메뉴 건너뛰기




Volumn 66, Issue 2, 2005, Pages 192-198

Assessment of the efficacy of phentolamine to prevent radial artery spasm during cardiac catheterization procedures: A randomized study comparing phentolamine vs. verapamil

Author keywords

Angiography; Cardiac catheterization procedures; Peripheral catheterization; Radial artery

Indexed keywords

ALPHA ADRENERGIC RECEPTOR STIMULATING AGENT; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; CALCIUM ANTAGONIST; DIPEPTIDYL CARBOXYPEPTIDASE INHIBITOR; NITRATE; PHENTOLAMINE; SPASMOLYTIC AGENT; VASODILATOR AGENT; VERAPAMIL;

EID: 26644455290     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/ccd.20434     Document Type: Article
Times cited : (57)

References (18)
  • 1
    • 0030998942 scopus 로고    scopus 로고
    • A randomized comparison of percutaneous transluminal coronary angioplasty by the radial, braquial and femoral approaches: The ACCESS study
    • Kiemeneij F, Laarman GJ, Odekerken D, Slagboom T, van der Wieken R. A randomized comparison of percutaneous transluminal coronary angioplasty by the radial, braquial and femoral approaches: the ACCESS study. J Am Coll Cardiol 1997;29: 1269-1275.
    • (1997) J Am Coll Cardiol , vol.29 , pp. 1269-1275
    • Kiemeneij, F.1    Laarman, G.J.2    Odekerken, D.3    Slagboom, T.4    Van Der Wieken, R.5
  • 2
    • 0035143016 scopus 로고    scopus 로고
    • Coronary angiography through the radial or the femoral approach: The CARAFE study
    • Louvard Y, Lefevre T, Allain A, Morice M. Coronary angiography through the radial or the femoral approach: the CARAFE study. Catheter Cardiovasc Interv 2001;52:181-187.
    • (2001) Catheter Cardiovasc Interv , vol.52 , pp. 181-187
    • Louvard, Y.1    Lefevre, T.2    Allain, A.3    Morice, M.4
  • 3
    • 0031149820 scopus 로고    scopus 로고
    • Radial artery has higher receptor-mediated contractility but similar endothelial function compared with mammary artery
    • He GW, Yang CQ. Radial artery has higher receptor-mediated contractility but similar endothelial function compared with mammary artery. Ann Thorac Surg 1997;63:1346-1352.
    • (1997) Ann Thorac Surg , vol.63 , pp. 1346-1352
    • He, G.W.1    Yang, C.Q.2
  • 4
    • 0020660063 scopus 로고
    • Adverse reactions to calcium antagonists
    • Lewis JG. Adverse reactions to calcium antagonists. Drugs 1983;25:196-222.
    • (1983) Drugs , vol.25 , pp. 196-222
    • Lewis, J.G.1
  • 7
    • 0031955002 scopus 로고    scopus 로고
    • Characteristics of adrenoreceptors in the human radial artery: Clinical implications
    • He GW, Yang CQ. Characteristics of adrenoreceptors in the human radial artery: clinical implications. J Thorac Cardiovasc Surg 1998;115:1136-1141.
    • (1998) J Thorac Cardiovasc Surg , vol.115 , pp. 1136-1141
    • He, G.W.1    Yang, C.Q.2
  • 8
    • 2342429309 scopus 로고    scopus 로고
    • Evaluation of the ulnopalmar arterial arches with pulse oximetry and plethysmography: Comparison with the Allen's test in 1010 patients
    • Barbeau GR, Arsenault F, Dugas L, Simard S, Lariviere MM. Evaluation of the ulnopalmar arterial arches with pulse oximetry and plethysmography: comparison with the Allen's test in 1010 patients. Am Heart J 2004;147:489-493.
    • (2004) Am Heart J , vol.147 , pp. 489-493
    • Barbeau, G.R.1    Arsenault, F.2    Dugas, L.3    Simard, S.4    Lariviere, M.M.5
  • 9
    • 0037711236 scopus 로고    scopus 로고
    • Hydrophilic coating aids radial sheath withdrawal and reduces patient discomfort following trasnradial coronary intervention: A randomized double-blind comparixonof coated and uncoated sheaths
    • Kiemeneij F, Fraser D, Slagboom T, Laarman G, van der Wieken R. Hydrophilic coating aids radial sheath withdrawal and reduces patient discomfort following trasnradial coronary intervention: a randomized double-blind comparixonof coated and uncoated sheaths. Catheter Cardiovasc Interv 2003;59:161-164.
    • (2003) Catheter Cardiovasc Interv , vol.59 , pp. 161-164
    • Kiemeneij, F.1    Fraser, D.2    Slagboom, T.3    Laarman, G.4    Van Der Wieken, R.5
  • 10
    • 3242794333 scopus 로고    scopus 로고
    • The use of a hydrophilic-coated cahteter during transradial cardiac catheterization is associated with a low incedence of radial artery spasm
    • Koga S, Ikeda S, Futagawa K, Sonoda K, Yoshitake T, Miyahara Y, Kohno S. The use of a hydrophilic-coated cahteter during transradial cardiac catheterization is associated with a low incedence of radial artery spasm. Int J Cardiol 2004;96:255-258.
    • (2004) Int J Cardiol , vol.96 , pp. 255-258
    • Koga, S.1    Ikeda, S.2    Futagawa, K.3    Sonoda, K.4    Yoshitake, T.5    Miyahara, Y.6    Kohno, S.7
  • 11
    • 0033968495 scopus 로고    scopus 로고
    • Comparative study on calcium channel antagonists in the human radial artery: Clinical implications
    • He GW, Yang CQ. Comparative study on calcium channel antagonists in the human radial artery: clinical implications. J Thorac Cardiovasc Surg 2000;119:94-100.
    • (2000) J Thorac Cardiovasc Surg , vol.119 , pp. 94-100
    • He, G.W.1    Yang, C.Q.2
  • 12
    • 26644439454 scopus 로고    scopus 로고
    • Cardiovascular receptors and drug therapy
    • Messerli FH, editor. Philadelphia: W.B. Saunders
    • Van Zwieten PA. 1996. Cardiovascular receptors and drug therapy. In: Messerli FH, editor. Cardiovascular drug therapy. Philadelphia: W.B. Saunders. p 334-347.
    • (1996) Cardiovascular Drug Therapy , pp. 334-347
    • Van Zwieten, P.A.1
  • 14
    • 0019379632 scopus 로고
    • The pharmacology of verapamil: III, pharmacokinetics in normal subjects after intravenous drug administration
    • Dominic JA, Bourne DW, Tan TG, Kirsten EB, McAllister RG. The pharmacology of verapamil: III, pharmacokinetics in normal subjects after intravenous drug administration. J Cardiovasc Pharmacol 1981;3:25-38.
    • (1981) J Cardiovasc Pharmacol , vol.3 , pp. 25-38
    • Dominic, J.A.1    Bourne, D.W.2    Tan, T.G.3    Kirsten, E.B.4    McAllister, R.G.5
  • 17
    • 0033556298 scopus 로고    scopus 로고
    • Ultrasonic assessment of vascular complications in coronary angiography and angioplasty after transradial approach
    • Nagai S, Abe S, Sato T, Hozawa K, Yuki K, Hanashima K, Tomoike H. Ultrasonic assessment of vascular complications in coronary angiography and angioplasty after transradial approach. Am J Cardiol 1999;83:180-186.
    • (1999) Am J Cardiol , vol.83 , pp. 180-186
    • Nagai, S.1    Abe, S.2    Sato, T.3    Hozawa, K.4    Yuki, K.5    Hanashima, K.6    Tomoike, H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.