메뉴 건너뛰기




Volumn 25, Issue 2, 2012, Pages 279-285

Quantification of water exchange kinetics for targeted PARACEST perfluorocarbon nanoparticles

Author keywords

Fibrin; Fluorine; Nanoparticle; PARACEST

Indexed keywords

ATHEROSCLEROTIC PLAQUE; BACKGROUND SIGNALS; BOUND WATERS; CONTRAST AGENT; CONTRAST TO NOISE RATIO; DETECTION LIMITS; FIBRIN; IMAGE CONTRASTS; IN-VITRO; MATHEMATICAL MODELING; MOLECULAR IMAGING; NANOPARTICLE SURFACE; PARACEST; PARAMAGNETIC CHEMICAL-EXCHANGE-SATURATION- TRANSFERS; PARTICLE BINDING; PERFLUOROCARBONS; PHANTOM EXPERIMENT; SIGNAL INTENSITIES; SMALL MOLECULES; TARGET SURFACE; WATER EXCHANGE;

EID: 84856022354     PISSN: 09523480     EISSN: 10991492     Source Type: Journal    
DOI: 10.1002/nbm.1746     Document Type: Article
Times cited : (10)

References (28)
  • 1
    • 0034145982 scopus 로고    scopus 로고
    • A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST)
    • Ward KM, Aletras AH, Balaban RS. A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST). J. Magn. Reson. 2000; 143(1): 79-87.
    • (2000) J. Magn. Reson. , vol.143 , Issue.1 , pp. 79-87
    • Ward, K.M.1    Aletras, A.H.2    Balaban, R.S.3
  • 3
    • 0141670309 scopus 로고    scopus 로고
    • Supramolecular adducts between poly-L-arginine and [TmIIIdotp]: a route to sensitivity-enhanced magnetic resonance imaging-chemical exchange saturation transfer agents
    • Aime S, Delli Castelli D, Terreno E. Supramolecular adducts between poly-L-arginine and [TmIIIdotp]: a route to sensitivity-enhanced magnetic resonance imaging-chemical exchange saturation transfer agents. Angew. Chem. Int. Ed Engl. 2003; 42(37): 4527-4529.
    • (2003) Angew. Chem. Int. Ed Engl. , vol.42 , Issue.37 , pp. 4527-4529
    • Aime, S.1    Delli Castelli, D.2    Terreno, E.3
  • 4
    • 70350049069 scopus 로고    scopus 로고
    • Tracking the relative in vivo pharmacokinetics of nanoparticles with PARACEST MRI
    • Ali MM, Yoo B, Pagel MD. Tracking the relative in vivo pharmacokinetics of nanoparticles with PARACEST MRI. Mol. Pharm. 2009; 6(5): 1409-1416.
    • (2009) Mol. Pharm. , vol.6 , Issue.5 , pp. 1409-1416
    • Ali, M.M.1    Yoo, B.2    Pagel, M.D.3
  • 5
    • 54249120416 scopus 로고    scopus 로고
    • Polymeric PARACEST agents for enhancing MRI contrast sensitivity
    • Wu Y, Zhou Y, Ouari O, Woods M, Zhao P, Soesbe TC et al. Polymeric PARACEST agents for enhancing MRI contrast sensitivity. J. Am. Chem. Soc. 2008; 130(42): 13854-13855.
    • (2008) J. Am. Chem. Soc. , vol.130 , Issue.42 , pp. 13854-13855
    • Wu, Y.1    Zhou, Y.2    Ouari, O.3    Woods, M.4    Zhao, P.5    Soesbe, T.C.6
  • 6
    • 33845259382 scopus 로고    scopus 로고
    • Targeted PARACEST nanoparticle contrast agent for the detection of fibrin
    • Winter PM, Cai K, Chen J, Adair CR, Kiefer GE, Athey PS et al. Targeted PARACEST nanoparticle contrast agent for the detection of fibrin. Magn. Reson. Med. 2006; 56(6): 1384-1388.
    • (2006) Magn. Reson. Med. , vol.56 , Issue.6 , pp. 1384-1388
    • Winter, P.M.1    Cai, K.2    Chen, J.3    Adair, C.R.4    Kiefer, G.E.5    Athey, P.S.6
  • 7
    • 10044277164 scopus 로고    scopus 로고
    • Quantitative "magnetic resonance immunohistochemistry" with ligand-targeted (19)F nanoparticles
    • Morawski AM, Winter PM, Yu X, Fuhrhop RW, Scott MJ, Hockett F et al. Quantitative "magnetic resonance immunohistochemistry" with ligand-targeted (19)F nanoparticles. Magn. Reson. Med. 2004; 52(6): 1255-1262.
    • (2004) Magn. Reson. Med. , vol.52 , Issue.6 , pp. 1255-1262
    • Morawski, A.M.1    Winter, P.M.2    Yu, X.3    Fuhrhop, R.W.4    Scott, M.J.5    Hockett, F.6
  • 10
    • 16444362041 scopus 로고    scopus 로고
    • Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI
    • Woessner DE, Zhang S, Merritt ME, Sherry AD. Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI. Magn. Reson. Med. 2005; 53(4): 790-799.
    • (2005) Magn. Reson. Med. , vol.53 , Issue.4 , pp. 790-799
    • Woessner, D.E.1    Zhang, S.2    Merritt, M.E.3    Sherry, A.D.4
  • 11
    • 0035845635 scopus 로고    scopus 로고
    • Novel MRI contrast agent for molecular imaging of fibrin: implications for detecting vulnerable plaques
    • Flacke S, Fischer S, Scott MJ, Fuhrhop RJ, Allen JS, McLean M et al. Novel MRI contrast agent for molecular imaging of fibrin: implications for detecting vulnerable plaques. Circulation 2001; 104(11): 1280-1285.
    • (2001) Circulation , vol.104 , Issue.11 , pp. 1280-1285
    • Flacke, S.1    Fischer, S.2    Scott, M.J.3    Fuhrhop, R.J.4    Allen, J.S.5    McLean, M.6
  • 12
    • 1642351484 scopus 로고    scopus 로고
    • Ln(III)-DOTAMGly complexes: a versatile series to assess the determinants of the efficacy of paramagnetic chemical exchange saturation transfer agents for magnetic resonance imaging applications
    • Terreno E, Castelli DD, Cravotto G, Milone L, Aime S. Ln(III)-DOTAMGly complexes: a versatile series to assess the determinants of the efficacy of paramagnetic chemical exchange saturation transfer agents for magnetic resonance imaging applications. Invest. Radiol. 2004; 39(4): 235-243.
    • (2004) Invest. Radiol. , vol.39 , Issue.4 , pp. 235-243
    • Terreno, E.1    Castelli, D.D.2    Cravotto, G.3    Milone, L.4    Aime, S.5
  • 13
    • 11144304106 scopus 로고    scopus 로고
    • Engineering lanthanide complexes with controlled water exchange rates for magnetic resonance imaging
    • Woods M, Sherry AD. Engineering lanthanide complexes with controlled water exchange rates for magnetic resonance imaging. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2004; 7: 5254-5257.
    • (2004) Conf. Proc. IEEE Eng. Med. Biol. Soc. , vol.7 , pp. 5254-5257
    • Woods, M.1    Sherry, A.D.2
  • 14
    • 24144459532 scopus 로고    scopus 로고
    • Fine-tuning water exchange on Gd(III) poly(amino carboxylates) by modulation of steric crowding
    • Jaszberenyi Z, Sour A, Toth E, Benmelouka M, Merbach AE. Fine-tuning water exchange on Gd(III) poly(amino carboxylates) by modulation of steric crowding. Dalton Trans. 2005; (16): 2713-2719.
    • (2005) Dalton Trans. , Issue.16 , pp. 2713-2719
    • Jaszberenyi, Z.1    Sour, A.2    Toth, E.3    Benmelouka, M.4    Merbach, A.E.5
  • 15
    • 0347694632 scopus 로고    scopus 로고
    • Lanthanide (III) complexes of novel mixed carboxylic-phosphorus acid derivatives of diethylenetriamine: a step towards more efficient MRI contrast agents
    • Kotek J, Lebduskova P, Hermann P, Vander Elst L, Muller RN, Geraldes CF et al. Lanthanide (III) complexes of novel mixed carboxylic-phosphorus acid derivatives of diethylenetriamine: a step towards more efficient MRI contrast agents. Chemistry 2003; 9(23): 5899-5915.
    • (2003) Chemistry , vol.9 , Issue.23 , pp. 5899-5915
    • Kotek, J.1    Lebduskova, P.2    Hermann, P.3    Vander Elst, L.4    Muller, R.N.5    Geraldes, C.F.6
  • 16
    • 0042967705 scopus 로고    scopus 로고
    • GdIII complexes with fast water exchange and high thermodynamic stability: potential building blocks for high-relaxivity MRI contrast agents
    • Laus S, Ruloff R, Toth E, Merbach AE. GdIII complexes with fast water exchange and high thermodynamic stability: potential building blocks for high-relaxivity MRI contrast agents. Chemistry 2003; 9(15): 3555-3566.
    • (2003) Chemistry , vol.9 , Issue.15 , pp. 3555-3566
    • Laus, S.1    Ruloff, R.2    Toth, E.3    Merbach, A.E.4
  • 17
    • 11844280273 scopus 로고    scopus 로고
    • Synthesis of a bifunctional monophosphinic acid DOTA analogue ligand and its lanthanide(III) complexes. A gadolinium(III) complex endowed with an optimal water exchange rate for MRI applications
    • Rudovsky J, Kotek J, Hermann P, Lukes I, Mainero V, Aime S. Synthesis of a bifunctional monophosphinic acid DOTA analogue ligand and its lanthanide(III) complexes. A gadolinium(III) complex endowed with an optimal water exchange rate for MRI applications. Org. Biomol. Chem. 2005; 3(1): 112-117.
    • (2005) Org. Biomol. Chem. , vol.3 , Issue.1 , pp. 112-117
    • Rudovsky, J.1    Kotek, J.2    Hermann, P.3    Lukes, I.4    Mainero, V.5    Aime, S.6
  • 20
    • 0030760503 scopus 로고    scopus 로고
    • Towards MRI contrast agents of improved efficacy. NMR relaxometric investigations of the binding interaction to HSA of a novel heptadentate macrocyclic triphosphonate Gd(III)-complex
    • Aime S, Botta M, Crich SG, Giovenzana GB, Pagliarin R, Piccinini M et al. Towards MRI contrast agents of improved efficacy. NMR relaxometric investigations of the binding interaction to HSA of a novel heptadentate macrocyclic triphosphonate Gd(III)-complex J. Biol. Inorg. Chem. 1997; 2: 470-479.
    • (1997) J. Biol. Inorg. Chem. , vol.2 , pp. 470-479
    • Aime, S.1    Botta, M.2    Crich, S.G.3    Giovenzana, G.B.4    Pagliarin, R.5    Piccinini, M.6
  • 21
    • 0000866324 scopus 로고    scopus 로고
    • Gd(III) complexes as contrast agents for magnetic resonance imaging: a proton relaxation enhancement study of the interaction with human serum albumin
    • Aime S, Botta M, Fasano M, Crich SG, Terreno E. Gd(III) complexes as contrast agents for magnetic resonance imaging: a proton relaxation enhancement study of the interaction with human serum albumin J. Biol. Inorg. Chem. 1996; 1: 312-319.
    • (1996) J. Biol. Inorg. Chem. , vol.1 , pp. 312-319
    • Aime, S.1    Botta, M.2    Fasano, M.3    Crich, S.G.4    Terreno, E.5
  • 22
    • 0032714162 scopus 로고    scopus 로고
    • Contrast agents for magnetic resonance angiographic applications: 1H and 17O NMR relaxometric investigations on two gadolinium(III) DTPA-like chelates endowed with high binding affinity to human serum albumin
    • Aime S, Chiaussa M, Digilio G, Gianolio E, Terreno E. Contrast agents for magnetic resonance angiographic applications: 1H and 17O NMR relaxometric investigations on two gadolinium(III) DTPA-like chelates endowed with high binding affinity to human serum albumin. J. Biol. Inorg. Chem. 1999; 4(6): 766-774.
    • (1999) J. Biol. Inorg. Chem. , vol.4 , Issue.6 , pp. 766-774
    • Aime, S.1    Chiaussa, M.2    Digilio, G.3    Gianolio, E.4    Terreno, E.5
  • 23
    • 21044444021 scopus 로고    scopus 로고
    • New insights for pursuing high relaxivity MRI agents from modelling the binding interaction of Gd(III) chelates to HSA
    • Aime S, Gianolio E, Longo D, Pagliarin R, Lovazzano C, Sisti M. New insights for pursuing high relaxivity MRI agents from modelling the binding interaction of Gd(III) chelates to HSA. Chembiochem 2005; 6(5): 818-820.
    • (2005) Chembiochem , vol.6 , Issue.5 , pp. 818-820
    • Aime, S.1    Gianolio, E.2    Longo, D.3    Pagliarin, R.4    Lovazzano, C.5    Sisti, M.6
  • 24
    • 0037181390 scopus 로고    scopus 로고
    • The interaction of MS-325 with human serum albumin and its effect on proton relaxation rates
    • Caravan P, Cloutier NJ, Greenfield MT, McDermid SA, Dunham SU, Bulte JW et al. The interaction of MS-325 with human serum albumin and its effect on proton relaxation rates. J Am Chem Soc 2002; 124(12): 3152-3162.
    • (2002) J Am Chem Soc , vol.124 , Issue.12 , pp. 3152-3162
    • Caravan, P.1    Cloutier, N.J.2    Greenfield, M.T.3    McDermid, S.A.4    Dunham, S.U.5    Bulte, J.W.6
  • 26
    • 29344462452 scopus 로고    scopus 로고
    • MRI thermometry based on PARACEST agents
    • Zhang S, Malloy CR, Sherry AD. MRI thermometry based on PARACEST agents. J. Am. Chem. Soc. 2005; 127(50): 17572-17573.
    • (2005) J. Am. Chem. Soc. , vol.127 , Issue.50 , pp. 17572-17573
    • Zhang, S.1    Malloy, C.R.2    Sherry, A.D.3
  • 27
    • 0036204319 scopus 로고    scopus 로고
    • Paramagnetic lanthanide(III) complexes as pH-sensitive chemical exchange saturation transfer (CEST) contrast agents for MRI applications
    • Aime S, Barge A, Delli Castelli D, Fedeli F, Mortillaro A et al. Paramagnetic lanthanide(III) complexes as pH-sensitive chemical exchange saturation transfer (CEST) contrast agents for MRI applications. Magn. Reson. Med. 2002; 47(4): 639-648.
    • (2002) Magn. Reson. Med. , vol.47 , Issue.4 , pp. 639-648
    • Aime, S.1    Barge, A.2    Delli Castelli, D.3    Fedeli, F.4    Mortillaro, A.5
  • 28
    • 36849044069 scopus 로고    scopus 로고
    • Design and characterization of a new irreversible responsive PARACEST MRI contrast agent that detects nitric oxide
    • Liu G, Li Y, Pagel MD. Design and characterization of a new irreversible responsive PARACEST MRI contrast agent that detects nitric oxide. Magn Reson Med 2007; 58(6): 1249-1256.
    • (2007) Magn Reson Med , vol.58 , Issue.6 , pp. 1249-1256
    • Liu, G.1    Li, Y.2    Pagel, M.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.