메뉴 건너뛰기




Volumn 82, Issue 10, 1998, Pages 1168-1172

Intimal hyperplasia thickness at follow-up is independent of stent size: A serial intravascular ultrasound study

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTERY DIAMETER; ARTERY INTIMA PROLIFERATION; ARTICLE; CONTROLLED STUDY; CORONARY ARTERY DISEASE; FEMALE; FOLLOW UP; HUMAN; INTRAVASCULAR ULTRASOUND; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; STENT;

EID: 0032534056     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9149(98)00603-1     Document Type: Article
Times cited : (61)

References (17)
  • 5
    • 0031018844 scopus 로고    scopus 로고
    • Serial follow-up after optimized ultrasound-guided deployment of Palmaz-Schatz stents. In-stent neointimal proliferation without significant reference segment response
    • 5. Mudra H, Regar E, Klauss V, Werner F, Henneke KH, Sbarouni E, Theisen K. Serial follow-up after optimized ultrasound-guided deployment of Palmaz-Schatz stents. In-stent neointimal proliferation without significant reference segment response. Circulation 1997;95:363-370.
    • (1997) Circulation , vol.95 , pp. 363-370
    • Mudra, H.1    Regar, E.2    Klauss, V.3    Werner, F.4    Henneke, K.H.5    Sbarouni, E.6    Theisen, K.7
  • 9
    • 0026592026 scopus 로고
    • The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting
    • 9. Kuntz RE, Safian RD, Carrozza JP, Fishman RF, Mansour M, Baim DS. The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting. Circulation 1992;86:1827-1835.
    • (1992) Circulation , vol.86 , pp. 1827-1835
    • Kuntz, R.E.1    Safian, R.D.2    Carrozza, J.P.3    Fishman, R.F.4    Mansour, M.5    Baim, D.S.6
  • 11
    • 0025189773 scopus 로고
    • Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions. In vivo comparison to cineangiography
    • 11. Nissen SE, Grines CL, Gurley JC, Sublett K, Haynie D, Diaz C, Booth DC, DeMaria AN. Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions. In vivo comparison to cineangiography. Circulation 1990;81:660-666.
    • (1990) Circulation , vol.81 , pp. 660-666
    • Nissen, S.E.1    Grines, C.L.2    Gurley, J.C.3    Sublett, K.4    Haynie, D.5    Diaz, C.6    Booth, D.C.7    DeMaria, A.N.8
  • 14
    • 0027458580 scopus 로고
    • Histology after stenting of human saphenous vein bypass grafts: Observations from surgically excised grafts 3 to 320 days after stent implantation
    • 14. van Beusekom HM, van der Giessen WJ, van Suylen RJ, Bos E, Bosman FT, Serruys PW. Histology after stenting of human saphenous vein bypass grafts: observations from surgically excised grafts 3 to 320 days after stent implantation. J Am Coll Cardiol 1993;21:45-54.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 45-54
    • Van Beusekom, H.M.1    Van Der Giessen, W.J.2    Van Suylen, R.J.3    Bos, E.4    Bosman, F.T.5    Serruys, P.W.6
  • 15
    • 0027439822 scopus 로고
    • Intravascular stents: Tissue-stent interactions and design considerations
    • 15. Palmaz JC. Intravascular stents: tissue-stent interactions and design considerations. Am J Rentgenol 1993;160:613-618.
    • (1993) Am J Rentgenol , vol.160 , pp. 613-618
    • Palmaz, J.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.