메뉴 건너뛰기




Volumn 27, Issue 2, 2012, Pages 213-219

Ceramic-on-ceramic total hip arthroplasty in patients younger than 20 years

Author keywords

Ceramic; Total hip arthroplasty

Indexed keywords

ADULT; ARTICLE; CERAMICS; CHILD; CLINICAL ARTICLE; FEMALE; FOLLOW UP; HARRIS HIP SCORE; HIP DISLOCATION; HUMAN; MALE; PERONEUS NERVE PARALYSIS; POSTOPERATIVE COMPLICATION; PROSTHESIS LOOSENING; SCHOOL CHILD; SURVIVAL RATE; TOTAL HIP PROSTHESIS;

EID: 84855533712     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2011.05.022     Document Type: Article
Times cited : (60)

References (30)
  • 1
    • 0019844264 scopus 로고
    • Total hip replacement in patients younger than thirty years old. A five-year follow-up study
    • Chandler H.P., Reineck F.T., Wixson R.L., et al. Total hip replacement in patients younger than thirty years old. A five-year follow-up study. J Bone Joint Surg 1981, 63:1426.
    • (1981) J Bone Joint Surg , vol.63 , pp. 1426
    • Chandler, H.P.1    Reineck, F.T.2    Wixson, R.L.3
  • 2
    • 0036882426 scopus 로고    scopus 로고
    • Total hip arthroplasty in patients younger than 30 years of age following developmental dysplasia of hip (DDH) in infancy
    • Dudkiewicz I., Salai M., Ganel A., et al. Total hip arthroplasty in patients younger than 30 years of age following developmental dysplasia of hip (DDH) in infancy. Arch Orthop Trauma Surg 2002, 122:139.
    • (2002) Arch Orthop Trauma Surg , vol.122 , pp. 139
    • Dudkiewicz, I.1    Salai, M.2    Ganel, A.3
  • 3
    • 67249094168 scopus 로고    scopus 로고
    • Single-stage bilateral total hip arthroplasty in patients less than 35 years. Forty arthroplasties with 5-17 years follow-up
    • Simon J.P., Robbens E., Maes M., et al. Single-stage bilateral total hip arthroplasty in patients less than 35 years. Forty arthroplasties with 5-17 years follow-up. Acta Orthop Belg 2009, 75:189.
    • (2009) Acta Orthop Belg , vol.75 , pp. 189
    • Simon, J.P.1    Robbens, E.2    Maes, M.3
  • 4
    • 21244454913 scopus 로고    scopus 로고
    • Cementless hip arthroplasty in juvenile idiopathic arthritis
    • Odent T., Journeau P., Prieur A.M., et al. Cementless hip arthroplasty in juvenile idiopathic arthritis. J Pediatr Orthop 2005, 25:465.
    • (2005) J Pediatr Orthop , vol.25 , pp. 465
    • Odent, T.1    Journeau, P.2    Prieur, A.M.3
  • 5
    • 56149097353 scopus 로고    scopus 로고
    • Uncemented total hip arthroplasty in patients less than twenty-years
    • Restrepo C., Lettich T., Roberts N., et al. Uncemented total hip arthroplasty in patients less than twenty-years. Acta Orthop Belg 2008, 74:615.
    • (2008) Acta Orthop Belg , vol.74 , pp. 615
    • Restrepo, C.1    Lettich, T.2    Roberts, N.3
  • 6
    • 41949109906 scopus 로고    scopus 로고
    • Alumina-on-alumina hip arthroplasty in patients younger than 30 years old
    • Nizard R., Pourreyron D., Raould A., et al. Alumina-on-alumina hip arthroplasty in patients younger than 30 years old. Clin Orthop Relat Res 2008, 466:317.
    • (2008) Clin Orthop Relat Res , vol.466 , pp. 317
    • Nizard, R.1    Pourreyron, D.2    Raould, A.3
  • 7
    • 0030054822 scopus 로고    scopus 로고
    • Total hip arthroplasty with cement in patients less than twenty years old. Long-term results
    • Torchia M.E., Klassen R.A., Bianco A.J. Total hip arthroplasty with cement in patients less than twenty years old. Long-term results. J Bone Joint Surg 1996, 78A:995.
    • (1996) J Bone Joint Surg , vol.78 A , pp. 995
    • Torchia, M.E.1    Klassen, R.A.2    Bianco, A.J.3
  • 8
    • 0025856480 scopus 로고
    • Total hip replacement for juvenile chronic arthritis
    • Witt J.D., Swann M., Ansell B.M. Total hip replacement for juvenile chronic arthritis. J Bone Joint Surg 1991, 73B:770.
    • (1991) J Bone Joint Surg , vol.73 B , pp. 770
    • Witt, J.D.1    Swann, M.2    Ansell, B.M.3
  • 9
    • 0031906295 scopus 로고    scopus 로고
    • Long-term results of cemented Charnley low-friction arthroplasty in patients aged less than 30 years
    • Sochart D.H., Porter M.L. Long-term results of cemented Charnley low-friction arthroplasty in patients aged less than 30 years. J Arthroplasty 1998, 13:123.
    • (1998) J Arthroplasty , vol.13 , pp. 123
    • Sochart, D.H.1    Porter, M.L.2
  • 10
    • 0041967428 scopus 로고    scopus 로고
    • Total hip arthroplasty in patients younger than 21 years: a minimum, 10-year follow-up
    • Bessette B.J., Fassier F., Tanzer M., et al. Total hip arthroplasty in patients younger than 21 years: a minimum, 10-year follow-up. Can J Surg 2003, 46:257.
    • (2003) Can J Surg , vol.46 , pp. 257
    • Bessette, B.J.1    Fassier, F.2    Tanzer, M.3
  • 11
    • 73349126717 scopus 로고    scopus 로고
    • Charnley low-friction arthroplasty in young patients with osteoarthritis: outcomes at a minimum of twenty-two years
    • Georgiades G., Babis G.C., Hartofilakidis G. Charnley low-friction arthroplasty in young patients with osteoarthritis: outcomes at a minimum of twenty-two years. J Bone Joint Surg 2009, 91A:2846.
    • (2009) J Bone Joint Surg , vol.91 A , pp. 2846
    • Georgiades, G.1    Babis, G.C.2    Hartofilakidis, G.3
  • 12
    • 69249202605 scopus 로고    scopus 로고
    • Alumina-on-alumina total hip arthroplasty in young patients: diagnosis is more important than age
    • Garcia-Rey E., Cruz-Pardos A., Garcia-Cimbrelo E. Alumina-on-alumina total hip arthroplasty in young patients: diagnosis is more important than age. Clin Orthop Relat Res 2009, 467:2281.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 2281
    • Garcia-Rey, E.1    Cruz-Pardos, A.2    Garcia-Cimbrelo, E.3
  • 13
    • 0031864657 scopus 로고    scopus 로고
    • Uncemented total hip arthroplasty in young patients with juvenile chronic arthritis
    • Kumar M.N., Swann M. Uncemented total hip arthroplasty in young patients with juvenile chronic arthritis. Ann R Coll Surg Engl 1998, 80:203.
    • (1998) Ann R Coll Surg Engl , vol.80 , pp. 203
    • Kumar, M.N.1    Swann, M.2
  • 14
    • 41049109528 scopus 로고    scopus 로고
    • Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem
    • Wangen H., Lereim P., Holm I., et al. Hip arthroplasty in patients younger than 30 years: excellent ten to 16-year follow-up results with a HA-coated stem. Int Orthop 2008, 32:203.
    • (2008) Int Orthop , vol.32 , pp. 203
    • Wangen, H.1    Lereim, P.2    Holm, I.3
  • 15
    • 67650143291 scopus 로고    scopus 로고
    • Hydroxyapatite-ceramic-coated femoral components in young patients followed-up for 16 to 19 years: an update of a previous report
    • Shah N.N., Edge A.J., Clark D.W. Hydroxyapatite-ceramic-coated femoral components in young patients followed-up for 16 to 19 years: an update of a previous report. J Bone Joint Surg 2009, 91B:865.
    • (2009) J Bone Joint Surg , vol.91 B , pp. 865
    • Shah, N.N.1    Edge, A.J.2    Clark, D.W.3
  • 16
    • 33747891706 scopus 로고    scopus 로고
    • Tapered titanium porous plasma-sprayed femoral component in patients aged 40 years and younger
    • Ellison B., Berend K.R., Lombardi A.V., et al. Tapered titanium porous plasma-sprayed femoral component in patients aged 40 years and younger. J Arthroplasty 2006, 21(6 Suppl 2):32.
    • (2006) J Arthroplasty , vol.21 , Issue.6 SUPPL. 2 , pp. 32
    • Ellison, B.1    Berend, K.R.2    Lombardi, A.V.3
  • 17
    • 0024843779 scopus 로고
    • Wear analysis of retrieved alumina heads and sockets of hip prostheses
    • Dorlot J.M., Christel P., Meunier A. Wear analysis of retrieved alumina heads and sockets of hip prostheses. J Biomed Mater Res 1989, 23(A3 Suppl):299.
    • (1989) J Biomed Mater Res , vol.23 , Issue.A3 SUPPL. , pp. 299
    • Dorlot, J.M.1    Christel, P.2    Meunier, A.3
  • 19
    • 0026672302 scopus 로고
    • Biocompatibility of surgical-grade dense polycrystalline alumina
    • Christel P.S. Biocompatibility of surgical-grade dense polycrystalline alumina. Clin Orthop Relat Res 1992, 282:10.
    • (1992) Clin Orthop Relat Res , vol.282 , pp. 10
    • Christel, P.S.1
  • 20
    • 0033775008 scopus 로고    scopus 로고
    • Alumina-on-alumina total hip prostheses in patients 40 years of age or younger
    • Bizot P., Banallec L., Sedel L., et al. Alumina-on-alumina total hip prostheses in patients 40 years of age or younger. Clin Orthop Relat Res 2000, 379:68.
    • (2000) Clin Orthop Relat Res , vol.379 , pp. 68
    • Bizot, P.1    Banallec, L.2    Sedel, L.3
  • 21
    • 33745713070 scopus 로고    scopus 로고
    • Contemporary alumina-on-alumina total hip arthroplasty performed in patients younger than forty years: a 5-year minimum follow-up study
    • Yoo J.J., Kim Y.M., Yoon K.S., et al. Contemporary alumina-on-alumina total hip arthroplasty performed in patients younger than forty years: a 5-year minimum follow-up study. J Biomed Mater Res B Appl Biomater 2006, 78:70.
    • (2006) J Biomed Mater Res B Appl Biomater , vol.78 , pp. 70
    • Yoo, J.J.1    Kim, Y.M.2    Yoon, K.S.3
  • 22
    • 1642284142 scopus 로고    scopus 로고
    • Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years: a six- to 11-year evaluation
    • Bizot P., Hannouche D., Nizard R., et al. Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years: a six- to 11-year evaluation. J Bone Joint Surg 2004, 86B:190.
    • (2004) J Bone Joint Surg , vol.86 B , pp. 190
    • Bizot, P.1    Hannouche, D.2    Nizard, R.3
  • 23
    • 70449519276 scopus 로고    scopus 로고
    • Acetabular polyethylene wear and acetabular inclination and femoral offset
    • Little N.J., Busch C.A., Gallagher J.A., et al. Acetabular polyethylene wear and acetabular inclination and femoral offset. Clin Orthop Relat Res 2009, 467:11.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 11
    • Little, N.J.1    Busch, C.A.2    Gallagher, J.A.3
  • 24
    • 78951474453 scopus 로고    scopus 로고
    • Hip offset in total hip arthroplasty, quantitative measurement with navigation
    • Dastane M., Dorr L.D., Tarwala R., et al. Hip offset in total hip arthroplasty, quantitative measurement with navigation. Clin Orthop Relat Res 2011, 469:2.
    • (2011) Clin Orthop Relat Res , vol.469 , pp. 2
    • Dastane, M.1    Dorr, L.D.2    Tarwala, R.3
  • 25
    • 0346367048 scopus 로고    scopus 로고
    • Hip arthroscopy in the presence of dysplasia
    • Byrd J.W., Jones K.S. Hip arthroscopy in the presence of dysplasia. Arthroscopy 2003, 19:1055.
    • (2003) Arthroscopy , vol.19 , pp. 1055
    • Byrd, J.W.1    Jones, K.S.2
  • 26
    • 78549292127 scopus 로고    scopus 로고
    • Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis
    • Kim Y.H., Choi Y., Kim J.S. Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis. Int Orthop 2010, 34:1123.
    • (2010) Int Orthop , vol.34 , pp. 1123
    • Kim, Y.H.1    Choi, Y.2    Kim, J.S.3
  • 27
    • 55649088197 scopus 로고    scopus 로고
    • Osteolysis in third-generation alumina ceramic-on-ceramic hip bearings with severe impingement and titanium metallosis
    • Murali R., Bonar S.F., Kirsh G., et al. Osteolysis in third-generation alumina ceramic-on-ceramic hip bearings with severe impingement and titanium metallosis. J Arthroplasty 2008, 23:13.
    • (2008) J Arthroplasty , vol.23 , pp. 13
    • Murali, R.1    Bonar, S.F.2    Kirsh, G.3
  • 28
    • 0036056821 scopus 로고    scopus 로고
    • Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study
    • Hamadouche M., Boutin P., Daussange J., et al. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg 2002, 84A:69.
    • (2002) J Bone Joint Surg , vol.84 A , pp. 69
    • Hamadouche, M.1    Boutin, P.2    Daussange, J.3
  • 29
    • 0025350439 scopus 로고
    • Unsatisfactory results with a ceramic total hip prosthesis
    • Mahoney O.M., Dimon J.H. Unsatisfactory results with a ceramic total hip prosthesis. J Bone Joint Surg 1990, 72A:663.
    • (1990) J Bone Joint Surg , vol.72 A , pp. 663
    • Mahoney, O.M.1    Dimon, J.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.