메뉴 건너뛰기




Volumn 32, Issue 3, 2011, Pages 294-304

A comparative assessment by optical coherence tomography of the performance of the first and second generation of the everolimus-eluting bioresorbable vascular scaffolds

Author keywords

Bioresorbable vascular scaffold; Bioresorption; Optical coherence tomography; Shrinkage

Indexed keywords

EVEROLIMUS; TISSUE SCAFFOLD;

EID: 79551692953     PISSN: 0195668X     EISSN: 15229645     Source Type: Journal    
DOI: 10.1093/eurheartj/ehq458     Document Type: Article
Times cited : (58)

References (28)
  • 1
    • 40649083620 scopus 로고    scopus 로고
    • A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): A prospective open-label trial
    • DOI 10.1016/S0140-6736(08)60415-8, PII S0140673608604158
    • Ormiston JA, Serruys PW, Regar E, Dudek D, Thuesen L, Webster MW, Onuma Y, Garcia-Garcia HM, McGreevy R, Veldhof S. A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial. Lancet 2008;371: 899-907. (Pubitemid 351384734)
    • (2008) The Lancet , vol.371 , Issue.9616 , pp. 899-907
    • Ormiston, J.A.1    Serruys, P.W.2    Regar, E.3    Dudek, D.4    Thuesen, L.5    Webster, M.W.6    Onuma, Y.7    Garcia-Garcia, H.M.8    McGreevy, R.9    Veldhof, S.10
  • 3
    • 77956166657 scopus 로고    scopus 로고
    • In vivo evalution of stent strut distribution patterns in the bioabsorbable everolimus-eluting device: An OCT ad hoc analysis of the revision 1.0 and revision 1.1 stent design in the ABSORB clinical trial
    • Okamura T, Garg S, Gutierrez-Chico JL, Shin ES, Onuma Y, Garcia-Garcia HM, Rapoza R, Sudhir K, Regar E, Serruys PW. In vivo evalution of stent strut distribution patterns in the bioabsorbable everolimus-eluting device: an OCT ad hoc analysis of the revision 1.0 and revision 1.1 stent design in the ABSORB clinical trial. EuroIntervention 2010;5:932-938.
    • (2010) EuroIntervention , vol.5 , pp. 932-938
    • Okamura, T.1    Garg, S.2    Gutierrez-Chico, J.L.3    Shin, E.S.4    Onuma, Y.5    Garcia-Garcia, H.M.6    Rapoza, R.7    Sudhir, K.8    Regar, E.9    Serruys, P.W.10
  • 5
    • 26444450457 scopus 로고    scopus 로고
    • In vivo volumetric analysis of coronary stent using optical coherence tomography with a novel balloon occlusion-flushing catheter: A comparison with intravascular ultrasound
    • DOI 10.1016/j.ultrasmedbio.2005.05.010, PII S0301562905002450
    • Kawase Y, Hoshino K, Yoneyama R, McGregor J, Hajjar RJ, Jang IK, Hayase M. In vivo volumetric analysis of coronary stent using optical coherence tomography with a novel balloon occlusion-flushing catheter: a comparison with intravascular ultrasound. Ultrasound Med Biol 2005;31:1343-1349. (Pubitemid 41434050)
    • (2005) Ultrasound in Medicine and Biology , vol.31 , Issue.10 , pp. 1343-1349
    • Kawase, Y.1    Hoshino, K.2    Yoneyama, R.3    McGregor, J.4    Hajjar, R.J.5    Jang, I.-K.6    Hayase, M.7
  • 6
    • 41949118345 scopus 로고    scopus 로고
    • In vivo comparison between optical coherence tomography and intravascular ultrasound for detecting small degrees of in-stent neointima after stent implantation
    • DOI 10.1016/j.jcin.2007.12.007, PII S193687980800071X
    • Suzuki Y, Ikeno F, Koizumi T, Tio F, Yeung AC, Yock PG, Fitzgerald PJ, Fearon WF. In vivo comparison between optical coherence tomography and intravascular ultrasound for detecting small degrees of in-stent neointima after stent implantation. JACC Cardiovasc Interv 2008;1:168-173. (Pubitemid 351506553)
    • (2008) JACC: Cardiovascular Interventions , vol.1 , Issue.2 , pp. 168-173
    • Suzuki, Y.1    Ikeno, F.2    Koizumi, T.3    Tio, F.4    Yeung, A.C.5    Yock, P.G.6    Fitzgerald, P.J.7    Fearon, W.F.8
  • 7
    • 77956167592 scopus 로고    scopus 로고
    • Three-year results of clinical follow-up after a bioresorbable everolimus-eluting scaffold in patients with de novo coronary artery disease: The ABSORB trial
    • Onuma Y, Serruys PW, Ormiston JA, Regar E, Webster M, Thuesen L, Dudek D, Veldhof S, Rapoza R. Three-year results of clinical follow-up after a bioresorbable everolimus-eluting scaffold in patients with de novo coronary artery disease: the ABSORB trial. EuroInterv 2010;6:447-453.
    • (2010) EuroInterv , vol.6 , pp. 447-453
    • Onuma, Y.1    Serruys, P.W.2    Ormiston, J.A.3    Regar, E.4    Webster, M.5    Thuesen, L.6    Dudek, D.7    Veldhof, S.8    Rapoza, R.9
  • 8
    • 0021997026 scopus 로고
    • Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms
    • Reiber JH, Serruys PW, Kooijman CJ, Wijns W, Slager CJ, Gerbrands JJ, Schuurbiers JC, den Boer A, Hugenholtz PG. Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quanti-tation of coronary cineangiograms. Circulation 1985;71:280-288. (Pubitemid 15157088)
    • (1985) Circulation , vol.71 , Issue.2 , pp. 280-288
    • Reiber, J.H.C.1    Serruys, P.W.2    Kooijman, C.J.3
  • 10
    • 35349018576 scopus 로고    scopus 로고
    • Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: Insights from the ABSORB and SPIRIT trials
    • DOI 10.1002/ccd.21136
    • Tanimoto S, Serruys PW, Thuesen L, Dudek D, de Bruyne B, Chevalier B, Ormiston JA. Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials. Catheter Cardiovasc Interv 2007;70:515-523. (Pubitemid 47597022)
    • (2007) Catheterization and Cardiovascular Interventions , vol.70 , Issue.4 , pp. 515-523
    • Tanimoto, S.1    Serruys, P.W.2    Thuesen, L.3    Dudek, D.4    De Bruyne, B.5    Chevalier, B.6    Ormiston, J.A.7
  • 12
    • 78650171486 scopus 로고    scopus 로고
    • Intracoronary optical coherence tomography (OCT) and histology at 1 month at 2 3 and 4 years after implantation of everolimus-eluting bioresorbable vascular scaffolds in a porcine coronary artery model: An attempt to decipher the human OCT images in the ABSORB trial
    • Published online ahead of print 25 October 2010
    • Onuma Y, Serruys P, Perkins L, Okamura T, Gonzalo N, Garcia-Garcia HM, Regar E, Kamberi M, Powers JC, Rapoza R, van Beusekom H, van der Giessen W, Virmani R. Intracoronary optical coherence tomography (OCT) and histology at 1 month, at 2, 3 and 4 years after implantation of everolimus-eluting bioresorbable vascular scaffolds in a porcine coronary artery model: An attempt to decipher the human OCT images in the ABSORB trial. Circulation 2010; Published online ahead of print 25 October 2010.
    • (2010) Circulation
    • Onuma, Y.1    Serruys, P.2    Perkins, L.3    Okamura, T.4    Gonzalo, N.5    Garcia-Garcia, H.M.6    Regar, E.7    Kamberi, M.8    Powers, J.C.9    Rapoza, R.10    Van Beusekom, H.11    Van Der Giessen, W.12    Virmani, R.13
  • 13
    • 0030671369 scopus 로고    scopus 로고
    • ECG-gated three-dimensional intravascular ultrasound: Feasibility and reproducibility of the automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans
    • von Birgelen C, de Vrey EA, Mintz GS, Nicosia A, Bruining N, Li W, Slager CJ, Roelandt JR, Serruys PW, de Feyter PJ. ECG-gated three-dimensional intravascu-lar ultrasound: feasibility and reproducibility of the automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans. Circulation 1997;96: 2944-2952. (Pubitemid 27500094)
    • (1997) Circulation , vol.96 , Issue.9 , pp. 2944-2952
    • Von Birgelen, C.1    De Vrey, E.A.2    Mintz, G.S.3    Nicosia, A.4    Bruining, N.5    Li, W.6    Slager, C.J.7    Roelandt, J.R.T.C.8    Serruys, P.W.9    De Feyter, P.J.10
  • 14
    • 79551690436 scopus 로고    scopus 로고
    • ABC's of bioabsorption: Application of lactide based polymers in fully resorbable cardiovascular stents
    • Aalst M, Eenink M, Kruft M, van Tuil R. ABC's of bioabsorption: application of lactide based polymers in fully resorbable cardiovascular stents. Eurointervention 2009;5(Suppl. F):F23-F27.
    • (2009) Eurointervention , vol.5 , Issue.SUPPL. F
    • Aalst, M.1    Eenink, M.2    Kruft, M.3    Van Tuil, R.4
  • 22
    • 77956159301 scopus 로고    scopus 로고
    • Engineering a bioresorbable stent: The REVA programme update
    • Pollman M. Engineering a bioresorbable stent: the REVA programme update. Euro-Intervention 2009;5(Suppl. F):F54-F57.
    • (2009) Euro-Intervention , vol.5 , Issue.SUPPL. F
    • Pollman, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.