메뉴 건너뛰기




Volumn 4, Issue 12, 2011, Pages 1271-1280

Head-to-head comparison of the neointimal response between metallic and bioresorbable everolimus-eluting scaffolds using optical coherence tomography

(19)  Gomez Lara, Josep a   Brugaletta, Salvatore a   Farooq, Vasim a   Onuma, Yoshinobu a   Diletti, Roberto a   Windecker, Stephan e   Thuesen, Leif f   McClean, Dougal g   Koolen, Jacques d   Whitbourn, Robert i   Dudek, Dariusz j   Smits, Pieter C b   Chevalier, Bernard k   Regar, Evelyn a   Veldhof, Susan l   Rapoza, Richard l   Ormiston, John A h   Garcia Garcia, Hector M a,c   Serruys, Patrick W a  


Author keywords

bioresorbable vascular scaffold; drug eluting stent(s); minimal lumen diameter; neointimal thickness; optical coherence tomography; stent scaffold thrombosis

Indexed keywords

EVEROLIMUS;

EID: 84255168694     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2011.08.016     Document Type: Article
Times cited : (65)

References (28)
  • 1
    • 77956151407 scopus 로고    scopus 로고
    • Coronary stents: Current status
    • S. Garg, P.W. Serruys Coronary stents: current status J Am Coll Cardiol 56 Suppl 10 2010 S1 S42
    • (2010) J Am Coll Cardiol , vol.56 , Issue.SUPPL. 10
    • Garg, S.1    Serruys, P.W.2
  • 2
    • 77954746572 scopus 로고    scopus 로고
    • Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents
    • ODESSA Trial Investigators
    • G. Guagliumi, G. Musumeci, V. Sirbu ODESSA Trial Investigators Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents J Am Coll Cardiol Intv 3 2010 531 539
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 531-539
    • Guagliumi, G.1    Musumeci, G.2    Sirbu, V.3
  • 4
    • 34248219973 scopus 로고    scopus 로고
    • Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization
    • DOI 10.1161/CIRCULATIONAHA.107.693739
    • A.V. Finn, M. Joner, G. Nakazawa Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization Circulation 115 2007 2435 2441 (Pubitemid 46717966)
    • (2007) Circulation , vol.115 , Issue.18 , pp. 2435-2441
    • Finn, A.V.1    Joner, M.2    Nakazawa, G.3    Kolodgie, F.4    Newell, J.5    John, M.C.6    Gold, H.K.7    Virmani, R.8
  • 5
    • 77951001904 scopus 로고    scopus 로고
    • Duration of dual antiplatelet therapy after implantation of drug-eluting stents
    • S.J. Park, D.W. Park, Y.H. Kim Duration of dual antiplatelet therapy after implantation of drug-eluting stents N Engl J Med 362 2010 1374 1382
    • (2010) N Engl J Med , vol.362 , pp. 1374-1382
    • Park, S.J.1    Park, D.W.2    Kim, Y.H.3
  • 6
    • 77954621329 scopus 로고    scopus 로고
    • Comparisons of baseline demographics, clinical presentation, and long-term outcome among patients with early, late, and very late stent thrombosis of sirolimus-eluting stents: Observations from the Registry of Stent Thrombosis for Review and Reevaluation (RESTART)
    • T. Kimura, T. Morimoto, K. Kozuma Comparisons of baseline demographics, clinical presentation, and long-term outcome among patients with early, late, and very late stent thrombosis of sirolimus-eluting stents: Observations from the Registry of Stent Thrombosis for Review and Reevaluation (RESTART) Circulation 122 2010 52 61
    • (2010) Circulation , vol.122 , pp. 52-61
    • Kimura, T.1    Morimoto, T.2    Kozuma, K.3
  • 7
    • 78650171486 scopus 로고    scopus 로고
    • Intracoronary optical coherence tomography and histology at 1 month and 2, 3, and 4 years after implantation of everolimus-eluting bioresorbable vascular scaffolds in a porcine coronary artery model An attempt to decipher the human optical coherence tomography images in the ABSORB trial
    • Y. Onuma, P.W. Serruys, L.E. Perkins Intracoronary optical coherence tomography and histology at 1 month and 2, 3, and 4 years after implantation of everolimus-eluting bioresorbable vascular scaffolds in a porcine coronary artery model An attempt to decipher the human optical coherence tomography images in the ABSORB trial Circulation 122 2010 2288 2300
    • (2010) Circulation , vol.122 , pp. 2288-2300
    • Onuma, Y.1    Serruys, P.W.2    Perkins, L.E.3
  • 8
    • 61849110613 scopus 로고    scopus 로고
    • A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods
    • P.W. Serruys, J.A. Ormiston, Y. Onuma A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods Lancet 373 2009 897 910
    • (2009) Lancet , vol.373 , pp. 897-910
    • Serruys, P.W.1    Ormiston, J.A.2    Onuma, Y.3
  • 9
    • 73649133689 scopus 로고    scopus 로고
    • Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation
    • A. Murata, D. Wallace-Bradley, A. Tellez Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation J Am Coll Cardiol Img 3 2010 76 84
    • (2010) J Am Coll Cardiol Img , vol.3 , pp. 76-84
    • Murata, A.1    Wallace-Bradley, D.2    Tellez, A.3
  • 10
    • 75249103029 scopus 로고    scopus 로고
    • Intracoronary thrombus formation after drug-eluting stents implantation: Optical coherence tomographic study
    • J.S. Kim, M.K. Hong, C. Fan Intracoronary thrombus formation after drug-eluting stents implantation: optical coherence tomographic study Am Heart J 159 2010 278 283
    • (2010) Am Heart J , vol.159 , pp. 278-283
    • Kim, J.S.1    Hong, M.K.2    Fan, C.3
  • 11
    • 77953748337 scopus 로고    scopus 로고
    • The fate of incomplete stent apposition with drug-eluting stents: An optical coherence tomography-based natural history study
    • Y. Ozaki, M. Okumura, T.F. Ismail The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study Eur Heart J 31 2010 1470 1476
    • (2010) Eur Heart J , vol.31 , pp. 1470-1476
    • Ozaki, Y.1    Okumura, M.2    Ismail, T.F.3
  • 12
    • 78650108611 scopus 로고    scopus 로고
    • Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: Six-month clinical and imaging outcomes
    • P.W. Serruys, Y. Onuma, J.A. Ormiston Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: six-month clinical and imaging outcomes Circulation 122 2010 2301 2312
    • (2010) Circulation , vol.122 , pp. 2301-2312
    • Serruys, P.W.1    Onuma, Y.2    Ormiston, J.A.3
  • 13
    • 77954392890 scopus 로고    scopus 로고
    • Comparison of zotarolimus-eluting and everolimus-eluting coronary stents
    • P.W. Serruys, S. Silber, S. Garg Comparison of zotarolimus-eluting and everolimus-eluting coronary stents N Engl J Med 363 2010 136 146
    • (2010) N Engl J Med , vol.363 , pp. 136-146
    • Serruys, P.W.1    Silber, S.2    Garg, S.3
  • 14
    • 80054071576 scopus 로고    scopus 로고
    • Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. A fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: An optical coherence tomography substudy from the RESOLUTE All Comers trial
    • J.L. Gutierrez-Chico, R.J. van Geuns, E. Regar Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial Eur Heart J 32 2011 2454 2463
    • (2011) Eur Heart J , vol.32 , pp. 2454-2463
    • Gutierrez-Chico, J.L.1    Van Geuns, R.J.2    Regar, E.3
  • 15
    • 77249092502 scopus 로고    scopus 로고
    • Expert's OCT Review Document Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: Physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis
    • F. Prati, E. Regar, G.S. Mintz Expert's OCT Review Document Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis Eur Heart J 31 2010 401 415
    • (2010) Eur Heart J , vol.31 , pp. 401-415
    • Prati, F.1    Regar, E.2    Mintz, G.S.3
  • 16
    • 79551692953 scopus 로고    scopus 로고
    • A comparative assessment by optical coherence tomography of the performance of the first and second generation of the everolimus-eluting bioresorbable vascular scaffolds
    • J. Gomez-Lara, S. Brugaletta, R. Diletti A comparative assessment by optical coherence tomography of the performance of the first and second generation of the everolimus-eluting bioresorbable vascular scaffolds Eur Heart J 32 2011 294 304
    • (2011) Eur Heart J , vol.32 , pp. 294-304
    • Gomez-Lara, J.1    Brugaletta, S.2    Diletti, R.3
  • 17
    • 67650361247 scopus 로고    scopus 로고
    • Optical coherence tomography patterns of stent restenosis
    • N. Gonzalo, P.W. Serruys, T. Okamura Optical coherence tomography patterns of stent restenosis Am Heart J 158 2009 284 293
    • (2009) Am Heart J , vol.158 , pp. 284-293
    • Gonzalo, N.1    Serruys, P.W.2    Okamura, T.3
  • 20
    • 67651119696 scopus 로고    scopus 로고
    • Comparison of inflammatory response after implantation of sirolimus- and paclitaxel-eluting stents in porcine coronary arteries
    • G.J. Wilson, G. Nakazawa, R.S. Schwartz Comparison of inflammatory response after implantation of sirolimus- and paclitaxel-eluting stents in porcine coronary arteries Circulation 120 2009 141 149
    • (2009) Circulation , vol.120 , pp. 141-149
    • Wilson, G.J.1    Nakazawa, G.2    Schwartz, R.S.3
  • 21
    • 67649867101 scopus 로고    scopus 로고
    • Delayed neointimalization on sirolimus-eluting stents: 6-month and 12-month follow up by optical coherence tomography
    • H. Katoh, J. Shite, T. Shinke Delayed neointimalization on sirolimus-eluting stents: 6-month and 12-month follow up by optical coherence tomography Circ J 73 2009 1033 1037
    • (2009) Circ J , vol.73 , pp. 1033-1037
    • Katoh, H.1    Shite, J.2    Shinke, T.3
  • 22
    • 73349096901 scopus 로고    scopus 로고
    • Long-term follow-up of neointimal coverage of sirolimus-eluting stents: Evaluation with optical coherence tomography
    • K. Ishigami, S. Uemura, Y. Morikawa Long-term follow-up of neointimal coverage of sirolimus-eluting stents: evaluation with optical coherence tomography Circ J 73 2009 2300 2307
    • (2009) Circ J , vol.73 , pp. 2300-2307
    • Ishigami, K.1    Uemura, S.2    Morikawa, Y.3
  • 23
    • 75749123502 scopus 로고    scopus 로고
    • Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation
    • J.S. Kim, T.H. Kim, C. Fan Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation Circ J 74 2010 320 326
    • (2010) Circ J , vol.74 , pp. 320-326
    • Kim, J.S.1    Kim, T.H.2    Fan, C.3
  • 24
    • 72049117874 scopus 로고    scopus 로고
    • Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: Comparison with sirolimus-eluting stents
    • J.S. Kim, I.K. Jang, T.H. Kim Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents Heart 95 2009 1907 1912
    • (2009) Heart , vol.95 , pp. 1907-1912
    • Kim, J.S.1    Jang, I.K.2    Kim, T.H.3
  • 25
    • 80052998014 scopus 로고    scopus 로고
    • Serial analysis of the malapposed and uncovered struts of the new generation of everolimus-eluting bioresorbable scaffold using optical coherence tomography
    • J. Gomez-Lara, M. Radu, S. Brugaletta Serial analysis of the malapposed and uncovered struts of the new generation of everolimus-eluting bioresorbable scaffold using optical coherence tomography J Am Coll Cardiol Intv 4 2011 992 1001
    • (2011) J Am Coll Cardiol Intv , vol.4 , pp. 992-1001
    • Gomez-Lara, J.1    Radu, M.2    Brugaletta, S.3
  • 26
    • 33846828736 scopus 로고    scopus 로고
    • Prevention of Premature Discontinuation of Dual Antiplatelet Therapy in Patients With Coronary Artery Stents. A Science Advisory From the American Heart Association, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, American College of Surgeons, and American Dental Association
    • DOI 10.1016/j.jacc.2007.01.003, PII S073510970700054X
    • C.L. Grines, R.O. Bonow, D.E. Casey Jr. Prevention of premature discontinuation of dual antiplatelet therapy in patients with coronary artery stents: a science advisory from the American Heart Association, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, American College of Surgeons, and American Dental Association, with representation from the American College of Physicians J Am Coll Cardiol 49 2007 734 739 (Pubitemid 46210116)
    • (2007) Journal of the American College of Cardiology , vol.49 , Issue.6 , pp. 734-739
    • Grines, C.L.1    Bonow, R.O.2    Casey Jr., D.E.3    Gardner, T.J.4    Lockhart, P.B.5    Moliterno, D.J.6    O'Gara, P.7    Whitlow, P.8
  • 27
    • 0032534056 scopus 로고    scopus 로고
    • Intimal hyperplasia thickness at follow-up is independent of stent size: A serial intravascular ultrasound study
    • DOI 10.1016/S0002-9149(98)00603-1, PII S0002914998006031
    • R. Hoffmann, G.S. Mintz, A.D. Pichard, K.M. Kent, L.F. Satler, M.B. Leon Intimal hyperplasia thickness at follow-up is independent of stent size: a serial intravascular ultrasound study Am J Cardiol 82 1998 1168 1172 (Pubitemid 28541269)
    • (1998) American Journal of Cardiology , vol.82 , Issue.10 , pp. 1168-1172
    • Hoffmann, R.1    Mintz, G.S.2    Pichard, A.D.3    Kent, K.M.4    Satler, L.F.5    Leon, M.B.6
  • 28
    • 73649134035 scopus 로고    scopus 로고
    • Sirolimus-eluting stent implantation in small coronary arteries: A three dimensional intravascular ultrasound study from the SIRIUS trial
    • H. Kaneda, J. Ako, M. Terashima Sirolimus-eluting stent implantation in small coronary arteries: a three dimensional intravascular ultrasound study from the SIRIUS trial Int J Cardiol 138 2010 126 130
    • (2010) Int J Cardiol , vol.138 , pp. 126-130
    • Kaneda, H.1    Ako, J.2    Terashima, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.