메뉴 건너뛰기




Volumn 198, Issue 2, 2012, Pages 249-255

Imaging features and management of high-risk lesions on contrast-enhanced dynamic breast MRI

Author keywords

Biopsy; Breast; High risk; MRI

Indexed keywords

BREAST BIOPSY; BREAST CARCINOMA; BREAST HYPERPLASIA; BREAST LESION; BREAST PAPILLOMA; CANCER GRADING; CANCER MORPHOLOGY; CANCER RISK; CONTRAST ENHANCEMENT; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; ECHOGRAPHY; HIGH RISK PATIENT; HISTOPATHOLOGY; HUMAN; IMAGE ANALYSIS; INTRADUCTAL CARCINOMA; MALIGNANT TRANSFORMATION; MAMMOGRAPHY; MASTECTOMY; NUCLEAR MAGNETIC RESONANCE IMAGING; OUTCOME ASSESSMENT; PRACTICE GUIDELINE; PRIORITY JOURNAL; RADIATION INJURY; REVIEW; RISK ASSESSMENT; SCAR FORMATION; SYSTEMATIC REVIEW; TUMOR VOLUME;

EID: 84856118117     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.11.7610     Document Type: Review
Times cited : (46)

References (26)
  • 1
    • 77956942588 scopus 로고    scopus 로고
    • Controversies on the management of high-risk lesions at core biopsy from a radiology/pathology perspective
    • Georgian-Smith D, Lawton TJ. Controversies on the management of high-risk lesions at core biopsy from a radiology/pathology perspective. Radiol Clin North Am 2010; 48:999-1012
    • (2010) Radiol Clin North Am , vol.48 , pp. 999-1012
    • Georgian-Smith, D.1    Lawton, T.J.2
  • 2
    • 33644540773 scopus 로고    scopus 로고
    • Magnetic resonance-guided, vacuum-assisted breast biopsy: Results from a European multicenter study of 538 lesions
    • Perlet C, Heywang-Kobrunner SH, Heinig A, et al. Magnetic resonance-guided, vacuum-assisted breast biopsy: results from a European multicenter study of 538 lesions. Cancer 2006; 106:982-990
    • (2006) Cancer , vol.106 , pp. 982-990
    • Perlet, C.1    Heywang-Kobrunner, S.H.2    Heinig, A.3
  • 4
    • 79751530055 scopus 로고    scopus 로고
    • High-risk lesions diagnosed at MRI-guided vacuum-assisted breast biopsy: Can underestimation be predicted?
    • Crystal P, Sadaf A, Bukhanov K, McCready D, O'Malley F, Helbich TH. High-risk lesions diagnosed at MRI-guided vacuum-assisted breast biopsy: can underestimation be predicted? Eur Radiol 2011; 21:582-589
    • (2011) Eur Radiol , vol.21 , pp. 582-589
    • Crystal, P.1    Sadaf, A.2    Bukhanov, K.3    McCready, D.4    O'Malley, F.5    Helbich, T.H.6
  • 5
    • 77956804965 scopus 로고    scopus 로고
    • Frequency, upgrade rates, and characteristics of high-risk lesions initially identified with breast MRI
    • Strigel RM, Eby PR, Demartini WB, et al. Frequency, upgrade rates, and characteristics of high-risk lesions initially identified with breast MRI. AJR 2010; 195:792-798
    • (2010) AJR , vol.195 , pp. 792-798
    • Strigel, R.M.1    Eby, P.R.2    Demartini, W.B.3
  • 6
    • 33847220381 scopus 로고    scopus 로고
    • Underestimation of atypical ductal hyperplasia at MRI-guided 9-gauge vacuum-assisted breast biopsy
    • Liberman L, Holland AE, Marjan D, et al. Underestimation of atypical ductal hyperplasia at MRI-guided 9-gauge vacuum-assisted breast biopsy. AJR 2007; 188:684-690
    • (2007) AJR , vol.188 , pp. 684-690
    • Liberman, L.1    Holland, A.E.2    Marjan, D.3
  • 7
    • 76149091155 scopus 로고    scopus 로고
    • Factors that impact the duration of MRI-guided core needle biopsy
    • [web] W150-W17
    • Noroozian M, Gombos EC, Chikarmane S, et al. Factors that impact the duration of MRI-guided core needle biopsy. AJR 2010; 194:391; [web] W150-W17
    • (2010) AJR , vol.194 , pp. 391
    • Noroozian, M.1    Gombos, E.C.2    Chikarmane, S.3
  • 8
    • 79955107780 scopus 로고    scopus 로고
    • Borderline breast lesions: Diagnostic challenges and clinical implications
    • Masood S, Rosa M. Borderline breast lesions: diagnostic challenges and clinical implications. Adv Anat Pathol 2011; 18:190-198
    • (2011) Adv Anat Pathol , vol.18 , pp. 190-198
    • Masood, S.1    Rosa, M.2
  • 9
    • 29444453631 scopus 로고    scopus 로고
    • MR imaging-guided 9-gauge vacuum-assisted core-neddle breast biopsy: Initial experience
    • DOI 10.1148/radiol.2381050050
    • Orel SG, Rosen M, Mies C, Schnall MD. MR imaging-guided 9-gauge vacuum-assisted core-needle breast biopsy: initial experience. Radiology 2006; 238:54-61 (Pubitemid 43010580)
    • (2006) Radiology , vol.238 , Issue.1 , pp. 54-61
    • Orel, S.G.1    Rosen, M.2    Mies, C.3    Schnall, M.D.4
  • 11
    • 24644467383 scopus 로고    scopus 로고
    • MRI-guided 9-gauge vacuum-assisted breast biopsy: Initial clinical experience
    • Liberman L, Bracero N, Morris E, Thornton C, Dershaw DD. MRI-guided 9-gauge vacuum-assisted breast biopsy: initial clinical experience. AJR 2005; 185:183-193
    • (2005) AJR , vol.185 , pp. 183-193
    • Liberman, L.1    Bracero, N.2    Morris, E.3    Thornton, C.4    Dershaw, D.D.5
  • 12
    • 57149113615 scopus 로고    scopus 로고
    • Outcome of MRI-guided breast biopsy
    • Han BK, Schnall MD, Orel SG, Rosen M. Outcome of MRI-guided breast biopsy. AJR 2008; 191:1798-1804
    • (2008) AJR , vol.191 , pp. 1798-1804
    • Han, B.K.1    Schnall, M.D.2    Orel, S.G.3    Rosen, M.4
  • 13
    • 4444275728 scopus 로고    scopus 로고
    • Image-guided breast biopsy and management of high-risk lesions
    • DOI 10.1016/j.rcl.2004.04.002, PII S003383890400051X
    • Berg WA. Image-guided breast biopsy and management of high-risk lesions. Radiol Clin North Am 2004; 42:935-946 (Pubitemid 39165073)
    • (2004) Radiologic Clinics of North America , vol.42 , Issue.5 , pp. 935-946
    • Berg, W.A.1
  • 14
    • 1642400203 scopus 로고    scopus 로고
    • MRI-Guided Breast Biopsy: Clinical Experience with 14-Gauge Stainless Steel Core Biopsy Needle
    • Chen X, Lehman CD, Dee KE. MRI-guided breast biopsy: clinical experience with 14-gauge stainless steel core biopsy needle. AJR 2004; 182:1075-1080 (Pubitemid 38391678)
    • (2004) American Journal of Roentgenology , vol.182 , Issue.4 , pp. 1075-1080
    • Chen, X.1    Lehman, C.D.2    Dee, K.E.3
  • 16
    • 0021953918 scopus 로고
    • Atypical hyperplastic lesions of the female breast. A long-term follow-up study
    • DOI 10.1002/1097-0142(19850601)55:11<2698::AID-CNCR2820551127>3.0. CO;2-A
    • Page DL, Dupont WD, Rogers LW, Rados MS. Atypical hyperplastic lesions of the female breast: a long-term follow-up study. Cancer 1985; 55: 2698-2708 (Pubitemid 15092160)
    • (1985) Cancer , vol.55 , Issue.11 , pp. 2698-2708
    • Page, D.L.1    Dupont, W.D.2    Rogers, L.W.3    Rados, M.S.4
  • 17
    • 0026774198 scopus 로고
    • Combined histologic and cytologic criteria for the diagnosis of mammary atypical ductal hyperplasia
    • Page DL, Rogers LW. Combined histologic and cytologic criteria for the diagnosis of mammary atypical ductal hyperplasia. Hum Pathol 1992; 23:1095-1097
    • (1992) Hum Pathol , vol.23 , pp. 1095-1097
    • Page, D.L.1    Rogers, L.W.2
  • 18
    • 77954818993 scopus 로고    scopus 로고
    • Vacuum-assisted biopsies under MR guidance: Results of 72 procedures
    • Malhaire C, El Khoury C, Thibault F, et al. Vacuum-assisted biopsies under MR guidance: results of 72 procedures. Eur Radiol 2010; 20:1554-1562
    • (2010) Eur Radiol , vol.20 , pp. 1554-1562
    • Malhaire, C.1    El Khoury, C.2    Thibault, F.3
  • 19
    • 53549131704 scopus 로고    scopus 로고
    • Initial clinical experience with a new MRI vacuum-assisted breast biopsy device
    • Mahoney MC. Initial clinical experience with a new MRI vacuum-assisted breast biopsy device. J Magn Reson Imaging 2008; 28:900-905
    • (2008) J Magn Reson Imaging , vol.28 , pp. 900-905
    • Mahoney, M.C.1
  • 20
    • 57549101920 scopus 로고    scopus 로고
    • The management of papillary lesion of the breast by core needle biopsy
    • Tseng HS, Chen YL, Chen ST, et al. The management of papillary lesion of the breast by core needle biopsy. Eur J Surg Oncol 2009; 35:21-24
    • (2009) Eur J Surg Oncol , vol.35 , pp. 21-24
    • Tseng, H.S.1    Chen, Y.L.2    Chen, S.T.3
  • 21
    • 33750541696 scopus 로고    scopus 로고
    • Magnetic resonance-guided biopsy of suspicious breast lesions with a handheld vacuum biopsy device
    • DOI 10.1080/02841850600892928, PII J6170K01G2877437
    • Gebauer B, Bostanjoglo M, Moesta KT, Schneider W, Schlag PM, Felix R. Magnetic resonance-guided biopsy of suspicious breast lesions with a handheld vacuum biopsy device. Acta Radiol 2006; 47:907-913 (Pubitemid 44673494)
    • (2006) Acta Radiologica , vol.47 , Issue.9 , pp. 907-913
    • Gebauer, B.1    Bostanjoglo, M.2    Moesta, K.T.3    Schneider, W.4    Schlag, P.M.5    Felix, R.6
  • 24
    • 79551542844 scopus 로고    scopus 로고
    • Magnetic resonance imaging of intraductal papillomas of the breast
    • Tominaga J, Hama H, Kimura N, Takahashi S. Magnetic resonance imaging of intraductal papillomas of the breast. J Comput Assist Tomogr 2011; 35:153-157
    • (2011) J Comput Assist Tomogr , vol.35 , pp. 153-157
    • Tominaga, J.1    Hama, H.2    Kimura, N.3    Takahashi, S.4
  • 26
    • 33745485613 scopus 로고    scopus 로고
    • MRI-guided vacuum-assisted breast biopsy with a handheld portable biopsy system
    • DOI 10.2214/AJR.05.0551
    • Ghate SV, Rosen EL, Soo MS, Baker JA. MRI-guided vacuum-assisted breast biopsy with a handheld portable biopsy system. AJR 2006; 186:1733-1736 (Pubitemid 46112540)
    • (2006) American Journal of Roentgenology , vol.186 , Issue.6 , pp. 1733-1736
    • Ghate, S.V.1    Rosen, E.L.2    Soo, M.S.C.3    Baker, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.