메뉴 건너뛰기




Volumn 14, Issue 4, 2011, Pages 357-363

Biocompatibility and durability of Teflon-coated platinum-iridium wires implanted in the vitreous cavity

Author keywords

Biocompatibility; Retina; Teflon coated platinum iridium wires; Toxicity; Visual prosthesis

Indexed keywords

IRIDIUM; PLATINUM; POLITEF;

EID: 84855287650     PISSN: 14347229     EISSN: 16190904     Source Type: Journal    
DOI: 10.1007/s10047-011-0591-7     Document Type: Article
Times cited : (9)

References (25)
  • 1
    • 1842582778 scopus 로고    scopus 로고
    • The Artificial Silicon Retina Microchip for the Treatment of Vision Loss from Retinitis Pigmentosa
    • DOI 10.1001/archopht.122.4.460
    • Chow AY, Chow VY, Packo KH, Pollack JS, Peyman GA, Schuchard R. The artificial silicon retina microchip for the treatment of vision loss from retinitis pigmentosa. Arch Ophthalmol. 2004;122:460-9. (Pubitemid 38456280)
    • (2004) Archives of Ophthalmology , vol.122 , Issue.4 , pp. 460-469
    • Chow, A.Y.1    Chow, V.Y.2    Packo, K.H.3    Pollack, J.S.4    Peyman, G.A.5    Schuchard, R.6
  • 3
    • 0345014794 scopus 로고    scopus 로고
    • Methods and Perceptual Thresholds for Short-Term Electrical Stimulation of Human Retina with Microelectrode Arrays
    • DOI 10.1167/iovs.02-0819
    • Rizzo JF 3rd, Wyatt J, Loewenstein J, Kelly S, Shire D. Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode arrays. Invest Ophthalmol Vis Sci. 2003;44:5355-61. (Pubitemid 37475410)
    • (2003) Investigative Ophthalmology and Visual Science , vol.44 , Issue.12 , pp. 5355-5361
    • Rizzo III, J.F.1    Wyatt, J.2    Loewenstein, J.3    Kelly, S.4    Shire, D.5
  • 5
    • 0036039162 scopus 로고    scopus 로고
    • The subretinal implant: Can microphotodiode arrays replace degenerated retinal photoreceptors to restore vision?
    • DOI 10.1159/000064650
    • Zrenner E. The subretinal implant: can microphotodiode arrays replace degenerated retinal photoreceptors to restore vision? Ophthalmologica. 2002;216:8-20. (Pubitemid 35007617)
    • (2002) Ophthalmologica , vol.216 , Issue.SUPPL. 1 , pp. 8-20
    • Zrenner, E.1
  • 8
    • 33847632184 scopus 로고    scopus 로고
    • A new approach towards a minimal invasive retina implant
    • DOI 10.1088/1741-2560/4/1/S05, PII S1741256007354876, S05
    • Gerding H. A new approach towards a minimal invasive retina implant. J Neural Eng. 2007;4:S30-7. (Pubitemid 46357446)
    • (2007) Journal of Neural Engineering , vol.4 , Issue.1
    • Gerding, H.1
  • 9
    • 59749096726 scopus 로고    scopus 로고
    • Intraorbital optic nerve stimulation with penetrating electrodes: In vivo electrophysiology study in rabbits
    • Li L, Cao P, Sun M, Chai X, Wu K, Xu X, Li X, Ren Q. Intraorbital optic nerve stimulation with penetrating electrodes: in vivo electrophysiology study in rabbits. Graefes Arch Clin Exp Ophthalmol. 2009;247:349-61.
    • (2009) Graefes Arch Clin Exp Ophthalmol , vol.247 , pp. 349-361
    • Li, L.1    Cao, P.2    Sun, M.3    Chai, X.4    Wu, K.5    Xu, X.6    Li, X.7    Ren, Q.8
  • 12
    • 0942287247 scopus 로고    scopus 로고
    • Electrophysiological Studies of the Feasibility of Suprachoroidal- Transretinal Stimulation for Artificial Vision in Normal and RCS Rats
    • DOI 10.1167/iovs.02-1268
    • Kanda H, Morimoto T, Fujikado T, Tano Y, Fukuda Y, Sawai H. Electrophysiological studies of the feasibility of suprachoroidaltransretinal stimulation for artificial vision in normal and RCS rats. Invest Ophthalmol Vis Sci. 2004;45:560-6. (Pubitemid 38140515)
    • (2004) Investigative Ophthalmology and Visual Science , vol.45 , Issue.2 , pp. 560-566
    • Kanda, H.1    Morimoto, T.2    Fujikado, T.3    Tano, Y.4    Fukuda, Y.5    Sawai, H.6
  • 18
    • 0028288169 scopus 로고
    • Treatment and prevention of tethered and retethered spinal cord using a Gore-Tex surgical membrane
    • Inoue HK, Kobayashi S, Ohbayashi K, Kohga H, Nakamura M. Treatment and prevention of tethered and retethered spinal cord using a Gore-Tex surgical membrane. J Neurosurg. 1994;80:689-93. (Pubitemid 24100290)
    • (1994) Journal of Neurosurgery , vol.80 , Issue.4 , pp. 689-693
    • Inoue, H.K.1    Kobayashi, S.2    Ohbayashi, K.3    Kohga, H.4    Nakamura, M.5
  • 21
    • 0018888418 scopus 로고
    • The acceptance of a vitreous carbon alloplastic material, Proplast, in the rabbit eye
    • Barber JC, Feaster F, Priour D. The acceptance of a vitreous carbon alloplastic material, Proplast, in the rabbit eye. Invest Ophthalmol Vis Sci. 1980;19:182-91. (Pubitemid 10129458)
    • (1980) Investigative Ophthalmology and Visual Science , vol.19 , Issue.2 , pp. 182-191
    • Barber, J.C.1    Feaster, F.2    Priour, D.3
  • 22
    • 0035052431 scopus 로고    scopus 로고
    • Expanded polytetrafluoroethylene reinforcement material in glaucoma drain surgery
    • Jacob T, LaCour OJ, Burgoyne CF, LaFleur PK, Duzman E. Expanded polytetrafluoroethylene reinforcement material in glaucoma drain surgery. J Glaucoma. 2001;10:115-20. (Pubitemid 32298241)
    • (2001) Journal of Glaucoma , vol.10 , Issue.2 , pp. 115-120
    • Jacob, J.T.1    LaCour, O.J.2    Burgoyne, C.F.3    LaFleur, P.K.4    Duzman, E.5
  • 23
    • 0025002998 scopus 로고
    • Inferior rectus muscle entrapped by Teflon implant after orbital floor fracture repair
    • Mauriello JA Jr. Inferior rectus muscle entrapped by Teflon implant after orbital floor fracture repair. Ophthalmic Plast Reconstr Surg. 1990;6:218-20.
    • (1990) Ophthalmic Plast Reconstr Surg , vol.6 , pp. 218-220
    • Mauriello Jr., J.A.1
  • 24
    • 33645473138 scopus 로고    scopus 로고
    • Polytetrafluoroethylene (Goretex) for muscle elongation in the surgical treatment of strabismus with restricted motility
    • Langmann A, Lindner S, Wackernagel W, Koch M, Horantner R. Polytetrafluoroethylene (Goretex) for muscle elongation in the surgical treatment of strabismus with restricted motility. Acta Ophthalmol Scand. 2006;84:250-3.
    • (2006) Acta Ophthalmol Scand , vol.84 , pp. 250-253
    • Langmann, A.1    Lindner, S.2    Wackernagel, W.3    Koch, M.4    Horantner, R.5
  • 25
    • 68249138672 scopus 로고    scopus 로고
    • Study on MCP-1 related to inflammation induced by biomaterials
    • Ding T, Sun J, Zhang P. Study on MCP-1 related to inflammation induced by biomaterials. Biomed Mater. 2009;4:35005.
    • (2009) Biomed Mater , vol.4 , pp. 35005
    • Ding, T.1    Sun, J.2    Zhang, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.