메뉴 건너뛰기




Volumn 24, Issue 5, 2011, Pages 804-813

Occlusal caries depth measurements obtained by five different imaging modalities

Author keywords

CBCT; Depth measurement; Micro CT; Occlusal caries; Radiography

Indexed keywords

CBCT; CBCT IMAGES; CCD IMAGES; CONE BEAM; DEPTH MEASUREMENTS; EX-VIVO; FILM IMAGES; HIGH RESOLUTION; HISTOLOGICAL IMAGES; IMAGE SETS; IMAGING METHOD; IMAGING MODALITY; INTRACLASS CORRELATION COEFFICIENTS; LESION DEPTH; MEASUREMENT TOOLS; MICRO CT; MICROCOMPUTER TOMOGRAPHY; MOLAR TEETH; OCCLUSAL CARIES; REPRODUCIBILITIES; SOFTWARE PROGRAM;

EID: 84855570383     PISSN: 08971889     EISSN: 1618727X     Source Type: Journal    
DOI: 10.1007/s10278-010-9355-9     Document Type: Article
Times cited : (30)

References (31)
  • 2
    • 33646514400 scopus 로고    scopus 로고
    • Three-dimensional study of human dental fissure enamel by synchrotron X-ray microtomography
    • DOI 10.1111/j.1600-0722.2006.00315.x
    • Dowker SEP, Elliott JC, Davis GR, Wilson RM, Cloetens P: Threedimensional study of human dental fissure enamel by synchrotron X-ray microtomography. Eur J Oral Sci 114(Suppl. 1):353-359, 2006 (Pubitemid 43709462)
    • (2006) European Journal of Oral Sciences , vol.114 , Issue.SUPPL. 1 , pp. 353-359
    • Dowker, S.E.P.1    Elliott, J.C.2    Davis, G.R.3    Wilson, R.M.4    Cloetens, P.5
  • 3
    • 0034152651 scopus 로고    scopus 로고
    • Occlusal caries detection with KaVo DIAGNOdent and radiography: An in vitro comparison
    • Shi XQ, Welander U, Angmar-Mansson B: Occlusal caries detection with KaVo DIAGNOdent and radiography: an in vitro comparison. Caries Res 34:151-158, 2000
    • (2000) Caries Res , vol.34 , pp. 151-158
    • Shi, X.Q.1    Welander, U.2    Angmar-Mansson, B.3
  • 4
    • 33845759387 scopus 로고    scopus 로고
    • Effects of dental probing on occlusal surfaces - A scanning electron microscopy evaluation
    • Kühnisch J, Dietz W, Stösser L, Hickel R, Heinrich-Weltzien R: Effects of dental probing on occlusal surfaces-a scanning electron microscopy evaluation. Caries Res 41:43-48, 2007
    • (2007) Caries Res , vol.41 , pp. 43-48
    • Kühnisch, J.1    Dietz, W.2    Stösser, L.3    Hickel, R.4    Heinrich-Weltzien, R.5
  • 5
    • 33646811872 scopus 로고    scopus 로고
    • Validity and reproducibility of different combinations of methods for occlusal caries detection: An in vitro comparison
    • DOI 10.1159/000092225
    • Souza-Zaroni WC, Ciccone JC, Souza-Gabriel AE, Ramos RP, Corona SAM, Palma-Dibb RG: Validity and reproducibility of different combinations of methods for occlusal caries detection: an in vitro comparison. Caries Res 40:194-201, 2006 (Pubitemid 43760293)
    • (2006) Caries Research , vol.40 , Issue.3 , pp. 194-201
    • Souza-Zaroni, W.C.1    Ciccone, J.C.2    Souza-Gabriel, A.E.3    Ramos, R.P.4    Corona, S.A.M.5    Palma-Dibb, R.G.6
  • 6
    • 33745466084 scopus 로고    scopus 로고
    • DIAGNOdent measurements and correlation with the depth and volume of minimally invasive cavity preparations
    • Hamilton JC, Gregory WA, Valentine JB: DIAGNOdent measurements and correlation with the depth and volume of minimally invasive cavity preparations. Oper Dent 31:291-296, 2006 (Pubitemid 43954677)
    • (2006) Operative Dentistry , vol.31 , Issue.3 , pp. 291-296
    • Hamilton, J.C.1    Gregory, W.A.2    Valentine, J.B.3
  • 8
    • 47949107683 scopus 로고    scopus 로고
    • Performance of fluorescence methods, radiographic examination and ICDAS II on occlusal surfaces in vitro
    • Rodrigues JA, Hug I, Diniz MB, Lussi A: Performance of fluorescence methods, radiographic examination and ICDAS II on occlusal surfaces in vitro. Caries Res 42:297-304, 2008
    • (2008) Caries Res , vol.42 , pp. 297-304
    • Rodrigues, J.A.1    Hug, I.2    Diniz, M.B.3    Lussi, A.4
  • 9
    • 62849104083 scopus 로고    scopus 로고
    • Performance of laser fluorescence for detection of occlusal dentinal caries lesions in permanent molars: An in vivo study with total validation of the sample
    • Abalos C, Herrera M, Jimenez-Planas A, Llamas R: Performance of laser fluorescence for detection of occlusal dentinal caries lesions in permanent molars: an in vivo study with total validation of the sample. Caries Res 43:137-141, 2009
    • (2009) Caries Res , vol.43 , pp. 137-141
    • Abalos, C.1    Herrera, M.2    Jimenez-Planas, A.3    Llamas, R.4
  • 10
    • 0030154245 scopus 로고    scopus 로고
    • Clinical and laboratory radiographic caries diagnosis. A study of the same teeth
    • Hintze H, Wenzel A: Clinical and laboratory radiographic caries diagnosis. A study same teeth. Dentomaxillofac Radiol 25:115-118, 1996 (Pubitemid 126422006)
    • (1996) Dentomaxillofacial Radiology , vol.25 , Issue.3 , pp. 115-118
    • Hintze, H.1    Wenzel, A.2
  • 12
    • 33846885211 scopus 로고    scopus 로고
    • Accuracy and reproducibility of conventional radiographic assessment and subtraction radiography in detecting demineralization in occlusal surfaces
    • Ricketts DNJ, Ekstrand KR, Martignon S, Ellwood R, Alatsaris M, Nugent Z: Accuracy and reproducibility of conventional radiographic assessment and subtraction radiography in detecting demineralization in occlusal surfaces. Caries Res 41:121-128, 2007
    • (2007) Caries Res , vol.41 , pp. 121-128
    • Ricketts, D.N.J.1    Ekstrand, K.R.2    Martignon, S.3    Ellwood, R.4    Alatsaris, M.5    Nugent, Z.6
  • 13
    • 58449085501 scopus 로고    scopus 로고
    • Validity of caries detection on occlusal surfaces and treatment decisions based on results from multiple caries-detection methods
    • Pereira AC, Eggertsson H, Martinez-Mier EA, Mialhe FL, Eckert GJ, Zero DT: Validity of caries detection on occlusal surfaces and treatment decisions based on results from multiple caries-detection methods. Eur J Oral Sci 117:51-57, 2009
    • (2009) Eur J Oral Sci , vol.117 , pp. 51-57
    • Pereira, A.C.1    Eggertsson, H.2    Martinez-Mier, E.A.3    Mialhe, F.L.4    Eckert, G.J.5    Zero, D.T.6
  • 14
    • 70349410451 scopus 로고    scopus 로고
    • Comparison of visual inspection and different radiographic methods for dentin caries detection on occlusal surfaces
    • Kühnisch J, Ifland S, Tranaeus S, Heinrich-Weltzien R: Comparison of visual inspection and different radiographic methods for dentin caries detection on occlusal surfaces. Dentomaxillofac Radiol 38:452-457, 2009
    • (2009) Dentomaxillofac Radiol , vol.38 , pp. 452-457
    • Kühnisch, J.1    Ifland, S.2    Tranaeus, S.3    Heinrich-Weltzien, R.4
  • 15
    • 75149166088 scopus 로고    scopus 로고
    • A comparison of the diagnostic accuracy of in vivo and in vitro photostimulable phosphor digital images in the detection of occlusal caries lesions
    • Kamburoǧlu K, Şenel B, Yüksel SP, Özen T: A comparison of the diagnostic accuracy of in vivo and in vitro photostimulable phosphor digital images in the detection of occlusal caries lesions. Dentomaxillofac Radiol 39:17-22, 2010
    • (2010) Dentomaxillofac Radiol , vol.39 , pp. 17-22
    • Kamburoǧlu, K.1    Şenel, B.2    Yüksel, S.P.3    Özen, T.4
  • 16
    • 52049117425 scopus 로고    scopus 로고
    • What is cone-beam CT and how does it work?
    • Scarfe WC, Farman AG: What is cone-beam CT and how does it work? Dent Clin North Am 52:707-730, 2008
    • (2008) Dent Clin North Am , vol.52 , pp. 707-730
    • Scarfe, W.C.1    Farman, A.G.2
  • 17
    • 52049112120 scopus 로고    scopus 로고
    • Cone-beam CT diagnostic applications: Caries, periodontal bone assessment, and endodontic applications
    • Tyndall DA, Rathore S: Cone-beam CT diagnostic applications: caries, periodontal bone assessment, and endodontic applications. Dent Clin North Am 52:825-841, 2008
    • (2008) Dent Clin North Am , vol.52 , pp. 825-841
    • Tyndall, D.A.1    Rathore, S.2
  • 18
    • 33646768211 scopus 로고    scopus 로고
    • Accuracy of proximal caries depth measurements: Comparison between limited cone beam computed tomography, storage phosphor and film radiography
    • DOI 10.1159/000092226
    • Akdeniz BG, Gröndahl HG, Magnusson B: Accuracy of proximal caries depth measurements: comparison between limited cone beam computed tomography, storage phosphor and film radiography. Caries Res 40:202-207, 2006 (Pubitemid 43760294)
    • (2006) Caries Research , vol.40 , Issue.3 , pp. 202-207
    • Akdeniz, B.G.1    Grondahl, H.-G.2    Magnusson, B.3
  • 20
    • 38949161444 scopus 로고    scopus 로고
    • Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions
    • DOI 10.1259/dmfr/87103878
    • Haiter-Neto F, Wenzel A, Gotfredsen E: Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dentomaxillofac Radiol 37:18-22, 2008 (Pubitemid 351211972)
    • (2008) Dentomaxillofacial Radiology , vol.37 , Issue.1 , pp. 18-22
    • Haiter-Neto, F.1    Wenzel, A.2    Gotfredsen, E.3
  • 21
    • 70349273746 scopus 로고    scopus 로고
    • A comparative study of high-resolution cone beam computed tomography and charge-coupled device sensors for detecting caries
    • Young SM, Lee JT, Hodges RJ, Chang TL, Elashoff DA, White SC: A comparative study of high-resolution cone beam computed tomography and charge-coupled device sensors for detecting caries. Dentomaxillofac Radiol 38:445-451, 2009
    • (2009) Dentomaxillofac Radiol , vol.38 , pp. 445-451
    • Young, S.M.1    Lee, J.T.2    Hodges, R.J.3    Chang, T.L.4    Elashoff, D.A.5    White, S.C.6
  • 22
    • 58249137979 scopus 로고    scopus 로고
    • Occlusal caries: Evaluation of direct microscopy versus digital imaging used for two histological classification systems
    • Jablonski-Momeni A, Ricketts DNJ, Stachniss V, Maschka R, Heinzel-Gutenbrunner M, Pieper K: Occlusal caries: evaluation of direct microscopy versus digital imaging used for two histological classification systems. J Dent 37:204-211, 2009
    • (2009) J Dent , vol.37 , pp. 204-211
    • Jablonski-Momeni, A.1    Ricketts, D.N.J.2    Stachniss, V.3    Maschka, R.4    Heinzel-Gutenbrunner, M.5    Pieper, K.6
  • 23
    • 67649211704 scopus 로고    scopus 로고
    • A system of calibrating microtomography for use in caries research
    • Schwass DR, Swain MV, Purton DG, Leichter JW: A system of calibrating microtomography for use in caries research. Caries Res 43:314-321, 2009
    • (2009) Caries Res , vol.43 , pp. 314-321
    • Schwass, D.R.1    Swain, M.V.2    Purton, D.G.3    Leichter, J.W.4
  • 24
    • 54849437306 scopus 로고    scopus 로고
    • Quantitative measurements obtained by micro-computed tomography and confocal laser scanning microscopy
    • Kamburoǧlu K, Barenboim SF, Aritürk T, Kaffe I: Quantitative measurements obtained by micro-computed tomography and confocal laser scanning microscopy. Dentomaxillofac Radiol 37:385-391, 2008
    • (2008) Dentomaxillofac Radiol , vol.37 , pp. 385-391
    • Kamburoǧlu, K.1    Barenboim, S.F.2    Aritürk, T.3    Kaffe, I.4
  • 26
    • 65549109931 scopus 로고    scopus 로고
    • Evaluation of laser fluorescence in the monitoring of the initial stage of the de-/remineralization process: An in vitro and in situ study
    • Spiguel MH, Tovo MF, Kramer PF, Franco KS, Alves KMPR, Delbem ACB: Evaluation of laser fluorescence in the monitoring of the initial stage of the de-/remineralization process: an in vitro and in situ study. Caries Res 43:302-307, 2009
    • (2009) Caries Res , vol.43 , pp. 302-307
    • Spiguel, M.H.1    Tovo, M.F.2    Kramer, P.F.3    Franco, K.S.4    Alves, K.M.P.R.5    Delbem, A.C.B.6
  • 27
    • 33644636336 scopus 로고    scopus 로고
    • An in vitro comparison between two methods of electrical resistance measurement for occlusal caries detection
    • DOI 10.1159/000091055
    • Kühnisch J, Heinrich-Weltzien R, Tabatabaie M, Stösser L, Huysmans MCDNJM: An in vitro comparison between two methods of electrical resistance measurement for occlusal caries detection. Caries Res 40:104-111, 2006 (Pubitemid 43325869)
    • (2006) Caries Research , vol.40 , Issue.2 , pp. 104-111
    • Kuhnisch, J.1    Heinrich-Weltzien, R.2    Tabatabaie, M.3    Stosser, L.4    Huysmans, M.C.D.N.J.M.5
  • 28
    • 0027722540 scopus 로고
    • Performance of electrical resistance measurements adjunct visual inspection in the early diagnosis of occlusal caries
    • Verdonschot EH, Wenzel A, Truin GJ, König KG: Performance of electrical resistance measurements adjunct visual inspection in the early diagnosis of occlusal caries. J Dent 21:332-337, 1993
    • (1993) J Dent , vol.21 , pp. 332-337
    • Verdonschot, E.H.1    Wenzel, A.2    Truin, G.J.3    König, K.G.4
  • 31
    • 45949102819 scopus 로고    scopus 로고
    • Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology
    • Ludlow JB, Ivanovic M: Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106:106-114, 2008
    • (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.106 , pp. 106-114
    • Ludlow, J.B.1    Ivanovic, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.