메뉴 건너뛰기




Volumn 25, Issue 2, 2010, Pages 514-525

Transient performance improvement of wind turbines with doubly fed induction generators using nonlinear control strategy

Author keywords

Doubly fed induction generator (DFIG); Internal dynamics; Nonlinear control; Transient performance; Wind turbine (WT)

Indexed keywords

BACK ELECTROMOTIVE FORCE; BACK-EMF; DOUBLY FED INDUCTION GENERATORS; DOUBLY-FED INDUCTION GENERATOR; DYNAMIC BEHAVIORS; DYNAMIC CHARACTERISTICS; EXTERNAL DYNAMICS; GRID VOLTAGE; IN-RUSH CURRENT; INTERNAL DYNAMICS; LINEAR CONTROLS; NON LINEAR CONTROL; NON-LINEAR CONTROLLERS; NON-MINIMUM PHASE; OPERATING CONDITION; RIDETHROUGH CAPABILITY; ROTOR CURRENT; ROTOR DYNAMIC; ROTOR VOLTAGE; TRANSIENT PERFORMANCE; VOLTAGE DIP;

EID: 77952958302     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2009.2032169     Document Type: Article
Times cited : (106)

References (21)
  • 2
    • 0030146394 scopus 로고    scopus 로고
    • Doubly fed induction generator using back-to-back PWM converters and its application to variablespeed wind-energy generation
    • R. Pena, J. Clare, and G. Asher, "Doubly fed induction generator using back-to-back PWM converters and its application to variable speed wind energy generation," in Proc. Inst. Electr. Eng. Electr. Power Appl., vol.143, no.3, pp. 231-241, May 1996. (Pubitemid 126760209)
    • (1996) IEE Proceedings: Electric Power Applications , vol.143 , Issue.3 , pp. 231-241
    • Pena, R.1    Clare, J.C.2    Asher, G.M.3
  • 3
    • 0029307617 scopus 로고
    • Torque and reactive power control of a doubly fed induction machine by position sensorless scheme
    • May/Jun.
    • L. Xu and C. Wei, "Torque and reactive power control of a doubly fed induction machine by position sensorless scheme," IEEE Trans. Ind. Appl., vol.31, no.3, pp. 636-642, May/Jun. 1995.
    • (1995) IEEE Trans. Ind. Appl. , vol.31 , Issue.3 , pp. 636-642
    • Xu, L.1    Wei, C.2
  • 4
    • 28244465179 scopus 로고    scopus 로고
    • Wind-turbine fault ridethrough enhancement
    • Nov.
    • A. Mullane, G. Lightbody, and R. Yacamini, "Wind-turbine fault ridethrough enhancement," IEEE Trans. Power Syst., vol.20, no.4, pp. 1929-1937, Nov. 2005.
    • (2005) IEEE Trans. Power Syst. , vol.20 , Issue.4 , pp. 1929-1937
    • Mullane, A.1    Lightbody, G.2    Yacamini, R.3
  • 5
    • 34548274089 scopus 로고    scopus 로고
    • Dynamic behavior of the doubly fed induction generator during three-phase voltage dips
    • Sep.
    • J. Lopez, P. Sanchis, X. Roboam, and L. Marroyo, "Dynamic behavior of the doubly fed induction generator during three-phase voltage dips," IEEE Trans. Energy Convers., vol.22, no.3, pp. 709-717, Sep. 2007.
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.3 , pp. 709-717
    • Lopez, J.1    Sanchis, P.2    Roboam, X.3    Marroyo, L.4
  • 6
    • 33947634098 scopus 로고    scopus 로고
    • Short-circuit current of wind turbines with doubly fed induction generator
    • Mar.
    • J. Morren and S.W. de Haan, "Short-circuit current of wind turbines with doubly fed induction generator," IEEE Trans. Energy Convers., vol.22, no.1, pp. 174-180, Mar. 2007.
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.1 , pp. 174-180
    • Morren, J.1    De Haan, S.W.2
  • 7
    • 20544451598 scopus 로고    scopus 로고
    • Ride-through of wind turbines with doubly fed induction generator during a voltage dip
    • Jun.
    • J. Morren and S. W. H. de Haan, "Ride-through of wind turbines with doubly fed induction generator during a voltage dip," IEEE Trans. Energy Convers., vol.20, no.2, pp. 435-441, Jun. 2005.
    • (2005) IEEE Trans. Energy Convers. , vol.20 , Issue.2 , pp. 435-441
    • Morren, J.1    De Haan, S.W.H.2
  • 8
    • 33947430524 scopus 로고    scopus 로고
    • Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    • Sep.
    • D. Xiang, Li. Ran, P. J. Tavner, and S. Yang, "Control of a doubly fed induction generator in a wind turbine during grid fault ride-through," IEEE Trans. Energy Convers., vol.21, no.3, pp. 652-662, Sep. 2006.
    • (2006) IEEE Trans. Energy Convers. , vol.21 , Issue.3 , pp. 652-662
    • Xiang, D.1    Ran, Li.2    Tavner, P.J.3    Yang, S.4
  • 9
    • 40849141184 scopus 로고    scopus 로고
    • Wind turbines based on doubly fed induction generator under asymmetrical voltage dips
    • Mar.
    • J. Lopez, P. Sanchis, X. Roboam, and L.Marroyo,"Wind turbines based on doubly fed induction generator under asymmetrical voltage dips," IEEE Trans. Energy Convers., vol.23, no.1, pp. 331-1330, Mar. 2008.
    • (2008) IEEE Trans. Energy Convers. , vol.23 , Issue.1 , pp. 331-1330
    • Lopez, J.1    Sanchis, P.2    Roboam, X.3    Marroyo, L.4
  • 10
    • 12744262671 scopus 로고    scopus 로고
    • Evaluation of current control methods for wind turbines using doubly-fed induction machines
    • Jan.
    • A. Petersson, L. Harnefors, and T. Thiringer, "Evaluation of current control methods for wind turbines using doubly-fed induction machines," IEEE Trans. Power Electron., vol.20, no.1, pp. 227-235, Jan. 2005.
    • (2005) IEEE Trans. Power Electron. , vol.20 , Issue.1 , pp. 227-235
    • Petersson, A.1    Harnefors, L.2    Thiringer, T.3
  • 11
    • 0038359393 scopus 로고    scopus 로고
    • Comparison of fixed speed and doubly-fed induction wind turbines during power system disturbances
    • May
    • L. Holdsworth, X. G. Wu, J. B. Ekanayake, and N. Jenkins, "Comparison of fixed speed and doubly-fed induction wind turbines during power system disturbances," in Proc. Inst. Electr. Eng. Gener. Transm. Distrib., vol.150, no.3, pp. 343-352, May 2003.
    • (2003) Proc. Inst. Electr. Eng. Gener. Transm. Distrib. , vol.150 , Issue.3 , pp. 343-352
    • Holdsworth, L.1    Wu, X.G.2    Ekanayake, J.B.3    Jenkins, N.4
  • 12
    • 71849101601 scopus 로고    scopus 로고
    • Study on the control of DFIG and its responses to grid disturbances
    • Montreal, QC, Canada, Jun.
    • M. Yin, G. Li, M. Zhou, G. Liu, and C. Zhao, "Study on the control of DFIG and its responses to grid disturbances," in Proc. IEEE PES Gen. Meeting, Montreal, QC, Canada, Jun. 2006, 12 pp.
    • (2006) Proc. IEEE PES Gen. Meeting , pp. 12
    • Yin, M.1    Li, G.2    Zhou, M.3    Liu, G.4    Zhao, C.5
  • 13
    • 8744250132 scopus 로고    scopus 로고
    • Voltage recovery of grid-connected wind turbines with DFIG after a short-circuit fault
    • Jun.
    • T. Sun, Z. Chen, and F. Blaabjerg, "Voltage recovery of grid-connected wind turbines with DFIG after a short-circuit fault," in Proc. IEEE PESC Conf., Jun. 2004, vol.3, pp. 1991-1997.
    • (2004) Proc. IEEE PESC Conf. , vol.3 , pp. 1991-1997
    • Sun, T.1    Chen, Z.2    Blaabjerg, F.3
  • 14
    • 34748865378 scopus 로고    scopus 로고
    • Dynamic behavior of DFIG-based wind turbines during grid faults
    • Apr.
    • I. Erlich, H. Wrede, and C. Feltes, "Dynamic behavior of DFIG-based wind turbines during grid faults," in Proc. IEEE Power Convers. Conf., Apr. 2007, pp. 1195-1200.
    • (2007) Proc. IEEE Power Convers. Conf. , pp. 1195-1200
    • Erlich, I.1    Wrede, H.2    Feltes, C.3
  • 15
    • 10244279164 scopus 로고    scopus 로고
    • Influence of variable-speed wind generators in transient stability margin of the conventional generators integrated in electrical grids
    • Dec.
    • M. V. A. Nunes, J. A. P. Lopes, H. H. Zurn, U. H. Bezerra, and R. G. Almeuda, "Influence of variable-speed wind generators in transient stability margin of the conventional generators integrated in electrical grids," IEEE Trans. Energy Convers., vol.19, no.4, pp. 692-701, Dec. 2004.
    • (2004) IEEE Trans. Energy Convers. , vol.19 , Issue.4 , pp. 692-701
    • Nunes, M.V.A.1    Lopes, J.A.P.2    Zurn, H.H.3    Bezerra, U.H.4    Almeuda, R.G.5
  • 16
    • 20544446440 scopus 로고    scopus 로고
    • Doubly fed induction generator model for transient stability analysis
    • Jun.
    • P. Ledesma and J. Usaola, "Doubly fed induction generator model for transient stability analysis," IEEE Trans. Energy Convers., vol.20, no.2, pp. 388-397, Jun. 2004.
    • (2004) IEEE Trans. Energy Convers. , vol.20 , Issue.2 , pp. 388-397
    • Ledesma, P.1    Usaola, J.2
  • 17
    • 34548237470 scopus 로고    scopus 로고
    • Modal analysis of grid-connected doubly fed induction generators
    • Sep.
    • F. Mei and B. Pal, "Modal analysis of grid-connected doubly fed induction generators," IEEE Trans. Energy Convers., vol.22, no.3, pp. 728-736, Sep. 2007.
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.3 , pp. 728-736
    • Mei, F.1    Pal, B.2
  • 19
    • 0004178386 scopus 로고
    • 2nd ed. Englewood Cliffs, NJ: Prentice-Hall
    • H. K. Khalil, Nonlinear Systems, 2nd ed. Englewood Cliffs, NJ: Prentice-Hall, 1995.
    • (1995) Nonlinear Systems
    • Khalil, H.K.1
  • 20
    • 33646379842 scopus 로고    scopus 로고
    • Short-term voltage instability: Effects on synchronous and induction machines
    • May
    • E. G. Potamianakis and C. D. Vournas, "Short-term voltage instability: Effects on synchronous and induction machines," IEEE Trans. Power Syst., vol.21, no.2, pp. 791-798, May 2006.
    • (2006) IEEE Trans. Power Syst. , vol.21 , Issue.2 , pp. 791-798
    • Potamianakis, E.G.1    Vournas, C.D.2
  • 21
    • 48449098817 scopus 로고    scopus 로고
    • An improved fault ride-through strategy for doubly fed induction generatorbasedwind turbines
    • A. H. Kasem, E. F. EI-Saadany, H. H. EI-Tamaly, and M. A. A.Wahab, "An improved fault ride-through strategy for doubly fed induction generatorbasedwind turbines," IETRenew. PowerGener., vol.2, no.4, pp. 201-214, 2008.
    • (2008) IETRenew. PowerGener. , vol.2 , Issue.4 , pp. 201-214
    • Kasem, A.H.1    Ei-Saadany, E.F.2    Ei-Tamaly, H.H.3    Wahab, M.A.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.