메뉴 건너뛰기




Volumn 35, Issue 1, 2012, Pages 35-38

A new modified fluorescein strip: Its repeatability and usefulness in tear film break-up time analysis

Author keywords

Break up time; Dry eye; Fluorescein; Nibut; Tearfilm

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; DRY EYE; FEMALE; FILTER; FLUORESCEIN STRIP; FLUORESCENCE ANALYSIS; HUMAN; IN VITRO STUDY; IN VIVO STUDY; INSTRUMENT; MALE; OBSERVER VARIATION; PRIORITY JOURNAL; SCORING SYSTEM; TEAR FILM; TEARSCOPE; ULTRAVIOLET RADIATION;

EID: 84855947129     PISSN: 13670484     EISSN: 14765411     Source Type: Journal    
DOI: 10.1016/j.clae.2011.07.005     Document Type: Article
Times cited : (30)

References (20)
  • 1
    • 0014706724 scopus 로고
    • The precorneal tear film I. Factors in spreading and maintaining a continuous tear film over the corneal surface
    • Lemp M.A., Holly F.J., Iwata S., Dohlman C.H. The precorneal tear film I. Factors in spreading and maintaining a continuous tear film over the corneal surface. Arch Ophthalmol 1970, 83(1):89-94.
    • (1970) Arch Ophthalmol , vol.83 , Issue.1 , pp. 89-94
    • Lemp, M.A.1    Holly, F.J.2    Iwata, S.3    Dohlman, C.H.4
  • 2
    • 34347256116 scopus 로고    scopus 로고
    • Methodologies to diagnose and monitor dry eye disease: Report of the Diagnostic Methodology Subcommittee of the International Dry Eye WorkShop (2007)
    • Bron A.J., Bron A.J., Abelson M.B., Ousler G., Pearce E., Tomlinson A., et al. Methodologies to diagnose and monitor dry eye disease: Report of the Diagnostic Methodology Subcommittee of the International Dry Eye WorkShop (2007). Ocul Surf 2007, 5(2):108-152.
    • (2007) Ocul Surf , vol.5 , Issue.2 , pp. 108-152
    • Bron, A.J.1    Bron, A.J.2    Abelson, M.B.3    Ousler, G.4    Pearce, E.5    Tomlinson, A.6
  • 3
    • 70349098116 scopus 로고    scopus 로고
    • A novel method to predict dry eye symptoms in new contact lens wearers
    • Pult H., Murphy P.J., Purslow C. A novel method to predict dry eye symptoms in new contact lens wearers. Optim Vis Sci 2009, 86(9):E1042-E1050.
    • (2009) Optim Vis Sci , vol.86 , Issue.9
    • Pult, H.1    Murphy, P.J.2    Purslow, C.3
  • 4
    • 79954466389 scopus 로고    scopus 로고
    • The relationship between clinical signs and dry eye symptoms
    • Pult H., Purslow C., Murphy P.J. The relationship between clinical signs and dry eye symptoms. Eye (Lond) 2011, 25(4):502-510.
    • (2011) Eye (Lond) , vol.25 , Issue.4 , pp. 502-510
    • Pult, H.1    Purslow, C.2    Murphy, P.J.3
  • 5
    • 0027974187 scopus 로고
    • The European-Community Study-Group on diagnostic-criteria for Sjogrens-Syndrome: sensitivity and specificity of tests for ocular and oral involvement in Sjogrens-Syndrome
    • Vitali C., Moutsopoulos H.M., Bombardieri S., Bencivelli W., Chiellini S., Devita S., et al. The European-Community Study-Group on diagnostic-criteria for Sjogrens-Syndrome: sensitivity and specificity of tests for ocular and oral involvement in Sjogrens-Syndrome. Ann Rheum Dis 1994, 53(10):637-647.
    • (1994) Ann Rheum Dis , vol.53 , Issue.10 , pp. 637-647
    • Vitali, C.1    Moutsopoulos, H.M.2    Bombardieri, S.3    Bencivelli, W.4    Chiellini, S.5    Devita, S.6
  • 6
    • 0022531113 scopus 로고
    • Non-invasive tear film break-up time: sensitivity and specificity
    • Mengher L.S., Pandher K.S., Bron A.J. Non-invasive tear film break-up time: sensitivity and specificity. Acta Ophthalmol (Copenh) 1986, 64(4):441-444.
    • (1986) Acta Ophthalmol (Copenh) , vol.64 , Issue.4 , pp. 441-444
    • Mengher, L.S.1    Pandher, K.S.2    Bron, A.J.3
  • 7
    • 25844432854 scopus 로고    scopus 로고
    • The Effect of instilled fluorescein solution volume on the values and repeatability of TBUT measurements
    • Johnson M.E., Murphy P.J. The Effect of instilled fluorescein solution volume on the values and repeatability of TBUT measurements. Cornea 2005, 24(7):811-817.
    • (2005) Cornea , vol.24 , Issue.7 , pp. 811-817
    • Johnson, M.E.1    Murphy, P.J.2
  • 8
    • 0022527299 scopus 로고
    • Experimental contamination of minims of fluorescein by Pseudomonas aeruginosa
    • Claoue C. Experimental contamination of minims of fluorescein by Pseudomonas aeruginosa. Br J Ophthalmol 1986, 70(7):507-509.
    • (1986) Br J Ophthalmol , vol.70 , Issue.7 , pp. 507-509
    • Claoue, C.1
  • 9
    • 75449099489 scopus 로고    scopus 로고
    • The reuse of opthalmic minims: an unacceptable cross-infection risk?
    • Rautenbach P., Wilson A., Gouws P. The reuse of opthalmic minims: an unacceptable cross-infection risk?. Eye (Lond) 2010, 24(1):50-52.
    • (2010) Eye (Lond) , vol.24 , Issue.1 , pp. 50-52
    • Rautenbach, P.1    Wilson, A.2    Gouws, P.3
  • 10
    • 0034752799 scopus 로고    scopus 로고
    • Comparison of fluorescein break-up time measurement reproducibility using standard fluorescein strips versus the dry eye test (DET) method
    • Korb D.R., Greiner J.V., Herman J. Comparison of fluorescein break-up time measurement reproducibility using standard fluorescein strips versus the dry eye test (DET) method. Cornea 2001, 20(8):811-815.
    • (2001) Cornea , vol.20 , Issue.8 , pp. 811-815
    • Korb, D.R.1    Greiner, J.V.2    Herman, J.3
  • 11
    • 0021990427 scopus 로고
    • Effect of fluorescein instillation on the pre-corneal tear film stability
    • Mengher L.S., Bron A.J., Tonge S.R., Gilbert D.J. Effect of fluorescein instillation on the pre-corneal tear film stability. Curr Eye Res 1985, 4(1):9-12.
    • (1985) Curr Eye Res , vol.4 , Issue.1 , pp. 9-12
    • Mengher, L.S.1    Bron, A.J.2    Tonge, S.R.3    Gilbert, D.J.4
  • 12
    • 0021993196 scopus 로고
    • A non-invasive instrument for clinical assessment of the pre-corneal tear film stability
    • Mengher L.S., Bron A.J., Tonge S.R., Gilbert D.J. A non-invasive instrument for clinical assessment of the pre-corneal tear film stability. Curr Eye Res 1985, 4(1):1-7.
    • (1985) Curr Eye Res , vol.4 , Issue.1 , pp. 1-7
    • Mengher, L.S.1    Bron, A.J.2    Tonge, S.R.3    Gilbert, D.J.4
  • 13
    • 84855973255 scopus 로고    scopus 로고
    • Validation of an objective non-invasive method for a qualitative tear film assessment using a corneal topographer
    • Academy.
    • Wiedemann, D,W. Sickenberger, M. Michel, and S. Marx. Validation of an objective non-invasive method for a qualitative tear film assessment using a corneal topographer. Academy, 2010.
    • (2010)
    • Wiedemann, D.W.1    Sickenberger, M.2    Michel, S.M.3
  • 14
    • 84855932207 scopus 로고    scopus 로고
    • Development and realization of a non-invasive method for tear film assessment by using a corneal topographer
    • in Academy.
    • Wiedemann, D, W. Sickenberger, M. Michel, and S. Marx. Development and realization of a non-invasive method for tear film assessment by using a corneal topographer. in Academy 2010.
    • (2010)
    • Wiedemann, D.W.1    Sickenberger, M.2    Michel, S.M.3
  • 15
    • 0002259415 scopus 로고    scopus 로고
    • Analysis of the repeatability of tear break-up time measurement techniques on asymptomatic subjects before: during and after contact lens wear
    • Elliott M., Fandrich H., Simpson T., Fonn D. Analysis of the repeatability of tear break-up time measurement techniques on asymptomatic subjects before: during and after contact lens wear. Contact Lens Anterior Eye 1998, 21(4):98-103.
    • (1998) Contact Lens Anterior Eye , vol.21 , Issue.4 , pp. 98-103
    • Elliott, M.1    Fandrich, H.2    Simpson, T.3    Fonn, D.4
  • 16
    • 7644240616 scopus 로고    scopus 로고
    • Tear film stability analysis system: introducing a new application for videokeratography
    • Goto T., Zheng X., Okamoto S., Ohashi Y. Tear film stability analysis system: introducing a new application for videokeratography. Cornea 2004, 23(Suppl. 8):S65-S70.
    • (2004) Cornea , vol.23 , Issue.SUPPL. 8
    • Goto, T.1    Zheng, X.2    Okamoto, S.3    Ohashi, Y.4
  • 17
  • 18
    • 78649970628 scopus 로고    scopus 로고
    • Simultaneous examination of tear film break-up and the lipid layer of the human eye: a novel sensor design (Part 1)
    • Arnold S., Walter A., Eppig T., Bruenner H., Langenbucher A. Simultaneous examination of tear film break-up and the lipid layer of the human eye: a novel sensor design (Part 1). Z Med Phys 2010, 20(4):309-315.
    • (2010) Z Med Phys , vol.20 , Issue.4 , pp. 309-315
    • Arnold, S.1    Walter, A.2    Eppig, T.3    Bruenner, H.4    Langenbucher, A.5
  • 19
    • 84855973252 scopus 로고    scopus 로고
    • Grading of lid-parallel conjunctival folds by novice and experienced observers
    • Pult H., Riede-Pult B. Grading of lid-parallel conjunctival folds by novice and experienced observers. Invest Ophthalmol Vis Sci 2011, 52(6):3739.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , Issue.6 , pp. 3739
    • Pult, H.1    Riede-Pult, B.2
  • 20
    • 0036921853 scopus 로고    scopus 로고
    • The repeatability of diagnostic tests and surveys in dry eye
    • Nichols K.K., Zadnik K. The repeatability of diagnostic tests and surveys in dry eye. Adv Exp Med Biol 2002, 506(Pt B):1171-1175.
    • (2002) Adv Exp Med Biol , vol.506 , Issue.PART B , pp. 1171-1175
    • Nichols, K.K.1    Zadnik, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.