issue.2 , pp. 157-166
    • Romero, J.C.1    Pelaez, L.I.2    Feldstein, A.3    Lerman, L.O.4
  • 7
    • 77950465247 scopus 로고    scopus 로고
    • Preserved oxygenation despite reduced blood flow in poststenotic kidneys in human atherosclerotic renal artery stenosis
    • Gloviczki ML, Glockner JF, Lerman LO et al. Preserved oxygenation despite reduced blood flow in poststenotic kidneys in human atherosclerotic renal artery stenosis. Hypertension 2010; 55: 961-966
    • (2010) Hypertension , vol.55 , pp. 961-966
    • Gloviczki, M.L.1    Glockner, J.F.2    Lerman, L.O.3
  • 9
    • 0030979013 scopus 로고    scopus 로고
    • Noninvasive analysis of renal artery blood flow dynamics with MR cine phase-contrast flow measurements
    • Schoenberg SO, Just A, Bock M et al. Noninvasive analysis of renal artery blood flow dynamics with MR cine phase-contrast flow measurements. Am J Physiol 1997; 272: H2477-H2484
    • (1997) Am J Physiol , vol.272
    • Schoenberg, S.O.1    Just, A.2    Bock, M.3
  • 10
    • 0027524298 scopus 로고
    • Measurement of normal renal artery blood flow: Cine phase-contrast MR imaging vs clearance of p-aminohippurate
    • Wolf RL, King BF, Torres VE et al. Measurement of normal renal artery blood flow: cine phase-contrast MR imaging vs clearance of p-aminohippurate. AJR Am J Roentgenol 1993; 161: 995-1002 (Pubitemid 23333161)
    • (1993) American Journal of Roentgenology , vol.161 , Issue.5 , pp. 995-1002
    • Wolf, R.L.1    King, B.F.2    Torres, V.E.3    Wilson, D.M.4    Ehman, R.L.5
  • 12
    • 33646542004 scopus 로고    scopus 로고
    • Functional MRI of the kidney: Tools for translational studies of pathophysiology of renal disease
    • DOI 10.1152/ajprenal.00114.2005
    • Prasad PV. Functional MRI of the kidney: tools for translational studies of pathophysiology of renal disease. Am J Physiol Renal Physiol 2006; 290: F958-F974 (Pubitemid 43724894)
    • (2006) American Journal of Physiology - Renal Physiology , vol.290 , Issue.5
    • Prasad, P.V.1
  • 13
    • 0030453790 scopus 로고    scopus 로고
    • Noninvasive evaluation of intrarenal oxygenation with BOLD MRI
    • Prasad PV, Edelman RR, Epstein FH. Noninvasive evaluation of intrarenal oxygenation with BOLD MRI. Circulation 1996; 94: 3271-3275 (Pubitemid 26427498)
    • (1996) Circulation , vol.94 , Issue.12 , pp. 3271-3275
    • Prasad, P.V.1    Edelman, R.R.2    Epstein, F.H.3
  • 14
    • 0031020860 scopus 로고    scopus 로고
    • Oxygen and renal metabolism
    • Epstein FH. Oxygen and renal metabolism. Kidney Int 1997; 51: 381-385 (Pubitemid 27088147)
    • (1997) Kidney International , vol.51 , Issue.2 , pp. 381-385
    • Epstein, F.H.1
  • 16
    • 26844539882 scopus 로고    scopus 로고
    • Quantification of renal perfusion and function on a voxel-by-voxel basis: A feasibility study
    • DOI 10.1002/mrm.20608
    • Dujardin M, Sourbron S, Luypaert R et al. Quantification of renal perfusion and function on a voxel-by-voxel basis: a feasibility study. Magn Reson Med 2005; 54: 841-849 (Pubitemid 41457055)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.4 , pp. 841-849
    • Dujardin, M.1    Sourbron, S.2    Luypaert, R.3    Verbeelen, D.4    Stadnik, T.5
  • 17
    • 33947660916 scopus 로고    scopus 로고
    • Semiquantitative assessment of first-pass renal perfusion at 1.5 T: Comparison of 2D saturation recovery sequences with and without parallel imaging
    • DOI 10.2214/AJR.06.0567
    • Michaely HJ, Kramer H, Oesingmann N et al. Semiquantitative assessment of first-pass renal perfusion at 1.5 T: comparison of 2D saturation recovery sequences with and without parallel imaging. AJR Am J Roentgenol 2007; 188: 919-926 (Pubitemid 46496920)
    • (2007) American Journal of Roentgenology , vol.188 , Issue.4 , pp. 919-926
    • Michaely, H.J.1    Kramer, H.2    Oesingmann, N.3    Lodemann, K.-P.4    Reiser, M.F.5    Schoenberg, S.O.6
  • 20
    • 78751637427 scopus 로고    scopus 로고
    • Comparing kidney perfusion using non-contrast arterial spin labeling MRI and micro-sphere methods in an interventional swine model
    • Artz NS, Wentland AL, Sadowski EA et al. Comparing kidney perfusion using non-contrast arterial spin labeling MRI and micro-sphere methods in an interventional swine model. Invest Radiol 2011; 46: 124-131
    • (2011) Invest Radiol , vol.46 , pp. 124-131
    • Artz, N.S.1    Wentland, A.L.2    Sadowski, E.A.3
  • 22
    • 0030922875 scopus 로고    scopus 로고
    • Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: In vitro and in vivo validation
    • Lee VS, Spritzer CE, Carroll BA et al. Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: in vitro and in vivo validation. AJR Am J Roentgenol 1997; 169: 1125-1131
    • (1997) AJR Am J Roentgenol , vol.169 , pp. 1125-1131
    • Lee, V.S.1    Spritzer, C.E.2    Carroll, B.A.3
  • 23
    • 33749621769 scopus 로고    scopus 로고
    • Cine flow measurements using phase contrast with undersampled projections: In vitro validation and preliminary results in vivo
    • DOI 10.1002/jmri.20715
    • Wentland AL, Korosec FR, Vigen KK et al. Cine flow measurements using phase contrast with undersampled projections: in vitro validation and preliminary results in vivo. J Magn Reson Imaging 2006; 24: 945-951 (Pubitemid 44547011)
    • (2006) Journal of Magnetic Resonance Imaging , vol.24 , Issue.4 , pp. 945-951
    • Wentland, A.L.1    Korosec, F.R.2    Vigen, K.K.3    Wieben, O.4    Fine, J.P.5    Grist, T.M.6
  • 25
    • 0026539684 scopus 로고
    • Influence of desflurane, isoflurane and halothane on regional tissue perfusion in dogs
    • Hartman JC, Pagel PS, Proctor LT et al. Influence of desflurane, isoflurane and halothane on regional tissue perfusion in dogs. Can J Anaesth 1992; 39: 877-887
    • (1992) Can J Anaesth , vol.39 , pp. 877-887
    • Hartman, J.C.1    Pagel, P.S.2    Proctor, L.T.3
  • 26
    • 0029060933 scopus 로고
    • Renal perfusion in humans: MR imaging with spin tagging of arterial water
    • Roberts DA, Detre JA, Bolinger L et al. Renal perfusion in humans: MR imaging with spin tagging of arterial water. Radiology 1995; 196: 281-286
    • (1995) Radiology , vol.196 , pp. 281-286
    • Roberts, D.A.1    Detre, J.A.2    Bolinger, L.3
  • 27
    • 0036008752 scopus 로고    scopus 로고
    • 2*effects in vivo and ex vivo using iron oxide nanoparticles in steady state - Dependence on blood volume and water exchange
    • DOI 10.1002/mrm.10066
    • Bjornerud A, Johansson LO, Briley-Saebo K et al. Assessment of T1 and T2* effects in vivo and ex vivo using iron oxide nanoparticles in steady state-dependence on blood volume and water exchange. Magn Reson Med 2002; 47: 461-471 (Pubitemid 34194000)
    • (2002) Magnetic Resonance in Medicine , vol.47 , Issue.3 , pp. 461-471
    • Bjrnerud, A.1    Johansson, L.O.2    Briley-Sb, K.3    Ahlstrm, H.K.4
  • 28
    • 33646708508 scopus 로고    scopus 로고
    • Renal hemodynamic responses to intrarenal infusion of acetylcholine: Comparison with effects of PGE2 and NO donor
    • DOI 10.1038/sj.ki.5000338, PII 5000338
    • Badzynska B, Sadowski J. Renal hemodynamic responses to intra-renal infusion of acetylcholine: comparison with effects of PGE2 and NO donor. Kidney Int 2006; 69: 1774-1779 (Pubitemid 43739204)
    • (2006) Kidney International , vol.69 , Issue.10 , pp. 1774-1779
    • Badzynska, B.1    Sadowski, J.2
  • 29
    • 0034785375 scopus 로고    scopus 로고
    • Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function
    • Krier JD, Ritman EL, Bajzer Z et al. Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function. Am J Physiol Renal Physiol 2001; 281: F630-F638
    • (2001) Am J Physiol Renal Physiol , vol.281
    • Krier, J.D.1    Ritman, E.L.2    Bajzer, Z.3
  • 30
    • 0021275764 scopus 로고
    • Regional blood flow during isoflurane and halothane anesthesia
    • Gelman S, Fowler KC, Smith LR. Regional blood flow during iso-flurane and halothane anesthesia. Anesth Analg 1984; 63: 557-565 (Pubitemid 14121090)
    • (1984) Anesthesia and Analgesia , vol.63 , Issue.6 , pp. 557-565
    • Gelman, S.1    Fowler, K.C.2    Smith, L.R.3
  • 33
    • 0029640011 scopus 로고
    • Hypoxia of the renal medulla-its implications for disease
    • Brezis M, Rosen S. Hypoxia of the renal medulla-its implications for disease. N Engl J Med 1995; 332: 647-655
    • (1995) N Engl J Med , vol.332 , pp. 647-655
    • Brezis, M.1    Rosen, S.2
  • 34
    • 0031018713 scopus 로고    scopus 로고
    • Is tubuloglomerular feedback a tool to prevent nephron oxygen deficiency?
    • Schurek HJ, Johns O. Is tubuloglomerular feedback a tool to prevent nephron oxygen deficiency? Kidney Int 1997; 51: 386-392 (Pubitemid 27088148)
    • (1997) Kidney International , vol.51 , Issue.2 , pp. 386-392
    • Schurek, H.-J.1    Johns, O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.