메뉴 건너뛰기




Volumn 46, Issue 2, 2011, Pages 124-131

Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model

Author keywords

arterial spin labeling; kidney perfusion; microspheres; MRI; renal perfusion; swine

Indexed keywords

ACETYLCHOLINE; ISOFLURANE; MICROSPHERE;

EID: 78751637427     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e3181f5e101     Document Type: Article
Times cited : (53)

References (32)
  • 2
    • 33847239121 scopus 로고    scopus 로고
    • Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis
    • Kuo PH, Kanal E, Abu-Alfa AK, et al. Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis. Radiology. 2007;242:647-649.
    • (2007) Radiology , vol.242 , pp. 647-649
    • Kuo, P.H.1    Kanal, E.2    Abu-Alfa, A.K.3
  • 3
    • 0029872747 scopus 로고    scopus 로고
    • Magnetic resonance imaging for the evaluation of rejection of a kidney allograft in the rat
    • Beckmann N, Joergensen J, Bruttel K, et al. Magnetic resonance imaging for the evaluation of rejection of a kidney allograft in the rat. Transpl Int. 1996;9:175-183.
    • (1996) Transpl Int , vol.9 , pp. 175-183
    • Beckmann, N.1    Joergensen, J.2    Bruttel, K.3
  • 4
    • 29144434140 scopus 로고    scopus 로고
    • High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media
    • Boss A, Martirosian P, Graf H, et al. High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media. Rofo. 2005;177:1625-1630.
    • (2005) Rofo , vol.177 , pp. 1625-1630
    • Boss, A.1    Martirosian, P.2    Graf, H.3
  • 5
    • 14844343251 scopus 로고    scopus 로고
    • Arterial spin labeling blood flow magnetic resonance imaging for the characterization of metastatic renal cell carcinoma(1)
    • De Bazelaire C, Rofsky NM, Duhamel G, et al. Arterial spin labeling blood flow magnetic resonance imaging for the characterization of metastatic renal cell carcinoma(1). Acad Radiol. 2005;12:347-357.
    • (2005) Acad Radiol , vol.12 , pp. 347-357
    • De Bazelaire, C.1    Rofsky, N.M.2    Duhamel, G.3
  • 6
    • 33344460870 scopus 로고    scopus 로고
    • Perfusion MR imaging with FAIR true FISP spin labeling in patients with and without renal artery stenosis: Initial experience
    • Fenchel M, Martirosian P, Langanke J, et al. Perfusion MR imaging with FAIR true FISP spin labeling in patients with and without renal artery stenosis: initial experience. Radiology. 2006;238:1013-1021.
    • (2006) Radiology , vol.238 , pp. 1013-1021
    • Fenchel, M.1    Martirosian, P.2    Langanke, J.3
  • 7
    • 0033870368 scopus 로고    scopus 로고
    • Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE
    • Karger N, Biederer J, Lusse S, et al. Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE. Magn Reson Imaging. 2000;18: 641-647.
    • (2000) Magn Reson Imaging , vol.18 , pp. 641-647
    • Karger, N.1    Biederer, J.2    Lusse, S.3
  • 8
    • 0842285725 scopus 로고    scopus 로고
    • FAIR true-FISP perfusion imaging of the kidneys
    • Martirosian P, Klose U, Mader I, et al. FAIR true-FISP perfusion imaging of the kidneys. Magn Reson Med. 2004;51:353-361.
    • (2004) Magn Reson Med , vol.51 , pp. 353-361
    • Martirosian, P.1    Klose, U.2    Mader, I.3
  • 9
    • 7044263028 scopus 로고    scopus 로고
    • Renal disease: Value of functional magnetic resonance imaging with flow and perfusion measurements
    • Michaely HJ, Schoenberg SO, Ittrich C, et al. Renal disease: value of functional magnetic resonance imaging with flow and perfusion measurements. Invest Radiol. 2004;39:698-705.
    • (2004) Invest Radiol , vol.39 , pp. 698-705
    • Michaely, H.J.1    Schoenberg, S.O.2    Ittrich, C.3
  • 10
    • 67049136392 scopus 로고    scopus 로고
    • Strategies for reducing respiratory motion artifacts in renal perfusion imaging with arterial spin labeling
    • Robson PM, Madhuranthakam AJ, Dai W, et al. Strategies for reducing respiratory motion artifacts in renal perfusion imaging with arterial spin labeling. Magn Reson Med. 2009;61:1374-1387.
    • (2009) Magn Reson Med , vol.61 , pp. 1374-1387
    • Robson, P.M.1    Madhuranthakam, A.J.2    Dai, W.3
  • 11
    • 71049166862 scopus 로고    scopus 로고
    • Blood oxygen level-dependent and perfusion magnetic resonance imaging: Detecting differences in oxygen bioavailability and blood flow in transplanted kidneys
    • Sadowski EA, Djamali A, Wentland AL, et al. Blood oxygen level-dependent and perfusion magnetic resonance imaging: detecting differences in oxygen bioavailability and blood flow in transplanted kidneys. Magn Reson Imaging. 2010;28:56-64.
    • (2010) Magn Reson Imaging , vol.28 , pp. 56-64
    • Sadowski, E.A.1    Djamali, A.2    Wentland, A.L.3
  • 12
    • 0030954715 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging of human renal allografts during the post-transplant period: Preliminary observations
    • Szolar DH, Preidler K, Ebner F, et al. Functional magnetic resonance imaging of human renal allografts during the post-transplant period: preliminary observations. Magn Reson Imaging. 1997;15:727-735.
    • (1997) Magn Reson Imaging , vol.15 , pp. 727-735
    • Szolar, D.H.1    Preidler, K.2    Ebner, F.3
  • 13
    • 67849086690 scopus 로고    scopus 로고
    • Quantitative MR measures of intrarenal perfusion in the assessment of transplanted kidneys: Initial experience
    • Wentland AL, Sadowski EA, Djamali A, et al. Quantitative MR measures of intrarenal perfusion in the assessment of transplanted kidneys: initial experience. Acad Radiol. 2009;16:1077-1085.
    • (2009) Acad Radiol , vol.16 , pp. 1077-1085
    • Wentland, A.L.1    Sadowski, E.A.2    Djamali, A.3
  • 14
    • 0029052564 scopus 로고
    • The magnetic resonance renogram in renal transplant evaluation using dynamic contrast-enhanced MR imaging
    • Sharma RK, Gupta RK, Poptani H, et al. The magnetic resonance renogram in renal transplant evaluation using dynamic contrast-enhanced MR imaging. Transplantation. 1995;59:1405-1409.
    • (1995) Transplantation , vol.59 , pp. 1405-1409
    • Sharma, R.K.1    Gupta, R.K.2    Poptani, H.3
  • 15
    • 0031780598 scopus 로고    scopus 로고
    • Perfusion quantitation in transplanted rat kidney by MRI with arterial spin labeling
    • Wang JJ, Hendrich KS, Jackson EK, et al. Perfusion quantitation in transplanted rat kidney by MRI with arterial spin labeling. Kidney Int. 1998;53: 1783-1791.
    • (1998) Kidney Int , vol.53 , pp. 1783-1791
    • Wang, J.J.1    Hendrich, K.S.2    Jackson, E.K.3
  • 16
    • 68449085758 scopus 로고    scopus 로고
    • Morphologic and dynamic renal imaging with assessment of glomerular filtration rate in a pcy-mouse model using a clinical 3.0 Tesla scanner
    • Sadick M, Schock D, Kraenzlin B, et al. Morphologic and dynamic renal imaging with assessment of glomerular filtration rate in a pcy-mouse model using a clinical 3.0 Tesla scanner. Invest Radiol. 2009;44:469-475.
    • (2009) Invest Radiol , vol.44 , pp. 469-475
    • Sadick, M.1    Schock, D.2    Kraenzlin, B.3
  • 17
    • 77952089937 scopus 로고    scopus 로고
    • Quantification of renal allograft perfusion using arterial spin labeling MRI: Initial results
    • Lanzman RS, Wittsack HJ, Martirosian P, et al. Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results. Eur Radiol. 2010;20:1485-1491.
    • (2010) Eur Radiol , vol.20 , pp. 1485-1491
    • Lanzman, R.S.1    Wittsack, H.J.2    Martirosian, P.3
  • 18
    • 77950190399 scopus 로고    scopus 로고
    • Measurement of kidney perfusion by magnetic resonance imaging: Comparison of MRI with arterial spin labeling to para-aminohippuric acid plasma clearance in male subjects with metabolic syndrome
    • Ritt M, Janka R, Schneider MP, et al. Measurement of kidney perfusion by magnetic resonance imaging: comparison of MRI with arterial spin labeling to para-aminohippuric acid plasma clearance in male subjects with metabolic syndrome. Nephrol Dial Transplant. 2010;25:1126-1133.
    • (2010) Nephrol Dial Transplant , vol.25 , pp. 1126-1133
    • Ritt, M.1    Janka, R.2    Schneider, M.P.3
  • 19
    • 34547899897 scopus 로고    scopus 로고
    • Accuracy of blood flow values determined by arterial spin labeling: A validation study in isolated porcine kidneys
    • Warmuth C, Nagel S, Hegemann O, et al. Accuracy of blood flow values determined by arterial spin labeling: a validation study in isolated porcine kidneys. J Magn Reson Imaging. 2007;26:353-358.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 353-358
    • Warmuth, C.1    Nagel, S.2    Hegemann, O.3
  • 20
    • 70449288963 scopus 로고
    • Oxygen consumption and blood flow in the hypothermic, perfused kidney
    • Levy MN. Oxygen consumption and blood flow in the hypothermic, perfused kidney. Am J Physiol. 1959;197:1111-1114.
    • (1959) Am J Physiol , vol.197 , pp. 1111-1114
    • Levy, M.N.1
  • 21
    • 0037130746 scopus 로고    scopus 로고
    • Extension of borderzone myocardium in postinfarction dilated cardiomyopathy
    • discussion 1168-1171
    • Jackson BM, Gorman JH, Moainie SL, et al. Extension of borderzone myocardium in postinfarction dilated cardiomyopathy. J Am Coll Cardiol. 2002;40:1160-1167; discussion 1168-1171.
    • (2002) J Am Coll Cardiol , vol.40 , pp. 1160-1167
    • Jackson, B.M.1    Gorman, J.H.2    Moainie, S.L.3
  • 22
    • 0029060933 scopus 로고
    • Renal perfusion in humans: MR imaging with spin tagging of arterial water
    • Roberts DA, Detre JA, Bolinger L, et al. Renal perfusion in humans: MR imaging with spin tagging of arterial water. Radiology. 1995;196:281-286.
    • (1995) Radiology , vol.196 , pp. 281-286
    • Roberts, D.A.1    Detre, J.A.2    Bolinger, L.3
  • 23
    • 0036008752 scopus 로고    scopus 로고
    • Assessment of T1 and T2* effects in vivo and ex vivo using iron oxide nanoparticles in steady state- dependence on blood volume and water exchange
    • Bjornerud A, Johansson LO, Briley-Saebo K, et al. Assessment of T1 and T2* effects in vivo and ex vivo using iron oxide nanoparticles in steady state- dependence on blood volume and water exchange. Magn Reson Med. 2002; 47:461-471.
    • (2002) Magn Reson Med , vol.47 , pp. 461-471
    • Bjornerud, A.1    Johansson, L.O.2    Briley-Saebo, K.3
  • 24
    • 0033817185 scopus 로고    scopus 로고
    • Effect of restricted water exchange on cerebral blood flow values calculated with arterial spin tagging: A theoretical investigation
    • St Lawrence KS, Frank JA, McLaughlin AC. Effect of restricted water exchange on cerebral blood flow values calculated with arterial spin tagging: a theoretical investigation. Magn Reson Med. 2000;44:440-449.
    • (2000) Magn Reson Med , vol.44 , pp. 440-449
    • St Lawrence, K.S.1    Frank, J.A.2    McLaughlin, A.C.3
  • 25
    • 67651091583 scopus 로고    scopus 로고
    • Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent
    • Ludemann L, Nafz B, Elsner F, et al. Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent. Invest Radiol. 2009;44: 125-134.
    • (2009) Invest Radiol , vol.44 , pp. 125-134
    • Ludemann, L.1    Nafz, B.2    Elsner, F.3
  • 26
    • 33646708508 scopus 로고    scopus 로고
    • Renal hemodynamic responses to intrarenal infusion of acetylcholine: Comparison with effects of PGE2 and NO donor
    • Badzynska B, Sadowski J. Renal hemodynamic responses to intrarenal infusion of acetylcholine: comparison with effects of PGE2 and NO donor. Kidney Int. 2006;69:1774-1779.
    • (2006) Kidney Int , vol.69 , pp. 1774-1779
    • Badzynska, B.1    Sadowski, J.2
  • 27
    • 0034785375 scopus 로고    scopus 로고
    • Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function
    • Krier JD, Ritman EL, Bajzer Z, et al. Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function. Am J Physiol Renal Physiol. 2001;281:F630-F638.
    • (2001) Am J Physiol Renal Physiol , vol.281
    • Krier, J.D.1    Ritman, E.L.2    Bajzer, Z.3
  • 28
    • 0036047276 scopus 로고    scopus 로고
    • Effects of indomethacin on responses of regional kidney perfusion to vasoactive agents in rabbits
    • Oliver JJ, Rajapakse NW, Evans RG. Effects of indomethacin on responses of regional kidney perfusion to vasoactive agents in rabbits. Clin Exp Pharmacol Physiol. 2002;29:873-879.
    • (2002) Clin Exp Pharmacol Physiol , vol.29 , pp. 873-879
    • Oliver, J.J.1    Rajapakse, N.W.2    Evans, R.G.3
  • 29
    • 0026539684 scopus 로고
    • Influence of desflurane, isoflurane and halothane on regional tissue perfusion in dogs
    • Hartman JC, Pagel PS, Proctor LT, et al. Influence of desflurane, isoflurane and halothane on regional tissue perfusion in dogs. Can J Anaesth. 1992;39: 877-887.
    • (1992) Can J Anaesth , vol.39 , pp. 877-887
    • Hartman, J.C.1    Pagel, P.S.2    Proctor, L.T.3
  • 30
    • 0023226389 scopus 로고
    • Systemic distribution of blood flow in ponies during 1.45%, 1.96%, and 2.39% end-tidal isoflurane-O2 anesthesia
    • Manohar M, Gustafson R, Goetz TE, et al. Systemic distribution of blood flow in ponies during 1.45%, 1.96%, and 2.39% end-tidal isoflurane-O2 anesthesia. Am J Vet Res. 1987;48:1504-1510.
    • (1987) Am J Vet Res , vol.48 , pp. 1504-1510
    • Manohar, M.1    Gustafson, R.2    Goetz, T.E.3
  • 31
    • 0027231021 scopus 로고
    • Validation of fluorescent-labeled mi-crospheres for measurement of regional organ perfusion
    • Glenny RW, Bernard S, Brinkley M. Validation of fluorescent-labeled mi-crospheres for measurement of regional organ perfusion. J Appl Physiol. 1993;74:2585-2597.
    • (1993) J Appl Physiol , vol.74 , pp. 2585-2597
    • Glenny, R.W.1    Bernard, S.2    Brinkley, M.3
  • 32
    • 0033034679 scopus 로고    scopus 로고
    • Systemic and regional hemody-namics assessment in rats with fluorescent microspheres
    • Gervais M, Demolis P, Domergue V, et al. Systemic and regional hemody-namics assessment in rats with fluorescent microspheres. J Cardiovasc Pharmacol. 1999;33:425-432.
    • (1999) J Cardiovasc Pharmacol , vol.33 , pp. 425-432
    • Gervais, M.1    Demolis, P.2    Domergue, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.