메뉴 건너뛰기




Volumn 38, Issue 7, 2009, Pages 445-451

A comparative study of high-resolution cone beam computed tomography and charge-coupled device sensors for detecting caries

Author keywords

Cone beam computed tomography; Dental caries; Radiography, dental; Radiography, dental, digital

Indexed keywords

ARTICLE; COMPARATIVE STUDY; CONE BEAM COMPUTED TOMOGRAPHY; CONTROLLED STUDY; DENTAL CARIES; DENTIN; DENTIST; ENAMEL; HIGH RESOLUTION COMPUTER TOMOGRAPHY; HUMAN; IMAGE ANALYSIS; MAJOR CLINICAL STUDY; MICRO-COMPUTED TOMOGRAPHY; MOLAR TOOTH; PREMOLAR TOOTH; SENSITIVITY AND SPECIFICITY; SENSOR;

EID: 70349273746     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1259/dmfr/88765582     Document Type: Article
Times cited : (53)

References (28)
  • 1
    • 0029193836 scopus 로고
    • Clinical and radiographic diagnosis of occlusal caries: A study in vitro
    • Ricketts DN, Kidd EA, Smith BG, Wilson RF. Clinical and radiographic diagnosis of occlusal caries: a study in vitro. J Oral Rehabil 1995; 22: 15-20.
    • (1995) J Oral Rehabil , vol.22 , pp. 15-20
    • Ricketts, D.N.1    Kidd, E.A.2    Smith, B.G.3    Wilson, R.F.4
  • 4
    • 0022802095 scopus 로고
    • Radiographic diagnoses and treatment decisions on approximal caries
    • Espelid I. Radiographic diagnoses and treatment decisions on approximal caries. Community Dent Oral Epidemiol 1986; 14: 265-270.
    • (1986) Community Dent Oral Epidemiol , vol.14 , pp. 265-270
    • Espelid, I.1
  • 5
    • 4143081769 scopus 로고    scopus 로고
    • Bitewing and digital bitewing radiography for detection of caries lesions
    • DOI 10.1177/154405910408301S14
    • Wenzel A. Bitewing and digital bitewing radiography for detection of caries lesions. J Dent Res 2004; 83: C72-75. (Pubitemid 44131379)
    • (2004) Journal of Dental Research , vol.83 , Issue.SPEC. ISS. C
    • Wenzel, A.1
  • 6
    • 0033173466 scopus 로고    scopus 로고
    • Detection of caries with conventional digital imaging and tuned aperture computed tomography using CRT monitor and laptop displays
    • Abreu M, Jr, Tyndall DA, Ludlow JB. Detection of caries with conventional digital imaging and tuned aperture computed tomography using CRT monitor and laptop displays. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1999; 88: 234-238.
    • (1999) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.88 , pp. 234-238
    • Abreu Jr., M.1    Tyndall, D.A.2    Ludlow, J.B.3
  • 7
    • 0034278290 scopus 로고    scopus 로고
    • Radiographic detection of approximal caries: A comparison of dental films and digital imaging systems
    • Syriopoulos K, Sanderink GC, Velders XL, van der Stelt PF. Radiographic detection of approximal caries: a comparison of dental films and digital imaging systems. Dentomaxillofac Radiol 2000; 29: 312-318.
    • (2000) Dentomaxillofac Radiol , vol.29 , pp. 312-318
    • Syriopoulos, K.1    Sanderink, G.C.2    Velders, X.L.3    Van Der Stelt, P.F.4
  • 8
    • 0036559422 scopus 로고    scopus 로고
    • Accuracy of caries detection with four storage phosphor systems and E-speed radiographs
    • DOI 10.1038/sj.dmfr.4600686
    • Hintze H, Wenzel A, Frydenberg M. Accuracy of caries detection with four storage phosphor systems and E-speed radiographs. Dentomaxillofac Radiol 2002; 31: 170-175. (Pubitemid 38998474)
    • (2002) Dentomaxillofacial Radiology , vol.31 , Issue.3 , pp. 170-175
    • Hintze, H.1    Wenzel, A.2    Frydenberg, M.3
  • 9
    • 14744281188 scopus 로고    scopus 로고
    • Proximal caries detection: Sirona Sidexis versus Kodak Ektaspeed Plus
    • Khan EA, Tyndall DA, Ludlow JB, Caplan D. Proximal caries detection: Sirona Sidexis versus Kodak Ektaspeed Plus. Gen Dent 2005; 53: 43-48. (Pubitemid 40326767)
    • (2005) General Dentistry , vol.53 , Issue.1 , pp. 43-48
    • Khan, E.A.1    Tyndall, D.A.2    Ludlow, J.B.3    Caplan, D.4
  • 10
    • 34347268849 scopus 로고    scopus 로고
    • In vitro comparison of conventional film and direct digital imaging in the detection of approximal caries
    • Castro VM, Katz JO, Hardman PK, Glaros AG, Spencer P. In vitro comparison of conventional film and direct digital imaging in the detection of approximal caries. Dentomaxillofac Radiol 2007; 36: 138-142.
    • (2007) Dentomaxillofac Radiol , vol.36 , pp. 138-142
    • Castro, V.M.1    Katz, J.O.2    Hardman, P.K.3    Glaros, A.G.4    Spencer, P.5
  • 11
    • 0026294721 scopus 로고
    • Detection of occlusal caries without cavitation by visual inspection, film radiographs, xeroradiographs, and digitized radiographs
    • Wenzel A, Larsen MJ, Fejerskov O. Detection of occlusal caries without cavitation by visual inspection, film radiographs, xeroradiographs, and digitized radiographs. Caries Res 1991; 25: 365-371.
    • (1991) Caries Res , vol.25 , pp. 365-371
    • Wenzel, A.1    Larsen, M.J.2    Fejerskov, O.3
  • 14
    • 0030621857 scopus 로고    scopus 로고
    • Tunedaperture computed tomography (TACT). Theory and application for three-dimensional dento-alveolar imaging
    • Webber RL, Horton RA, Tyndall DA, Ludlow JB. Tunedaperture computed tomography (TACT). Theory and application for three-dimensional dento-alveolar imaging. Dentomaxillofac Radiol 1997; 26: 53-62.
    • (1997) Dentomaxillofac Radiol , vol.26 , pp. 53-62
    • Webber, R.L.1    Horton, R.A.2    Tyndall, D.A.3    Ludlow, J.B.4
  • 15
    • 14044258579 scopus 로고    scopus 로고
    • Effect of number of projections on image quality of local CT
    • DOI 10.1259/dmfr/23496562
    • van Daatselaar AN, van der Stelt PF, Weenen J. Effect of number of projections on image quality of local CT. Dentomaxillofac Radiol 2004; 33: 361-369. (Pubitemid 40278843)
    • (2004) Dentomaxillofacial Radiology , vol.33 , Issue.6 , pp. 361-369
    • Van Daatselaar, A.N.1    Van Der Stelt, P.F.2    Weenen, J.3
  • 17
    • 33646847310 scopus 로고    scopus 로고
    • Accuracy of extraoral tuned aperture computed tomography (TACT) for proximal caries detection
    • Harase Y, Araki K, Okano T. Accuracy of extraoral tuned aperture computed tomography (TACT) for proximal caries detection. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2006; 101: 791-796.
    • (2006) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.101 , pp. 791-796
    • Harase, Y.1    Araki, K.2    Okano, T.3
  • 19
    • 0033122376 scopus 로고    scopus 로고
    • Two- And three-dimensional imaging modalities for the detection of caries. a comparison between film, digital radiography and tuned aperture computed tomography (TACT)
    • Abreu M, Tyndall DA, Platin E, Ludlow JB, Phillips C. Two- and three-dimensional imaging modalities for the detection of caries. A comparison between film, digital radiography and tuned aperture computed tomography (TACT). Dentomaxillofac Radiol 1999; 28: 152-157.
    • (1999) Dentomaxillofac Radiol , vol.28 , pp. 152-157
    • Abreu, M.1    Tyndall, D.A.2    Platin, E.3    Ludlow, J.B.4    Phillips, C.5
  • 22
    • 33646768211 scopus 로고    scopus 로고
    • Accuracy of proximal caries depth measurements: Comparison between limited cone beam computed tomography, storage phosphor and film radiography
    • Akdeniz BG, Grondahl HG, Magnusson B. Accuracy of proximal caries depth measurements: comparison between limited cone beam computed tomography, storage phosphor and film radiography. Caries Res 2006; 40: 202-207.
    • (2006) Caries Res , vol.40 , pp. 202-207
    • Akdeniz, B.G.1    Grondahl, H.G.2    Magnusson, B.3
  • 23
    • 34547873534 scopus 로고    scopus 로고
    • Evaluation of a limited conebeam volumetric imaging system: Comparison with film radiography in detecting incipient proximal caries
    • Tsuchida R, Araki K, Okano T. Evaluation of a limited conebeam volumetric imaging system: comparison with film radiography in detecting incipient proximal caries. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 104: 412-416.
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.104 , pp. 412-416
    • Tsuchida, R.1    Araki, K.2    Okano, T.3
  • 24
    • 38949161444 scopus 로고    scopus 로고
    • Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions
    • DOI 10.1259/dmfr/87103878
    • Haiter-Neto F, Wenzel A, Gotfredsen E. Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dentomaxillofac Radiol 2008; 37: 18-22. (Pubitemid 351211972)
    • (2008) Dentomaxillofacial Radiology , vol.37 , Issue.1 , pp. 18-22
    • Haiter-Neto, F.1    Wenzel, A.2    Gotfredsen, E.3
  • 25
    • 33745240037 scopus 로고    scopus 로고
    • Mineral concentration of natural human teeth by a commercial micro-CT
    • Clementino-Luedemann TN, Kunzelmann KH. Mineral concentration of natural human teeth by a commercial micro-CT. Dent Mater J 2006; 25: 113-119.
    • (2006) Dent Mater J , vol.25 , pp. 113-119
    • Clementino-Luedemann, T.N.1    Kunzelmann, K.H.2
  • 26
    • 0034157416 scopus 로고    scopus 로고
    • Application of high resolution microfocus X-ray CT for the observation of human tooth
    • Hayakawa T, Mishima H, Yokota I, Sakae T, Kozawa Y, Nemoto K. Application of high resolution microfocus X-ray CT for the observation of human tooth. Dent Mater J 2000; 19: 87-95.
    • (2000) Dent Mater J , vol.19 , pp. 87-95
    • Hayakawa, T.1    Mishima, H.2    Yokota, I.3    Sakae, T.4    Kozawa, Y.5    Nemoto, K.6
  • 27
    • 48649089199 scopus 로고    scopus 로고
    • Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view
    • Hirsch E, Wolf U, Heinicke F, Silva MA. Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view. Dentomaxillofac Radiol 2008; 37: 268-273.
    • (2008) Dentomaxillofac Radiol , vol.37 , pp. 268-273
    • Hirsch, E.1    Wolf, U.2    Heinicke, F.3    Ma, S.4
  • 28
    • 52749087498 scopus 로고    scopus 로고
    • Patient risk from common dental radiographic examinations
    • Ludlow JB, Davies-Ludlow LE, White SC. Patient risk from common dental radiographic examinations. J Am Dent Assoc 2008; 139: 1237-1243.
    • (2008) J Am Dent Assoc , vol.139 , pp. 1237-1243
    • Ludlow, J.B.1    Davies-Ludlow, L.E.2    White, S.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.