메뉴 건너뛰기




Volumn 76, Issue 1, 2012, Pages 102-108

Clinical outcomes and hemodynamics of the 19-mm Perimount Magna bioprosthesis in an aortic position-comparison with the 19-mm Medtronic Mosaic Ultra valve

Author keywords

Surgery; Valves; Valvular diseases

Indexed keywords

AGED; AORTA STENOSIS; AORTA VALVE REPLACEMENT; ARTICLE; CARPENTIER EDWARDS BIOPROSTHESIS; CLINICAL EFFECTIVENESS; COMPARATIVE STUDY; CONTROLLED STUDY; FEMALE; FOLLOW UP; HEART LEFT VENTRICLE AORTIC PRESSURE GRADIENT; HEART LEFT VENTRICLE MASS; HEMODYNAMIC PARAMETERS; HEMODYNAMICS; HUMAN; M MODE ECHOCARDIOGRAPHY; MAJOR CLINICAL STUDY; MALE; MORTALITY; OUTCOME ASSESSMENT; PATIENT SATISFACTION; POSTOPERATIVE PERIOD; TRANSTHORACIC ECHOCARDIOGRAPHY;

EID: 84255168610     PISSN: 13469843     EISSN: 13474820     Source Type: Journal    
DOI: 10.1253/circj.CJ-11-0728     Document Type: Article
Times cited : (21)

References (20)
  • 1
    • 77955084165 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis
    • Hara H, Schwartz RS. Transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis. Circ J 2010; 74: 1513-1517.
    • (2010) Circ J , vol.74 , pp. 1513-1517
    • Hara, H.1    Schwartz, R.S.2
  • 2
    • 78651234444 scopus 로고    scopus 로고
    • Pathophysiology of aortic stenosis and approach to treatment with percutaneous valve implantation
    • Spaccarotella C, Mongiardo A, Indolfi C. Pathophysiology of aortic stenosis and approach to treatment with percutaneous valve implantation. Circ J 2010; 75: 11-19.
    • (2010) Circ J , vol.75 , pp. 11-19
    • Spaccarotella, C.1    Mongiardo, A.2    Indolfi, C.3
  • 3
    • 0033819953 scopus 로고    scopus 로고
    • Hemodynamic and clinical impact of prosthesis- patient mismatch in the aortic valve position and its prevention
    • Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis- patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol 2000; 36: 1131-1141.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 1131-1141
    • Pibarot, P.1    Dumesnil, J.G.2
  • 4
    • 0028034841 scopus 로고
    • Prediction of postoperative exercise tolerance after aortic valve replacement
    • Hirooka K, Kawazoe K, Kosakai Y. Prediction of postoperative exercise tolerance after aortic valve replacement. Ann Thorac Surg 1994; 58: 1626-1630.
    • (1994) Ann Thorac Surg , vol.58 , pp. 1626-1630
    • Hirooka, K.1    Kawazoe, K.2    Kosakai, Y.3
  • 5
    • 0017331788 scopus 로고
    • Echocardiographic determination of left ventricular mass in man: Anatomic validation of the method
    • Devereux RB, Reichek N. Echocardiographic determination of left ventricular mass in man: Anatomic validation of the method. Circulation 1977; 55: 613-618.
    • (1977) Circulation , vol.55 , pp. 613-618
    • Devereux, R.B.1    Reichek, N.2
  • 6
    • 0031971981 scopus 로고    scopus 로고
    • Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status, morbidity, and mortality after aortic valve replacement with a bioprosthetic heart valve
    • Pibarot P, Dumesnil JG, Lemieux M, Cartier P, Metras J, Durand LG. Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status, morbidity, and mortality after aortic valve replacement with a bioprosthetic heart valve. J Heart Valve Dis 1998; 7: 211-218.
    • (1998) J Heart Valve Dis , vol.7 , pp. 211-218
    • Pibarot, P.1    Dumesnil, J.G.2    Lemieux, M.3    Cartier, P.4    Metras, J.5    Durand, L.G.6
  • 7
    • 0042859863 scopus 로고    scopus 로고
    • Impact of prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    • Blais C, Dumesnil JG, Baillot R, Simard S, Doyle D, Pibarot P. Impact of prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 2003; 108: 983-988.
    • (2003) Circulation , vol.108 , pp. 983-988
    • Blais, C.1    Dumesnil, J.G.2    Baillot, R.3    Simard, S.4    Doyle, D.5    Pibarot, P.6
  • 8
    • 70349785750 scopus 로고    scopus 로고
    • The complete supraannular concept. In vivo hemodynamics of bovine and porcine aortic bioprostheses
    • Ruzicka DJ, Hettich I, Hutter A, Bleiziffer S, Badiu CC, Bauernschmitt R, et al. The complete supraannular concept. In vivo hemodynamics of bovine and porcine aortic bioprostheses. Circulation 2009; 120 (Suppl): S139-S145.
    • (2009) Circulation , vol.120 , Issue.SUPPL
    • Ruzicka, D.J.1    Hettich, I.2    Hutter, A.3    Bleiziffer, S.4    Badiu, C.C.5    Bauernschmitt, R.6
  • 10
    • 36949006917 scopus 로고    scopus 로고
    • Patient-prosthesis mismatch may be irrelevant after aortic valve replacement with the 19-mm Perimount pericardial bioprosthesis in patients aged 65 years or older
    • Sakamoto Y, Hashimoto K, Okuyama H, Sasaki T, Takakura H, Onoguchi K. Patient-prosthesis mismatch may be irrelevant after aortic valve replacement with the 19-mm Perimount pericardial bioprosthesis in patients aged 65 years or older. J Artif Organs 2007; 10: 206-211.
    • (2007) J Artif Organs , vol.10 , pp. 206-211
    • Sakamoto, Y.1    Hashimoto, K.2    Okuyama, H.3    Sasaki, T.4    Takakura, H.5    Onoguchi, K.6
  • 11
    • 56049093020 scopus 로고    scopus 로고
    • Hemodynamic evaluation and midterm outcome of aortic valve replacement with size 19 Perimount prosthetic valve
    • Narayan P, Reeves BC, Rizvi SI, Shokrollahi K, Ismail H, Angelini GD, et al. Hemodynamic evaluation and midterm outcome of aortic valve replacement with size 19 Perimount prosthetic valve. Ann Thorac Surg 2008; 86: 1799-1803.
    • (2008) Ann Thorac Surg , vol.86 , pp. 1799-1803
    • Narayan, P.1    Reeves, B.C.2    Rizvi, S.I.3    Shokrollahi, K.4    Ismail, H.5    Angelini, G.D.6
  • 12
    • 34249010507 scopus 로고    scopus 로고
    • Carpentier-Edwards Perimount Magna valve versus Medtronic Hancock II: A matched hemodynamic comparison
    • Borger MA, Nette AF, Maganti M, Feindel CM. Carpentier-Edwards Perimount Magna valve versus Medtronic Hancock II: A matched hemodynamic comparison. Ann Thorac Surg 2007; 83: 2054-2058.
    • (2007) Ann Thorac Surg , vol.83 , pp. 2054-2058
    • Borger, M.A.1    Nette, A.F.2    Maganti, M.3    Feindel, C.M.4
  • 13
    • 27944474709 scopus 로고    scopus 로고
    • Carpentier-Edwards PERIMOUNT Magna bioprosthesis: A stented valve with stentless performance?
    • Totaro P, Degno N, Zaidi A, Youhana A, Argano V. Carpentier-Edwards PERIMOUNT Magna bioprosthesis: A stented valve with stentless performance? J Thorac Cardiovasc Surg 2005; 130: 1668-1674.
    • (2005) J Thorac Cardiovasc Surg , vol.130 , pp. 1668-1674
    • Totaro, P.1    Degno, N.2    Zaidi, A.3    Youhana, A.4    Argano, V.5
  • 14
    • 23844503868 scopus 로고    scopus 로고
    • Hemodynamic performance and incidence of patient-prosthesis mismatch of the complete supraannular perimount magna bioprosthesis in the aortic position
    • Botzenhardt F, Eichinger WB, Guenzinger R, Bleiziffer S, Wagner I, Bauernschmitt R, et al. Hemodynamic performance and incidence of patient-prosthesis mismatch of the complete supraannular perimount magna bioprosthesis in the aortic position. Thorac Cardiovasc Surg 2005; 53: 226-230.
    • (2005) Thorac Cardiovasc Surg , vol.53 , pp. 226-230
    • Botzenhardt, F.1    Eichinger, W.B.2    Guenzinger, R.3    Bleiziffer, S.4    Wagner, I.5    Bauernschmitt, R.6
  • 15
    • 34249795452 scopus 로고    scopus 로고
    • One year hemodynamic performance of the Perimount Magna pericardial xenograft and the Medtronic Mosaic bioprosthesis in the aortic position: A prospective randomized study
    • Dalmau MJ, Maríagonzález-Santos J, López-Rodríguez J, Bueno M, Arribas A, Nieto F. One year hemodynamic performance of the Perimount Magna pericardial xenograft and the Medtronic Mosaic bioprosthesis in the aortic position: A prospective randomized study. Interact Cardiovasc Thorac Surg 2007; 6: 345-349.
    • (2007) Interact Cardiovasc Thorac Surg , vol.6 , pp. 345-349
    • Dalmau, M.J.1    Maríagonzález-Santos, J.2    López-Rodríguez, J.3    Bueno, M.4    Arribas, A.5    Nieto, F.6
  • 16
    • 77449131207 scopus 로고    scopus 로고
    • Results of a propensity score-matched comparison of the Perimount Magna and Mosaic Ultra aortic valve prostheses
    • Wendt D, Buck T, Jánosi RA, Thielmann M, Pul U, Neuhäuser M, et al. Results of a propensity score-matched comparison of the Perimount Magna and Mosaic Ultra aortic valve prostheses. J Heart Valve Dis 2009; 18: 703-711.
    • (2009) J Heart Valve Dis , vol.18 , pp. 703-711
    • Wendt, D.1    Buck, T.2    Jánosi, R.A.3    Thielmann, M.4    Pul, U.5    Neuhäuser, M.6
  • 17
    • 77952302545 scopus 로고    scopus 로고
    • Reconsideration of patient-prosthesis mismatch definition from the valve indexed effective orifice area
    • Sakamoto Y, Yoshitake M, Naganuma H, Kawada N, Kinouchi K, Hashimoto K. Reconsideration of patient-prosthesis mismatch definition from the valve indexed effective orifice area. Ann Thorac Surg 2010; 89: 1951-1955.
    • (2010) Ann Thorac Surg , vol.89 , pp. 1951-1955
    • Sakamoto, Y.1    Yoshitake, M.2    Naganuma, H.3    Kawada, N.4    Kinouchi, K.5    Hashimoto, K.6
  • 18
    • 0025280867 scopus 로고
    • Prognostic implications of echocardiographically determined left ventricular mass in the Framingham heart study
    • Levy D, Garrison RJ, Savage DD, Kennel WB, Castelli WP. Prognostic implications of echocardiographically determined left ventricular mass in the Framingham heart study. N Engl J Med 1990; 322: 1561-1566.
    • (1990) N Engl J Med , vol.322 , pp. 1561-1566
    • Levy, D.1    Garrison, R.J.2    Savage, D.D.3    Kennel, W.B.4    Castelli, W.P.5
  • 19
    • 31044435337 scopus 로고    scopus 로고
    • Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly
    • Roscitano A, Benedetto U, Sciangula A, Merico E, Barberi F, Bianchini R, et al. Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly. Eur J Cardiothorac Surg 2006; 29: 139-143.
    • (2006) Eur J Cardiothorac Surg , vol.29 , pp. 139-143
    • Roscitano, A.1    Benedetto, U.2    Sciangula, A.3    Merico, E.4    Barberi, F.5    Bianchini, R.6
  • 20
    • 0031917736 scopus 로고    scopus 로고
    • Aortic valve replacement with a small mechanical valve prosthesis: A clinical and echocardiographic study of a St Jude Medical valve prosthesis
    • Aoyagi S, Arinaga K, Fukunaga S, Kawano H, Kawara T. Aortic valve replacement with a small mechanical valve prosthesis: A clinical and echocardiographic study of a St Jude Medical valve prosthesis. Jpn Circ J 1998; 62: 244-248.
    • (1998) Jpn Circ J , vol.62 , pp. 244-248
    • Aoyagi, S.1    Arinaga, K.2    Fukunaga, S.3    Kawano, H.4    Kawara, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.