메뉴 건너뛰기




Volumn 23, Issue 12, 2011, Pages 527-531

Radial artery spasm during transradial coronary procedures

Author keywords

[No Author keywords available]

Indexed keywords

DILTIAZEM; GLYCERYL TRINITRATE; HEPARIN; LIDOCAINE; MAGNESIUM SULFATE; MOLSIDOMINE; NICORANDIL; NITROPRUSSIDE SODIUM; PHENTOLAMINE; VASODILATOR AGENT; VERAPAMIL;

EID: 82955171361     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (72)

References (34)
  • 1
    • 0024555812 scopus 로고
    • Percutaneous radial artery approach for coronary angiography
    • DOI 10.1002/ccd.1810160103
    • Campeau L. Percutaneous radial artery approach for coronary angiography. Catheter Cardiovasc Diagn. 1989;16(1):3-7. (Pubitemid 19033502)
    • (1989) Catheterization and Cardiovascular Diagnosis , vol.16 , Issue.1 , pp. 3-7
    • Campeau, L.1
  • 2
    • 0027439206 scopus 로고
    • Percutaneous transradial artery approach for coronary stent implantation
    • Kiemeneij F, Laarman GJ. Percutaneous transradial artery approach for coronary stent implantation. Cathet Cardiovasc Diagn. 1993;30(2):173-178. (Pubitemid 23292091)
    • (1993) Catheterization and Cardiovascular Diagnosis , vol.30 , Issue.2 , pp. 173-178
    • Kiemeneij, F.1    Laarman, G.J.2
  • 3
    • 0344455777 scopus 로고
    • Erratum in
    • Erratum in Cathet Cardiovasc Diagn. 1993;30(4):358.
    • (1993) Cathet Cardiovasc Diagn , vol.30 , Issue.4 , pp. 358
  • 4
    • 70350048414 scopus 로고    scopus 로고
    • Transradial versus transfemoral percutaneous coronary intervention in acute myocardial infarction: Systematic overview and meta-analysis
    • Vorobcsuk A, Konyi A, Aradi D, et al. Transradial versus transfemoral percutaneous coronary intervention in acute myocardial infarction: systematic overview and meta-analysis. Am Heart J. 2009;158(5):814-821.
    • (2009) Am Heart J , vol.158 , Issue.5 , pp. 814-821
    • Vorobcsuk, A.1    Konyi, A.2    Aradi, D.3
  • 5
    • 57149103475 scopus 로고    scopus 로고
    • Radial versus femoral access for coronary angiography or intervention and the impact on major bleeding and ischemic events: A systematic review and meta-analysis of randomized trials
    • Jolly SS, Amlani S, Hamon M, et al. Radial versus femoral access for coronary angiography or intervention and the impact on major bleeding and ischemic events: a systematic review and meta-analysis of randomized trials. Am Heart J. 2009;157(1):132-140.
    • (2009) Am Heart J , vol.157 , Issue.1 , pp. 132-140
    • Jolly, S.S.1    Amlani, S.2    Hamon, M.3
  • 6
    • 77958534695 scopus 로고    scopus 로고
    • Transradial approach for coronary angiography and interventions: Results of the first international transradial practice survey
    • Bertrand OF, Rao SV, Pancholy S, et al. Transradial approach for coronary angiography and interventions: results of the first international transradial practice survey. JACC Cardiovasc Interv. 2010;3(10):1022-1031.
    • (2010) JACC Cardiovasc Interv , vol.3 , Issue.10 , pp. 1022-1031
    • Bertrand, O.F.1    Rao, S.V.2    Pancholy, S.3
  • 7
    • 78649993160 scopus 로고    scopus 로고
    • TRI-China collaboration group. Prevalence of transradial coronary angiography and intervention in China: Report from the Transradial coronary intervention Registration Investigation in China (TRI-China)
    • Wang L, Yang Y, Zhou Y, et al. TRI-China collaboration group. Prevalence of transradial coronary angiography and intervention in China: report from the Transradial coronary intervention Registration Investigation in China (TRI-China). Int J Cardiol. 2010;145(2):246-247.
    • (2010) Int J Cardiol , vol.145 , Issue.2 , pp. 246-247
    • Wang, L.1    Yang, Y.2    Zhou, Y.3
  • 9
    • 0028898382 scopus 로고
    • Comparison among arterial grafts and coronary artery. An attempt at functional classification
    • He GW, Yang CQ. Comparison among arterial grafts and coronary artery. An attempt at functional classification. J Thorac Cardiovasc Surg. 1995;109(4):707-715.
    • (1995) J Thorac Cardiovasc Surg , vol.109 , Issue.4 , pp. 707-715
    • He, G.W.1    Yang, C.Q.2
  • 11
    • 0027361091 scopus 로고
    • Vasoreactivity of the radial artery. Comparison with the internal mammary and gastroepiploic arteries with implications for coronary artery surgery
    • Chardigny C, Jebara VA, Acar C, et al. Vasoreactivity of the radial artery. Comparison with the internal mammary and gastroepiploic arteries with implications for coronary artery surgery. Circulation. 1993;88(5 Pt 2):II115-II127.
    • (1993) Circulation , vol.88 , Issue.5 PART 2
    • Chardigny, C.1    Jebara, V.A.2    Acar, C.3
  • 13
    • 57149114797 scopus 로고    scopus 로고
    • Magnesium sulphate during transradial cardiac catheterization: A new use for an old drug?
    • Byrne J, Spence M, Haegeli L, et al. Magnesium sulphate during transradial cardiac catheterization: a new use for an old drug? J Invasive Cardiol. 2008;20(10):539-542.
    • (2008) J Invasive Cardiol , vol.20 , Issue.10 , pp. 539-542
    • Byrne, J.1    Spence, M.2    Haegeli, L.3
  • 14
    • 0031803398 scopus 로고    scopus 로고
    • Learning curve in the use of the radial artery as vascular access in the performance of percutaneous transluminal coronary angioplasty
    • DOI 10.1002/(SICI)1097-0304(199806)44:2<147::AID-CCD5>3.0.CO;2-6
    • Goldberg SL, Renslo R, Sinow R, et al. Learning curve in the use of the radial artery as vascular access in the performance of percutaneous transluminal coronary angioplasty. Catheter Cardiovasc Diagn. 1998;44(2):147-152. (Pubitemid 28255911)
    • (1998) Catheterization and Cardiovascular Diagnosis , vol.44 , Issue.2 , pp. 147-152
    • Goldberg, S.L.1    Renslo, R.2    Sinow, R.3    French, W.J.4
  • 16
    • 3242794333 scopus 로고    scopus 로고
    • The use of a hydrophilic-coated catheter during transradial cardiac catheterization is associated with a low incidence of radial artery spasm
    • DOI 10.1016/j.ijcard.2003.07.016, PII S0167527303005072
    • Koga S, Ikeda S, Futagawa K, et al. The use of a hydrophilic-coated catheter during transradial cardiac catheterization is associated with a low incidence of radial artery spasm. Int J Cardiol. 2004;96(2):255-258. (Pubitemid 38979907)
    • (2004) International Journal of Cardiology , vol.96 , Issue.2 , pp. 255-258
    • Koga, S.1    Ikeda, S.2    Futagawa, K.3    Sonoda, K.4    Yoshitake, T.5    Miyahara, Y.6    Kohno, S.7
  • 18
    • 78349258972 scopus 로고    scopus 로고
    • Reduction in spasm with a long hydrophylic transradial sheath
    • Caussin C, Gharbi M, Durier C, et al. Reduction in spasm with a long hydrophylic transradial sheath. Catheter Cardiovasc Interv. 2010;76(5):668-672.
    • (2010) Catheter Cardiovasc Interv , vol.76 , Issue.5 , pp. 668-672
    • Caussin, C.1    Gharbi, M.2    Durier, C.3
  • 19
    • 77956014334 scopus 로고    scopus 로고
    • Impact of length and hydrophilic coating of the introducer sheath on radial artery spasm during transradial coronary intervention: A randomized study
    • Rathore S, Stables RH, Pauriah M, et al. Impact of length and hydrophilic coating of the introducer sheath on radial artery spasm during transradial coronary intervention: a randomized study. JACC Cardiovasc Interv. 2010;3(5):475-483.
    • (2010) JACC Cardiovasc Interv , vol.3 , Issue.5 , pp. 475-483
    • Rathore, S.1    Stables, R.H.2    Pauriah, M.3
  • 20
    • 26644455290 scopus 로고    scopus 로고
    • Assessment of the efficacy of phentolamine to prevent radial artery spasm during cardiac catheterization procedures: A randomized study comparing phentolamine vs. verapamil
    • DOI 10.1002/ccd.20434
    • Ruiz-Salmeron RJ, Mora R, Masotti M, et al. Assessment of the efficacy of phentolamine to prevent radial artery spasm during cardiac catheterization procedures: a randomized study comparing phentolamine vs verapamil. Catheter Cardiovasc Interv. 2005;66(2):192-198. (Pubitemid 41443024)
    • (2005) Catheterization and Cardiovascular Interventions , vol.66 , Issue.2 , pp. 192-198
    • Ruiz-Salmeron, R.J.1    Mora, R.2    Masotti, M.3    Betriu, A.4
  • 21
    • 77950915300 scopus 로고    scopus 로고
    • Incidence and predictors of radial artery spasm during transradial coronary angiography and intervention
    • Jia DA, Zhou YJ, Shi DM, et al. Incidence and predictors of radial artery spasm during transradial coronary angiography and intervention. Chin Med J (Engl). 2010;123(7):843-847.
    • (2010) Chin Med J (Engl) , vol.123 , Issue.7 , pp. 843-847
    • Jia, D.A.1    Zhou, Y.J.2    Shi, D.M.3
  • 23
    • 21244477479 scopus 로고    scopus 로고
    • Radial artery spasm in transradial cardiac catheterization. Assessment of factors related to its occurrence and of its consequences during follow-up
    • Ruiz-Salmeron RJ, Mora R, Velez-Gimon M, et al. [Radial artery spasm in transradial cardiac catheterization. Assessment of factors related to its occurrence, and of its consequences during follow-up]. Rev Esp Cardiol. 2005;58(5):5504-5511.
    • (2005) Rev Esp Cardiol , vol.58 , Issue.5 , pp. 5504-5511
    • Ruiz-Salmeron, R.J.1    Mora, R.2    Velez-Gimon, M.3
  • 24
    • 33144455598 scopus 로고    scopus 로고
    • A simple and effective regimen for prevention of radial artery spasm during coronary catheterization
    • Chen CW, Lin CL, Lin TK, et al. A simple and effective regimen for prevention of radial artery spasm during coronary catheterization. Cardiology. 2006;105(1):43-47.
    • (2006) Cardiology , vol.105 , Issue.1 , pp. 43-47
    • Chen, C.W.1    Lin, C.L.2    Lin, T.K.3
  • 25
    • 79953033738 scopus 로고    scopus 로고
    • Radial artery flow-mediated dilation predicts arterial spasm during transradial coronary interventions
    • Jun 14. [Epub ahead of print]
    • Deftereos S, Giannopoulos G, Kossyvakis C, et al. Radial artery flow-mediated dilation predicts arterial spasm during transradial coronary interventions. Catheter Cardiovasc Interv. 2010 Jun 14. [Epub ahead of print]
    • (2010) Catheter Cardiovasc Interv
    • Deftereos, S.1    Giannopoulos, G.2    Kossyvakis, C.3
  • 28
    • 0037711236 scopus 로고    scopus 로고
    • Hydrophilic coating aids radial sheath withdrawal and reduces patient discomfort following transradial coronary intervention: A randomized double-blind comparison of coated and uncoated sheaths
    • DOI 10.1002/ccd.10444
    • Kiemeneij F, Fraser D, Slagboom T, et al. Hydrophilic coating aids radial sheath withdrawal and reduces patient discomfort following transradial coronary intervention: a randomized double-blind comparison of coated and uncoated sheaths. Catheter Cardiovasc Interv. 2003;59(2):161-164. (Pubitemid 36665944)
    • (2003) Catheterization and Cardiovascular Interventions , vol.59 , Issue.2 , pp. 161-164
    • Kiemeneij, F.1    Fraser, D.2    Slagboom, T.3    Laarman, G.4    Van Der Wieken, R.5
  • 30
    • 34447574689 scopus 로고    scopus 로고
    • Comparative study of nicorandil and a spasmolytic cocktail in preventing radial artery spasm during transradial coronary angiography
    • DOI 10.1016/j.ijcard.2006.10.008, PII S0167527306013593
    • Kim SH, Kim EJ, Cheon WS, et al. Comparative study of nicorandil and a spasmolytic cocktail in preventing radial artery spasm during transradial coronary angiography. Int J Cardiol. 2007;120(3):325-330. (Pubitemid 47071930)
    • (2007) International Journal of Cardiology , vol.120 , Issue.3 , pp. 325-330
    • Kim, S.H.1    Kim, E.J.2    Cheon, W.S.3    Kim, M.-K.4    Park, W.J.5    Cho, G.-Y.6    Choi, Y.J.7    Rhim, C.Y.8
  • 31
    • 20444389402 scopus 로고    scopus 로고
    • Midterm angiographic patency and vasoreactive profile of proximal versus distal radial artery grafts
    • DOI 10.1016/j.athoracsur.2005.01.003, PII S0003497505000111
    • Gaudino M, Nasso G, Canosa C, et al. Midterm angiographic patency and vasoreactive profile of proximal versus distal radial artery grafts. Ann Thorac Surg. 2005;79(6):1987-1989. (Pubitemid 40804174)
    • (2005) Annals of Thoracic Surgery , vol.79 , Issue.6 , pp. 1987-1989
    • Gaudino, M.1    Nasso, G.2    Canosa, C.3    Glieca, F.4    Salica, A.5    Alessandrini, F.6    Possati, G.7
  • 33
    • 0032929347 scopus 로고    scopus 로고
    • Influence of the ratio between radial artery inner diameter and sheath outer diameter on radial artery flow after transradial coronary intervention
    • Saito S, Ikei H, Hosokawa G, et al. Influence of the ratio between radial artery inner diameter and sheath outer diameter on radial artery flow after transradial coronary intervention. Catheter Cardiovasc Interv. 1999;46(2):173-178. (Pubitemid 29066623)
    • (1999) Catheterization and Cardiovascular Diagnosis , vol.46 , Issue.2 , pp. 173-178
    • Saito, S.1    Ikei, H.2    Hosokawa, G.3    Tanaka, S.4
  • 34
    • 0000028461 scopus 로고    scopus 로고
    • Feasibility of routine transradial coronary angiography: A single operator's experience
    • Louvard Y, Krol M, Pezzano M, et al. Feasibility of routine transradial coronary angiography: a single operator's experience. J Invasive Cardiol. 1999;11(9):543-548.
    • (1999) J Invasive Cardiol , vol.11 , Issue.9 , pp. 543-548
    • Louvard, Y.1    Krol, M.2    Pezzano, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.