-
1
-
-
0942279683
-
The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears
-
L.M. Galatz, C.M. Ball, S.A. Teefey, W.D. Middleton, K. Yamaguchi The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears J Bone Joint Surg Am 86 2004 219 224 (Pubitemid 38141554)
-
(2004)
Journal of Bone and Joint Surgery - Series A
, vol.86
, Issue.2
, pp. 219-224
-
-
Galatz, L.M.1
Ball, C.M.2
Teefey, S.A.3
Middleton, W.D.4
Yamaguchi, K.5
-
3
-
-
0026015275
-
Repairs of the rotator cuff Correlation of functional results with integrity of the cuff
-
D.T. Harryman, L.A. Mack, K.Y. Wang, S.E. Jackins, M.L. Richardson, F.A. Matsen III Repairs of the rotator cuff Correlation of functional results with integrity of the cuff J Bone Joint Surg Am 73 1991 982 989
-
(1991)
J Bone Joint Surg Am
, vol.73
, pp. 982-989
-
-
Harryman, D.T.1
MacK, L.A.2
Wang, K.Y.3
Jackins, S.E.4
Richardson, M.L.5
Matsen Iii, F.A.6
-
5
-
-
28444453275
-
Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: Single-row versus dual-row fixation
-
DOI 10.1016/j.arthro.2005.08.011, PII S0749806305011758
-
H. Sugaya, K. Maeda, K. Matsuki, J. Moriishi Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: Single-row versus dual-row fixation Arthroscopy 21 2005 1307 1316 (Pubitemid 41735195)
-
(2005)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.21
, Issue.11
, pp. 1307-1316
-
-
Sugaya, H.1
Maeda, K.2
Matsuki, K.3
Moriishi, J.4
-
6
-
-
0001844833
-
Anatomical results of rotator cuff repairs Study of 57 cases controlled by arthrography
-
(abstract)
-
J.M. Postel, D. Goutallier, L. Lavau, J. Bernageau Anatomical results of rotator cuff repairs Study of 57 cases controlled by arthrography J Shoulder Elbow Surg 3 1994 20 (abstract)
-
(1994)
J Shoulder Elbow Surg
, vol.3
, pp. 20
-
-
Postel, J.M.1
Goutallier, D.2
Lavau, L.3
Bernageau, J.4
-
7
-
-
32944480447
-
Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair
-
DOI 10.1177/0363546505281238
-
D.H. Kim, N.S. Elattrache, J.E. Tibone Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair Am J Sports Med 34 2006 407 414 (Pubitemid 43260577)
-
(2006)
American Journal of Sports Medicine
, vol.34
, Issue.3
, pp. 407-414
-
-
Kim, D.H.1
ElAttrache, N.S.2
Tibone, J.E.3
Jun, B.-J.4
DeLaMora, S.N.5
Kvitne, R.S.6
Lee, T.Q.7
-
8
-
-
31844453610
-
Biomechanical evaluation of arthroscopic rotator cuff repairs: Double-row compared with single-row fixation
-
DOI 10.2106/JBJS.D.02887
-
C.B. Ma, L. Comerford, J. Wilson, C.M. Puttlitz Biomechanical evaluation of arthroscopic rotator cuff repairs: Double-row compared with single-row fixation J Bone Joint Surg Am 88 2006 403 410 (Pubitemid 43185144)
-
(2006)
Journal of Bone and Joint Surgery - Series A
, vol.88
, Issue.2
, pp. 403-410
-
-
Ma, C.B.1
Comerford, L.2
Wilson, J.3
Puttlitz, C.M.4
-
9
-
-
33750442166
-
The effect of double-row fixation on initial repair strength in rotator cuff repair: A biomechanical study
-
DOI 10.1016/j.arthro.2006.07.004, PII S0749806306008772
-
S.W. Meier, J.D. Meier The effect of double-row fixation on initial repair strength in rotator cuff repair: A biomechanical study Arthroscopy 22 2006 1168 1173 (Pubitemid 44648672)
-
(2006)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.22
, Issue.11
, pp. 1168-1173
-
-
Meier, S.W.1
Meier, J.D.2
-
10
-
-
0038795070
-
Rotator cuff repair: A biomechanical comparison of three techniques
-
R.L. Waltrip, N. Zheng, J.R. Dugas, J.R. Andrews Rotator cuff repair A biomechanical comparison of three techniques Am J Sports Med 31 2003 493 497 (Pubitemid 36875378)
-
(2003)
American Journal of Sports Medicine
, vol.31
, Issue.4
, pp. 493-497
-
-
Waltrip, R.L.1
Zheng, N.2
Dugas, J.R.3
Andrews, J.R.4
-
11
-
-
70649106221
-
Comparative evaluation of the tendon-bone interface contact pressure in different single- versus double-row suture anchor repair techniques
-
M.H. Baums, G. Spahn, H. Steckel, A. Fischer, W. Schultz, H.M. Klinger Comparative evaluation of the tendon-bone interface contact pressure in different single- versus double-row suture anchor repair techniques Knee Surg Sports Traumatol Arthrosc 17 2009 1466 1472
-
(2009)
Knee Surg Sports Traumatol Arthrosc
, vol.17
, pp. 1466-1472
-
-
Baums, M.H.1
Spahn, G.2
Steckel, H.3
Fischer, A.4
Schultz, W.5
Klinger, H.M.6
-
12
-
-
77549085008
-
Biomechanical advantages of triple-loaded suture anchors compared with double-row rotator cuff repairs
-
F.A. Barber, M.A. Herbert, F.A. Schroeder, J. Ziz-Jacobo, M.M. Mays, J.H. Rapley Biomechanical advantages of triple-loaded suture anchors compared with double-row rotator cuff repairs Arthroscopy 26 2010 316 323
-
(2010)
Arthroscopy
, vol.26
, pp. 316-323
-
-
Barber, F.A.1
Herbert, M.A.2
Schroeder, F.A.3
Ziz-Jacobo, J.4
Mays, M.M.5
Rapley, J.H.6
-
13
-
-
77950896784
-
Outcomes of single-row and double-row arthroscopic rotator cuff repair: A systematic review
-
P. Saridakis, G. Jones Outcomes of single-row and double-row arthroscopic rotator cuff repair: A systematic review J Bone Joint Surg Am 92 2010 732 742
-
(2010)
J Bone Joint Surg Am
, vol.92
, pp. 732-742
-
-
Saridakis, P.1
Jones, G.2
-
14
-
-
34447560059
-
Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: A randomized controlled trial
-
DOI 10.1177/0363546507302218
-
F. Franceschi, L. Ruzzini, U.G. Longo Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: A randomized controlled trial Am J Sports Med 35 2007 1254 1260 (Pubitemid 47084206)
-
(2007)
American Journal of Sports Medicine
, vol.35
, Issue.8
, pp. 1254-1260
-
-
Franceschi, F.1
Ruzzini, L.2
Longo, U.G.3
Martina, F.M.4
Beomonte Zobel, B.5
Maffulli, N.6
Denaro, V.7
-
15
-
-
28344447544
-
Arthroscopic single-row versus double-row suture anchor rotator cuff repair
-
DOI 10.1177/0363546505279575
-
A.D. Mazzocca, P.J. Millett, C.A. Guanche, S.A. Santangelo, R.A. Arciero Arthroscopic single-row versus double-row suture anchor rotator cuff repair Am J Sports Med 33 2005 1861 1868 (Pubitemid 41720586)
-
(2005)
American Journal of Sports Medicine
, vol.33
, Issue.12
, pp. 1861-1868
-
-
Mazzocca, A.D.1
Millett, P.J.2
Guanche, C.A.3
Santangelo, S.A.4
Arciero, R.A.5
-
16
-
-
33750844296
-
A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair
-
DOI 10.2106/JBJS.E.00697
-
C.D. Smith, S. Alexander, A.M. Hill A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair J Bone Joint Surg Am 88 2006 2425 2431 (Pubitemid 44713830)
-
(2006)
Journal of Bone and Joint Surgery - Series A
, vol.88
, Issue.11
, pp. 2425-2431
-
-
Smith, C.D.1
Alexander, S.2
Hill, A.M.3
Huijsmans, P.E.4
Bull, A.M.J.5
Amis, A.A.6
De Beer, J.F.7
Wallace, A.L.8
-
17
-
-
47649097837
-
Cyclic loading of rotator cuff reconstructions: Single-row repair with modified suture configurations versus double-row repair
-
DOI 10.1177/0363546508314424
-
O. Lorbach, F. Bachelier, J. Vees, D. Kohn, D. Pape Cyclic loading of rotator cuff reconstructions: Single-row repair with modified suture configurations versus double-row repair Am J Sports Med 36 2008 1504 1510 (Pubitemid 352019471)
-
(2008)
American Journal of Sports Medicine
, vol.36
, Issue.8
, pp. 1504-1510
-
-
Lorbach, O.1
Bachelier, F.2
Vees, J.3
Kohn, D.4
Pape, D.5
-
18
-
-
0026681706
-
Comparison of initial pull-out strength of arthroscopic suture and staple Bankart repair techniques
-
K.P. Shea, R.M. O'Keefe Jr, J.P. Fulkerson Comparison of initial pull-out strength of arthroscopic suture and staple Bankart repair techniques Arthroscopy 8 1992 179 182
-
(1992)
Arthroscopy
, vol.8
, pp. 179-182
-
-
Shea, K.P.1
O'keefe Jr., R.M.2
Fulkerson, J.P.3
-
19
-
-
0028230452
-
Mechanical strength of repairs of the rotator cuff
-
C. Gerber, A.G. Schneeberger, M. Beck, U. Schlegel Mechanical strength of repairs of the rotator cuff J Bone Joint Surg Br 76 1994 371 380 (Pubitemid 24148334)
-
(1994)
Journal of Bone and Joint Surgery - Series B
, vol.76
, Issue.3
, pp. 371-380
-
-
Gerber, C.1
Schneeberger, A.G.2
Beck, M.3
Schlegel, U.4
-
20
-
-
0032860451
-
Experimental rotator cuff repair. A preliminary study
-
C. Gerber, A.G. Schneeberger, S.M. Perren, R.W. Nyffeler Experimental rotator cuff repair A preliminary study J Bone Joint Surg Am 81 1999 1281 1290 (Pubitemid 29480281)
-
(1999)
Journal of Bone and Joint Surgery - Series A
, vol.81
, Issue.9
, pp. 1281-1290
-
-
Gerber, C.1
Schneeberger, A.G.2
Perren, S.M.3
Nyffeler, R.W.4
-
21
-
-
33750940583
-
Biomechanical comparison of traditional and locked suture configurations for arthroscopic repairs of the rotator cuff
-
DOI 10.1177/0363546506289701
-
A.K. Koganti, G.J. Adamson, C.S. Gregersen, M.M. Pink, J.A. Shankwiler Biomechanical comparison of traditional and locked suture configurations for arthroscopic repairs of the rotator cuff Am J Sports Med 34 2006 1832 1838 (Pubitemid 44735524)
-
(2006)
American Journal of Sports Medicine
, vol.34
, Issue.11
, pp. 1832-1838
-
-
Koganti, A.K.1
Adamson, G.J.2
Gregersen, C.S.3
Pink, M.M.4
Shankwiler, J.A.5
-
22
-
-
0036897573
-
Mechanical strength of arthroscopic rotator cuff repair techniques: An in vitro study
-
A.G. Schneeberger, R.A. von, F. Kalberer, H.A. Jacob, C. Gerber Mechanical strength of arthroscopic rotator cuff repair techniques: An in vitro study J Bone Joint Surg Am 84 2002 2152 2160 (Pubitemid 35417693)
-
(2002)
Journal of Bone and Joint Surgery - Series A
, vol.84
, Issue.12
, pp. 2152-2160
-
-
Schneeberger, A.G.1
Von Roll, A.2
Kalberer, F.3
Jacob, H.A.C.4
Gerber, C.5
-
23
-
-
67650327271
-
A prospective randomized clinical trial comparing arthroscopic single- and double-row rotator cuff repair: Magnetic resonance imaging and early clinical evaluation
-
R.T. Burks, J. Crim, N. Brown, B. Fink, P.E. Greis A prospective randomized clinical trial comparing arthroscopic single- and double-row rotator cuff repair: Magnetic resonance imaging and early clinical evaluation Am J Sports Med 37 2009 674 682
-
(2009)
Am J Sports Med
, vol.37
, pp. 674-682
-
-
Burks, R.T.1
Crim, J.2
Brown, N.3
Fink, B.4
Greis, P.E.5
-
24
-
-
34447529361
-
Can a double-row anchorage technique improve tendon healing in arthroscopic rotator cuff repair? A prospective, nonrandomized, comparative study of double-row and single-row anchorage techniques with computed tomographic arthrography tendon healing assessment
-
DOI 10.1177/0363546507301661
-
C. Charousset, J. Grimberg, L.D. Duranthon, L. Bellaiche, D. Petrover Can a double-row anchorage technique improve tendon healing in arthroscopic rotator cuff repair? A prospective, nonrandomized, comparative study of double-row and single-row anchorage techniques with computed tomographic arthrography tendon healing assessment Am J Sports Med 35 2007 1247 1253 (Pubitemid 47084205)
-
(2007)
American Journal of Sports Medicine
, vol.35
, Issue.8
, pp. 1247-1253
-
-
Charousset, C.1
Grimberg, J.2
Duranthon, L.D.3
Bellaiche, L.4
Petrover, D.5
-
25
-
-
57849087668
-
Single-row versus double-row arthroscopic rotator cuff repair: A prospective randomized clinical study
-
A. Grasso, G. Milano, M. Salvatore, G. Falcone, L. Deriu, C. Fabbriciani Single-row versus double-row arthroscopic rotator cuff repair: A prospective randomized clinical study Arthroscopy 25 2009 4 12
-
(2009)
Arthroscopy
, vol.25
, pp. 4-12
-
-
Grasso, A.1
Milano, G.2
Salvatore, M.3
Falcone, G.4
Deriu, L.5
Fabbriciani, C.6
-
26
-
-
33845920295
-
Biomechanical fixation in arthroscopic rotator cuff repair
-
S.J. Nho, H. Yadav, M. Pensak, C.C. Dodson, C.R. Good, J.D. MacGillivray Biomechanical fixation in arthroscopic rotator cuff repair Arthroscopy 23 2007 94 102
-
(2007)
Arthroscopy
, vol.23
, pp. 94-102
-
-
Nho, S.J.1
Yadav, H.2
Pensak, M.3
Dodson, C.C.4
Good, C.R.5
MacGillivray, J.D.6
-
27
-
-
71849111754
-
Clinical outcomes of double-row versus single-row rotator cuff repairs
-
L.B. Wall, J.D. Keener, R.H. Brophy Clinical outcomes of double-row versus single-row rotator cuff repairs Arthroscopy 25 2009 1312 1318
-
(2009)
Arthroscopy
, vol.25
, pp. 1312-1318
-
-
Wall, L.B.1
Keener, J.D.2
Brophy, R.H.3
-
28
-
-
77953115257
-
Single-row versus double-row arthroscopic rotator cuff repair in small- to medium-sized tears
-
N. Aydin, B. Kocaoglu, O. Guven Single-row versus double-row arthroscopic rotator cuff repair in small- to medium-sized tears J Shoulder Elbow Surg 19 2010 722 725
-
(2010)
J Shoulder Elbow Surg
, vol.19
, pp. 722-725
-
-
Aydin, N.1
Kocaoglu, B.2
Guven, O.3
-
29
-
-
79953178233
-
Prospective randomized clinical trial of single- versus double-row suture anchor repair in 2- to 4-cm rotator cuff tears: Clinical and magnetic resonance imaging results
-
K.H. Koh, K.C. Kang, T.K. Lim, M.S. Shon, J.C. Yoo Prospective randomized clinical trial of single- versus double-row suture anchor repair in 2- to 4-cm rotator cuff tears: Clinical and magnetic resonance imaging results Arthroscopy 27 2011 453 462
-
(2011)
Arthroscopy
, vol.27
, pp. 453-462
-
-
Koh, K.H.1
Kang, K.C.2
Lim, T.K.3
Shon, M.S.4
Yoo, J.C.5
-
31
-
-
34250661991
-
Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
-
DOI 10.1016/j.jse.2006.09.011, PII S105827460600317X
-
M.C. Park, J.E. Tibone, N.S. Elattrache, C.S. Ahmad, B.J. Jun, T.Q. Lee Part II: Biomechanical assessment for a footprint-restoring transosseous- equivalent rotator cuff repair technique compared with a double-row repair technique J Shoulder Elbow Surg 16 2007 469 476 (Pubitemid 47081401)
-
(2007)
Journal of Shoulder and Elbow Surgery
, vol.16
, Issue.4
, pp. 469-476
-
-
Park, M.C.1
Tibone, J.E.2
ElAttrache, N.S.3
Ahmad, C.S.4
Jun, B.-J.5
Lee, T.Q.6
-
32
-
-
0037335039
-
Rotator Cuff repair with bioabsorbable screws: An in vivo and ex vivo investigation
-
DOI 10.1053/jars.2003.50013
-
C.A. Cummins, S. Strickland, R.C. Appleyard, Z.L. Szomor, J. Marshall, G.A. Murrell Rotator cuff repair with bioabsorbable screws: An in vivo and ex vivo investigation Arthroscopy 19 2003 239 248 (Pubitemid 36298135)
-
(2003)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.19
, Issue.3
, pp. 239-248
-
-
Cummins, C.A.1
Strickland, S.2
Appleyard, R.C.3
Szomor, Z.L.4
Marshall, J.5
Murrell, G.A.C.6
-
34
-
-
34250709969
-
Stress distribution in the supraspinatus tendon after tendon repair: Suture anchors versus transosseous suture fixation
-
DOI 10.1177/0363546506296310
-
H. Sano, T. Yamashita, I. Wakabayashi, E. Itoi Stress distribution in the supraspinatus tendon after tendon repair: Suture anchors versus transosseous suture fixation Am J Sports Med 35 2007 542 546 (Pubitemid 46953073)
-
(2007)
American Journal of Sports Medicine
, vol.35
, Issue.4
, pp. 542-546
-
-
Sano, H.1
Yamashita, T.2
Wakabayashi, I.3
Itoi, E.4
-
35
-
-
77951266162
-
Bridging self-reinforcing double-row rotator cuff repair: We really are doing better
-
S.S. Burkhart, B.J. Cole Bridging self-reinforcing double-row rotator cuff repair: We really are doing better Arthroscopy 26 2010 677 680
-
(2010)
Arthroscopy
, vol.26
, pp. 677-680
-
-
Burkhart, S.S.1
Cole, B.J.2
-
36
-
-
77957344318
-
Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations
-
S. Pauly, B. Kieser, A. Schill, C. Gerhardt, M. Scheibel Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations Arthroscopy 26 2010 1281 1288
-
(2010)
Arthroscopy
, vol.26
, pp. 1281-1288
-
-
Pauly, S.1
Kieser, B.2
Schill, A.3
Gerhardt, C.4
Scheibel, M.5
-
37
-
-
26844477493
-
Rotator cuff repair: An ex vivo analysis of suture anchor repair techniques on initial load to failure
-
DOI 10.1016/j.arthro.2005.06.022, PII S0749806305009229
-
C.A. Cummins, R.C. Appleyard, S. Strickland, P.S. Haen, S. Chen, G.A. Murrell Rotator cuff repair: An ex vivo analysis of suture anchor repair techniques on initial load to failure Arthroscopy 21 2005 1236 1241 (Pubitemid 41455108)
-
(2005)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.21
, Issue.10
, pp. 1236-1241
-
-
Cummins, C.A.1
Appleyard, R.C.2
Strickland, S.3
Haen, P.-S.4
Chen, S.5
Murrell, G.A.C.6
-
38
-
-
47649124821
-
Single-row modified Mason-Allen versus double-row arthroscopic rotator cuff repair: A biomechanical and surface area comparison
-
C.O. Nelson, M.J. Sileo, M.G. Grossman, F. Serra-Hsu Single-row modified Mason-Allen versus double-row arthroscopic rotator cuff repair: A biomechanical and surface area comparison Arthroscopy 24 2008 941 948
-
(2008)
Arthroscopy
, vol.24
, pp. 941-948
-
-
Nelson, C.O.1
Sileo, M.J.2
Grossman, M.G.3
Serra-Hsu, F.4
-
39
-
-
36549000239
-
Single-Row Suture Anchor Repair of the Rotator Cuff is Biomechanically Equivalent to Double-Row Repair in a Bovine Model
-
DOI 10.1016/j.arthro.2007.07.010, PII S0749806307006962
-
A. Mahar, J. Tamborlane, R. Oka, J. Esch, R.A. Pedowitz Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model Arthroscopy 23 2007 1265 1270 (Pubitemid 350192137)
-
(2007)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.23
, Issue.12
, pp. 1265-1270
-
-
Mahar, A.1
Tamborlane, J.2
Oka, R.3
Esch, J.4
Pedowitz, R.A.5
-
40
-
-
34249909234
-
Clinical evidence shows no difference between single- and double-row repair for rotator cuff tears
-
DOI 10.1016/j.arthro.2007.01.031, PII S0749806307002435
-
D.J. Reardon, N. Maffulli Clinical evidence shows no difference between single- and double-row repair for rotator cuff tears Arthroscopy 23 2007 670 673 (Pubitemid 46873902)
-
(2007)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.23
, Issue.6
, pp. 670-673
-
-
Reardon, D.J.1
Maffulli, N.2
-
41
-
-
34047242088
-
Arthroscopic rotator cuff repair using a triple-loaded suture anchor and a modified Mason-Allen technique (Alex stitch)
-
A. Castagna, R. Garofalo, M. Conti, M. Borroni, S.J. Snyder Arthroscopic rotator cuff repair using a triple-loaded suture anchor and a modified Mason-Allen technique (Alex stitch) Arthroscopy 23 2007 440 444
-
(2007)
Arthroscopy
, vol.23
, pp. 440-444
-
-
Castagna, A.1
Garofalo, R.2
Conti, M.3
Borroni, M.4
Snyder, S.J.5
-
42
-
-
47349108471
-
Comparison of the clinical outcomes of single- and double-row repairs in rotator cuff tears
-
J.Y. Park, S.H. Lhee, J.H. Choi, H.K. Park, J.W. Yu, J.B. Seo Comparison of the clinical outcomes of single- and double-row repairs in rotator cuff tears Am J Sports Med 36 2008 1310 1316
-
(2008)
Am J Sports Med
, vol.36
, pp. 1310-1316
-
-
Park, J.Y.1
Lhee, S.H.2
Choi, J.H.3
Park, H.K.4
Yu, J.W.5
Seo, J.B.6
-
43
-
-
28344449190
-
Contact area, contact pressure, and pressure patterns of the tendon-bone interface after rotator cuff repair
-
DOI 10.1177/0363546505278256
-
Y. Tuoheti, E. Itoi, N. Yamamoto Contact area, contact pressure, and pressure patterns of the tendon-bone interface after rotator cuff repair Am J Sports Med 33 2005 1869 1874 (Pubitemid 41720587)
-
(2005)
American Journal of Sports Medicine
, vol.33
, Issue.12
, pp. 1869-1874
-
-
Tuoheti, Y.1
Itoi, E.2
Yamamoto, N.3
Seki, N.4
Abe, H.5
Minagawa, H.6
Okada, K.7
Shimada, Y.8
-
44
-
-
77149133407
-
In vitro biomechanical comparison of three different types of single- and double-row arthroscopic rotator cuff repairs: Analysis of continuous bone-tendon contact pressure and surface during different simulated joint positions
-
J. Grimberg, A. Diop, K. Kalra, C. Charousset, L.D. Duranthon, N. Maurel In vitro biomechanical comparison of three different types of single- and double-row arthroscopic rotator cuff repairs: Analysis of continuous bone-tendon contact pressure and surface during different simulated joint positions J Shoulder Elbow Surg 19 2010 236 243
-
(2010)
J Shoulder Elbow Surg
, vol.19
, pp. 236-243
-
-
Grimberg, J.1
Diop, A.2
Kalra, K.3
Charousset, C.4
Duranthon, L.D.5
Maurel, N.6
-
46
-
-
77953941325
-
Biomechanical advantages of triple-loaded suture anchors compared with double-row rotator cuff repairsAuthor's reply
-
F. Barber, J. Aziz-Jacobo, J.H. Rapley, M.A. Herbert, F.A. Schroeder, M.M. Mays Biomechanical advantages of triple-loaded suture anchors compared with double-row rotator cuff repairsAuthor's reply Arthroscopy 26 2010 874 876
-
(2010)
Arthroscopy
, vol.26
, pp. 874-876
-
-
Barber, F.1
Aziz-Jacobo, J.2
Rapley, J.H.3
Herbert, M.A.4
Schroeder, F.A.5
Mays, M.M.6
-
47
-
-
77952721204
-
Arthroscopic supraspinatus tendon repair with suture-bridging technique: Functional outcome and magnetic resonance imaging
-
C. Voigt, C. Bosse, R. Vosshenrich, A.P. Schulz, H. Lill Arthroscopic supraspinatus tendon repair with suture-bridging technique: Functional outcome and magnetic resonance imaging Am J Sports Med 38 2010 983 991
-
(2010)
Am J Sports Med
, vol.38
, pp. 983-991
-
-
Voigt, C.1
Bosse, C.2
Vosshenrich, R.3
Schulz, A.P.4
Lill, H.5
-
48
-
-
38149140193
-
Comparison between single-row and double-row rotator cuff repair: A biomechanical study
-
G. Milano, A. Grasso, D. Zarelli, L. Deriu, M. Cillo, C. Fabbriciani Comparison between single-row and double-row rotator cuff repair: A biomechanical study Knee Surg Sports Traumatol Arthrosc 16 2008 75 80
-
(2008)
Knee Surg Sports Traumatol Arthrosc
, vol.16
, pp. 75-80
-
-
Milano, G.1
Grasso, A.2
Zarelli, D.3
Deriu, L.4
Cillo, M.5
Fabbriciani, C.6
|